X2E XORAYA DATACUBE User manual

XORAYA DATACUBE
User Manual
Version: 1.2 / March 2018

© 2018 X2E GmbH
This user manual is protected by copyright; all usual rights reserved. Reproduction of this user manual, even in
part, is only permitted with the approval of X2E GmbH. Any infringement will result in liability for damages and
may result in criminal prosecution.
All product names and brands used in this user manual are the property of their respective owners.

User Manual XORAYA DATACUBE
3
Table of contents
Introduction.............................................................................................4
Intended use............................................................................................4
Delivery contents .....................................................................................4
General safety instructions......................................................................5
Connections and controls........................................................................6
Installation...............................................................................................9
Connecting...............................................................................................9
XORAYASuite..........................................................................................10
Network settings ....................................................................................11
Operation..............................................................................................13
Download via Hdd-Control.....................................................................13
Automatic download service..................................................................20
Update firmware....................................................................................22
Cleaning................................................................................................23
Repair...................................................................................................23
Disposal................................................................................................23

User Manual XORAYA DATACUBE
4
Introduction
Intended use
The XORAYA DATACUBE is a fast read-out station for XORAYA external storage units. Up to six
devices can be connected and accessed by a terminal or PC.
The DATACUBE is designed for industrial areas and must not be used in residential areas.
You may only operate the DATACUBE within the scope of the technical specifications provided
in this user manual. Additionally, the use in hazardous areas is not allowed.
The connecting cables may be extended up to a maximum of 30 m, while it is not allowed to
extend the power cord between AC adapter and DATACUBE.
You can find the declaration of conformity at the end of this user manual.
Delivery contents
XORAYA DATACUBE
power cord with AC adapter
user manual
XORAYASuite
optionally: XORAYA external storage unit(s) with connection cables
Check to ensure that the delivery is complete and all hardware components are in sound
condition. If the delivery is incomplete or supplied components are damaged, contact X2E
immediately. Do not use damaged components.

User Manual XORAYA DATACUBE
5
General safety instructions
The XORAYA DATACUBE is only intended for use by qualified personnel. Read the user man-
ual and especially this chapter thoroughly before operating.
CAUTION
Electric shock due to damaged components
Damages to the D
ATACUBE
, the power cord or the AC adapter can result in
electric shock.
Check all components regularly for damages.
Only connect the DATACUBE if all components are undamaged.
CAUTION
Device damage due to vibrations, dirt or liquids
Excessive vibrations, dirt or liquids may result in malfunction or destruction
of the DATACUBE.
Avoid exposing the DATACUBE to excessive vibrations, dirt or liquids.
Keep the DATACUBE clean, especially plugs and sockets to ensure a
reliable contact.
Never open the DATACUBE.
CAUTION
Device damage due to electrostatic discharge
Electronic components can be destroyed by electrostatic discharge.
Avoid touching connectors and connector pins.
Ground yourself before carrying the DATACUBE in your hands.
Operate the DATACUBE in an ESD-compliant environment.

User Manual XORAYA DATACUBE
6
Connections and controls
Front view
Back view

User Manual XORAYA DATACUBE
7
Connections for XORAYA external storage units with LEDs (A1-A6)
LED Meaning
red when connection between DATACUBE and XORAYA ex-
ternal storage unit is established (locked)
green when disconnected via button on XORAYA external
storage unit or via software (unlocked)
green when the XORAYA external storage unit is voltage-
supplied
flashes red when accessing the XORAYA external storage
unit
Power button (B)
When the DATACUBE is on, the power button illuminates green. Press the button twice shortly
to safely shut down the DATACUBE.
Reset button (C)
Press the reset button with a pointed object to restart the DATACUBE.
Power supply (D)
Use the provided power cord with AC adapter to connect the DATACUBE to the power supply.
Service LAN port (E)
In case of errors, this port is used as a debugging interface by the X2E support team.
USB 3.0 ports (F)
Perform a firmware update by using a USB flash drive containing the suitable ISO file.
1GbE (G) and 10GbE LAN ports (H)
Use these ports to connect the DATACUBE to a switch or directly to your PC.

User Manual XORAYA DATACUBE
8
The bold settings on the attached label indicate the default configuration:
RJ45 port LEDs:
LED Colour Meaning
Activity flashing yellow data is transferred
(off) no connection
Link speed orange 1 Gbit/s
green 100 Mbit/s for 1GbE ports
10 Gbit/s for 10GbE ports
(off) no connection or 10 Mbit/s

User Manual XORAYA DATACUBE
9
Installation
Connecting
CAUTION
Device damage due to overheating
Overheating may result in malfunction or destruction of the D
ATACUBE
.
Do not operate the DATACUBE in the vicinity of heat sources.
Ensure adequate air circulation.
Do not cover the DATACUBE with other objects.
CAUTION
Device damage due to wrong power supply
A wrong power supply can result in damage or destruction of the D
ATACUBE
.
Use the provided power cord with AC adapter to connect the
DATACUBE to the power supply.
Only connect the DATACUBE to power supplies that meet the specifi-
cations on the AC adapter label.
The power supply must provide a current of 10 A.
XORAYA external storage units
Connect up to six XORAYA external storage units via the provided cables to the ports
(A1-A6).
Tighten the connector screws.
PC/Switch
Connect PC or switch via a standard network cable to one of the ports (G-H).
Ensure proper connector seating.
Power supply
Connect the power cord with AC adapter to port (D).
Tighten the connector screws.
Connect the power cord to a power supply that meets the technical specifications.

User Manual XORAYA DATACUBE
10
XORAYASuite
The graphical user interface XORAYASuite is available to configure and to control the
DATACUBE.
Supported operating systems:
Microsoft® Windows® 7 (32 Bit or 64 Bit)
Microsoft® Windows® 8 (32 Bit or 64 Bit)
Microsoft® Windows® 10 (32 Bit or 64 Bit)
Hardware requirements:
Processor speed: at least 1 GHz
RAM: at least 2 GB
Hard disk space: approx. 120 MB available
Software requirements:
Microsoft® .NET Framework Version 4.5 or higher
Install XORAYASuite
Start the XORAYASuite installation wizard and follow the instructions on the screen.

User Manual XORAYA DATACUBE
11
Network settings
The XORAYASuite extra tool HWFinder enables access to a web interface to change the con-
figuration of the 1GbE (G) and 10GbE (H) LAN ports.
Start the XORAYASuite.
Click in the Windows notification area.
Select Extra tools > HWFinder.
Start web interface
In the drop-down list Device class, select DATACUBE
Double-click the row of the desired DATACUBE.
or
Highlight the row and click Web GUI.
The web interface opens in your browser.
Start web interface directly in browser
Alternatively, enter the IP address or the name of the DATACUBE directly into
the browser address bar to start the web interface.

User Manual XORAYA DATACUBE
12
In the menu on the left side, select the category Network configuration.
Click the desired port in the graphic.
or
Click one of the tabs Port A to Port D.
Activate the Editmode.
Change the Mode and enter IP address, Subnet mask and Standard gateway if
needed.
Click Save.

User Manual XORAYA DATACUBE
13
Operation
Download via Hdd-Control
The Hdd-Control tool allows downloading log data from XORAYA external storage units to the
PC.
Start the XORAYASuite.
Click Hdd-Control.
Connect DATACUBE
Connect the DATACUBE to power supply, PC and one or more XORAYA external stor-
age units (see chapter Connecting).
Turn on the power supply.
Press the power button (B).
The DATACUBE is ready when the power LED is green.
Click Display available loggers (1) to start scanning for dataloggers and DATACUBEs.
Select the desired DATACUBE.
Click Establish connection to logger (2).
or
In the Logger menu, click Connect.
The DATACUBE is connected with the Hdd-Control tool.
If only one XORAYA external storage unit is connected, it is automatically activated. Other-
wise, an additional window appears to display all six ports. The two columns and three rows
represent the physical arrangement on the DATACUBE.

User Manual XORAYA DATACUBE
14
Each cell contains for each connection or for each connected device:
port number (1-6)
connection date and time
configuration, consisting of four blocks: product ID, product variant, hardware revision
and serial number
percentage of used space
activate button
eject button
background colour depending on the state
white connected
blue activated
grey ejected or not connected
brown initialising
Activate XORAYA external storage unit
Click the activate button of the desired XORAYA external storage unit.
The sessions and measurements stored on the selected device are displayed.

User Manual XORAYA DATACUBE
15
To eject a XORAYA external storage unit safely or to activate another device, click Change
disk (5).
Via Settings (6) or the Settings command in the Download menu, you can configure that the
connection is automatically released after downloading.
There are different ways to select the log data to download.
Sessions and Measurements tabs
Select the check boxes in the Selected column.
or
Right-click to access the advanced selection options in the context menu.

User Manual XORAYA DATACUBE
16
Calendar tab
Displayed date and Zoom:
Filter the displayed measurements, for example, by default or streaming queue (a).
Specify a start date (b).
Choose between Week and Day (c) as the displayed time unit.
Click the single arrows (d) to jump one day or one week forward or backward.
Click the double arrows (e) to jump three days or three weeks forward or backward.
Click the graphical representation of a measurement (f) to select it.
or
Click and drag to select all measurements in this time range.
Select with date entry:
Specify start date and start time (g).
Specify end date and end time (h).
or
Enter the duration (i).
Click Apply selection (j).

User Manual XORAYA DATACUBE
17
Time range tab
Specify start date (a) and start time (b) of the desired time range.
Specify the end date (c). Use the arrows (d) optionally to apply the start date or to
jump one day forward or backward.
Specify the end time (e).
Click Apply (f).
Limit the time range further by clicking and dragging inside the graphical representa-
tion (g).
History
The time ranges defined since starting the tool can be selected again via the
History button (h).
Edit menu
Click Select all or Select none.

User Manual XORAYA DATACUBE
18
Download selected log data
Specify the export settings.
Specify the output formats.
Click Start download (4).
or
In the Download menu, click Start.
The selected sessions or measurements are transmitted to the PC.
Statistical data
Click the arrow behind Show download statistics (8) to switch between dif-
ferent statistics.
The symbol displays the current value during download and the average as
the process completes.
Click Show download statistics (8) to display statistical data graphically.
Cancel download
Click Stop download from logger (4).
or
In the Download menu, click Cancel.
Analyse log data
Click (7) to open the path last used in Windows Explorer.
After downloading into the X2E-Native output format, double-click the DLI file to open
the measurement with the Viewer tool.

User Manual XORAYA DATACUBE
19
Disconnect DATACUBE
Click Release connection to logger (2).
or
In the Logger menu, click Disconnect.
DATACUBE and Hdd-Control are disconnected.

User Manual XORAYA DATACUBE
20
Automatic download service
This XORAYASuite extra tool is a server, which automatically downloads log data from se-
lected DATACUBEs (and dataloggers).
Start the XORAYASuite.
Click in the Windows notification area.
Select Extra tools > DataCube.
Download settings
Click (3) to open the settings.
Table of contents
Popular Other manuals by other brands

Xerall
Xerall U-SCENE VR-2 user manual

ON Semiconductor
ON Semiconductor NCV78763 LDM A REFERENCE DESIGN KIT QUICK START GUIDE & SYSTEM OVERVIEW

ARETE
ARETE AB100 user guide

Zamel
Zamel PBM-01 instruction manual

Sony
Sony HCD-D270 - Compact Disk Deck Receiver Service manual

HYDRO GUARD
HYDRO GUARD HG-3 LongNeck User's operation manual