XRPlus IPC-300 User manual

IPC-300 User Manual
Safety Precaution
We appreciate your purchasing IPC series. Before installing the product,
please read the following with care.
Make sure to turn off the power before installing IPC.
Do not install under the direct sunlight or in dusty areas.
Make sure to use the product within the temperature and humidity specified in the
Do not operate the product in presence of vibrations or strong magnetic fields.
Do not put electrically conducting materials in the ventilation hole.
Do not open the top cover of the product. It may cause a failure or electric shock on
To prevent from overheating, make sure to keep the distance at least 10cm from the
Check for proper voltage before connecting the power.
specification.
the components.
ventilation hole.
-1-

IPC-300 User Manual
Table of Content
Table of Content..................................................................................................2
1. Introduction .....................................................................................................3
1. About User Manual..................................................................................3
2. Feature.....................................................................................................3
3. Product andAccessories.........................................................................4
4. Part Names and Functions......................................................................5
5. System Connections................................................................................6
2. Installation.......................................................................................................9
1. Connecting Network(LAN).......................................................................9
2. Connecting Audio.....................................................................................9
3. Connecting Serial Ports...........................................................................9
4. Connecting Sensor and Alarm.................................................................9
5. Connecting Power ...................................................................................9
6. Check if It Works......................................................................................9
3. System Operation .........................................................................................10
1. Remote Video Monitoring..................................................................10
2. Initialization of IPAddress..................................................................11
4. Remote Configuration...................................................................................11
1. Using Internet Explorer..........................................................................11
2. IPC Configuration ..................................................................................13
2.1 System Configuration...................................................................13
2.2 Video Configuration......................................................................15
2.3 Audio Configuration......................................................................18
2.4 Network Configuration..................................................................20
2.5 Serial Port Configuration ..............................................................22
2.6 Event Configuration......................................................................23
2.7 Preset Configuration.....................................................................25
2.8 User Configuration........................................................................27
2.9 Camera Configuration ..................................................................29
-2-

IPC-300 User Manual
1. Introduction
1. About User Manual
The User Manual is to provide information on operation of the high quality Network
Camera, IPC. In this guide, information on installation, operation, configuration of IPC is
written as well as how to trouble shoot in case problems arise.
2. Feature
IPC is a network camera and a video and audio surveillance transmission system based
on IP network through LAN, ADSL/VDSL, and Wireless LAN.
Video
-High-quality compression algorithm, H.264
-Compression in various resolution: CIF, Half-D1, D1
-Wide range of video transmission rate: 32kbps ~ 4Mbps
-Various transmission mode: CBR, VBR
-Motion detection
Audio
-Multi-transmission mode: Uni-direction (IPC -> Client PC or Decoder, Client PC
or Decoder -> IPC ), Bi-direction
Network
-Static IP and Dynamic IP(DHCP, PPPoE)
-One to one and one to many connection
-Multicasting
-Automatic transmit rate control according to network condition
Serial Data
-One serial ports (RS-485)
-Data pass-through mode: Serial data communication between IPC – Decoder
-3-

IPC-300 User Manual
Sensor and Alarm
-Connections to external sensor and alarm devices
-Event Alarm
User Interface
-System status display utilizing OSD(On Screen Display)
-System configuration using Internet Explorer
Reliability
-Reliable embedded system
-System recovery utilizing dual watch-dog functions
3. Product and Accessories
IPC System User Manual
-4-

IPC-300 User Manual
Power adaptor and cable CMS S/W CD
<Picture 1> Product and Accessories
4. Part Names and Functions
Mounting Hole
Dome Cover
Lockup Screw
Main Body
Mount Bracket
D
rop Prevention
Spring
Assemble
Reference Line
zMain Unit / Surface Mount Bracket
-5-

IPC-300 User Manual
DIP Switch
Cabling
Terminal Block
Drop Prevention
Spring Hook
E
thernet Connecto
r
Audio Connector
Power LED
IP Reset Switch
zBack of Main Unit
5. System Connections
IPC systems can be connected in either 1-to-1 fashion where one IPC is connected one
PC client or decoder system or 1-to-many fashion where one IPC connected to many
PC and decoder systems. (IPC -200 video server can work as a decoder system which
takes the data from a video server or IP camera, decodes and outputs analog video.)
Topology
Generally, the IPC and the PC & decoder are connected in 1-to-1 mode or 1-to-many
connection is also supported.
1:1 Connection (Unidirection)
IPC Decoder
Site Remote Center
IPC PC
Site Remote Center
-6-

IPC-300 User Manual
Mostly used configuration is 1 to 1 connection. An IPC is installed at a site where video
images can be transmitted and a PC or a decoder is installed at a center location to
receive and view the video images on analog monitor. Audio and serial data are
transferred in either direction.
1:N Connection (Unidirection)
IPC PC or Decoder
PC or Decoder
PC or Decoder
Remote Center
Site
In this configuration, a site can be monitored from many remote center locations.
Although up to 64 PCs or decoders can be connected to on IPC, in the real network
environment, network bandwidth can limit the maximum connections.
Functionally, the central monitoring system software can replace the decoder.
Multicast Mode
Within the network that supports multicasting, a large number of decoders can be used
to receive video effectively from an IPC using a single streaming of video and audio.
Relaying
IPC Decoder
Site Center 1
Decoder
Center 2
-7-

IPC-300 User Manual
In this arrangement, video and audio can be retransmitted from a center to another
center. The arrangement is useful when the network bandwidth to the site is limited
while there are more than one center wanting to monitor the site.
Central Monitoring System
Site Remote Center
IPC CMS
IPC Decoder
Site Remote Center
CMS
CMS (Central Monitoring System) is a Windows based remote monitoring program to
access multiple IPC for real-time monitoring or control of the encoders and connected
cameras. Please refer to CMS User Manual for more information on CMS.
-8-

IPC-300 User Manual
2. Installation
1. Connecting Network (LAN)
Connect LAN and there is a Video output to check video quality.
2. Connecting Audio
Audio is bi-directional in any configuration. If necessary, it can be configured to be in
transmit-only, receive -only or bi-directional mode.
- Connect audio input and output ports to audio devices accordingly.
- Audio signal is in line level, therefore, microphone or speaker with amplification
function should be used.
3. Connecting Serial Ports
The serial port(RS-485) in IPC can be connected to external equipment such as PTZ
receiver etc. Then, PC client can send PTZ commands to the external equipment via
serial port. When a decoder system instead of PC client is connected to IPC, the serial
port of IPC and that of the decoder system works in pass-through mode. That is, data at
one port are delivered to the other port, vice versa.
4. Connecting Sensor and Alarm
Connect sensor and alarm devices to corresponding terminals accordingly.
5. Connecting Power
After confirming the power source, connect power adaptor and connect the 12VDC
connector to the system. Soon the system will boot up to an operating mode.
6. Check if It Works
As soon as the power is supplied to the system, it will boot and, after about 30 seconds,
the system will be ready for operation.
-9-

IPC-300 User Manual
3. System Operation
1. Remote Video Monitoring
There are two ways to view the video once connections are made between the site and
center system. In order for a proper operation, an IP address must be set accordingly
and please refer to True Manager in Chapter 4 or Remote Setting in Chapter 5 for a
further details.
Default ID : admin Password : 1234
Video Monitoring with Decoder System
Once the IPC IP address is set in the remote IP address section of the decoder, the
decoder system will connect to the IPC and start receiving the video images. Normally,
a monitor connected to the decoder will display video images.
Video Monitoring using Internet Explorer
If an encoder’s IP address in entered on the Internet Explorer, the system will ask for
confirmation to install Active-X control. Once authorized, the Internet Explorer will start
to display video images from the encoder as shown below.
http://192.168.10.100
-10-

IPC-300 User Manual
2. Initialization of IP Address
If a system IP address is lost, the system can be reset to a known IP address using the
reset button in the back side of the system:
cWhile system is in operation, press the reset button more than 5 seconds.
dThe system will reboot automatically
eOnce the system has been rebooted, IP address will be set to the following.
-IP mode: Fixed IP
-IP address: 192.168.10.100
-Subnet mask: 255.255.255.0
-Gateway : 192.168.10.1
-Base port : 2222
-Http port : 80
4. Remote Configuration
1. Using Internet Explorer
The server can be configured using web browser. Type IP address of IPC in the address
input area of Internet Explorer, then a live viewing screen will be displayed. Press Setup
-11-

IPC-300 User Manual
button located in the upper right area of the monitoring screen, then the se page for
server setup will be displayed.
cEnter IP address
dPress Setup button
The configurations are grouped into 8 categories: System, Video, Audio, Network,
Serial, Event, Preset and User. Any configuration changes are not applied until Apply
is pressed. Leaving the page without pressing Apply button, changes in the page will be
discarded.
-12-

IPC-300 User Manual
2. IPC Configuration
2.1 System Configuration
Video Standard
Video signal type: Select NTSC or PAL
-13-

IPC-300 User Manual
System ID
System ID: Alphanumeric System ID to be transferred to remote software
Language
Language to be used for web-based configuration (English, Japanese and
Korean)
Firmware version
Current firmware version
Start Time
Latest system boot date and time
Current Time
Current date & time: Enter a new date and time and press Set Current Time
button to update date & time.
Time Zone
Time zone: Select time zone of where the system is installed. Depending on the
time zone, Daylight Saving Time will work automatically..
Automatically synchronize with NTP server
Synchronize system time with an NTP server using NTP (network time
protocol). Name of the NTP server should be registered on NTP server Name.
Reboot Server
Pressing Reboot Server button will cause the system to reboot. Do not press
the Reboot button unless the server needs a reboot.
Factory Reset
Set all settings to the factory default values. System log and user registrations
are also cleared.
-14-

IPC-300 User Manual
2.2 Video Configuration
-15-

IPC-300 User Manual
Preference
Preference in video compression and transmission: With ‘Bitrate’ selected,
the video compression will be effected by the ‘Bitrate’ value entered. With
‘Quality’ selected, the video compression will be effected by the quality of
image selected. Therefore, ‘Bitrate’ and ‘Quality’ corresponds to CBR and
VBR respectively.
Resolution
Selectable video compression resolution:
NTSC: 720X480, 720x240, 352X480, 352X240
PAL: 720X576, 720X288, 352X576, 352X288
Frame rate
Selectable video frame rate: Determine the maximum number of frames of
video images to compress. The frame rate of actually transmitted video
can be affected by the network bandwidth limitation.
Quality
Video image compression quality: The selection is possible with
Preference is set to ‘Quality’.
Bitrate
Video bitrate: The value is applicable when Preference is set to ‘Bitrate’.
-16-

IPC-300 User Manual
I-Frame Interval
I-frame interval: Possible values between 0 and 255. There will be no I-
frames if 0 is selected.
Motion Detection Area Editing
Configure regions for motion detection. Regions of arbitrary shape can be
configured by the following steps.
cEnable Edit item.
dSelect editing Mode. Set is for including cells to motion detection region
and Erase is for excluding.
eSelect cells using the right button of the mouse. Multiple cells can be
selected conveniently by press and dragging.
fPress Apply Edited Area to save the editing.
Sensitivity
A condition to trigger events with motion detection. The value determines
the sensitivity of the motion detection within a block: the smaller, the more
sensitive.
Information Display
System ID and/or server time can be display over the video window in
-17-

IPC-300 User Manual
Internet Explorer. Each item can be turn on or off separately, and position
also can be configure. This information are displayed after the video is
decompressed.
Burn-in OSD
Inserts system ID and date/time in the compressed video. Separately
System ID and Time can be turned On or Off in the video. Position
specifies the position of such data.
Brightness
Controls input video brightness by selecting values between 0 and 100.
Contrast
Controls input video contrast by selecting values between 0 and 100.
Hue
Controls input video Hue by selecting values between 0 and 100.
Saturation
Controls input video saturation by selecting values between 0 and 100.
2.3 Audio Configuration
-18-

IPC-300 User Manual
Mode
Select audio operation mode.
Mode Action
Off No operation
Tx-Only Transmit only
Rx-Only Receive only
Tx & Rx Transmit and Receive
Input Gain
Set audio input gain.
-19-
Table of contents
Other XRPlus Security Camera manuals
Popular Security Camera manuals by other brands

Denver
Denver IPO-1320MK2 manual

Advanced Technology Video
Advanced Technology Video CS7D37PB instruction manual

Vivotek
Vivotek IB8381 -E Quick installation guide

Axis
Axis AXIS 212 PTZ Specifications

Teledyne
Teledyne Piranha4 4K user manual

Luma Surveillance