Zennio QUAD Plus User manual

QUAD Plus
http://www.zennio.com Technical Support: http://support.zennio.com
2
CONTENTS
Contents ........................................................................................................................................ 2
1 Introduction .......................................................................................................................... 3
1.1 QUAD Plus ........................................................................................................................ 3
1.2 Installation........................................................................................................................ 3
2 Configuration......................................................................................................................... 5
2.1 General............................................................................................................................. 5
ETS Parameterisation.................................................................................................... 5
2.2 Inputs ............................................................................................................................... 6
2.2.1 Binary Input.............................................................................................................. 6
2.2.2 Temperature Probe.................................................................................................. 6
2.2.3 Motion Detector ...................................................................................................... 6
2.3 Thermostats ..................................................................................................................... 8
ANNEX I. Communication Objects................................................................................................. 9

QUAD Plus
http://www.zennio.com Technical Support: http://support.zennio.com
3
1INTRODUCTION
1.1 QUAD PLUS
QUAD Plus is an updated, small-size version of the popular QUAD from Zennio. This
module incorporates four digital / analogue separate inputs, each configurable as:
Binary Input.
Temperature probe, either models provided by Zennio or other NTC
temperature probes from other suppliers, being in that case possible to
configure their parameters in ETS.
Motion detector.
Moreover, QUAD Plus implements four independent thermostats, which can be
enabled and configured separately, as well as the Heartbeat function or periodical “still-
alive” notification.
1.2 INSTALLATION
QUAD is connected to the KNX bus through the incorporated terminal connector, while
the input lines need to be connected to QUAD Plus through the screw terminal block
bundled in the device packaging. Once powered through the KNX bus, the device may
be downloaded both an individual address or the application program.
Figure 1 QUAD Plus. Element diagram.
1.- Prog./Test LED.
2.- Prog./Test button.
3.- Inputs.
4.- Optional connector.
5.- KNX bus connector.
5
1
2
3
4

QUAD Plus
http://www.zennio.com Technical Support: http://support.zennio.com
4
The main elements are described next:
Prog./Test Button (2): a short press on this button sets the device into the
programming mode, making the associated LED (2) light in red. If this button
is held at the same time of applying bus power to the device, the device will
enter the Safe Mode. In such case, the LED will intermit in red.
Slots for the Input Lines (3): slots for the insertion of the optional inputs
terminal block (4). Alternatively, the stripped cables of the input lines can be
directly screwed into the slots. Each accessory should be connected to one of
the slots labelled 1 to 4 and, on the other hand, to any of the common slots,
labelled as “C”.
To obtain further information about the technical features of QUAD Plus and on
security and installation procedures, please refer to the Datasheet of the device,
bundled with the original packaging and also available at the Zennio website,
http://www.zennio.com.

QUAD Plus
http://www.zennio.com Technical Support: http://support.zennio.com
5
2CONFIGURATION
2.1 GENERAL
After importing the corresponding database in ETS and adding the device into the
topology of the desired project, the configuration process begins by right-clicking into
the device and selecting Edit parameters.
ETS PARAMETERISATION
The only parameterisable screen available by default is General. From this screen it is
possible to activate/deactivate all the required functionality.
Figure 2 General.
Heartbeat (Periodical Alive Notification): enables the “[Heartbeat] Object
to Send ‘1’” one-bit object, which will be sent with a value of “1” and a
configurable period to notify that the device is still working (still alive).
Input x: sets the type of input number “x”: “Binary Input”, “Temperature
Probe” or “Motion Detector”. If such input is not required, it can be left as
“Disabled”.
Thermostat x: enables or disables thermostat number “x”.
One entry per input or thermostat will be included into the tab tree on the left.

QUAD Plus
http://www.zennio.com Technical Support: http://support.zennio.com
6
2.2 INPUTS
QUAD Plus incorporates four analogue/digital inputs, each configurable as a:
Binary input, for the connection of a pushbutton or a switch/sensor.
Temperature probe, to connect a temperature sensor, either models
ZN1AC-NTC68 S/E/F and SQ-AmbienT from Zennio or NTC probes from
third parties (the latter requires configuring their parameters in ETS).
Motion detector, to connect a motion detector (models ZN1IO-DETEC-P and
ZN1IO-DETEC-X from Zennio).
Important: older models of the Zennio motion detector (e.g., ZN1IO-DETEC
and ZN1IO-DETEC-N) will not work properly with this device
2.2.1 BINARY INPUT
Please refer to the specific user manual “Binary Inputs”, available in the QUAD Plus
product section at the Zennio website, http://www.zennio.com.
2.2.2 TEMPERATURE PROBE
Please refer to the specific user manual “Temperature Probe”, available in the QUAD
Plus product section at the Zennio website, http://www.zennio.com.
2.2.3 MOTION DETECTOR
It is possible to connect motion detectors (models ZN1IO-DETEC-P and ZN1IO-
DETEC-X from Zennio) to the input ports of QUAD Plus. This brings the device with the
possibility of monitoring motion and presence in the room, as well as the light level.
Depending on the detection, different response actions can be parameterised.
Please refer to the “Motion Detector” user manual, available under the QUAD Plus
product section at the Zennio website (www.zennio.com), for detailed information about
the functionality and the configuration of the related parameters.

QUAD Plus
http://www.zennio.com Technical Support: http://support.zennio.com
7
Notes:
The ZN1IO-DETEC-P motion detector is compatible with a variety of Zennio
devices. However, depending on the device it is actually being connected to,
the functionality may differ slightly. Therefore, please refer specifically to the
aforementioned user manual.
Motion detectors with references ZN1IO-DETEC and ZN1IO-DETEC-N are
not compatible with QUAD Plus (may report inaccurate measurements if
connected to this device).
When connected to QUAD Plus, the rear micro-switch of model ZN1IO-
DETEC-P should be set to position “Type B”.

QUAD Plus
http://www.zennio.com Technical Support: http://support.zennio.com
8
2.3 THERMOSTATS
QUAD Plus allows independently enabling and configuring up to four thermostat
functions, with independence of the number of the inputs that have been configured.
Please refer to the specific “Zennio Thermostat” user manual available under the
QUAD Plus product section at the Zennio homepage (www.zennio.com) for detailed
information about the functionality and the configuration of the related parameters.

QUAD Plus
http://www.zennio.com Technical Support: http://support.zennio.com
9
ANNEX I. COMMUNICATION OBJECTS
“Functional range” shows the values that, with independence of any other values permitted by the bus according to the object size, may be of any use or have a particular meaning
because of the specifications or restrictions from both the KNX standard or the application program itself.
Number
Size
I/O
Flags
Data type (DPT)
Functional Range
Name
Function
1
1 Bit
C T - - -
DPT_Trigger
0/1
[Heartbeat] Object to Send '1'
Sending of '1' Periodically
2
1 Byte
I
C - - W -
DPT_SceneControl
0-63; 128-191
[Thermostat] Scene Input
Scene Value
3, 33, 63, 93
2 Bytes
I
C - - W -
DPT_Value_Temp
-273.00 -
670760.00
[Tx] Temperature Source 1
External Sensor Temperature
4, 34, 64, 94
2 Bytes
I
C - - W -
DPT_Value_Temp
-273.00 -
670760.00
[Tx] Temperature Source 2
External Sensor
Temperature
5, 35, 65, 95
2 Bytes
O
C T R - -
DPT_Value_Temp
-273.00 -
670760.00
[Tx] Effective Temperature
Effective Control Temperature
6, 36, 66, 96 1 Byte
IC - - W -
DPT_HVACMode
1=Comfort
2=Standby
3=Economy
4=Building
Protection
[Tx] Special Mode
1
-byte HVAC Mode
7, 37, 67, 97
1 Bit
I
C - - W -
DPT_Trigger
0/1
[Tx] Special Mode: comfort
0 = Nothing; 1 = Trigger
1 Bit
I
C - - W -
DPT_Switch
0/1
[Tx] Special Mode: comfort
0 = Off; 1 = On
8, 38, 68, 98
1 Bit
I
C - - W -
DPT_Trigger
0/1
[Tx] Special Mode: standby
0 = Nothing; 1 = Trigger
1 Bit
I
C - - W -
DPT_Switch
0/1
[Tx] Special Mode: standby
0 = Off; 1 = On
9, 39, 69, 99
1 Bit
I
C - - W -
DPT_Trigger
0/1
[Tx] Special Mode: economy
0 = Nothing; 1 = Trigger
1 Bit
I
C - - W -
DPT_Switch
0/1
[Tx] Special Mode: economy
0 = Off; 1 = On
10, 40, 70, 100
1 Bit
I
C - - W -
DPT_Trigger
0/1
[Tx] Special Mode: protection
0 = Nothing; 1 = Trigger
1 Bit
I
C - - W -
DPT_Switch
0/1
[Tx] Special Mode: protection
0 = Off; 1 = On
11, 41, 71, 101
1 Bit
I
C - - W -
DPT_Window_Door
0/1
[Tx] Window Status (input)
0 = Closed; 1 = Open
12, 42, 72, 102
1 Bit
I
C - - W -
DPT_Trigger
0/1
[Tx] Comfort Prolongation
0 = Nothing; 1 = Timed Comfort
13, 43, 73, 103 1 Byte
OC T R - - DPT_HVACMode
1=Comfort
2=Standby
3=Economy
4=Building
Protection
[Tx] Special Mode Status
1
-byte HVAC Mode

QUAD Plus
http://www.zennio.com Technical Support: http://support.zennio.com
10
14, 44, 74, 104 2 Bytes
I
C - - W -
DPT_Value_Temp
-273.00 -
670760.00
[Tx] Setpoint
Thermostat Setpoint Input
2 Bytes
I
C - - W -
DPT_Value_Temp
-273.00 -
670760.00
[Tx] Basic Setpoint
Reference Setpoint
15, 45, 75, 105
1 Bit
I
C - - W -
DPT_Step
0/1
[Tx] Setpoint Step
0 = -0.5ºC; 1 = +0.5ºC
16, 46, 76, 106
2 Bytes
I
C - - W -
DPT_Value_Tempd
-670760.00 -
670760.00
[Tx] Setpoint Offset
Float Offset Value
17, 47, 77, 107
2 Bytes
O
C T R - -
DPT_Value_Temp
-273.00 -
670760.00
[Tx] Setpoint Status
Current Setpoint
18, 48, 78, 108
2 Bytes
O
C T R - -
DPT_Value_Temp
-273.00 -
670760.00
[Tx] Basic Setpoint Status
Current Basic Setpoint
19, 49, 79, 109
2 Bytes
O
C T R - -
DPT_Value_Tempd
-670760.00 -
670760.00
[Tx] Setpoint Offset Status
Current Setpoint Offset
20, 50, 80, 110
1 Bit
I
C - - W -
DPT_Reset
0/1
[Tx] Setpoint Reset
Reset Setpoint to Default
1 Bit
I
C - - W -
DPT_Reset
0/1
[Tx] Offset Reset
Reset offset
21, 51, 81, 111
1 Bit
I
C - - W -
DPT_Heat_Cool
0/1
[Tx] Mode
0 = Cool; 1 = Heat
22, 52, 82, 112
1 Bit
O
C T R - -
DPT_Heat_Cool
0/1
[Tx] Mode Status
0 = Cool; 1 = Heat
23, 53, 83, 113
1 Bit
I
C - - W -
DPT_Switch
0/1
[Tx] On/Off
0 = Off; 1 = On
24, 54, 84, 114
1 Bit
O
C T R - -
DPT_Switch
0/1
[Tx] On/Off Status
0 = Off; 1 = On
25, 55, 85, 115
1 Byte
O
C T R - -
DPT_Scaling
0% - 100%
[Tx] Control Variable (Cool)
PI Control (Continuous)
26, 56, 86, 116
1 Byte
O
C T R - -
DPT_Scaling
0% - 100%
[Tx] Control Variable (Heat)
PI Control (Continuous)
27, 57, 87, 117
1 Bit
O
C T R - -
DPT_Switch
0/1
[Tx] Control Variable (Cool)
PI Control (PWM)
1 Bit
O
C T R - -
DPT_Switch
0/1
[Tx] Control Variable (Cool)
2-Point Control
28, 58, 88, 118
1 Bit
O
C T R - -
DPT_Switch
0/1
[Tx] Control Variable (Heat)
2-Point Control
1 Bit
O
C T R - -
DPT_Switch
0/1
[Tx] Control Variable (Heat)
PI Control (PWM)
29, 59, 89, 119
1 Bit
O
C T R - -
DPT_Switch
0/1
[Tx] Additional Cool
Temp >= (Setpoint+Band) => "1"
30, 60, 90, 120
1 Bit
O
C T R - -
DPT_Switch
0/1
[Tx] Additional Heat
Temp <= (Setpoint-Band) => "1"
31, 61, 91, 121
1 Bit
O
C T R - -
DPT_Switch
0/1
[Tx] PI State (Cool)
0 = PI signal 0%; 1 = PI signal greater than 0%
32, 62, 92, 122
1 Bit
O
C T R - -
DPT_Switch
0/1
[Tx] PI State (Heat)
0 = PI signal 0%; 1 = PI signal greater than 0%
123, 127, 131, 135
2 Bytes
O
C T R - -
DPT_Value_Temp
-273.00 -
670760.00
[I
x] Current Temperature
Temperature sensor value
124, 128, 132, 136
1 Bit
O
C T R - -
DPT_Alarm
0/1
[Ix] Overcooling
0 = No Alarm; 1 = Alarm
125, 129, 133, 137
1 Bit
O
C T R - -
DPT_Alarm
0/1
[Ix] Overheating
0 = No Alarm; 1 = Alarm
126, 130, 134, 138
1 Bit
O
C T R - -
DPT_Alarm
0/1
[Ix] Probe Error
0 = No Alarm; 1 = Alarm
139, 145, 151, 157
1 Bit
I
C - - W -
DPT_Switch
0/1
[Ix] Input Lock
1 = Locked; 0 = Unlocked
140, 146, 152, 158
1 Bit
C T - - -
DPT_Switch
0/1
[Ix] [Short Press] 0
Sending of 0
1 Bit
C T - - -
DPT_Switch
0/1
[Ix] [Short Press] 1
Sending of 1
1 Bit
I
C T - W -
DPT_Switch
0/1
[Ix] [Short Press] 0/1 Switching
Switching 0/1

QUAD Plus
http://www.zennio.com Technical Support: http://support.zennio.com
11
1 Bit
C T - - -
DPT_UpDown
0/1
[Ix] [Short Press] Move Up Shutter
Sending of 0 (Up)
1 Bit
C T - - -
DPT_UpDown
0/1
[Ix] [Short Press] Move Down Shutter
Sending of 1 (Down)
1 Bit
C T - - -
DPT_UpDown
0/1
[Ix] [Short Press] Move Up/Down Shutter
Switching 0/1 (Up/Down)
1 Bit
C T - - -
DPT_Step
0/1
[Ix] [Short Press] Stop/Step Up Shutter
Sending of 0 (Stop/Step up)
1 Bit
C T - - -
DPT_Step
0/1
[Ix] [Short Press] Stop/Step Down Shutter
Sending of 1 (Stop/Step down)
1 Bit
C T - - -
DPT_Step
0/1
[Ix] [Short Press] Stop/Step Shutter
(switched)
Switching of 0/1 (Stop/Step up/down)
4 Bit C T - - - DPT_Control_Dimming
0x0 (Stop)
0x1 (Dec. by
100%)
0x2 (Dec. by 50%)
0x3 (Dec. by 25%)
0x4 (Dec. by 12%)
0x5 (Dec. by 6%)
0x6 (Dec. by 3%)
0x7 (Dec. by 1%)
0x8 (Stop)
0x9 (Inc. by 100%)
0xA (Inc. by 50%)
0xB (Inc. by 25%)
0xC (Inc. by 12%)
0xD (Inc. by 6%)
0xE (Inc. by 3%)
0xF (Inc. by 1%)
[Ix]
[Short Press] Brighter
Increase Brightness
4 Bit C T - - - DPT_Control_Dimming
0x0 (Stop)
0x1 (Dec. by
100%)
…
0x8 (Stop)
0x9 (Inc. by 100%)
…
0xF (Inc. by 1%)
[Ix]
[Short Press] Darker
Decrease Brightness
4 Bit C T - - - DPT_Control_Dimming
0x0 (Stop)
0x1 (Dec. by
100%)
…
0x8 (Stop)
0x9 (Inc. by 100%)
…
0xF (Inc. by 1%)
[Ix]
[Short Press] Brighter/Darker
Switch Bright/Dark
1 Bit
C T - - -
DPT_Switch
0/1
[Ix] [Short Press] Dimmer ON
Sending of 1 (ON)
1 Bit
C T - - -
DPT_Switch
0/1
[Ix] [Short Press] Dimmer OFF
Sending of 0 (OFF)
1 Bit
I
C T - W -
DPT_Switch
0/1
[Ix] [Short Press] Dimmer ON/OFF
Switching 0/1

QUAD Plus
http://www.zennio.com Technical Support: http://support.zennio.com
12
1 Byte
C T - - -
DPT_SceneControl
0-63
[Ix] [Short Press] Run Scene
Sending of 0 - 63
1 Byte
C T - - -
DPT_SceneControl
128-191
[Ix] [Short Press] Save Scene
Sending of 128 - 191
1 Bit
I/O
C T R W -
DPT_Switch
0/1
[Ix] [Switch/Sensor] Edge
Sending of 0 or 1
1 Byte
C T - - -
DPT_Value_1_Ucount
0 - 255
[Ix] [Short Press] Constant Value (Integer)
0 - 255
1 Byte
C T - - -
DPT_Scaling
0% - 100%
[Ix] [Short Press] Constant Value
(Percentage)
0%
- 100%
2 Bytes
C T - - -
DPT_Value_2_Ucount
0 - 65535
[Ix] [Short Press] Constant Value (Integer)
0 - 65535
2 Bytes
C T - - -
9.xxx
-671088.64 -
670760.96
[Ix]
[Short Press] Constant Value (float)
Float value
141, 147, 154, 159
1 Byte
I
C - - W -
DPT_Scaling
0% - 100%
[Ix] [Short Press] Shutter Status (input)
0% = Top; 100% = Bottom
1 Byte
I
C - - W -
DPT_Scaling
0% - 100%
[Ix] [Short Press] Dimming Status (input)
0% - 100%
142, 148, 155, 160
1 Bit
C T - - -
DPT_Switch
0/1
[Ix] [Long Press] 0
Sending of 0
1 Bit
C T - - -
DPT_Switch
0/1
[Ix] [Long Press] 1
Sending of 1
1 Bit
I
C T - W -
DPT_Switch
0/1
[Ix] [Long Press] 0/1 Switching
Switching 0/1
1 Bit
C T - - -
DPT_UpDown
0/1
[Ix] [Long Press] Move Up Shutter
Sending of 0 (Up)
1 Bit
C T - - -
DPT_UpDown
0/1
[Ix] [Long Press] Move Down Shutter
Sending of 1 (Down)
1 Bit
C T - - -
DPT_UpDown
0/1
[Ix] [Long Press] Move Up/Down Shutter
Switching 0/1 (Up/Down)
1 Bit
C T - - -
DPT_Step
0/1
[Ix] [Long Press] Stop/Step Up Shutter
Sending of 0 (Stop/Step up)
1 Bit
C T - - -
DPT_Step
0/1
[Ix] [Long Press] Stop/Step Down Shutter
Sending of 1 (Stop/Step down)
1 Bit
C T - - -
DPT_Step
0/1
[Ix] [Long Press] Stop/Step Shutter
(switched)
Switching of 0/1
(Stop/Step up/down)
4 Bit C T - - - DPT_Control_Dimming
0x0 (Stop)
0x1 (Dec. by
100%)
…
0x8 (Stop)
0x9 (Inc. by 100%)
…
0xF (Inc. by 1%)
[Ix]
[Long Press] Brighter
Long Pr.
-> Brighter; Release -> Stop
4 Bit C T - - - DPT_Control_Dimming
0x0 (Stop)
0x1 (Dec. by
100%)
…
0x8 (Stop)
0x9 (Inc. by 100%)
…
0xF (Inc. by 1%)
[Ix] [Long Press] Darker
Long Pr.
-> Darker; Release -> Stop
4 Bit C T - - - DPT_Control_Dimming
0x0 (Stop)
0x1 (Dec. by
100%)
…
[Ix]
[Long Press] Brighter/Darker
Long Pr.
-> Brighter/Darker; Release -> Stop

QUAD Plus
http://www.zennio.com Technical Support: http://support.zennio.com
13
0x8 (Stop)
0x9 (Inc. by 100%)
…
0xF (Inc. by 1%)
1 Bit
C T - - -
DPT_Switch
0/1
[Ix] [Long Press] Dimmer ON
Sending of 1 (ON)
1 Bit
C T - - -
DPT_Switch
0/1
[Ix] [Long Press] Dimmer OFF
Sending of 0 (OFF)
1 Bit
I
C T - W -
DPT_Switch
0/1
[Ix] [Long Press] Dimmer ON/OFF
Switching 0/1
1 Byte
C T - - -
DPT_SceneControl
0-63
[Ix] [Long Press] Run Scene
Sending of 0 - 63
1 Byte
C T - - -
DPT_SceneControl
128-191
[Ix] [Long Press] Save Scene
Sending of 128 - 191
1 Bit
O
C T R - -
DPT_Alarm
0/1
[Ix] [Switch/Sensor] Alarm: Breakdown or
sabotage
1 = Alarm; 0 = No Alarm
2 Bytes
C T - - -
9.xxx
-671088.64 -
670760.96
[Ix]
[Long Press] Constant Value (float)
Float value
2 Bytes
C T - - -
DPT_Value_2_Ucount
0 - 65535
[Ix] [Long Press] Constant Value (Integer)
0 - 65535
1 Byte
C T - - -
DPT_Scaling
0% - 100%
[Ix] [Long Press] Constant Value
(Percentage)
0%
- 100%
1 Byte
C T - - -
DPT_Value_1_Ucount
0 - 255
[Ix] [Long Press] Constant Value (Integer)
0 - 255
143, 149, 156, 161
1 Bit
C T - - -
DPT_Trigger
0/1
[Ix] [Long Press/Release] Stop Shutter
Release -> Stop Shutter
144, 150, 157, 162
1 Byte
I
C - - W -
DPT_Scaling
0% - 100%
[Ix] [Long Press] Dimming Status (input)
0% - 100%
1 Byte
I
C - - W -
DPT_Scaling
0% - 100%
[Ix] [Long Press] Shutter Status (input)
0% = Top; 100% = Bottom
163
1 Byte
I
C - - W -
DPT_SceneControl
0-63
[Motion Detector] Scene Input
Scene Value
164
1 Byte
C T - - -
DPT_SceneControl
0-63
[Motion Detector] Scene Output
Scene Value
165, 194, 223, 252
1 Byte
O
C T R - -
DPT_Scaling
0% - 100%
[Ix] Luminosity
0-100%
166, 195, 224, 253
1 Bit
O
C T R - -
DPT_Alarm
0/1
[Ix] Open Circuit Error
0 = No Error; 1 = Open Circuit Error
167, 196, 225, 254
1 Bit
O
C T R - -
DPT_Alarm
0/1
[Ix] Short Circuit Error
0 = No Error; 1 = Short Circuit Error
168, 197, 226, 255
1 Byte
O
C T R - -
DPT_Scaling
0% - 100%
[Ix] Presence State (Scaling)
0-100%
169, 198, 227, 256 1 Byte
OC T R - - DPT_HVACMode
1=Comfort
2=Standby
3=Economy
4=Building
Protection
[Ix]
Presence State (HVAC)
Auto, Comfort, Standby, Economy, Building
Protection
170, 199, 228, 257
1 Bit
O
C T R - -
DPT_Occupancy
0/1
[Ix] Presence State (Binary)
Binary Value
1 Bit
O
C T R - -
DPT_Trigger
0/1
[Ix] Presence: Slave Output
1 = Motion Detected
171, 200, 229, 258
1 Bit
I
C - - W -
DPT_Window_Door
0/1
[Ix] Presence Trigger
Binary Value to Trigger the Presence Detection
172, 201, 230, 259
1 Bit
I
C - - W -
DPT_Trigger
0/1
[Ix] Presence: Slave Input
0 = Nothing; 1 = Detection from slave device
173, 202, 231, 260
2 Bytes
I
C - - W -
DPT_TimePeriodSec
0-65535
[Ix] Presence: Waiting Time
0-65535 s.
174, 203, 232, 261
2 Bytes
I
C - - W -
DPT_TimePeriodSec
1-65535
[Ix] Presence: Listening Time
1-65535 s.
175, 204, 233, 262
1 Bit
I
C - - W -
DPT_Switch
0/1
[Ix] Presence: Enable
According to parameters
176, 205, 234, 263
1 Bit
I
C - - W -
DPT_Switch
0/1
[Ix] Presence: Day/Night
According to parameters

QUAD Plus
http://www.zennio.com Technical Support: http://support.zennio.com
14
177, 206, 235, 264
1 Bit
O
C T R - -
DPT_Occupancy
0/1
[Ix] Presence: Occupancy State
0 = Not Occupied; 1 = Occupied
178, 207, 236, 265
1 Bit
I
C - - W -
DPT_Trigger
0/1
[Ix]
External Motion Detection
0 = Nothing; 1 = Motion detected by an external
sensor
179, 208, 237, 266
1 Byte
O
C T R - -
DPT_Scaling
0% - 100%
[Ix] [C1] Detection State (Scaling)
0-100%
180, 209, 238, 267 1 Byte
OC T R - - DPT_HVACMode
1=Comfort
2=Standby
3=Economy
4=Building
Protection
[Ix]
[C1] Detection State (HVAC)
Auto, Comfort, Standby, Economy, Building
Protection
181, 210, 239, 268
1 Bit
O
C T R - -
DPT_Switch
0/1
[Ix] [C1] Detection State (Binary)
Binary Value
182, 211, 240, 269
1 Bit
I
C - - W -
DPT_Switch
0/1
[Ix] [C1] Enable Channel
According to parameters
183, 212, 241, 270
1 Bit
I
C - - W -
DPT_Switch
0/1
[Ix] [C1] Force State
0 = No Detection; 1 = Detection
184, 213, 242, 271
1 Byte
O
C T R - -
DPT_Scaling
0% - 100%
[Ix] [C2] Detection State (Scaling)
0-100%
185, 214, 243, 272 1 Byte
OC T R - - DPT_HVACMode
1=Comfort
2=Standby
3=Economy
4=Building
Protection
[Ix]
[C2] Detection State (HVAC)
Auto,
Comfort, Standby, Economy, Building
Protection
186, 215, 244, 273
1 Bit
O
C T R - -
DPT_Switch
0/1
[Ix] [C2] Detection State (Binary)
Binary Value
187, 216, 245, 274
1 Bit
I
C - - W -
DPT_Switch
0/1
[Ix] [C2] Enable Channel
According to parameters
188, 217, 246, 275
1 Bit
I
C - - W -
DPT_Switch
0/1
[Ix] [C2] Force State
0 = No Detection; 1 = Detection
189, 218, 247, 276
1 Byte
O
C T R - -
DPT_Scaling
0% - 100%
[Ix] [C3] Detection State (Scaling)
0-100%
190, 219, 248, 277 1 Byte
OC T R - - DPT_HVACMode
1=Comfort
2=Standby
3=Economy
4=Building
Protection
[Ix]
[C3] Detection State (HVAC)
Auto, Comfort, Standby, Economy, Building
Protection
191, 220, 249, 278
1 Bit
O
C T R - -
DPT_Switch
0/1
[Ix] [C3] Detection State (Binary)
Binary Value
192, 221, 250, 279
1 Bit
I
C - - W -
DPT_Switch
0/1
[Ix] [C3] Enable Channel
According to parameters
193, 222, 251, 280
1 Bit
I
C - - W -
DPT_Switch
0/1
[Ix] [C3] Force State
0 = No Detection; 1 = Detection
Other manuals for QUAD Plus
1
Table of contents
Other Zennio I/O System manuals