manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ZepSolar
  6. •
  7. Rack & Stand
  8. •
  9. ZepSolar Comp User manual

ZepSolar Comp User manual

Other ZepSolar Rack & Stand manuals

ZepSolar ZS Span User manual

ZepSolar

ZepSolar ZS Span User manual

ZepSolar ZS Comp User manual

ZepSolar

ZepSolar ZS Comp User manual

Popular Rack & Stand manuals by other brands

Dynex DX-MP3MT Quick setup guide

Dynex

Dynex DX-MP3MT Quick setup guide

Konig & Meyer 24185 manual

Konig & Meyer

Konig & Meyer 24185 manual

ECG LD 326501 instruction manual

ECG

ECG LD 326501 instruction manual

Philips SB7S19S/00 quick start guide

Philips

Philips SB7S19S/00 quick start guide

Woodline KIT-250 lb instructions

Woodline

Woodline KIT-250 lb instructions

ricoo S1222 installation instructions

ricoo

ricoo S1222 installation instructions

Kanto P301 user manual

Kanto

Kanto P301 user manual

VidaBox VB MNT FFS2 installation guide

VidaBox

VidaBox VB MNT FFS2 installation guide

PROEL PLWIN60C user manual

PROEL

PROEL PLWIN60C user manual

AllMounts PLB-43S instruction manual

AllMounts

AllMounts PLB-43S instruction manual

VMP VH-001 instruction sheet

VMP

VMP VH-001 instruction sheet

Nederman SYSTEM 920/400 instruction manual

Nederman

Nederman SYSTEM 920/400 instruction manual

Glasdon ORBIS POST MOUNTING KIT installation guide

Glasdon

Glasdon ORBIS POST MOUNTING KIT installation guide

Songmics LGR105 manual

Songmics

Songmics LGR105 manual

Grape GM401 user manual

Grape

Grape GM401 user manual

FourStarGroup 11225296 manual

FourStarGroup

FourStarGroup 11225296 manual

CHIEF FLR100 installation instructions

CHIEF

CHIEF FLR100 installation instructions

FEC XDCAM EX PMW-EX30 manual

FEC

FEC XDCAM EX PMW-EX30 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

VERSION 1.3
Comp Mount
Installation Manual
Doc Number 801-00016, Version 1.3, Copyright © 2010 Zep Solar, Inc. PAGE:  2 of 3
ZEP SOLAR COMP MOUNT INSTALLATION GUIDE
Introduction
This guide provides instructions for installing Zep Solar’s Comp Mount flashed attachment assembly.
The Comp Mount is an OEM product manufactured by Quick Mount PV exclusively for Zep Solar. It
is intended for use on composition shingle roofs and combines high-quality waterproofing with a
labor-saving installation method. Prior to installing the Comp Mount, consult Zep Solar’s installation
resources found online at: http://www.zepsolar.com/resources.html. There you will find Span Tables
that will allow you to determine the maximum allowable spacing between attachment points. You
will also find the Zep System II PV Module Installation Manual, which provides full installation
instructions. Also consult www.QuickMountPV.com for general mounting instructions, tips, and FAQs.
INSTALLATION TOOLS REQUIRED: Tape Measure, Roofers Bar, Marking Crayon, Chalk Line,
Stud Finder, Torque Wrench, Caulking Gun, Rated Sealant, Drill with ⁷⁄₃₂" long bit, Drill or
Impact Gun with ½" Deep Socket.
Positioning the Comp Mount
Comp Mounts may be positioned with their lower edge between
1” below to 2.5” above the shingle course drip edge to accommo-
date the north-south (N-S) spacing of the attachment points (Fig.
1). See the formula (p. 3) to determine N-S spacing. The ability
to attach Zep Solar’s Leveling Foot to either of the two threaded
holes on the mounting block, and the adjust-ability allowed by
the oval slot of the Leveling Foot, enables additional N-S adjust-ability; eliminating the need to cut
the upper course of shingle in most every case. If the mounting block does come into conflict with
the upper shingle course, cut into the upper shingle course to allow the desired positioning.
Preparing the Roof
In the vicinity of the lower edge of the array, slide upper edge of
the first lower-row Comp Mount flashing base under a course
of shingles to the desired position (lower edge of the module
array will be 3" up-roof from the lower edge of flashing base).
Using a Roofer’s Bar, remove any nails that prevent the Comp
Mount from sliding into place. Mark the mounting-hole location
through the center hole of the Comp Mount, remove the Comp
Mount and drill a ⁷⁄₃₂" pilot hole into the center of the rafter
perpendicular to the roof pitch (Fig. 2). Clean off all saw dust
and fill with a sealant that is rated for the application (Fig. 3). Figure 2 Figure 3
LOWER EDGE OF SHINGLE COURSE
3 ½"
POSITIONING RANGE
Doc Number 801-00016, Version 1.3, Copyright © 2010 Zep Solar, Inc. PAGE:  3 of 3
ZEP SOLAR COMP MOUNT INSTALLATION GUIDE
Installing the Comp Mount
After preparing the roof, slide the first Comp Mount back into
position. Insert the provided lag screw with the provided seal-
ing washer into the hole and drive the screw into the rafter (Fig
4). Verify that the two holes in the mounting block are aligned
vertically. Then tighten the lag screw to 13 ft. lbs. Cover the lag
screw with the provided EPDM cap (Fig. 5). Repeat this step for
the remainder of the front row attachment points.
Positioning Subsequent Rows
Moving up roof, to determine the location of the next Comp
Mount, measure off the lower edge of the lower Comp Mount to
one of the 2 threaded holes on the upper Comp Mount (Fig 6).
See Mechanical Specifications below for threaded-hole loca-
tions. See the formula below to calculate the spacing based
on the orientation and module dimensions.
Figure 4
Figure 6
Figure 5
Figure 7
Landscape Orientation:
(Formulas for use with Type LFA Foot only)
Row 1 to Row 2:
Module Width + ⅝" + 3⅜"
Row 1 to Row X:
(X – 1) (Module Width + ⅝") + 3⅜"
Portrait Orientation:
(Formulas for use with Type LFA Foot only)
Row 1 to Row 2:
Module Length + ⅝" + 3⅜"
Row 1 to Row X:
(X – 1) (Module Length + ⅝") + 3⅜"
All additional rows should be measured off
the lower edge of the first-row mounting block
(Fig. 7) using the formula above to determine
the exact location of the Comp Mounts. Refer
to the Zep System II PV Module Installation
Manual for instructions on installing the Zep
Compatible module array.
2X 1.00
Threaded Holes
13.00
6.00
12.00
2x 5/16-18 UNCØ 4.00
2.50
EPDM Cap
1.30
Flashing Base
Lag Screw
Mounting Block