manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ZINK
  6. •
  7. Outdoor Light
  8. •
  9. ZINK ZN-35688 User manual

ZINK ZN-35688 User manual

Popular Outdoor Light manuals by other brands

Kichler Lighting HELEN 37536 instructions

Kichler Lighting

Kichler Lighting HELEN 37536 instructions

Thorn OXANE L installation instructions

Thorn

Thorn OXANE L installation instructions

esotec Solar Globe Light multicolor 20 operating instructions

esotec

esotec Solar Globe Light multicolor 20 operating instructions

mitzi HL200201 ELLIS Assembly and mounting instructions

mitzi

mitzi HL200201 ELLIS Assembly and mounting instructions

HEPER TILA S AFX 3 Module Installation & maintenance instructions

HEPER

HEPER TILA S AFX 3 Module Installation & maintenance instructions

Designplan TRON 180 installation instructions

Designplan

Designplan TRON 180 installation instructions

Sealey LED37 instructions

Sealey

Sealey LED37 instructions

nordlux VEJERS Mounting instruction

nordlux

nordlux VEJERS Mounting instruction

SImx ELITE LED LHTC637 installation instructions

SImx

SImx ELITE LED LHTC637 installation instructions

GEV CAROLINE 10833 manual

GEV

GEV CAROLINE 10833 manual

WE-EF PFL540 LED Installation and maintenance instructions

WE-EF

WE-EF PFL540 LED Installation and maintenance instructions

HEPER DOGO Side LW6048.585-US Installation & maintenance instructions

HEPER

HEPER DOGO Side LW6048.585-US Installation & maintenance instructions

BEGA 84 253 Installation and technical information

BEGA

BEGA 84 253 Installation and technical information

HEPER LW8034.003-US Installation & maintenance instructions

HEPER

HEPER LW8034.003-US Installation & maintenance instructions

HEPER MINIMO Installation & maintenance instructions

HEPER

HEPER MINIMO Installation & maintenance instructions

LIGMAN BAMBOO 3 installation manual

LIGMAN

LIGMAN BAMBOO 3 installation manual

Maretti TUBE CUBE WALL 14.4998.04 quick start guide

Maretti

Maretti TUBE CUBE WALL 14.4998.04 quick start guide

Maxim Lighting Carriage House VX 40428WGOB installation instructions

Maxim Lighting

Maxim Lighting Carriage House VX 40428WGOB installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

The product is an energy-saving automatic sensor lamp.
It can identify day and night. The lamp can be activated when someone enters the detection eld
and can turn o automatically when they leave the detection eld.
SPECIFICATION:
Power Source: 220-240V/AC Detection Range: 180°
Power Frequency: 50/60Hz Detection Distance: 5-12m(<24!)Adjustable
Ambient Light: <3-2000LUX (adjustable) Working Temperature: -20~+40!
Time Delay: Min.10sec±3sec Working Humidity: <93%RH
Max.5min±1min Installation Height: 1.8-2.5m
Rated Load: 20W (1500LM) Detection Moving Speed: 0.6-1.5m/s
FUNCTION:
The sensor can identify day and night: You can adjust working states in dierent ambient light.
It can operate during the daytime and at night when it is adjusted on the “sun” position (max).
It can operate in ambient light less than 3LUX when it is adjusted on the “moon” position (min).
As for making adjustments, please refer to the testing and troubleshooting sections of this manual..
SENS adjustable: It can be adjusted according to using location. The detection distance of low
sensitivity could be only 5m and high sensitivity could be 12m which ts for large room.
Time - When the unit receives another induction signal during its rst activation, it will restart
the timer from that moment, delaying the time it will shut down. This is added continually:
Adjustable Time Delay: the length of time delay could be set according to the customers’
requirement, the minimum time of this item is 10sec ± 3sec, the maximum is 5min±1min.
Good sensitivity Poor sensitivity
INSTALLATION:
Switch o the power.
Detatch the front of the tting by removing
the two locking screws. Open the wire
hole in the backplate and pass the mains wire
through the hole. (Ensure that the rubber seal
is tight around the wire.)
Secure the Backplate to the mounting surface using the screws provided.
Connect the mains wire into the terminal block according to the connection-wire diagram.
Re-attach the cover onto the backplate, taking care
not to trap any loose wiring.
Switch on the power and then you can test the tting.
The sensor head and two LED can tilt up/down,
turn left/right according to the customers’
requirement as the drawing shown right:
Instruction
INS ZN 35688 - D
Lynn 2 x 10W LED
With PIR Sensor
SENSOR INFORMATION:
TEST:
Turn the SENS knob clockwise on the
maximum (+). Turn the TIME knob
anti-clockwise on the minimum (-). Turn the
LUX knob clockwise on the maximum (sun).
Switch on the power; the lamp will have no
signal at the beginning. After Warm-up 30sec,
the lamp can start work. If it receives the
induction signal, the lamp will turn on. While there is no another induction signal any more, the
lamp should stop working within 10sec±3sec.
Turn LUX knob anti-clockwise on the minimum (moon). If the ambient light is more than 3LUX,
the lamp should not work. If you cover the detection window with the opaque objects (towel
etc), the lamp would work. Under no induction signal condition, the lamp should stop working
within 10sec±3sec.
Note: when testing in daylight, please turn LUX knob to (SUN) position, otherwise the
sensor lamp could not work!
NOTE:
Should be installed by electrician or experienced person;
Avoid installing it on an uneven surface;
There should be no hindrance and moving objects in front of the detection windows to aect
detection;
Avoid installing it near air temperature alteration zones such as air conditioning units,
central heating, etc;
If you have any issues after installation, please do not open the cover whilst it is still connected to
the live mains. If in any doubt consult a suitably qualied electrician.
The diagrams shown in this manual may dier slightly from the actual product supplied, but
functions and settings will remain the same.
SOME PROBLEM AND SOLVED WAY:
The load does not work:
a. Please check if the connection of power source and load is correct.
b. Please check if the load is good.
c. Please check if the settings of working light correspond to ambient light.
If the sensitivity is poor:
a. Please check if there is any hindrance in front of the detector to aect it to receive the
signals.
b. Please check if the ambient temperature is too high.
c. Please check if the induction signal source is in the detection eld.
d. Please check if the installation height corresponds to the height required in the
instruction.
e. Please check if the moving orientation is correct.
The sensor can not shut o the load automatically:
a. Please check if there is continual signal in the detection eld.
b. Please check if the time delay is set to the maximum position.
c. Please check if the power corresponds to the instruction.
Height of installation: 1.8-2.5m Detection Distance: Max.12m
CONNECTION-WIRE DIAGRAM:
HELPLINE
If you receive this item with parts broken or missing, please telephone: 0333 0050077
Please have ready your name, address, tel. no., product reference, where purchased and parts required.
An answering service is in operation outside office hours and during busy periods.
We regret that we are unable to give advice on internal house wiring.
This product should be disposed of responsibly at the end of its life. Please recycle
where facilities exist. Check with your Local Authority or retailer for recycling advice
(Waste Electrical and Electronic Equipment Directive)
Cascade Holdings Ltd, Gorse Mill, Gorse Street, Chadderton, Oldham. OL9 9RJ