SENSOR INFORMATION:
TEST:
Turn the SENS knob clockwise on the
maximum (+). Turn the TIME knob
anti-clockwise on the minimum (-). Turn the
LUX knob clockwise on the maximum (sun).
Switch on the power; the lamp will have no
signal at the beginning. After Warm-up 30sec,
the lamp can start work. If it receives the
induction signal, the lamp will turn on. While there is no another induction signal any more, the
lamp should stop working within 10sec±3sec.
Turn LUX knob anti-clockwise on the minimum (moon). If the ambient light is more than 3LUX,
the lamp should not work. If you cover the detection window with the opaque objects (towel
etc), the lamp would work. Under no induction signal condition, the lamp should stop working
within 10sec±3sec.
Note: when testing in daylight, please turn LUX knob to (SUN) position, otherwise the
sensor lamp could not work!
NOTE:
Should be installed by electrician or experienced person;
Avoid installing it on an uneven surface;
There should be no hindrance and moving objects in front of the detection windows to aect
detection;
Avoid installing it near air temperature alteration zones such as air conditioning units,
central heating, etc;
If you have any issues after installation, please do not open the cover whilst it is still connected to
the live mains. If in any doubt consult a suitably qualied electrician.
The diagrams shown in this manual may dier slightly from the actual product supplied, but
functions and settings will remain the same.
SOME PROBLEM AND SOLVED WAY:
The load does not work:
a. Please check if the connection of power source and load is correct.
b. Please check if the load is good.
c. Please check if the settings of working light correspond to ambient light.
If the sensitivity is poor:
a. Please check if there is any hindrance in front of the detector to aect it to receive the
signals.
b. Please check if the ambient temperature is too high.
c. Please check if the induction signal source is in the detection eld.
d. Please check if the installation height corresponds to the height required in the
instruction.
e. Please check if the moving orientation is correct.
The sensor can not shut o the load automatically:
a. Please check if there is continual signal in the detection eld.
b. Please check if the time delay is set to the maximum position.
c. Please check if the power corresponds to the instruction.
Height of installation: 1.8-2.5m Detection Distance: Max.12m
CONNECTION-WIRE DIAGRAM:
HELPLINE
If you receive this item with parts broken or missing, please telephone: 0333 0050077
Please have ready your name, address, tel. no., product reference, where purchased and parts required.
An answering service is in operation outside office hours and during busy periods.
We regret that we are unable to give advice on internal house wiring.
This product should be disposed of responsibly at the end of its life. Please recycle
where facilities exist. Check with your Local Authority or retailer for recycling advice
(Waste Electrical and Electronic Equipment Directive)
Cascade Holdings Ltd, Gorse Mill, Gorse Street, Chadderton, Oldham. OL9 9RJ