ZKT ZKSD3 Series User manual

1
User's Manual for ZKSD3 Series PTZ Dome IP Camera
About This Manual
This document mainly introduces the functional features, installation process and
access methods of ZKSD3 series IPC.
Version: V1.8
Date: July 2014

Important Claim
i
Firstly, thank you for purchasing this terminal, before use, please read this manual carefully to avoid the
unnecessary damage! The company reminds you that the proper user will improve the use affect and
authentication speed.
No written consent by our company, any unit or individual isn’t allowed to excerpt, copy the content of
this manual in part or in full, also spread in any form.
The product described in the manual maybe includes the software which copyrights are shared by the
licensors including our company, Except for the permission of the relevant holder, any person can’t copy,
distribute, revise, modify, extract, decompile, disassemble, decrypt, reverse engineering, leasing,
transfer, sub-license the software, other acts of copyright infringement, but the limitations applied to the
law is excluded.
To learn more, please visit our website www.zkivision.com or local office.
Important Claim
Due to the constant renewal of products, the company cannot undertake the actual
product in consistence with the information in the document, also any dispute caused
by the difference between the actual technical parameters and the information in this
document. Please forgive any change without notice.

User's Manual for ZKSD3 Series PTZ Dome IP Camera
I
1 Overview................................................................................................................................................. 1
1.1 Product Description........................................................................................................................ 1
1.2 Product Features............................................................................................................................ 1
1.3 Technical Parameters.................................................................................................................... 2
1.4 Product Appearance...................................................................................................................... 3
1.5 Connecting Terminal...................................................................................................................... 4
1.6 Basic Procedure............................................................................................................................. 6
2 Installation and Network Configuration.............................................................................................. 7
2.1 Hardware Installation..................................................................................................................... 7
2.2 Network Connection..................................................................................................................... 10
3 Accessing device................................................................................................................................ 11
3.1 Using WEB Browser .................................................................................................................... 11
3.2 Using RTSP Media Player........................................................................................................... 13
3.3 Using Mobile Devices .................................................................................................................. 14
3.4 Using Video Surveillance Software.............................................................................................. 16
4 Extended Functions............................................................................................................................ 18
Contents

1 Overview
1
1 Overview
1.1 Product Description
The ZKSD3 series products are high-speed dome IP cameras with CCD sensors, which are integrated with multiple new
technologies in mechanical, electronic and casting fields; they are high-performance integrative cameras with built-in
zoom lens and high-end surveillance products combining the platform and digital decoder design, which represent new
generation technologies. In virtue of arbitrary quick positioning and continuous tracking scan, the products implement the
genuine Omni-bearing surveillance without blind spot.
The series products are applicable for indoor and outdoor places where special surveillance is needed, such as prisons,
schools, factories and residence communities, etc, especially for open places, such as squares, roads and halls, as well
as moving targets.
1.2 Product Features
Appearance
Aluminum alloy housing
Double-layer protective cover design, and best dustproof, waterproof, anti-corrosion and high temperature resistant
capabilities
Built-in temperature control system, used for automatically adjusting temperature
Wire coming out from within, to better protect the wire
Interface
Double web indicator lamps for easy judgment of web status
Numerous additional functions, e.g. alarm, audio talkback, 485 control, TF card and reset, etc.
Analog video signal output interface
Functions of the system
1/4" Sony high-performance CCD used for sharp images
Driven by precision motor, featuring sensitive response and steady operation; precision deviation is less than 0.1
degree; images are free of jitter at any speed
Automatic identification of Pelco-P/D protocol under RS-485 control
No data loss in case of power-fail
Power-fail status memory; once the power is recovered, the system will automatically be back to the previous status
of the platform and lens
Built-in automatic temperature control system, used for automatically adjusting temperature
Lightning protection and surge protection
IP66 protection grade
Functions of the platform

User's Manual for ZKSD3 Series PTZ Dome IP Camera
2
360º continuous rotation in horizontal direction, -3º~90ºcontinuous rotation in vertical direction, surveillance without
blind zone
Maximum speed of horizontal preset point is up to 250º/s; maximum speed of vertical preset point is up to 100º/s
Horizontal keying speed is 0.1º~250º/s; vertical keying speed is 0.1º~100º/s
Support 256 preset positions
Support 8 cruise scans; 32 preset points can be added for each scan
Support 4 pattern scans; recording time of each path is more than 10 minutes
Support ratio zoom function; rotation speed can be automatically adjusted according to the zoom multiple
Performance
Hi3512 high-performance multimedia processor, supporting H.264 Main Profile video coding
The highest resolution of images is to D1 (704 * 576) resolution
Dual code stream, suitable for various networks
Support the browsing by 20 users simultaneously, 10 in primary code stream and 10 in secondary code stream
1.3 Technical Parameters
Product Name
18-multiple zoom high-speed dome IP camera
Product Model
ZKSD330
Cam Properties
Image Sensor
1/3" SONY CCD
Zoom Range
18-multiple optical zoom, 12-multiple electronic zoom
Minimum Brightness
0.1 Lux
Aperture
Automatic aperture; the electronic mode is preferential
Focus
Automatic focusing; the electronic mode is preferential
Video Coding
Primary Processor
Hi3512
Operating System
Embedded Linux
Video Compression Algorithm
H.264 main profile level 3
Audio Compression Algorithm
G.726/G.711
Video Compression Code Rate
Primary Code Stream: 32~512 Kbits/s adjustable
Secondary Code Stream: 32~256 Kbits/s adjustable
Video Resolution
Primary Code Stream: 704x576, 352x288, 176x144 optional
Secondary Code Stream: 352x288, 176x144 optional
Video Frame Rate
1~25 frames optional
Functional Interfaces
Audio Interface
1 Mic input and 1 linear output (optional)
Alarm Input
1 alarm input (normally opened or normally closed) (Optional)
Alarm Output
1 switch output, maximum working voltage: AC 120V/1A, DC 24V/1A
Motion Detection
Allow 4 independent detection areas
Memory
Support SD card for video storage and image capture, 32G maximum
(Optional)

1 Overview
3
Network Interface
10Base-T/100Base-TX Ethernet interface
Wi-Fi 802.11b/g wireless (optional)
Supported Network Protocols
TCP/IP, HTTP, TCP, ICMP, UDP, ARP, IGMP, SMTP, FTP, DHCP, DNS,
DDNS, NTP, UPNP and RTSP, P2P, etc.
PTZ
Horizontal Speed
0.1º~250º/s
Vertical Speed
0.1º~100º/s
Speed of Preset Position
Horizontal Speed: 100º/s
Vertical Speed: 250º/s
Automatic Scan Speed
1º~40º/s, which can be set up
Horizontal Rotation
360ºcontinuous rotation
Vertical Rotation
-3º~90ºrotation
Character Superposition
Display PTZ position and camera zoom information
Preset Position
255 preset positions and precision of preset positions is less than 0.1
degree
Scan Mode
Three scan modes: automatic /random/preset position cruise path
Limit Card
The scan limit and control limit can be set up
Preset Position Cruise
8 preset positions and the stay duration can be set up
Track Memory
2-track memory
Working Environment
Input Power
AC 24V, ≥2A
POE Ethernet power supply: comply with 802.3af regulation (optional)
Maximum Power Consumption
30W (without heater)
40W (with heater)
Working Temperature
-40~+55 C
Working Humidity
10%~85%RH
Level of Protection
IP66
Installation Mode
Wall-mounted / Pending mounted
net weight
4.5KG
1.4 Product Appearance
Dimensional Drawing (in mm)

User's Manual for ZKSD3 Series PTZ Dome IP Camera
4
1.5 Connecting Terminal
1. Power Interface: Used for connecting the power adapter. The voltage of series products is 24V AC and the current is
not lower than 2A. Other power is not allowed, in order to avoid damage of the cameras.
2. Network Interface: 10/100M self-adapting Ethernet interface is used to connect the camera with various network
equipments, such as, switch, router and hub. When it is connected to 10M network, the orange lamp is also on. When
it is connected to 100M network, the green lamp is always on.
3. Reset Button: When the camera fails to function during incorrect operation or accidental failure (e.g. forget IP
address or password), or it is used in different scenes, press down the button for above 5s after a delay of 30s from
powering on to restore the camera to its factory default. The default user’s name is "admin", the default password is
"admin" and the default IP address is "192.168.1.88".
4. Alarm Interface: Connect to alarm input and alarm output. When the camera receives an alarm from alarm output or
Web motion detection, this interface can send a signal to alarm output to realize real-time monitoring and overall
protection while triggering a remote alarm. The specific interfaces are presented in the following figure.
(1) The schematic diagram of alarm input connection is as follows:
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
IN
123 4 5
NC
COM
NO
GND Alarm input
Alarm output

1 Overview
5
Schematic Diagram of Alarm Input (Normally Opened) Connection
Schematic Diagram of Alarm Input (Normally Closed) Connection
Notice: When external alarm input is started, different alarm inputs have different software settings. Please select
"Normally Opened" or "Normally Closed" on the Web page according to the type of alarm input.
(2) The schematic diagram of alarm output default connection is as follows:
Schematic Diagram of Alarm Output (Normally Opened) Connection
Notice: The connection with normally opened alarm output (e.g. normally opened lock) is performed as shown in
the following schematic diagram.
Schematic Diagram of Alarm Output (Normally Closed) Connection
5. Reserved Interface: Reserved for other uses.
switch
(IN,GND)
alarm input
terminals alarm
input
device
power supply of
alarm input device
alarm input
terminals
(IN,GND) alarm
input
device
switch
power supply of
alarm input device
switch
(COM,NO)
alarm output
terminals alarm
output
device
power supply of
alarm output device
switch
(COM,NO)
alarm output
terminals alarm
output
device
power supply of
alarm output device

User's Manual for ZKSD3 Series PTZ Dome IP Camera
6
6. Audio Input Interface: connect to external audio acquisition (e.g. MIC) for sound acquisition.
7. Audio Output Interface: connect to audio player (e.g. active speaker) for sound broadcasting.
8. Analog Video Output Interface: special for SD camera and engineering commissioning. After being installed and
connected, this interface can be used locally to connect with the image display device and adjust the camera angle to
the appropriate monitoring area according to the scene in the video.
1.6 Basic Procedure
1. Unpack and check whether any component is missing.
2. Connect the camera to computer by means of patch cable.
3. If your computer IP is in a network section different from camera IP, please set it to the same network section as
camera IP, such as, 192.168.1.87.
4. Log in the camera through client software or browser to check whether the video functions normally.
5. Adjust the code stream and other video parameters.
6. Modify the network parameters of camera and reboot the device.
7. Repeat Step 3.
8. Revisit the camera through client software or browser to check till the video functions normally.
9. Install the camera and adjust the camera angle to the appropriate area.
10. Visit the camera through client software or browse for video monitoring.

2 Install and Network Configuration
7
2 Installation and Network Configuration
2.1 Hardware Installation
Installation Notices
1. Read through the guide for installation prior to installation.
2. Check whether any component is missing against the packing list, if yes, please contact your supplier.
3. Wire during power off. If the camera does not function normally during operation, please cut off the power before
check.
Notice: The wiring during power on may seriously damage the camera, which will be disqualified from the
guarantee.
4. Please use the power (voltage 24V AC and rating current no lower than 2A) provided by the factory for the
cameras. Much higher or lower voltage and direct current power may cause the camera failure.
5. Use the standard power cord when the power supply is too far away from the camera, and consider the voltage drop
caused by long distance.
6. Read through the instructions for connecting terminal and wire strictly according to interfaces. Any damage to the
camera due to improper operation will be disqualified from the guarantee.
7. All the exposed parts of connecting terminal should not exceed 5mm, in order to prevent any accidental contact from
damaging the camera.
Do not connect cables when power is on!
AC24V/2A

User's Manual for ZKSD3 Series PTZ Dome IP Camera
8
8. Mount the relay equipment in the middle to avoid signal attenuation when the straight communication distance from
the camera to the incoming equipment exceeds 80m.
9. Pay attention to provide lightning protection if the camera is mounted outdoor. Do not touch the camera during
lightning.
10. Use the camera in the working conditions:
Ambient temperature: -20 ℃~ +55 ℃; ambient relative humidity: 10% ~ 95%RH.
11. Please keep the lens and transparent cover clean. If the transparent cover is dirty, please wipe it with clean soft cloth.
12. Do not let the cameras aim at intense light source for long period of time, in order to avoid the CCD failure, which
results in no images or distorted images displayed.
13. The balls of the products feature best waterproof and damp-proof performance, which meet the requirement of IP66
standard. If the correct wiring mode is not used, the rain water will enter the core of the ball along the wire, to cause
short circuit of the control circuit board or even the damage of the camera. The correct and wrong wiring modes are
shown as follows:
Uncovered cable should be less than 5mm
Please use repeater when exceeding 80m

2 Install and Network Configuration
9
correct wiring
wrong wiring
Installation Diagram
Wall Mounted Mode:
Stick the installation template onto the wall, and drill holes according to the markings on the template.
Fix the bracket in wall by 4 screws.
steel M8
expansion bolt
Note: The method of Pendant Mounting is the same as Wall Mounting.

User's Manual for ZKSD3 Series PTZ Dome IP Camera
10
Paper template for pendant mounting Pendant mounting
2.2 Network Connection
The device can be connected to network in two ways. The first way is to connect to the network by means of Ethernet
cable, and the second way is to connect to wireless network (optional).
Connect by Ethernet Cable
1. Use Ethernet cables to connect the device to network or directly to computer.
2. Connect the power supply of the device.
3. During normal connection, if it is a 10M network, the orange lamp is always on; if it is a 100M network, the green lamp
is also on. The physical connection with network is completed after the lamp shining.
4. In the [Start] menu, select [Programs] > [Accessories] > [Command Prompt], and input the ping command to the
device address (e.g.: type in "ping 192.168.1.88"). If "Request timed out" does not pop up, the device is successfully
connected to network.
Notice:
1) The default IP address is "192.168.1.88" and the default HTTP port is 80. If needed to change IP address or port,
refer to Network Setting in WEB Server User Manual.
2) If the device is in a network section different from computer, refer to How to Visit IPC on Internet in WEB Server
User Manual for the connection during different network sections.
Connect to Wireless Network
Before starting the wireless network, connect the IPC to network by Ethernet cable, visit the device through browser, enter
"Network Setting" interface, and set the wireless network connection following the operating procedure, as detailed in
Network Setting in WEB Server User Manual.

3 Accessing Device
11
3 Accessing device
There are 4 methods can be used to access the device: WEB Browser, RTSP Media Player, Mobile Device and Video
Surveillance Software (ZKiVision client software).
3.1 Using WEB Browser
1. Start the browser. Enter the dynamic domain name or IP address (for example, http://192.168.1.88) in the address bar,
and press Enter. The following login interface is displayed.
2. Enter the User name and Password. (In initial state, both the User name and Password are "admin".) Click
button, then the following wizard is displayed.

User's Manual for ZKSD3 Series PTZ Dome IP Camera
12
3. Click Watch the Video to enter the preview interface where you can start video surveillance.
Note: If you use a browser to access the camera for the first time, you need to download the ActiveX. (To download
the ActiveX, click Install the Software (initial use), and follow instructions displayed on the ActiveX download window to
download and install the software.) For details about how to use a browser for video surveillance, see the Web
Surveillance User Manual, which is available on the disk delivered with the camera.

3 Accessing Device
13
3.2 Using RTSP Media Player
1. Download and install an RTSP-enabled player, such as the VLC media player.
2. Start the player and choose Media >Open Network Stream. A URL input interface is displayed.
3. Enter the network URL by using the format "rtsp://<IP address>:<RTSP Port>/<Stream code>".
For the network ULR shown in the following figure, "192.168.1.88" is the IP address, "554" is the RTSP Port, and "11" is
the Stream Code.
4. Click [Play]. Note: If the RTSP authentication is enabled on the camera, the RTSP Authentication dialog box is
displayed. Enter the User name and Password, as shown in the following figure. (By default, both the User name and
Password are "admin".)

User's Manual for ZKSD3 Series PTZ Dome IP Camera
14
5. After RTSP authentication is passed, the player plays the real-time videos collected by the camera.
Note:
(1) The RTSP Port of the camera is "554" by default. To change the default RSTP Port, see the section "Network Setup"
in the Web Surveillance User Manual, which is available on the disk delivered with the camera.
(2) To learn how to use the RTSP player for video surveillance, see the section "How to Use RTSP-Enabled Player for
Video Surveillance" in the Web Surveillance User Manual, which is available on the disk delivered with the camera.
3.3 Using Mobile Devices
Note:
(1) For the UID of a device, see the label on the back of the device.
(2) After successful connecting the device to the network, you can add the device in the ZKiVision (Mobile surveillance)
software in UID mode. After the device is added successfully, you can receive and browse surveillance videos on their

3 Accessing Device
15
mobile phones in real time by connecting their mobile phones to the front-end surveillance devices via a mobile wireless
network. (Tips: In an LAN, you can use any set of digits or letters to replace a UID; however, in a WAN, you must enter a
correct UID provided by your service provider.)
The following takes adding a device via an IP address as an example to illustrate how to access a device by using the
ZKiVision (mobile phone) monitoring software:
1. Download and install the ZKiVision (mobile phone) monitoring software ZKiVision Pro 2.0.apk or ZKiVision Pro
2.0.ipa from Google Play or Apple Store on your mobile phone.
2. Click the icon ZKiVision on the mobile device to start the video player. Figure 1 shows the initial interface of the
software.
3. Click . The Select Add way dialog box (see Figure 2). Select an option in the dialog box. The Add Device screen
will display (see Figure 3).
4. Specify device login information, including Name (device name), Address (IP address of the device), Port (P2P port of
the device, which is port 19888 by default), User (admin by default), and Password (123456 by default).
5. Click Sure button to save the configuration and return to the View Video screen, which displays the added device and
its channels (see Figure 4).
6. Select a device by clicking the device icon on the View Video screen (the selected device is highlighted in blue; see
Figure 5). The software checks and shows the number of channels of the device automatically.
7. Select a channel number (see Figure 5), which is then highlighted in blue. The View Video screen shows the
surveillance video of the channel in real time (see Figure 6). To close the video, click the corresponding channel number
(in blue)

User's Manual for ZKSD3 Series PTZ Dome IP Camera
16
Note:
(1) The operating system of the mobile device must be Android or iOS.
(2) Viewing videos will use data. For details about charges, consult your network service provider.
(3) Open the mobile phone monitoring software, and add a P2P-capable device by using a UID for remote view and
monitoring.
(4) Add a device by scanning a QR code, searching in an LAN, or manually entering a UID; see the ZKiVision User
Manual (Mobile Phone), which is available on the disk delivered with the camera.
3.4 Using Video Surveillance Software
ZKiVision Client Software is our company's free video surveillance software, which can help manage and monitor multiple
devices in a real-time manner. Install the software in the supplied CD, and add devices to the software. Then the real-time
monitoring can be started. If needed to learn about how to use the video surveillance software, refer to ZKiVision Client
Software User Manual in the CD.

3 Accessing Device
17
This manual suits for next models
1