  7. Rack & Stand
  8. •
  9. 3One data RACK2000A Operating and maintenance instructions

3One data RACK2000A Operating and maintenance instructions

RACK2000A
Ethernet Media Converter Rack
Quick Installation Manual
3onedata Co., Ltd.
Address:
3/B, Zone 1, Baiwangxin High Technology
Industrial Park, Song Bai Road, Nanshan
District, Shenzhen, 518108, China
Website:
www.3onedata.com
Tel:
+86 0755-26702688
Fax:
+86 0755-26703485
【Package Checklist】
Please check whether the package and accessories are intact
while using the Ethernet media converter for the first time.
1.
Ethernet media converter rack x 1
2.
Power cord
3.
Quick Installation Manual
4.
Certification
5.
Warranty card
If any of these items are damaged or lost, please contact our
company or dealers, we will solve it ASAP.
【Product Overview】
This product is an unmanaged 14 slots desktop Ethernet
media converter 2U rack. The model is RACK2000A (14 slots
desktop).
【Panel Design】
Front view
Rear view
Top view
1. Mounting lug
2. Slot position (place the desktop device)
3. Power supply module
【Mounting Dimension】
Unit: mm
Rack
Subset
Note before mounting:
Don't place or install the device in area near water or
moist, keep the relative humidity of the device
surrounding between 5%~95% without condensation.
Before power on, first confirm the supported power
supply specification to avoid over-voltage damaging the
device.
The device surface temperature is high after running;
please don't directly contact to avoid scalding.
【Rack Mounting】
Install the device
Step 1 Select the device installation location to reserve
sufficient size.
Step 2 Place the device on the surface plate of the rack,
and then adopt 4 screws to install the mounting
lugs on the left and right sides on the rack.
Step 3 Check and confirm the product is firmly installed
on the rack, then mounting ends.
Disassemble the device
Step 1 Device power off.
Step 2 Unscrew the fixing screw of mounting lug on the
rack.
Step 3 Remove the device from the rack, disassembling
ends.
【Optional Subset】
100M Ethernet media converter
1. Fiber port 100M rate indicator (100)
2. Copper port 100M rate indicator (100)
3. 100M fiber port
4. Fiber port connection status indicator (Link/Act)
5. Copper port connection status indicator (Link/Act)
6. Fiber port duplex mode indicator (FDX)
7. Power supply connection status indicator (PWR)
8. 100M copper port
9. DC5V power supply input end
Gigabit Ethernet media converter
1. Copper port 100M rate indicator (100)
2. Copper port connection status indicator (TP-TX)
3. Gigabit fiber port
4. Fiber port connection status indicator (FX)
5. Power supply connection status indicator (PWR)
6. Copper port gigabit rate indicator (1000)
7. Copper port duplex mode indicator (DUP)
8. Gigabit copper port
9. DC5V power supply input end
RS-232 interface fiber MODEL
1. Fiber port sending data indicator (TXD)
2. 100M fiber port
3. Power supply connection status indicator
4. Fiber port receiving data and connection alarm
indicator (RXD)
5. RS-232 serial port
6. DC5V power supply input end
RS-485/422 interface fiber MODEL
1. Fiber port sending data indicator (TXD)
2. 100M fiber port
3. Power supply connection status indicator
4. Fiber port receiving data and connection alarm
indicator (RXD)
5. RS-485/422 serial port
6. DC5V power supply input end
【RS-232 Serial Port】
The serial port of RS-232 interface fiber MODEL
adopts DB9 female connection mode, the pin
definition as follows:
Pin NO.
2
3
5
Pin definition
TXD
RXD
GND
【RS-485 Serial Port】
The serial port of RS-485/422 interface fiber
MODEL adopts 5-pin terminal blocks, the pin
definition as follows:
Pin NO.
1
2
3
4
5
RS-485
GND
-
-
D+
D-
RS-422
GND
R-
R+
T+
T-
【Power Supply Connection】
DC power supply
Professional communication power supply is
embedded in the rack, which supports dual
power supply optional. Dual power supply
device, when one power supply fails, it can
immediately switch to another power supply to ensure
the device continuous power supply. Power supply input
range: 100~260VAC.
【Indicator】
100M Ethernet media converter
Type
LED
Status
Description
Fiber
port
100
ON
100Mbps
OFF
10Mbps or out of service
Link/Act
ON
Fiber port link is well
connected
Blinking
Data is transmitted
OFF
Fiber port link is
disconnected
FDX
ON
Full duplex mode
Type
LED
Status
Description
OFF
Half duplex mode
Blinking
There exist conflicts
Copper
port
100
ON
100Mbps
OFF
10Mbps or out of service
LNK/ACK
ON
Ethernet port is well
connected
Blinking
Data is transmitted
OFF
Ethernet port link is
disconnected
Power
supply
PWR
ON
Power supply is normal
OFF
Power supply is not
powered or fails
Gigabit Ethernet media converter
Type
LED
Status
Description
Fiber
port
FX
ON
Fiber port link is well
connected
Blinking
Data is transmitted
OFF
Fiber port link is
disconnected
Copper
port
100
ON
100Mbps
OFF
10Mbps or out of service
1000
ON
1000Mbps
OFF
100Mbps or out of service
TP-TX
ON
Ethernet port is well
connected
Blinking
Data is transmitted
OFF
Ethernet port link is
disconnected
DUP
Blinking
Full duplex mode
OFF
Half duplex mode
Power
supply
PWR
ON
Power supply is normal
OFF
Power supply is not
Type
LED
Status
Description
powered or fails
RS-232 or RS-485/422 interface fiber MODEL
Type
LED
Status
Description
Fiber
port
RXD
ON
Without fiber connection
alarm
Blinking
Data is received
OFF
Without data receiving
TXD
ON
Data is transmitted
OFF
Without data transmission
Power
supply
PWR
ON
Power supply is normal
OFF
Power supply is not powered
or fails
【Specification】
Panel
Copper port
10/100Base-T (X) or
10/100/1000Base-T (X), RJ45
interface, full duplex/half duplex
self-adaptive
Fiber port
100Base-FX or 1000Base-FX
fiber port, full duplex SC/ST/FC
interface
Indicator
Power supply indicator, rate
indicator, duplex indicator,
copper port indicator, fiber port
indicator
Power supply
Input power supply
100~260VAC, 50~60Hz
Output power supply
5VDC
Consumption
Full-load power
< 60W
Working environment
Working temperature
0~50℃
Storage temperature
-10~70℃
Working humidity
5%~90% (no condensation)

Other 3One data Rack & Stand manuals

3One data RACK2000B User manual

3One data

3One data RACK2000B User manual

3One data RACK4000 Operating and maintenance instructions

3One data

3One data RACK4000 Operating and maintenance instructions

3One data RACK2100 Series User manual

3One data

3One data RACK2100 Series User manual

Popular Rack & Stand manuals by other brands

Opitec 116.208 quick start guide

Opitec

Opitec 116.208 quick start guide

Sanus Systems VisionMount MF203 manual&nbsp;

Sanus Systems

Sanus Systems VisionMount MF203 manual&nbsp;

Viega Eco Plus 8169.2 Instructions for use

Viega

Viega Eco Plus 8169.2 Instructions for use

Bora Portamate PM-2550 Assembly instructions

Bora Portamate

Bora Portamate PM-2550 Assembly instructions

ErGear EGSS1 instruction manual

ErGear

ErGear EGSS1 instruction manual

Novitool Pun M NDX 114 instructions

Novitool

Novitool Pun M NDX 114 instructions

Cyrus Hark III quick start guide

Cyrus

Cyrus Hark III quick start guide

Quartet INSTANT EASEL Assembly instructions

Quartet

Quartet INSTANT EASEL Assembly instructions

AvLab AVLT-DM26-1 installation manual

AvLab

AvLab AVLT-DM26-1 installation manual

Konig & Meyer Roadie manual

Konig & Meyer

Konig & Meyer Roadie manual

hecht 902 manual

hecht

hecht 902 manual

ricoo TS3411 Assembly instructions

ricoo

ricoo TS3411 Assembly instructions

Radium RaLUX UV-C manual

Radium

Radium RaLUX UV-C manual

Atdec VFS-DH installation guide

Atdec

Atdec VFS-DH installation guide

DeWalt DE7260 Original instructions

DeWalt

DeWalt DE7260 Original instructions

fully Fully Swivel CPU Holder Assembly instructions

fully

fully Fully Swivel CPU Holder Assembly instructions

Craftsman CMXMSAJ94773 instruction manual

Craftsman

Craftsman CMXMSAJ94773 instruction manual

Novopro LIG300 instruction manual

Novopro

Novopro LIG300 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.