DIP SWITCH OPERATION
HDCP Mode
Put switch 4 on “ON” position to select HDCP Active mode, or to “OFF” for HDCP Passive
mode.
5
Switch 1~3 are used for EDID setting. The DIP switch status and its corresponding setting
are shown at the back of the product.
Switch Status Video Resolution Audio Format
000
Obtain the EDID of output 1-4, then compare EDIDs and output the
highest level of video resolution and the lowest color space.
Example: If there is 4:4:4 and 4:2:0 color space, it will retain the 4:2:0 after
compare procession, and if there is 8K, 4K and 1080P, the machine will output
the 8K resolution.
Note: The output EDID supports up to 8K @ 60 4:2:0
001
Priority the EDID of output 1, when the output 1 EDID can’t read,
compare the output 2-4 EDIDs and then output the highest level of
video resolution and the lowest color space.
010 4K @ 60Hz 4:4:4 HDR DTS/Dolby
011 4K @ 120Hz 4:2:0 HDR LPCM
100 4K @ 120Hz 4:4:4 HDR DTS/Dolby
101 8K @ 30Hz 4:4:4 HDR DTS/Dolby
110 8K @ 60Hz 4:4:4 HDR DTS/Dolby
111 User Defined
6
EDID Upgrade
1. Connect the FW port on the front panel of the machine to be tested to the computer
with a USB Type-A to Type-C cable, and power on the machine to be tested;
2. Open the serial port tool on the computer, select the correct serial port number and
baud rate 115200, and power on the device under test;
3. Send the command > EDIDUpgrade first, and then select the EDID file to be uploaded
4. Click Upload. When you receive a successful feedback, it means that the EDID has
been uploaded successfully. Otherwise, please repeat the above steps.
HDCP Mode
Put switch 4 on “ON” position to select HDCP Active mode, or to “OFF” for HDCP
Passive mode.
Switch Status Mode HDCP
OFF (0) Passive
(Default) Automatically follows the input’s HDCP version.
ON (1) Active The HDCP supports up to 1.4 version; and if the input is
not HDCP, the output is also without HDCP.
Firmware Upgrade
Please follow the below steps to upgrade firmware by the FW port:
1. Connect the FW port on the front panel of the machine to the computer with an
appropriate USB cable, and power on the machine;
2. Open the stm32_upgrade.exe upgrade tool on the computer, select the correct serial
port number and baud rate 115200;
3. Click the Open button first, and then click the Connect button. The Connect button
turns green to indicate that it is connected, and the button turns to red to indicate
that the connection is not successful;
4. Click the OpenFile button to load the application layer corresponding to the machine,
and click the Upgrade button to start the upgrading procedure.
Note: 08009000 must be added after the firmware name to be recognized by this