ACE COMPUTERS PWKS1AA25UTRT User manual

PWKS1AA25UTRT, PWKS2AA25UTRT,
PWKS4AA25UTRT, PWKS1AA15PWTR,
and PWKS2AA15PWTR Servers
User Manual
Revision 1.0
Revision Date: 9.21.2021

ACE088 Page 2 of 21 Rev Date: 9.21.2021
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor
assumes no responsibility for any inaccuracies that may be contained in this document and makes no commitment
to update or to keep current the information in this manual, or to notify any person or organization of the updates.
Please Note: For the most up-to-date version of this manual, please see our website at www.acecomputers.com.
Ace Computers reserves the right to make changes to the product described in this manual at any time and without
notice. This product, including software and documentation, is the property of Ace Computers and/ or its licensors,
and is supplied only under a license. Any use or reproduction of this product is not allowed, except as expressly
permitted by the terms of said license.
IN NO EVENT WILL Ace Computers BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR
CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION,
EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPER MICRO COMPUTER, INC. SHALL
NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING
THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE,
OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Cook County in the State
of Illinois, USA. The State of Illinois, County of Cook shall be the exclusive venue for the resolution of any such
disputes. Ace Computer's total liability for all claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in an industrial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the manufacturer’s instruction
manual, may cause harmful interference with radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference, in which case you will be required to correct the interference at your
own expense.
The products sold by Ace Computers are not intended for and will not be used in life support systems, medical
equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency communication devices or
other critical systems whose failure to perform be reasonably expected to result in significant injury or loss of life or
catastrophic property damage. Accordingly, Ace Computers disclaims any and all liability, and should buyer use or
sell such products for use in such ultra-hazardous applications, it does so entirely at its own risk. Furthermore, buyer
agrees to fully indemnify, defend and hold Ace Computers harmless for and against any and all claims, demands,
actions, litigation, and proceedings of any kind arising out of or related to such ultra-hazardous use or sale.
Unless you request and receive written permission from Ace Computers, you may not copy any part of this
document. Information in this document is subject to change without notice. Other products and companies
referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
Printed in the United States of America
Note: This User Manual was derived from a SuperMicro User Manual, with permission from SuperMicro, to include
ACE Computers specific documentation.

ACE088 Page 3 of 21 Rev Date: 9.21.2021
Preface
About this Manual
This manual is written for professional system integrators and PC technicians. It provides information
pertaining to EPEAT for the ACE Computers EPEAT registered servers.
Notes
If you have any questions regarding this manual or server system, please contact our support team
through Ace Computers Support page https://acecomputers.com/support/ .This manual may be
periodically updated without notice.
Please check the Ace Computers website for possible updates to the manual revision level.

ACE088 Page 4 of 21 Rev Date: 9.21.2021
Table of Contents
Table of Contents
Chapter 1 - European Union (EU) Ecodesign Requirements ....................................................................5
Chapter 2 - Illustrated System Disassembly Instructions ........................................................................8
1. Data Storage Devices....................................................................................................................9
2. Memory.....................................................................................................................................10
3. Processor...................................................................................................................................11
5. Motherboard .............................................................................................................................12
6. Expansion Card/Graphics Card....................................................................................................13
7. Power Supply Module ................................................................................................................14
8. Chassis Cover .............................................................................................................................15
9. Batteries ....................................................................................................................................16
10. Riser Card............................................................................................................................... 17
11. Fans .......................................................................................................................................18
12. Back Plane.............................................................................................................................. 19
13. External Power Cable..............................................................................................................20
Chapter 3 –Product Take-Back, End-Of-Life Processing, and E-Waste Program ...................................21
Chapter 4 –Product Services ................................................................................................................21
4.1 Where to Get Replacement Components/Product Services..................................................... 21
4.2 Returning Merchandise for Service ...........................................................................................21

ACE088 Page 5 of 21 Rev Date: 9.21.2021
Chapter 1 - European Union (EU) Ecodesign Requirements
This chapter addresses European Union (EU) Ecodesign requirements for servers and storage products.
All data and ratings within this addendum are in reference only to the Ace Computers product(s) in the
manual. The below information conforms to requirements laid down in Annex II of the Commission
Regulation 2019/424.
3(1)(a): See Section 1.1 of the system manual for the product type.
3(1)(b): See the title page and preface of the system manual for the trademark and
manufacturer’s address.
3(1)(c): See the title page of the system manual for product model number(s).
3(1)(d): See the serial number on the physical system to determine the year of manufacture.
3(1)(e-j): PSU Efficiency and Power Factor Value (Table) (From 80 Plus report)

ACE088 Page 6 of 21 Rev Date: 9.21.2021
3(1)(k): The operating condition class is A2. Based on the results of testing, it was determined
that as long as the server functions inside the Allowable Range as noted for “Operating
Condition A2” (noted in the table below), there will be no material affect to the system and will
continue to operate as intended for the entire lifecycle of the product.
The life expectancy of the server system is eight year on average. If the server runs for 24 hours
a day, seven days a week for eight years, the operating hours that the server can operate in the
allowable range for class A2 without becoming materially affected would be 70,080 hours.
3(1)(l): The idle state power at the higher boundary temperature of the operating conditions
class is 331.9W.
3(1)(m): The active state efficiency and performance is 26.0.
3(1)(n): There are two methods by which a user can securely delete data from this system. The
user performing secure data deletion should be an IT professional.
The first is with a Unified Extensible Firmware Interface (UEFI) shell utility. This utility
works on X10/X11/H11/H12/M11 motherboard series with onboard SATA/NVMe
devices. Any user may access and download this utility through our trusted third party
vendor, following link:
https://www.supermicro.com/about/policies/disclaimer.cfm?url=/wftp/utility/Lot9_Sec
ure _Data_Deletion_Utility/
Download the shell utility package and extract it to a USB flash drive, then plug the drive
into the server for which secure data deletion is necessary. Then turn the system on.
Navigate to the BIOS setup menu, then place the server system into the UEFI shell
environment. Follow the instructions in the README file to invoke the utility and
complete the deletion.

ACE088 Page 7 of 21 Rev Date: 9.21.2021
The second method is through the secure data deletion tool provided by the original
manufacturer of the hard drive. This should be used in a scenario where the shell utility
is not applicable. Each manufacturer should have the tool available on their website. If
needed, please look on the hard drive label for the name of the manufacturer and
model information.
3(1)(o): List of recommended combinations of blade servers with chassis: N/A.
3(1)(p): List of all current SKUs within this product family.
SKUs
PWKS_AA25UTRT
PWKS_AA15PWTR
Models
PWKS1AA25UTRT
PWKS1AA15PWTR
PWKS2AA25UTRT
PWKS2AA15PWTR
PWKS4AA25UTRT
3(3)(a): There is no use of cobalt in batteries in this product.
The indicative weight range of neodymium in the HDD is 0.0 if manufactured by
Western Digital, and is between 5-25 grams if manufactured by Seagate.
3(3)(b): Please see the disassembly instructions on the next page.

ACE088 Page 8 of 21 Rev Date: 9.21.2021
Chapter 2 - Illustrated System Disassembly Instructions
Chapter 8 is intended to provide guidance to recyclers on the presence of materials and components at
the product/family level, per Article 15 of the EU WEEE Directive 2012/19/EU. The provided information
should also help direct recyclers to proper methods for removing parts and general product disassembly
instructions. This Chapter also outlines specific substances, mixtures, and components that must be
removed from any separately collected electronic waste component and shall be disposed or recovered
in compliance with Directive 2008/98/EC.
Please note: All the illustrations in the below disassembly instructions are for demonstration only. The
system and components shown in this section are a representative sample.
CAUTION: Always power off the system and unplug the power cord(s) first before disassembling the
system!
Representative Server Component Layout
Power Supply
Removeable
Hard drives
Motherboard
Fans
Processor
Memory (4X)

ACE088 Page 9 of 21 Rev Date: 9.21.2021
1. Data Storage Devices
Location: Servers are best known for their storage and interchangeability, this is most commonly
done through front hard drive bays as noted in the photo below. Some servers may also have
SSD storage, this type of storage can be found on the motherboard. It generally lays flat, parallel
to the board, rather than at a right angle. Most common applications insert one end of the SSD
into a slot on the motherboard while the alternate end is held in place with a small screw.
Type and number of fastenings: HDD = One (1) latch and four (6) Phillips screws, SSD = (1)
Phillips screw.
Tools required: Screwdriver with PH2 bit.
Procedure:
HDD = Push the release button on the carrier. Swing the handle fully. Grasp the handle and pull
the drive carrier out of its bay, once the drive carrier is out of the bay, the Phillips screws can be
removed.
SSD = Identify the SSD on the motherboard, remove the screw, and pull straight back in a
parallel position to remove the SSD from the slot on the motherboard.
Selective Treatment/Special Handling Per Annex VII, Directive 2012/19/EU: Any printed circuit
boards within the data storage devices must be removed separately from the data storage
devices and shall be disposed or recovered in compliance with Directive 2008/98/EC.
Step 1 Step 2

ACE088 Page 10 of 21 Rev Date: 9.21.2021
2.Memory
Location: Memory modules are found on the motherboard of the server, the number of memory
modules may vary by unit configuration but are generally found in pairs of 2.
Type and number of fastenings: Two (2) latches per memory module.
Tools required: None.
Procedure: Press both release tabs on the ends of the memory module to unlock it. Once the
module is loosened, remove it from the memory slot.
Selective Treatment/Special Handling Per Annex VII, Directive 2012/19/EU: Any printed circuit
boards within the memory must be removed separately from the memory and shall be disposed
or recovered in compliance with Directive 2008/98/EC.

ACE088 Page 11 of 21 Rev Date: 9.21.2021
3. Processor
4. Location: The processor is found on the motherboard of the server. As shown in the photo
below, the processor is located under the heat sink. The heatsink can look more like a fin type
thermal transfer device, or a rotating fan with a thermal transfer plate. There can be more than
one processor per motherboard, generally between 1- 4.
Type and number of fastenings: Four (4) T30 Torx screws.
Tools required: Screwdriver with T30 Torx bit.
Procedure: Remove the screws in the sequence of 4, then 3, then 2, then 1, as marked in the
illustration below. After removing the screws, lift the processor heatsink module off the
processor socket. Unsnap corners A and B, then C and D of the latch. Push the latch out from the
bottom.
Selective Treatment/Special Handling Per Annex VII, Directive 2012/19/EU: Any printed circuit
boards within the processor must be removed separately from the processor and shall be
disposed or recovered in compliance with Directive 2008/98/EC.

ACE088 Page 12 of 21 Rev Date: 9.21.2021
5. Motherboard
Location: The motherboard is the largest PCB in the server configuration, it is generally centrally
located within the unit. Standard practice would be to remove all the components, peripherals,
and add-ons from the motherboard before removal of the motherboard for processing.
Type and number of fastenings: 14 Phillips screws.
Tools required: Screwdriver with PH2 bit.
Procedure: Remove all 14 Phillips screws. Lift the motherboard from its base.
Selective Treatment/Special Handling Per Annex VII, Directive 2012/19/EU: Any printed circuit
boards within the motherboard must be removed separately from the motherboard and shall be
disposed or recovered in compliance with Directive 2008/98/EC.
A lithium battery resides on the motherboard. The battery must be removed separately from
the motherboard and shall be disposed or recovered in compliance with Directive 2008/98/EC.
Refer to section 9 for specific instructions on remove and disposal of LiON batteries.
▪Handle used batteries carefully. Do not damage the battery in any way; a
damaged battery may release hazardous materials into the environment. Do not
discard a used battery in the garbage or a public landfill. Please comply with the
regulations set up by your local hazardous waste management agency to
dispose of your used battery properly.

ACE088 Page 13 of 21 Rev Date: 9.21.2021
6. Expansion Card/Graphics Card
Location: Certain configurations of server may include a riser card bracket, this component
allows for utilization of the vertical space in a server, rather than only utilizing the horizontal
space. It is used for add-on types of components; it is attached directly to the motherboard. The
riser card would generally be populated, and the components integrated should be removed
prior to processing the riser card component.
Type and number of fastenings: Six (6) Phillips screws.
Tools required: Screwdriver with PH2 bit.
Procedure: Remove the Phillips screws. Open the rear window latch and carefully remove the
expansion card from the riser card slot, lifting it up and away from the system.
Selective Treatment/Special Handling Per Annex VII, Directive 2012/19/EU: Any printed circuit
boards within the expansion card/graphics card must be removed separately from the
expansion card/graphics card and shall be disposed or recovered in compliance with Directive
2008/98/EC.

ACE088 Page 14 of 21 Rev Date: 9.21.2021
7. Power Supply Module
Location: The power supply module is an interchangeable unit, and can be removed with ease
from the exterior, rear, portion of the server chassis. Many servers are equipped with redundant
power supplies (at least 2) in some instances there may be more than 2 power supplies
depending on the configuration.
Type and number of fastenings: One (1) latch per module.
Tools required: None.
Procedure: Unplug the power cord from the power supply. Push the release tab on the back of
the power supply module to the side and pull the module straight out.
Selective Treatment/Special Handling Per Annex VII, Directive 2012/19/EU: Any printed circuit
boards within the power supply module must be removed separately from the power supply
module and shall be disposed or recovered in compliance with Directive 2008/98/EC.

ACE088 Page 15 of 21 Rev Date: 9.21.2021
8. Chassis Cover
Location: The chassis cover is located on the upright, top side of the server, and it approximately
2/3 the size of the entire top, as noted in the illustration below.
Type and number of fastenings: Two (2) buttons.
Tools required: None.
Procedure: Hold down the two buttons simultaneously while pushing away the top cover.
Selective Treatment/Special Handling Per Annex VII, Directive 2012/19/EU: None

ACE088 Page 16 of 21 Rev Date: 9.21.2021
9. Batteries
Location: The battery is located on the motherboard, see illustration below.
Type and number of fastenings: One (1) latch.
Tools required: None.
Procedure: Push aside the small clamp that covers the edge of the battery. When the battery is
released, lift it out of the holder.
Selective Treatment/Special Handling Per Annex VII, Directive 2012/19/EU: A lithium battery
resides on the motherboard. The battery must be removed from separately from the
motherboard and shall be disposed or recovered in compliance with Directive 2008/98/EC.
Removal instructions for the motherboard lithium battery are outlined below.
▪Handle used batteries carefully. Do not damage the battery in any way; a damaged battery may
release hazardous materials into the environment. Do not discard a used battery in the garbage
or a public landfill. Please comply with the regulations set up by your local hazardous waste
management agency to dispose of your used battery properly.

ACE088 Page 17 of 21 Rev Date: 9.21.2021
10. Riser Card
Location: The riser cards are located towards the rear of the server chasis, see illustration noted
below.
Type and number of fastenings: One (1) Phillips screw.
Tools required: Screwdriver with PH2 bit.
Procedure: Remove the screw and lift the riser card up from the motherboard expansion slot.
Selective Treatment/Special Handling Per Annex VII, Directive 2012/19/EU: Any printed circuit
boards within the riser card must be removed separately from the riser card and shall be
disposed or recovered in compliance with Directive 2008/98/EC.

ACE088 Page 18 of 21 Rev Date: 9.21.2021
11. Fans
Location: Most servers are equipped with a number of fans, this configuration includes no less
than 4 fans. See illustration noted below for location within the server chassis.
Type and number of fastenings: One (1) fan header per fan.
Tools required: None.
Procedure: Disconnect the fan wiring from the fan header on the motherboard. Then remove
the fan from the fan tray.
Selective Treatment/Special Handling Per Annex VII, Directive 2012/19/EU: Any plastic
components within the fan must be removed separately due to the presence of brominated
flame retardants and shall be disposed or recovered in compliance with Directive 2008/98/EC.

ACE088 Page 19 of 21 Rev Date: 9.21.2021
12. Back Plane
Location: The backplane of the servers is located between the fans and drive bays towards the
front of the server chassis. See the illustration noted below.
Type and number of fastenings: twelve (12) screws for PWKS_AA25UTRT series and
PWKS_AA15PWTR series.
Tools required: Screwdriver with PH2 bit.
Procedure: Disconnect all cables. Remove all Phillips screws to release and remove the
backplane.
Selective Treatment/Special Handling Per Annex VII, Directive 2012/19/EU: Any printed circuit
boards within the backplane must be removed separately from any other supporting/structural
components and shall be disposed or recovered in compliance with Directive 2008/98/EC.

ACE088 Page 20 of 21 Rev Date: 9.21.2021
13. External Power Cable
Location: To power the server a power cable is required. The cable may be separate or attached
via a server rack mount power delivery system. The external power cable may be dual ended
with an outlet and inlet of the same plug configuration type or one end may be a plug type
connection. Configurations may vary. If the server is fully configured, the power supply cord
would be connected to the power supply outlet located on the rear of the server chassis. Note:
there are two power supplies per unit, so be aware for two power supply cords.
Type and number of fastenings: None, direct pressure connection method.
Tools required: None.
Procedure: Disconnect the external power cable from the main server assembly.
Selective Treatment/Special Handling Per Annex VII, Directive 2012/19/EU: Any external
electrical cables > 25mm must be removed separately and shall be disposed or recovered in
compliance with Directive 2008/98/EC.
This manual suits for next models
4
Table of contents
Other ACE COMPUTERS Server manuals
Popular Server manuals by other brands

TAG
TAG SV-2003-X2 Operation manual

Snap Appliances
Snap Appliances snap server 2000 Administrator's guide

GFI
GFI FaxMaker Getting started guide

Dell
Dell PowerEdge C8000 Hardware owner's manual

Lenovo
Lenovo ThinkServer RD330 Anweisungen zur Installation im Gehäuserahmen

Fujitsu
Fujitsu Primergy RX100 S5 operating manual