ActronAir WC-02 Operating instructions

IMPORTANT NOTE:
Please read this manual carefully before installing or operating your wired remote controller. Make sure to save this manual
for future reference.
Copy/
Follow me
Back/TurboConrmDay o/DelTimerSwing
OWNER’S MANUAL
INSTALLATION &
Universal Wired Remote Controller
Model Number:
WC-02
That’s better. That’s Actron.

1. Safety Precaution..................................................................................... 3
2. Installation Components......................................................................... 4
3. Installation Method................................................................................. 5
4. Specification............................................................................................ 10
5. Wired Controller Features and Functions................................................ 11
6. Wired Controller Display......................................................................... 12
7. Wired Controller Buttons........................................................................ 13
8. Preparatory Operation............................................................................ 14
9. Operation................................................................................................ 15
10. Timer Functions .................................................................................... 20
11. Weekly Timer........................................................................................... 23
12. Fault Alarm Handing ............................................................................... 30
Table of Contents
Installation and Owner’s Manual
Page 2

Page 3
1. Safety Precautions Wired Remote Controller
WARNING
• Carefully read the Safety Precautions before installation. Adhere to this installation manual.
• Only trained and qualified HVAC technicians should install, repair and service this air conditioning unit, strictly follow the
installation instructions set forth in this manual. Improper installation may result in electrical shock, short circuit,
leaks, fire or other damage to the equipment and personal property.
• Reinstallation must be performed by a qualified service technician.
WARNINGS FOR PRODUCT USE
• DO NOT install the unit in a place vulnerable to leakage of flammable gases. If flammable gases leak or linger around the
wired controller, fire may occur.
• CODES, REGULATIONS, AND STANDARDS
The installer/contractor assumes responsibility to ensure that the installation complies with the releveant council,
state/federal codes, regulations and building code standards. All electrical wiring must be in accordance with current
electrical authority regulations and all wiring connections to be as per the electrical diagram/s provided with the unit.
This manual gives detailed description of the precautions
that should be brought to your attention during operation.
To ensure the correct service of the wired controller
read this manual carefully before using the unit.
Keep this manual after reading for future reference.
This manual is a controlled document which contains confidential and proprietary information.
Distribution, modification, copying and/or reproduction are prohibited without written consent from ActronAir
Product design and specifications are subject to change without prior notice for product improvement.
Read Safety Precautions Before Installation
Thank you for purchasing this air conditioner. This manual will provide you with information on how to operate, maintain,
and troubleshoot your air conditioner. Following the instructions will ensure the proper function and extended lifespan of
your unit.
Please pay attention to the following signs:
WARNING
Failure to observe a warning may result in death or serious injury. The
appliance must be installed in accordance with national regulations.
Failure to observe a caution may result in injury or equipment damage.
MUST BE INSTALLED BY A
LICENSED ELECTRICIAN
D I Y
DIY
DIY
ALL ELECTRICAL WORK
MUST BE PERFORMED
BY A LICENSED ELECTRICIAN
FOR COMPLIANCE WITH
QUEENSLAND ELECTRICAL SAFETY
REGULATIONS 2002
This refers to electrical works only

Page 4
2. Installation Components Wired Remote Controller
Precaution for the installation of the wired controller
1. This manual provides the installation method for the wired controller. Please refer to the wiring diagram in this
installation manual to wire the wired controller with the indoor unit.
2. The wired controller uses extra-low voltage (ELV) only. DO NOT connect to low voltage 230VAC circuits or wiring as
damage to wired controller will result. Maintain correct separations between ELV wiring and other 230VAC mains
wiring.
3. The shielded wire of the wired controller must be properly grounded, see wiring diagram.
4. Upon finalising the wired controller connection, do not use an ohmmegger test to check the insulation.
No. Name Qty Remarks
1Wired controller 1 -
2Installation and owner’s manual 1 -
3Screws 3 M4X20 (for mounting on the wall)
4Wall plugs 3 For mounting on the wall
5Screws 2 M4X25 (for mounting on switch box)
6Plastic screw bars 2 For fixing on switch box
7Battery 1
8connecting cables 2

Page 5
1. Wired remote controller dimensions
3. Installation Method Wired Remote Controller
Fig 3.1

Page 6
3. Wiring Connection For Wall Splits
2. Wiring Connection Diagram for Cassettes & Ducted
1. Connect wired controller to indoor unit mainboard using the connecting cables included. Connect the adaptor cable
(smaller cable) first to the indoor main board. Then connect the wired controller using the longer connecting cable.
Fig 3.2
1. Open the front panel , identify the multi function box (See Fig.3.3.1).
2. Cut the terminal of the longer connection cable (See Fig 3.3.2).
3. Connect the four wires to each of the pins in the multi function board as follows:
The red wire on wire controller connect to 12/5V pin on multi function board; black wire to E pin; yellow wire to Y pin;
brown wire to X pin. (See Fig.3.3.1).
Fig 3.3.2
Fig 3.3.1 When connecting to
4-core wired controller:
12V = Red
E = Black
Y = Yellow
X = Brown
3. Installation Method Wired Remote Controller
Wired Controller Multi-function board
Connecting cable
Wired Controller Insert of the mainboard CN40
Indoor Unit
Mainboard
Connecting cable
4-core shielded cable
CN40
adaptor cable

Page 7
4. Wire controller - Removing the upper part
3. Installation Method Wired Remote Controller
Insert a flat screwdriver into the slots in the lower part of the wire controller (2 places).
Remove the upper part of the wire controller (Fig.3.4)
Fig 3.4
NOTE
The PCB is mounted in the upper part of the wired
controller. Be careful not to damage the board with the
screwdriver.
NOTE
Place on a flat surface. Be careful not to distort the wire
controller’s back plate by over−tightening the mounting
screws.
5. Fasten the wire controller back plate
For surface mounting, fasten the back plate on the wall with the 3 screws (M4x20) and plugs. (Fig.3.5)
Fig 3.5

Page 8
Place the battery in the unit and ensure the positive side of the battery is in accordance with the polarity markings.
(See Fig.3.7)
Set the correct time before operating. Batteries in the wired controller can maintain the correct time during a power
failure. When the power is restored and the displayed time is not correct, replace the battery.
There are three methods:
1. from the rear;
2. from the bottom;
3. from the top;
4. Notch the part for the wiring to pass through with a nipper tool.
6. Battery installation
3. Installation Method Wired Remote Controller
Fig 3.7
Fig 3.8
7. Wiring the indoor unit
31
2
NOTE
DO NOT allow water to enter the remote control.
Use a water loop and silastic to seal the wires.
Silastic
Silastic
Silastic
Loop
Loop
Loop

Page 9
3. Installation Method Wired Remote Controller
Fig 3.9
8. Reattach the wire controller’s upper part
While adjusting and mounting the upper case, avoid clamping the wiring during installation. (Fig 3.9)
IMPORTANT: All the pictures in this manual are for
illustration purposes only.
Your wire controller may differ slightly.

Page 10
Wiring Specifications
4. Specification Wired Remote Controller
Input Voltage DC 12V
Ambient Temperature 5ºC~43ºC
Ambient Humidity RH40%~RH90%
Wiring Type Size Total Length
Shielded PVC or cable
0.75mm2 20m
1.5mm2 50m
Wiring Specifications

Page 11
Feature and Function of the Wired Controller
5. Feature and Function Wired Remote Controller
Feature:
LCD display.
Malfunction code display: displays the error code
(helpful for servicing)
4-way wire layout design.
Room temperature display.
Weekly Timer
Function:
Mode: choose Auto-Cool-Dry-Heat-Fan
Fan speed: Auto-Low-Med-High
Swing (on Wall Split and Cassettes)
Timer ON/OFF
Temp setting
Weekly Timer
Follow me
Child Lock
LCD Display
Clock
Elevating Panel Function (on Cassettes only)

Page 12
Wired Controller Display
6. Display Wired Remote Controller
1. Operation mode indicator
2. Fan speed indicator
3. Left-right swing indicator
4. Up-down swing indicator
5. Elevating Panel Function indicator
6. Main unit and secondary unit indicator
7. Follow me function indicator
8. Turbo/Auxiliary Heat function indicator
9. °C indicator
10. Temperature display
11. Lock indicator
12. Room temperature indicator
13. Clock display
14. On/Off timer
15. Timer display

Page 13
Wired Controller Buttons
7. Buttons Wired Remote Controller
1. Mode
2. Power
3. Adjust
4. Fan Speed
5. Swing
6. Timer
7. Day Off/Del
8. Copy/Follow me
9. Back/Turbo
10. Confirm

Page 14
1. Press TIMER for 3s or more. The timer displays flashes.
2. Press +or −to set the date. The selected date flashes.
3. Date setting is complete and the time setting is ready after pressing TIMER or if nothing is pressed in 10 seconds.
4. Press +or −to set the current time. Press repeatedly to adjust the current time in 1 minute increments. Press and
hold to adjust the current time.
5. The setting is complete after pressing TIMER or if no button is pressed for 10 seconds.
Set the current Day and Time
8. Preparatory Operation Wired Remote Controller

Page 15
To Start/Stop Operation
To Set The Operation Mode (operating mode setting)
Room Temperature Setting
9. Operation Wired Remote Controller
Press the Power Button
Press MODE to set the operation mode.
Press +or -to set the room temperature.
Indoor Setting Temperature Range: (17~30°C).

Page 16
Fan Speed Setting
9. Operation Wired Remote Controller
Press FAN SPEED to set the fan speed.
NOTE: This function is unavailable in the AUTO or DRY modes
Room Temperature Sensor Selection
Press FOLLOW ME to select whether the room temperature is detected at the indoor unit or at the wired controller.
NOTE: When the FOLLOW ME function indication appears, the room temperature is detected at the wire remote
controller.
Child Lock Function
Press LOCK for 3 seconds to activate the CHILD LOCK feature and lock all buttons on the wired controller.
Press again for 3 seconds to deactivate.
NOTE: When the child lock function is activated, the lock image appears.

Page 17
9. Operation Wired Remote Controller
Turbo
Press TURBO to activate/deactivate the Turbo function.
The turbo function sets the unit to reach the user’s present temperature in the shortest amount of time possible.
When the user presses TURBO, the unit sets to the highest fan speed setting to jump−start the cooling / heating
process.
Elevating Panel Function (only for Cassette models)
1. When the unit is off Press the MODE button long to activate the lift panel function.
The mark will flash.
2. Press the button +and -to control the lift and drop of the panel.
Pressing the +button can stop the panel, while it is dropping.
Pressing the -button can stop the panel, while it is lifting.
Keypad Tone Setting
Press SWING and TIMER simultaneously for 3 seconds to disable the keypad tone.
Press the buttons again for 3 seconds to enable the keypad tone.

Page 18
Up-Down airflow direction and swing
Use SWING to adjust the up and down airflow direction
1. Every time the user presses SWING, the louvre swings six degrees.
2. Press and hold SWING for 2 seconds, it changes to the UP−DOWN SWING mode. Press SWING again to stop.
When the Up-Down swing function is activated,the mark appears. (Not applicable to all the models)
The operation can refer to the following instructions for the unit with four Up-Down louvres can be operated
individually.
1. Press the SWING button to activate the Up-Down adjusting louvre function.
The mark will flash. (Not applicable to all the models)
2. Pressing the button “+” or“-” can select the movement of four louvres.
Each time you push the button,the wire controller select in a sequence that goes from:
(the icon means the four louvres move at the same time.)
3. And then use SWING button to adjust the Up-Down airflow direction of the selected louvre.
Swing Function (for Cassette models)
9. Operation Wired Remote Controller

Page 19
1. Up-Down swing
Press the Swing button to start up-down swing function.
Press it again to stop.
When the Up-Down swing function is activated,the mark appears.
2. Left-Right swing
Press the Swing button long to start Left-Right swing function.
Press it again to stop.
When the Left-Right swing function is activated, the mark appears.
9. Operation Wired Remote Controller
Swing Function (for Wall Split models)

Page 20
Timer Overview
10. Timer Functions Wired Remote Controller
Weekly Timer
Use to set the operating times for each day of the week.
On Timer
Use to start the air conditioner operation.
The timer operates and the air conditioner operation starts after the time has passed.
Off Timer
Use to stop the air conditioner operation.
The timer operates and the air conditioner operation stops after the time has passed.
On and Off Timer
Use to start and stop the air conditioner operation.
The timer operates and the air conditioner operation starts and stops after the time has passed.
Table of contents