Advantech TREK-120 Series User manual

User Manual
for
LEO-S Cold Chain Management
(TREK-120 & USM-S62)
V1.2

Contents
Contents..............................................................................................................................2
Chapter 1 General Information........................................................ 1
1.1 Introduction....................................................................................................2
1.2 General Specification.....................................................................................2
1.3 Installation flowchart ......................................................................................3
Chapter 2 System Setup.................................................................. 4
2.1 A Quick Tour of the LEO-S CCM Hardware Kit –TREK-120G2.....................5
2.1.1 Outlook..................................................................................................5
2.1.2 LED behavior.......................................................................................5
2.1.3 Mounting Methods...............................................................................5
2.1.4 Battery Replacement..........................................................................6
2.2 A Quick Tour of LEO-S CCM Hardware Kit –USM110-S62...........................7
2.2.1 Outlook..........................................................................................................7
2.2.2 LED behavior.................................................................................................8
2.2.3 Mounting Methods .........................................................................................8
Chapter 3 Software Demo Utility Setup.......................................... 9
3.1 USM-S62 EdgeX-Go installation..................................................................10
3.2 Web-GUI......................................................................................................14
3.2.1 Login....................................................................................................14
3.2.2 Overview..............................................................................................14
3.2.3 Firmware Check & Update Method.....................................................16
3.2.3.1 USM-S62 Firmware Version Check....................................................16
3.2.3.2 USM-S62 Firmware Update Method...................................................17
3.2.3.3 LoRa Module Firmware Version Check..............................................19
3.2.3.4 LoRa Module Firmware Update Method.............................................20
3.2.4 USM-S62 Change Network ID (Unavailable feature).........................23
3.2.5 Insert Node List....................................................................................24
3.2.6 TREK-120 Connection Confirm..........................................................27
3.2.7 Cellular Network Setting (LTE version)..............................................27
3.2.8 Wi-Fi Network Setting (WLAN version) ............................................27
3.3 LEO-S TREK-120G2 Configuration Tool (Need TREK-120-ANR)................28
3.3.1 Basic Settings.......................................................................................31
3.3.2 Sensor Data..........................................................................................33
3.3.3 Upload backup data to Dash board......................................................37
3.3.4 WISE-PaaS Setting..............................................................................38
3.4 WISE-PaaS Dashboard Demo.....................................................................38

1
Chapter 1 General Information

2
1.1 Introduction
Advantech Cold Chain Management offer a full function of Temperature and
Humidity control analysis in supply chain. This LEO-S CCM Kit can apply in
many environments such as hypermarket, food factory, museum, warehouse,
medical management, etc. For use with us in-vehicle gateway, our LEO-S can
achieve Uninterrupted Real-time Cold Chain Management.
This LEO-S CCM kit content USM-S62 as gateway install inside the building, and
TREK-120G2 as sensor in every container or any place need temperature
management.
1.2 General Specification

3
1.3 Installation flowchart

4
Chapter 2 System Setup

5
2.1 A Quick Tour of the LEO-S CCM Hardware Kit –TREK-120G2
2.1.1Outlook
Figure 1 Front View of TREK-120G2
Figure 2 Back View of TREK-120G2
2.1.2LED behavior
Power/Status LED
Alarm LED
Standby
Green
N/A
Recording
Green
Green
Low Battery
Red
N/A
Over Critical
Green
Red
2.1.3Mounting Methods
Figure 3 Three Different Mounting Methods of TREK-120G2
Sensor
Start/Status Button
Power/Status LED
Alarm LED
Battery Cover
NFC Antenna
Mounting
Powerful magnet
3MTM VHBTM Tape
Screws

6
2.1.4Battery Replacement
Step 1. Release 4 Screws on battery cover
Step 2. Open battery cover
Step 3. Take off the battery
Step 4. Install the new battery
Figure 4 Replace battery of TREK-120
Note: NFC function is only Rx

7
2.2 A Quick Tour of LEO-S CCM Hardware Kit –USM110-S62
2.2.1Outlook
Figure 5 USM-S62 LTE/Wi-Fi Antenna Side View
Figure 6 USM-S62 Lo-Ra Antenna Side View
Figure 7 USM-S62 Card Socket View
RJ-45 Network Socket
12.0V⎓2.0A Adapter socket
LTE/Wi-Fi Conductor
LTE/Wi-Fi Conductor
USB 2.0 Socket
Lo-Ra Conductor
Lo-Ra Conductor
Micro SD Card Socket
Micro SIM Socket

8
2.2.2LED behavior
Figure 8 LED Behavior of USM-S62
Left LED
Right LED
Power On
Green
Blue
Initializing
Green Orange Cross
N/A
Ready
Orange
N/A
2.2.3Mounting Methods
Figure 9 Mounting Method of USM-S62
Screws
Screws

9
Chapter 3 Software Demo Utility Setup

10
3.1 USM-S62 EdgeX-Go installation
EdgeX-Go Overview
Before we run EdgeX-Go on USM-S62 we must prepare at least 4GB memory size
micro SD card. And stored three files into the micro SD card
Edgex-go
USM-S62
Edgex_installer
Edgex-go provide an environment for USM-S62 program, and the program will collect
MQTT data from Lo-Ra antenna, final upload to WISE-PaaS. Edgex_installer is a
program for automatically start EdgeX service and USM-S62 program.
After we insert micro SD card, and power on USM-S62 device. We need to set our IPv4
Net-ID as same as USM-S62 but different Host-ID and also same subnet mask of
network socket on our laptop/PC.
Management IP address
172.0.0.1
Mask address
255.255.255.0
Open “Network & Internet”, and click “Ethernet”.

11
And will show Ethernet configuration interface. Choose “Change adapter options”.
Right click chooses “Properties”.
Roll down “The connection uses the following items:”, will find Internet Protocol
Version 4 (TCP/IPv4), then double click it.

13
Open PuTTY Session with IP address 172.0.0.1
The login user name and password default is root and 1234
And we go to location /mnt/mmc, this location is where the micro SD card located.
Syntax
root@USM-S62:~#
cd /mnt/mmc
Display
Now let’s executed edgex_installer.
Syntax
root@USM-S62: /mnt/mmc#
./edgex_installer
Display
Final, it will display two tips to point out install finish.

14
3.2 Web-GUI
3.2.1Login
Open your browser (Chrome/ IE/ Edge/ Firefox). Insert “172.0.0.1”, this
IP is USM-S62 Mask address.
The figure below is the Web-GUI default interface. Insert username and
password, and click “Sign in”.
Username: root
Password:1234
3.2.2Overview
This Web-GUI will contain four parts in each subject on the left side. And
each subject has related configure options.

15
A. Status
a. Overview
b. Backhaul
B. Settings
a. Backhaul Network
b. DHCP Server
c. Configuration
d. Firmware upgrade
e. Reboot
C. LoRa
a. Data and Charts
b. Management
c. LoRa Module F/W Upgrade
d. Node Import
D. Logout

16
3.2.3Firmware Check & Update Method
3.2.3.1 USM-S62 Firmware Version Check
At first we get USM-S62 and Start Web-GUI we need to check
USM-S62 Firmware version if it is newest.
There are two methods to check the firmware, one when you start
Web-GUI and login default page. We will see “Firmware Version”.
Now is 1.0.2 (2020/9/9).
The other method is click “Status” option on the left side.

17
And click “Overview”.
3.2.3.2 USM-S62 Firmware Update Method
If the device firmware is not the newest or have some critical fix of
firmware need to update, the new firmware file will upload to
google drive and let end user download (Need Advantech related
personnel permission).
Choose Firmware Upgrade in Settings option.
And user will go to Firmware Upgrade page

18
Then we can select firmware file in the “Select File” subject.
After you choose the firmware file that provide from Advantech, it
will show file information on the page. Such as
‐File Name
‐File Size
‐File Date
Other manuals for TREK-120 Series
1
This manual suits for next models
1
Table of contents
Popular Measuring Instrument manuals by other brands

Amptek
Amptek AMETEK Mini-X2 quick start guide

Mark-10
Mark-10 TT03 Series quick start guide

Siemens
Siemens SIWAREX WL230 BB-S SA Equipment manual

Louroe Electronics
Louroe Electronics ASK-4 122 Installation and operating instructions

Dwyer Instruments
Dwyer Instruments THI2-10 Installation and operating instructions

Quarton
Quarton ML-100 instructions

THORLABS
THORLABS PM100D Operation manuals

Endress+Hauser
Endress+Hauser Teqwave T quick guide

LEYBOLD
LEYBOLD LEYSPEC view Series Hardware manual

Extech Instruments
Extech Instruments 461891 user guide

PCB Piezotronics
PCB Piezotronics 353B03 Installation and operating manual

Teledyne
Teledyne IR7000 operating instructions