manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Downeaster
  6. •
  7. Measuring Instrument
  8. •
  9. Downeaster Wind & Weather Medallion Series User manual

Downeaster Wind & Weather Medallion Series User manual

5-Year Limited Warranty
Cape Cod Wind & Weather warrants all instruments it manufactures to be free
from defects in materials and workmanship for a period of five (5) years from the
time of purchase. This warranty does not cover damages or malfunctions not
resulting from defects in material or workmanship including, but not limited to,
unauthorized repair or disassembly, modification, accident, improper installation,
lightning or other power surges, or natural disasters. Any defective instrument
returned to Cape Cod Wind & Weather during the warranty period will be repaired
or replaced at the option of Cape Cod Wind & Weather free of charge. Cape Cod
Wind & Weather does not accept liability for incidental or consequential damages,
including without limitation any liability for products not being available for use.
Cape Cod Wind & Weather disclaims all other warranties, either expressed or
implied, including, but not limited to, implied warranties of merchantability and
fitness for a particular purpose.
Please contact us before sending any item for repair;
we may be able to resolve your problem over the phone.
Phone: 877-438-2294 or 508-432-0970.
Email: [email protected]
Website: www.downeaster.com
Cape Cod Wind & Weather
189 Route 28, Unit 1
West Harwich, MA 02671
Downeaster
Wind & Weather
“For the best in weather”
Instruction Manual
Speed & Direction w/”Tru-Gust”
—Medallion Series—
Model #3035
BOX CONTENTS:
1 –Combination Wind Speed & Direction Dial
1 –Wind Speed Generator
1 –14” Straight Aluminum Mast (for Wind Speed)
1 –Cotter Pin (to secure Speed Generator to Mast)
1 –50-foot coil of 3/conductor wire (for Wind Speed)
1 –Curved Mast w/Direction Vane Assembly & 50 feet of 5/C Wire
1 –Mounting Bracket w/2 Lag Bolts and 2 U-Bolts
2 –Stainless Steel Hose Clamps (to attach masts together)
1 –6 Volt AC Power Adapter
Wind Speed & Direction with “Tru-Gust”
-Medallion Series (#3035)-
Follow these installation instructions
carefully to insure proper operation and
prevent premature failure of the
instrument. The roof-top transmitters
should be mounted on the
peak of the roof where they
will receive the greatest
exposure to the wind. Keep
away from any obstructions if possible. Be sure to install
the mast securely and vertically to prevent uneven wear.
TO INSTALL:
Do Not Plug in the instrument until ALL connections have been made.
1 –Holding the cup assembly carefully by the base, mount it on top of the
14” aluminum mast, securing it with the included cotter pin (bend one
end of the pin over to prevent it from coming out).
2 –Attach the fork terminals on the end of the speed
wire to the 3 screw terminals on the underside of the
speed generator, matching color to color.
3 –Attach the curved mast (with the Vane assembly)
to the straight mast using the two hose clamps; the
bottom of the curved
mast should be raised
about 2” above the bottom of the
straight mast.
4 –Attach the L-shaped bracket to the
roof or rake boards with the included
lag bolts. The unit can also be attached to a chimney using a masonry drill
and screw anchors.
5 –Using the U-bolts, attached the straight mast securely to the bracket.
6 –Loosen the hose clamps and rotate the curved mast until it points to
the North (the “N” inscribed on the side of Direction Vane Assembly must
face North to properly orient the unit).
7 –Run the both cables into the house to the location where the meter
will be mounted.
8 –At the back of the
meter, attach the three
Wind Speed wires to the
TOP three terminals,
matching color to color
(see diagram).
9 –Attach the five Wind
Direction wires to the
middle terminals, matching
color to color.
10 –OPTIONAL: Attach a
9V battery backup to the
two middle terminals. (The
battery backup is not
necessary, but will power the Tru-Gust for up to 48 hours in the case of a
power outage.)
11 –Attach the two wires from the power supply to the BOTTOM two
terminals on the rear of the instrument (either wire to either terminal),
then plug in the adapter.
TO OPERATE:
To see the highest wind speed since the Tru-Gust was last reset, push and
release the button on the bottom of the dial. The needle will move to the
highest reading and remain there for a few seconds before returning to
the current reading.
To RESET the gust memory, push the button in for 5 seconds and the
memory will clear. During a power outage, the wind speed will
automatically switch to the battery backup if a battery is attached.
Altering this instrument in any way will void the warranty. Please
call with any questions regarding installation or operation.
Speed Generator
(Bottom View)

This manual suits for next models

1

Other Downeaster Measuring Instrument manuals

Downeaster Wind & Weather Medallion Series User manual

Downeaster

Downeaster Wind & Weather Medallion Series User manual

Downeaster Wind & Weather Medallion Series User manual

Downeaster

Downeaster Wind & Weather Medallion Series User manual

Popular Measuring Instrument manuals by other brands

PCB Piezotronics 137BPBO PLACEBO Installation and operating manual

PCB Piezotronics

PCB Piezotronics 137BPBO PLACEBO Installation and operating manual

Hach LPV445.99.02110 user manual

Hach

Hach LPV445.99.02110 user manual

CALEFFI GE 130 Series Installation and commissioning manual

CALEFFI

CALEFFI GE 130 Series Installation and commissioning manual

HB Products HBSC2 Instruction manual supplement

HB Products

HB Products HBSC2 Instruction manual supplement

ABB CB-2000 user guide

ABB

ABB CB-2000 user guide

GAGEMAKER IT-5100 Operation manual

GAGEMAKER

GAGEMAKER IT-5100 Operation manual

CET PMC-660 Series user manual

CET

CET PMC-660 Series user manual

Vympel Hygrovision Mini operating manual

Vympel

Vympel Hygrovision Mini operating manual

CARLO GAVAZZI EM24 IS user manual

CARLO GAVAZZI

CARLO GAVAZZI EM24 IS user manual

Camlab Water CW2050 manual

Camlab

Camlab Water CW2050 manual

POWERSIDE PQube 3 installation guide

POWERSIDE

POWERSIDE PQube 3 installation guide

Elma Instruments SAGAB 981A manual

Elma Instruments

Elma Instruments SAGAB 981A manual

Circutor Getest instruction manual

Circutor

Circutor Getest instruction manual

Scaletron 1020 Oem manual

Scaletron

Scaletron 1020 Oem manual

Rion DMI108 manual

Rion

Rion DMI108 manual

GE WiMAX WX-I210+c Basic Manual

GE

GE WiMAX WX-I210+c Basic Manual

Extech Instruments 461893 user manual

Extech Instruments

Extech Instruments 461893 user manual

BEARING CHECKER SPM user guide

BEARING CHECKER

BEARING CHECKER SPM user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.