AESYS Minerva Series Operating instructions

AesysS.p.A.ViaPastrengo7c-24068Seriate-BG-Italy • T. +39 035 29240 • F. +39 035 680030 • www.aesys.com -Registeredoffice:ViaArtigiani41-24060Brusaporto-BG–Italy
Management & Coordination by Aesys Holding S.r.l. • Share Capital € 5.000.000, Fully Paid-up • VAT Number • Tax Payer’s Code • Reg. no.atTrade RegisterinBergamo02052370166
USER AND MAINTENANCE MANUAL
D
DI
IS
SP
PL
LA
AY
Y
S
SE
ER
RI
IE
ES
S
M
MI
IN
NE
ER
RV
VA
A
M
MO
ON
NO
OC
CH
HR
RO
OM
MA
AT
TI
IC
C
© AESYS S.p.A.
PRODUCT CODE
DIMENSIONAL DRAWING
---
Refer to the enclosure for this series of VMS
REL
DATE
PREPARED BY
APPROVED BY
LANGUAGE
00
08 March 2017
Ashwani Klair
English
01
26 March 2018
Ilyasse El Guelta
Simone Farina
English

Display Series Minerva Monochromatic
User and Maintenance Manual [ENG] - rel.01 (26/03/2018)
AesysS.p.A.ViaPastrengo7c-24068Seriate-BG- Italy • T. +39 035 29240 • F. +39 035 680030 • www.aesys.com -Registeredoffice: ViaArtigiani 41 -24060Brusaporto -BG –Italy
Pag.2 di 45
C
CO
ON
NT
TE
EN
NT
TS
S
1. INTRODUCTION.................................................................................................................4
1.1 Conventions used in this manual ............................................................................................... 4
1.2 Purpose of this document .......................................................................................................... 5
1.3 Manufacturer’s identifying data................................................................................................. 5
1.4 Intellectual and Industrial Property Rights................................................................................. 6
1.5 Aesys in terms of Quality and Safety.......................................................................................... 6
2. SAFETY CRITERIA ..............................................................................................................7
2.1 General instructions ................................................................................................................... 7
2.2 Suitability of operators and maintenance staff.......................................................................... 8
2.2.1 User ............................................................................................................................................. 8
2.2.2 Mechanic ..................................................................................................................................... 9
2.2.3 Electrician .................................................................................................................................... 9
2.3 Safety Regulations and Standards.............................................................................................. 9
2.4 Scrapping.................................................................................................................................. 10
3. BASIC INFORMATION ABOUT THE DISPLAYS OF SERIES MINERVA....................................11
3.1 Introduction.............................................................................................................................. 11
3.1.1 Colour of LED ............................................................................................................................. 11
3.1.2 Pixel Pitch .................................................................................................................................. 12
3.1.3 Matrix Resolution ...................................................................................................................... 12
3.1.4 Type of Container ...................................................................................................................... 13
3.1.5 Shape of Container .................................................................................................................... 13
3.1.6 Controller DC600 ....................................................................................................................... 14
3.1.7 Power Connectors...................................................................................................................... 14
3.1.8 Type of DATA Communication................................................................................................... 15
3.1.9 Connectors for DATA Communication ....................................................................................... 15
3.1.10 Cable outlet ............................................................................................................................... 16
3.2 Use............................................................................................................................................ 16
3.3 Functional Block Diagram......................................................................................................... 17
4. TECHNICAL SPECIFICATIONS ............................................................................................18
4.1 General characteristics of all models of the Series Minerva.................................................... 18
4.2 Mechanical characteristics of all models of the Series Minerva.............................................. 18
4.2.1 Housing...................................................................................................................................... 19
4.2.2 Mounting configuration ............................................................................................................ 19
4.2.3 Front Screen............................................................................................................................... 19
4.2.4 Access to the internal components............................................................................................ 19

Display Series Minerva Monochromatic
User and Maintenance Manual [ENG] - rel.01 (26/03/2018)
AesysS.p.A.ViaPastrengo7c-24068Seriate-BG- Italy • T. +39 035 29240 • F. +39 035 680030 • www.aesys.com -Registeredoffice: ViaArtigiani 41 -24060Brusaporto -BG –Italy
Pag.3 di 45
4.3 Environmental characteristics of all models of the Series Minerva......................................... 19
4.4 Electrical Characteristics of all models of the Series Minerva ................................................. 20
4.4.1 Internal Cabling ......................................................................................................................... 20
4.5 Electronic characteristics of all models of the Series Minerva ................................................ 20
4.6 Matrix characteristics of all models of the Series Minerva...................................................... 22
4.7 CE nameplate ........................................................................................................................... 22
4.8 Model MA/MW 408x512 20px................................................................................................. 23
4.9 Model MA/MW 400x500 16px................................................................................................. 24
4.10 Model MA/MW 400x400 8PX .................................................................................................. 25
4.11 Model MA/MW 350x400 24px................................................................................................. 26
4.12 Model MA/MW 375 16px......................................................................................................... 27
4.13 Model MA/MW 300x375 16px................................................................................................. 28
4.14 Model MA/MW 275x342 20px................................................................................................. 29
4.15 Model MA/MW 300x300 24px................................................................................................. 30
4.16 Model MA/MW 300x300 16px................................................................................................. 31
5. TRANSPORT, INSTALLATION AND COMMISSIONING.........................................................32
5.1 Transport and storage.............................................................................................................. 32
5.2 Installation................................................................................................................................ 32
5.3 Activation and commissioning ................................................................................................. 33
5.4 Activity log................................................................................................................................ 34
6. PREVENTIVE MAINTENANCE ...........................................................................................35
6.1 Internal and external cleaning.................................................................................................. 35
6.2 Housing of the Panel ................................................................................................................ 36
6.3 Maintenance report ................................................................................................................. 36
7. DIAGNOSTIC AND CORRECTIVE MAINTENANCE (TROUBLESHOOTING) ..........................37
7.1 Aesys Customer Service for technical assistance..................................................................... 37
7.2 Switching the sign OFF and ON again....................................................................................... 38
7.3 Replacing components ............................................................................................................. 38
7.4 Troubleshooting ....................................................................................................................... 39
7.4.1 Damages of the housing............................................................................................................ 39
7.4.2 No Message Displayed .............................................................................................................. 39
7.4.3 Partial or incorrect display of message ..................................................................................... 40
7.4.4 Other problems.......................................................................................................................... 41
7.5 Maintenance report ................................................................................................................. 42
8. MAIN COMPONENTS ......................................................................................................43
8.1 Identifyng spare parts .............................................................................................................. 43
9. WARRANTY .....................................................................................................................44
10. ENCLOSURES ...................................................................................................................45

Display Series Minerva Monochromatic
User and Maintenance Manual [ENG] - rel.00 (26/03/2018)
AesysS.p.A.ViaPastrengo7c-24068Seriate-BG- Italy • T. +39 035 29240 • F. +39 035 680030 • www.aesys.com -Registeredoffice: ViaArtigiani 41 -24060Brusaporto -BG –Italy
Pag.4 di 45
1
1.
.
I
IN
NT
TR
RO
OD
DU
UC
CT
TI
IO
ON
N
1
1.
.1
1
C
Co
on
nv
ve
en
nt
ti
io
on
ns
s
u
us
se
ed
d
i
in
n
t
th
hi
is
s
m
ma
an
nu
ua
al
l
This user and maintenance manual employs a set of conventions to facilitate its use and comprehension
and the identification of the information it provides. Here below the list:
Convention
Meaning
Aesys
AESYS S.p.A.
Manufacturer/producer
To be understood as AESYS S.p.A.
Display / Panel / VMS
To be understood as “Variable Message Sign”.
Client / purchaser / user
The owner of the Panel supplied by Aesys S.p.A.
Matrix
The front part of the panel composed of LED, where messages are
displayed.
PPE
Personal Protective Equipment.
General information.
Important information.
Important safety information: please read carefully.
Important information about electrical/electronic components: please
read carefully.
Important information about improper or hazardous conduct: please
read carefully.
Information on the disposal of industrial waste.
Chapter
1

Display Series Minerva Monochromatic
User and Maintenance Manual [ENG] - rel.00 (26/03/2018)
AesysS.p.A.ViaPastrengo7c-24068Seriate-BG- Italy • T. +39 035 29240 • F. +39 035 680030 • www.aesys.com -Registeredoffice: ViaArtigiani 41 -24060Brusaporto -BG –Italy
Pag.5 di 45
1
1.
.2
2
P
Pu
ur
rp
po
os
se
e
o
of
f
t
th
hi
is
s
d
do
oc
cu
um
me
en
nt
t
This document describes the construction, electrical hook-up, use and maintenance of displays of “Series
Minerva Monochromatic”. In detail, it includes general, legal and environmental information, handling
and installation instructions, the characteristics of the sign, safety and scheduled and occasional
maintenance instructions, information about the warranty, and the spare parts list.
A number of documents are enclosed with the manual which give specific information on the dimensions
and settings, the electronic components, and quality control reports.
Note: this user manual is provided for information only. Aesys is not liable for any
direct or indirect damage resulting from the use of this manual.
This manual is an integral part of the display, if you lose or damage it; please contact Aesys for a digital
copy (PDF) as the contact numbers are given in para 7.1.
Note: the information given in this manual is subjected to modification and updating
without notification.
Note: no part of this document may be reproduced or divulged to third parties without
written authorization from Aesys.
1
1.
.3
3
M
Ma
an
nu
uf
fa
ac
ct
tu
ur
re
er
r’
’s
s
i
id
de
en
nt
ti
if
fy
yi
in
ng
g
d
da
at
ta
a
This VMS has been designed by Aesys, which holds all rights relating to the conception, design,
technologies, industrialization and production of this panel;
Headquarters: V. Pastrengo 7/C –24068 SERIATE (BG) - ITALY
Head offices: V. Artigiani, 41 –24060 BRUSAPORTO (BG) - ITALY
Factory 1: V. Pastrengo 7/C –24068 SERIATE (BG) - ITALY
Factory 2: V. Ca’ Bertoncina – 24068 SERIATE (BG) - ITALY
Factory 3: V. Artigiani, 41 –24060 BRUSAPORTO (BG) - ITALY
Factory 4: V. San Domenico –24060 BRUSAPORTO (BG) - ITALY

Display Series Minerva Monochromatic
User and Maintenance Manual [ENG] - rel.00 (26/03/2018)
AesysS.p.A.ViaPastrengo7c-24068Seriate-BG- Italy • T. +39 035 29240 • F. +39 035 680030 • www.aesys.com -Registeredoffice: ViaArtigiani 41 -24060Brusaporto -BG –Italy
Pag.6 di 45
Aesys can be contacted as follows:
www.aesys.com
Tel + 39 035 29 240
Fax +39 035 68 00 30
These contacts are available Monday to Friday for technical assistance during the company's working hours.
Moreover, Aesys has additional offices located in several countries: for more details, please visit
www.aesys.com.
Note: for any technical assistance please contact aesys as per the reference given in
para 7.1 “Aesys ”.
1
1.
.4
4
I
In
nt
te
el
ll
le
ec
ct
tu
ua
al
l
a
an
nd
d
I
In
nd
du
us
st
tr
ri
ia
al
l
P
Pr
ro
op
pe
er
rt
ty
y
R
Ri
ig
gh
ht
ts
s
This display is the work of the intellect of Aesys who is the holder of all rights relating to conception, design,
design, technologies employed, industrialization and the production of this display. The drawings, designs,
images, trademark and prototypes of this display are and remain the exclusive property of Aesys.
Any improper or illegitimate use unauthorized by Aesys will be reported to the authorities to protect
Aesys's rights.
1
1.
.5
5
A
Ae
es
sy
ys
s
i
in
n
t
te
er
rm
ms
s
o
of
f
Q
Qu
ua
al
li
it
ty
y
a
an
nd
d
S
Sa
af
fe
et
ty
y
The company Aesys S.p.A, through its integrated management system, ensures that the entire process of
the fabrication of all its products (designing, production, testing, and handling/storage) is implemented
with maximum control in respecting the rules and regulations envisaged applicable at the product,
environment, Health & safety at work.
To ensure this, aesys has obtained the certification of ISO 9001 (Quality management System), ISO 3834-2
(Quality of welded metal assemblies), ISO 14001 (Environment) and OHSAS 18001 (Health and Safety at
work) from their respective authorities.

Display Series Minerva Monochromatic
User and Maintenance Manual [ENG] - rel.00 (26/03/2018)
AesysS.p.A.ViaPastrengo7c-24068Seriate-BG- Italy • T. +39 035 29240 • F. +39 035 680030 • www.aesys.com -Registeredoffice: ViaArtigiani 41 -24060Brusaporto -BG –Italy
Pag.7 di 45
2
2.
.
S
SA
AF
FE
ET
TY
Y
C
CR
RI
IT
TE
ER
RI
IA
A
During the designing and constructional phase of these displays, all the suitable measures and important
criteria have been adopted to satisfy the essential requisites of the following directives:
Low Voltage Directive;
Electromagnetic Compatibility Directive.
Note: Aesys is not liable for any damage or injury resulting from failure to observe the
safety instructions and recommendations given in the documentation.
Note: Aesys is not liable for any damage or injury resulting from the messages
displayed by the user on the VMS.
2
2.
.1
1
G
Ge
en
ne
er
ra
al
l
i
in
ns
st
tr
ru
uc
ct
ti
io
on
ns
s
Please read this manual carefully before installing, activating, using, servicing or working on these VMS in
any way. Do not allow inadequately trained staff to work on them.
Operators working on these VMS must use suitable PPE, such as boots, reflective jackets, helmets, eye
glasses, gloves, etc.
Caution: Aesys declares that the purchaser is responsible for the operations done on
the panel, if he fails to observe the instructions given in this manual.
Note: observing standards and using safety equipment properly enable the operator to
work in the best conditions without the risk of injury to anyone.
Chapter
2

Display Series Minerva Monochromatic
User and Maintenance Manual [ENG] - rel.00 (26/03/2018)
AesysS.p.A.ViaPastrengo7c-24068Seriate-BG- Italy • T. +39 035 29240 • F. +39 035 680030 • www.aesys.com -Registeredoffice: ViaArtigiani 41 -24060Brusaporto -BG –Italy
Pag.8 di 45
The VMS should be checked periodically for its correct functioning and presence of the safety guards. And if
not found so, it should be reported to the responsible person/supervisor immediately so that a timely
action should be taken in order to restore the proper safety guards and correct functioning of the panel.
Caution: do not remove, deactivate or tamper with any safety and protection
equipment; doing so not only voids the warranty, but Aesys in no way remains liable
for the consequences.
Caution: never work on the display while it is connected to its electrical power supply.
2
2.
.2
2
S
Su
ui
it
ta
ab
bi
il
li
it
ty
y
o
of
f
o
op
pe
er
ra
at
to
or
rs
s
a
an
nd
d
m
ma
ai
in
nt
te
en
na
an
nc
ce
e
s
st
ta
af
ff
f
The operators who are in charge of using these displays must be at least 18 years old and recognized by the
owner of the display as psychologically and physically fit to fulfill their responsibilities.
Note: the purchaser and user of the display must train his staff appointed to operate
on and servicing this panel and also about the safety equipment.
Caution: Aesys is not liable for any damage or injury resulting from use by unqualified
operators.
Aesys may agree to provide supplementary instructions to the operating staff through the supervision of its
own technical staff. Such services will be agreed upon after being defined in a separate contract.
Operators according to their responsibilities are classified as follows.
2
2.
.2
2.
.1
1
U
Us
se
er
r
Definition: a person in charge of sending the messages to VMS from a PC (Personal Computer) located
in a Remote Operations Centre:
must be instructed well to use the software connecting to the VMS by training or initial
supervision;
He is not authorized to work on electrical or mechanical equipment of the VMS.

Display Series Minerva Monochromatic
User and Maintenance Manual [ENG] - rel.00 (26/03/2018)
AesysS.p.A.ViaPastrengo7c-24068Seriate-BG- Italy • T. +39 035 29240 • F. +39 035 680030 • www.aesys.com -Registeredoffice: ViaArtigiani 41 -24060Brusaporto -BG –Italy
Pag.9 di 45
2
2.
.2
2.
.2
2
M
Me
ec
ch
ha
an
ni
ic
c
Definition: a person in charge of doing mechanical maintenance, adjustments, replacements and
repairs:
A skilled mechanic, able to service the mechanical assemblies safely and satisfactorily, due to
his theoretical knowledge and practical experience;
He is not authorized to work on electrical equipment of the VMS.
2
2.
.2
2.
.3
3
E
El
le
ec
ct
tr
ri
ic
ci
ia
an
n
Definition: a person in charge of doing electrical/electronic maintenance, adjustments, replacements
and repairs:
A skilled electrician/electronic technician, able to service the electrical and electronic systems
safely and satisfactorily, due to his theoretical knowledge and practical experience;
He is not authorized to work on mechanical equipment of the VMS.
2
2.
.3
3
S
Sa
af
fe
et
ty
y
R
Re
eg
gu
ul
la
at
ti
io
on
ns
s
a
an
nd
d
S
St
ta
an
nd
da
ar
rd
ds
s
Fully observance of the safety standards, not only enables the operator to work effectively and confidently,
but also without any risk of injury to him or to others. In addition:
make sure to shut off power (through the appropriate circuit breakers) when doing maintenance,
replacements or repairs of electrical equipment;
Make sure that the panel is installed on an adequate support that is suited to the operating
conditions and any existing risks (tampering, vibration, etc.), and verified by structural calculations
complying with the regulations in force;
Provide adequate lighting when working on the panel.
Caution: when working on the panel, do not remove its guards or safety equipment.
During normal use, the following instructions must be observed:
Always follow the procedures given for maintenance and technical assistance;
Keep a record of the dates and results of periodic inspections of the display;
Never use petrol, solvents or other flammable fluids to clean the display;
Use protective eye glasses with side guards in case of using compressed air (whether supplied in a
canister or compressor) for cleaning, and limit the pressure strictly to the necessary value;
Do not use open flames as a means of illumination;
Make sure that all live parts of the electric circuits are intact and in good working condition.

Display Series Minerva Monochromatic
User and Maintenance Manual [ENG] - rel.00 (26/03/2018)
AesysS.p.A.ViaPastrengo7c-24068Seriate-BG- Italy • T. +39 035 29240 • F. +39 035 680030 • www.aesys.com -Registeredoffice: ViaArtigiani 41 -24060Brusaporto -BG –Italy
Pag.10 di 45
Note: Aesys is not liable in any way for accidents, damage, or injury to persons or
animals resulting from any failure to observe the precautions stated, or by the removal
of safety equipment or failure to use the prescribed PPE.
2
2.
.4
4
S
Sc
cr
ra
ap
pp
pi
in
ng
g
This Aesys panel is designed according to the criteria that are in compliance with the objective of efficiency
and eco-sustainability, and its materials and/or power are largely recyclable, reusable and recoverable. It
has been fabricated in a way to have minimum industrial wastage.
The panel nonetheless contains products and substances which, upon dumping the panel in open, would
contaminate the environment. it is mainly composed of aluminum, steel, electrical cables, printed circuit
boards, tinned copper, mono-component adhesive sealant, neoprene tape, paint, batteries, and generic
electrical material.
When scrapping the panel or any part of it, to prevent environmental and health hazards due to improper
disposal, the product and its accessories should be subjected to sort waste disposal and recycling to
promote the sustainable reuse of its materials as provided by the law.
Note: always consult the local industrial waste disposal regulations in the country of
use.
In particular, during the disposal:
Avoid all damage and hazards to the health, safety and well-being of individuals and the
population;
Enforce the observance of hygiene and health regulations and avoid any risk of polluting the air,
water, ground and soil, as well as any disturbances due to noise and odors;
Safeguard the local flora and fauna and avoid damaging the environment and landscape;
Observe economic and territorial planning requirements.

Display Series Minerva Monochromatic
User and Maintenance Manual [ENG] - rel.00 (26/03/2018)
AesysS.p.A.ViaPastrengo7c-24068Seriate-BG- Italy • T. +39 035 29240 • F. +39 035 680030 • www.aesys.com -Registeredoffice: ViaArtigiani 41 -24060Brusaporto -BG –Italy
Pag.11 di 45
3
3.
.
B
BA
AS
SI
IC
C
I
IN
NF
FO
OR
RM
MA
AT
TI
IO
ON
N
A
AB
BO
OU
UT
T
T
TH
HE
E
D
DI
IS
SP
PL
LA
AY
YS
S
O
OF
F
S
SE
ER
RI
IE
ES
S
M
MI
IN
NE
ER
RV
VA
A
3
3.
.1
1
I
In
nt
tr
ro
od
du
uc
ct
ti
io
on
n
The VMS of this series are of different typology, which can be identified by their Part Number.
3
3.
.1
1.
.1
1
C
Co
ol
lo
ou
ur
r
o
of
f
L
LE
ED
D
The LED used for VMS of this series is of two colours i.e. White and Yellow amber
Chapter
3

Display Series Minerva Monochromatic
User and Maintenance Manual [ENG] - rel.00 (26/03/2018)
AesysS.p.A.ViaPastrengo7c-24068Seriate-BG- Italy • T. +39 035 29240 • F. +39 035 680030 • www.aesys.com -Registeredoffice: ViaArtigiani 41 -24060Brusaporto -BG –Italy
Pag.12 di 45
3
3.
.1
1.
.2
2
P
Pi
ix
xe
el
l
P
Pi
it
tc
ch
h
3
3.
.1
1.
.3
3
M
Ma
at
tr
ri
ix
x
R
Re
es
so
ol
lu
ut
ti
io
on
n

Display Series Minerva Monochromatic
User and Maintenance Manual [ENG] - rel.00 (26/03/2018)
AesysS.p.A.ViaPastrengo7c-24068Seriate-BG- Italy • T. +39 035 29240 • F. +39 035 680030 • www.aesys.com -Registeredoffice: ViaArtigiani 41 -24060Brusaporto -BG –Italy
Pag.13 di 45
3
3.
.1
1.
.4
4
T
Ty
yp
pe
e
o
of
f
C
Co
on
nt
ta
ai
in
ne
er
r
3
3.
.1
1.
.5
5
S
Sh
ha
ap
pe
e
o
of
f
C
Co
on
nt
ta
ai
in
ne
er
r

Display Series Minerva Monochromatic
User and Maintenance Manual [ENG] - rel.00 (26/03/2018)
AesysS.p.A.ViaPastrengo7c-24068Seriate-BG- Italy • T. +39 035 29240 • F. +39 035 680030 • www.aesys.com -Registeredoffice: ViaArtigiani 41 -24060Brusaporto -BG –Italy
Pag.14 di 45
3
3.
.1
1.
.6
6
C
Co
on
nt
tr
ro
ol
ll
le
er
r
D
DC
C6
60
00
0
3
3.
.1
1.
.7
7
P
Po
ow
we
er
r
C
Co
on
nn
ne
ec
ct
to
or
rs
s

Display Series Minerva Monochromatic
User and Maintenance Manual [ENG] - rel.00 (26/03/2018)
AesysS.p.A.ViaPastrengo7c-24068Seriate-BG- Italy • T. +39 035 29240 • F. +39 035 680030 • www.aesys.com -Registeredoffice: ViaArtigiani 41 -24060Brusaporto -BG –Italy
Pag.15 di 45
3
3.
.1
1.
.8
8
T
Ty
yp
pe
e
o
of
f
D
DA
AT
TA
A
C
Co
om
mm
mu
un
ni
ic
ca
at
ti
io
on
n
3
3.
.1
1.
.9
9
C
Co
on
nn
ne
ec
ct
to
or
rs
s
f
fo
or
r
D
DA
AT
TA
A
C
Co
om
mm
mu
un
ni
ic
ca
at
ti
io
on
n

Display Series Minerva Monochromatic
User and Maintenance Manual [ENG] - rel.00 (26/03/2018)
AesysS.p.A.ViaPastrengo7c-24068Seriate-BG- Italy • T. +39 035 29240 • F. +39 035 680030 • www.aesys.com -Registeredoffice: ViaArtigiani 41 -24060Brusaporto -BG –Italy
Pag.16 di 45
3
3.
.1
1.
.1
10
0
C
Ca
ab
bl
le
e
o
ou
ut
tl
le
et
t
3
3.
.2
2
U
Us
se
e
The VMS of series Minerva are employed in the public transportation to provide information to the
passengers in transit: Therefore they are installed in highly aggressive conditions.
It is normally driven by an on-board computer equipped with SW management, with which it
communicates via appropriate communication system.
Although these displays are designed and fabricated by using best technologies to ensure max reliability
and durability, yet above mentioned stresses for long period of time can lead to malfunctioning and failures
of the same, whose preventive and corrective maintenance procedure will be described in
chapter 6 "PREVENTIVE MAINTENANCE"; and chapter 7“DIAGNOSTIC ”.
Note: any use other than that is indicated, or any specification/protocol other than
that is described in this manual, or any installation which does not observe the
instructions provided herein, is improper: any resulting malfunctions cannot be
attributed to Aesys.

Display Series Minerva Monochromatic
User and Maintenance Manual [ENG] - rel.00 (26/03/2018)
AesysS.p.A.ViaPastrengo7c-24068Seriate-BG- Italy • T. +39 035 29240 • F. +39 035 680030 • www.aesys.com -Registeredoffice: ViaArtigiani 41 -24060Brusaporto -BG –Italy
Pag.17 di 45
3
3.
.3
3
F
Fu
un
nc
ct
ti
io
on
na
al
l
B
Bl
lo
oc
ck
k
D
Di
ia
ag
gr
ra
am
m
Display with DC600
EMBEDDED
Display standard in IBIS
Display standard in RS485
CPU BOARD 1216
RS485
DATA LINE
POWER INPUT
DC +24V
First LED Board
with photocell
N° LED Boards
CPU BOARD 1216
IBIS
DATA LINE
POWER INPUT
DC +24V
First LED Board
with photocell
IBIS Module
Board 1304
CPU BOARD 1216
DC600
POWER INPUT
DC +24V
First LED Board
with photocell
USB DATA
LINE
RS485/232
DATA LINE
N° LED Boards
N° LED Boards

Display Series Minerva Monochromatic
User and Maintenance Manual [ENG] - rel.00 (26/03/2018)
AesysS.p.A.ViaPastrengo7c-24068Seriate-BG- Italy • T. +39 035 29240 • F. +39 035 680030 • www.aesys.com -Registeredoffice: ViaArtigiani 41 -24060Brusaporto -BG –Italy
Pag.18 di 45
4
4.
.
T
TE
EC
CH
HN
NI
IC
CA
AL
L
S
SP
PE
EC
CI
IF
FI
IC
CA
AT
TI
IO
ON
NS
S
This chapter describes the mechanical, electrical and electronic characteristics of these displays. In detail, it
includes the characteristics of the matrix and related components, from the optical and the dimensional
point of view. Please read these informations carefully before using, servicing or working on these VMS.
4
4.
.1
1
G
Ge
en
ne
er
ra
al
l
c
ch
ha
ar
ra
ac
ct
te
er
ri
is
st
ti
ic
cs
s
o
of
f
a
al
ll
l
m
mo
od
de
el
ls
s
o
of
f
t
th
he
e
S
Se
er
ri
ie
es
s
M
Mi
in
ne
er
rv
va
a
General characteristics
Product :
Series Minerva monochromatic
Conformity :
UN ECE R10 –R118
SAE J1113-1
SAE J1113-11
Version :
Single sided
Installation :
On-board, ceiling installation
The VMS of series Minerva have a full type monochromatic matrix with white or amber colored LED.
The system is based upon the use of an industrial CPU that allows you to drive alphanumeric/graphics
information on to the LED matrix of VMS.
These VMS communicate via serial according to a specific protocol of data transmission.
4
4.
.2
2
M
Me
ec
ch
ha
an
ni
ic
ca
al
l
c
ch
ha
ar
ra
ac
ct
te
er
ri
is
st
ti
ic
cs
s
o
of
f
a
al
ll
l
m
mo
od
de
el
ls
s
o
of
f
t
th
he
e
S
Se
er
ri
ie
es
s
M
Mi
in
ne
er
rv
va
a
Mechanical characteristics
Case :
Aluminium, with matte black epoxy polyester paint panel.
Fixing to the support :
Through the 4 rivet nuts mounting dowels and safety bolds.
Internal access :
Open the whole rear side to access the internal components.
Chapter
4

Display Series Minerva Monochromatic
User and Maintenance Manual [ENG] - rel.00 (26/03/2018)
AesysS.p.A.ViaPastrengo7c-24068Seriate-BG- Italy • T. +39 035 29240 • F. +39 035 680030 • www.aesys.com -Registeredoffice: ViaArtigiani 41 -24060Brusaporto -BG –Italy
Pag.19 di 45
4
4.
.2
2.
.1
1
H
Ho
ou
us
si
in
ng
g
These VMS have been designed by taking into account the mode of installation, environmental conditions,
and ease of maintenance. The components have been positioned and laid out in a manner to facilitate the
maintenance process; even the unified & standard tools of minimum numbers are required for the
maintenance process.
The load-bearing structure is formed by four aluminum extruded profiles, which are fixed together to give a
certain structural strength to the container.
These displays are powder-coated with polyester polymerized paint in the range of RAL color.
4
4.
.2
2.
.2
2
M
Mo
ou
un
nt
ti
in
ng
g
c
co
on
nf
fi
ig
gu
ur
ra
at
ti
io
on
n
On both of the lateral heads of VMS, four female inserts (two on each side) are fitted to fix them onto the
supporting structure by means of four M8 bolts (see para. 5.2 “Installation”).
4
4.
.2
2.
.3
3
F
Fr
ro
on
nt
t
S
Sc
cr
re
ee
en
n
The front part of these VMS consists of masks which are made with thermoplastic material. Behind these
masks, the LED modules are mounted.
These masks are designed to prevent direct sun light onto the LED boards and also to improve the contrast
ratio of the display.
4
4.
.2
2.
.4
4
A
Ac
cc
ce
es
ss
s
t
to
o
t
th
he
e
i
in
nt
te
er
rn
na
al
l
c
co
om
mp
po
on
ne
en
nt
ts
s
The whole rear side of the VMS is closed with a back cover and self-tapping screws.
The CPU board is fixed to this back cover using M3 pin inserts, while the LED boards are mounted in front of
the display with self-tapping screws directly onto extruded profiles.
4
4.
.3
3
E
En
nv
vi
ir
ro
on
nm
me
en
nt
ta
al
l
c
ch
ha
ar
ra
ac
ct
te
er
ri
is
st
ti
ic
cs
s
o
of
f
a
al
ll
l
m
mo
od
de
el
ls
s
o
of
f
t
th
he
e
S
Se
er
ri
ie
es
s
M
Mi
in
ne
er
rv
va
a
Environmental characteristics
Degrees of protection :
IP30
Operating temperature :
-20° C ÷ +65° C
Operating humidity :
10% ÷ 90%
Cooling system :
Not present.
Heating system :
Not present.
Given the constant presence of aggressive agents such as saline mist and greasy dust, the materials used
for the container, for the screen and for the external screws were selected to be stainless (rust-resistant),
long-life (especially the polyester epoxy paint) and mechanically resistant.

Display Series Minerva Monochromatic
User and Maintenance Manual [ENG] - rel.00 (26/03/2018)
AesysS.p.A.ViaPastrengo7c-24068Seriate-BG- Italy • T. +39 035 29240 • F. +39 035 680030 • www.aesys.com -Registeredoffice: ViaArtigiani 41 -24060Brusaporto -BG –Italy
Pag.20 di 45
4
4.
.4
4
E
El
le
ec
ct
tr
ri
ic
ca
al
l
C
Ch
ha
ar
ra
ac
ct
te
er
ri
is
st
ti
ic
cs
s
o
of
f
a
al
ll
l
m
mo
od
de
el
ls
s
o
of
f
t
th
he
e
S
Se
er
ri
ie
es
s
M
Mi
in
ne
er
rv
va
a
Electrical characteristics
Input power supply
voltage :
Nominale 24VDC
Range 16 ÷ 32 VDC, Code F (referring to ISO16750-2)
Protections :
Polarity Inversion , Overload Surge / Burst suppressor
4
4.
.4
4.
.1
1
I
In
nt
te
er
rn
na
al
l
C
Ca
ab
bl
li
in
ng
g
The internal cabling of the powered components is done with conducting wires. The supply of medium-
voltage 24Vdc is done by using conducting wires of section 1.5 mm2(minimum).
For the low voltage contacts, the conducting wires of different sections running towards the various
electronic boards are used:
(LED board power)
+24 VDC (+ LED) = RED
0 VDC = BLACK of polarized connectors
For controlling the signals, the connections between CPU board and LED boards are made with flat cables
and polarized connectors.
4
4.
.5
5
E
El
le
ec
ct
tr
ro
on
ni
ic
c
c
ch
ha
ar
ra
ac
ct
te
er
ri
is
st
ti
ic
cs
s
o
of
f
a
al
ll
l
m
mo
od
de
el
ls
s
o
of
f
t
th
he
e
S
Se
er
ri
ie
es
s
M
Mi
in
ne
er
rv
va
a
Electronic characteristics
CPU :
“Type 1216 CPU board”
Total number of CPU :
1
Diagnostics :
The on-board panel controller is able to detect and transmit, via
RS485/232 or IBIS, to the host some panel anomaly, according to
the protocol.
Brightness sensor :
Front integrated in a LED board.
Data communication :
RS485/232, IBIS.
The VMS is equipped with a CPU of Aesys “Type 1216”. This CPU allows you to connect with the on-board
Computer and manages the informations to be displayed on the matrix.
This manual suits for next models
18
Table of contents