Agilent Technologies N5416A How to use

Page 1 of 9
Agilent N5416A USB 2.0 Compliance Test Software
Release Notes
Agilent N5416A Software Version 03.81
Released Date: 28 October 2013
Minimum Infiniium Oscilloscope Baseline Version: 4.20 (90000 series),
4.6(9000 series)
Minimum Infiniium Oscilloscope Baseline Version: 4.60.0005 (90000 series),
4.6(9000 series)
File Name: SetupInfUSBXP0381.exe
Modifications:
1. To upgrade framework to 0391 and support layer to 2.01
2. Fixed the problem where Upstream Low Speed test able to run at first
trial, however at second trial, the test aborts with error message "Did not find
correct waveform”.
3. For Inrush Current set the sensitivity to HIGH and the Acquisition to High
Resolution Auto mode.
4. Fixed test abort intermittently when ran Suspend / Resume Timing, to
turn off Bandwith limit to fix this issue. (This issue only affect window 7, it had
been fixed by using baseline 4.6)
5. Fixed test abort occasionally on Signal Quality Test with error message
"HSSQDevice0.tsv" was not found, especially when ran repetitive. This is due to
waveform file was not properly saved.
6. Fixed connection error where connection break when ran with 81130A.
This is due to GPIB command error. (*IDN?;*OPT?)
Agilent N5416A Software Version 03.80
Released Date: 14 June 2013
Minimum Infiniium Oscilloscope Baseline Version: 4.20 (90000 series), 4.20
(9000 series)
File Name: SetupInfUSBXP0380.exe
Modifications:
Embedded Host Test update
Remove the lost from Agilent fixture using InfiniiSim.
Agilent N5416A Software Version 03.74
Released Date: 27 May 2013
Page 2 of 9
Minimum Infiniium Oscilloscope Baseline Version: 5.71 (80000 series), 2.40
(90000 series), 2.40 (9000 series)
File Name: SetupInfUSBXP0374.exe
Modifications:
Updated USB-IF’s USBET dll to version 1.20
Upgraded framework to version 3.82
This is last version for 80000 series oscilloscope.
Agilent N5416A Software Version 03.73
Released Date: 6 April 2012
Minimum Infiniium Oscilloscope Baseline Version: 5.71 (80000 series), 2.40
(90000 series), 2.40 (9000 series)
File Name: SetupInfUSBXP0373.exe
Modifications:
Updated USB-IF’s USBET dll to version 1.13.
Fixed marker placement for EL_21 test.
Agilent N5416A Software Version 03.72
Released Date: 25 Sept 2011
Minimum Infiniium Oscilloscope Baseline Version: 5.71 (80000 series), 2.40
(90000 series), 2.40 (9000 series)
File Name: SetupInfUSBXP0372.exe
Modifications:
Upgraded framework to version 3.61 to support Windows 7 platform.
Replaced USB-IF MATLAB scripts with USB-IF’s USBET dll. Version of
the USBET dll for this release is 1.12.
Agilent N5416A Software Version 03.71
Released Date: 20 July 2011
Minimum Infiniium Oscilloscope Baseline Version: 5.71 (80000 series), 2.40
(90000 series), 2.40 (9000 series)
File Name: SetupInfUSBXP0371.exe
Modifications:
Reduced sampling rate of low speed signal quality test back to 1Gsa/s as
MATLAB script cannot handle fast sampling rate.
Fixed insufficient memory points issue for low speed signal quality test.
Agilent N5416A Software Version 03.70
Released Date: 4 Oct 2010
Page 3 of 9
Minimum Infiniium Oscilloscope Baseline Version: 5.71 (80000 series), 2.40
(90000 series), 2.40 (9000 series)
File Name: SetupInfUSBXP0370.exe
Modifications:
Upgraded framework to version 3.40 to support DSOX90000 series
oscilloscopes.
Agilent N5416A Software Version 03.60
Released Date: 10 April 2010
Minimum Infiniium Oscilloscope Baseline Version: 5.71 (80000 series), 1.41
(90000 series), 2.00 (9000 series)
File Name: SetupInfUSBXP0360.exe
Modifications:
Upgraded framework to version 3.11.
Fixed algorithm for droop drop fixture detection.
Fixed Inrush current probe impedance detection bug.
Agilent N5416A Software Version 03.51
Released Date: 25 September 2009
Minimum Infiniium Oscilloscope Baseline Version: 5.71 (80000 series), 1.41
(90000 series), 2.00 (9000 series)
File Name: SetupInfUSBXP0351.exe
Modifications:
Fixed algorithm for EL_38 and EL_40.
Agilent N5416A Software Version 03.50
Released Date: 22 June 2009
Minimum Infiniium Oscilloscope Baseline Version: 5.71 (80000 series), 1.41
(90000 series), 2.00 (9000 series)
File Name: SetupInfUSBXP0350.exe
Additions:
Supports the Infiniium 9000 series oscilloscope.
Supports latest USB-IF MATLAB script version 2.30.01.
Droop drop fixture and OTG fixture drivers are now installed automatically.
Supports single-ended measurement for Packet Parameter Tests.
Modifications:
Page 4 of 9
Outdated connection diagrams are updated.
Changed algorithm for EL 21 to ignore the first K bit in the SYNC field
since it is allowed to be distorted.
Signal quality tests do not pop-up instruction dialogs in multi-trial mode
Addressed bugs for EL 16, 17, 21, 22, 36, 37.
Changed Inrush Current Test to trigger only once then fail the test if failed
to trigger.
Corrected connection instructions for bus-powered hub Drop Test using
the new fixture.
Agilent N5416A Software Version 03.40
Released Date: 20 May 2008
Minimum Infiniium Oscilloscope Baseline Version: 5.20 (80000 series), 1.00
(90000 series)
File Name: SetupInfUSBXP0340.exe
Additions:
Supports the Hi-Speed new fixture E2649-66401, E2649-66402, E2649-
66403 and E2649-66404.
Supports the Droop/Drop tests’new fixture in automatic and manual
measurement method.
Supports the SMA connection measurement for the Hi-Speed Signal
Quality tests.
Supports the new USB-IF definitions on the Inrush current test.
Added trigger level option for the Packet Parameter Test.
Modifications:
Connection diagram of the tests related to the new fixture are updated.
Rise time and fall time measurements in the Low/Full speed tests are
informative tests.
Page 5 of 9
Agilent N5416A Software Version 03.30
Released Date: 10 Jan 2008
Minimum Infiniium Oscilloscope Baseline Version: 5.20 (80000 series), 1.00
(90000 series)
File Name: SetupInfUSBXP0330.exe
Additions:
Supports the Remote Interface Control.
Supports the Infiniium 90000 Series High Performance Oscilloscope.
Modifications:
Connection diagram for the Host Controller Packet Parameter is updated.
Non-Monotonic hysteresis is set to 30mV by default.
Page 6 of 9
Agilent N5416A Software Version 03.20
Released Date: September 2007
Minimum Infiniium Oscilloscope Baseline Version: 05.20.00
File Name: SetupInfUSBXP0320.exe
Additions
Added manual method in Signal Eye Quality tests for Hi speed, Full speed
and low speed tests.
Added sensitivity option for the EL_28 Measure Device Chirp-K Latency
Test.
Modifications:
Images for the result are shown up to the worst 25 trials.
Supports Matlab script 2.30 provided by USB-IF.
Used new specification for Rise/Fall time tests.
Page 7 of 9
Agilent N5416A Software Version 03.10
Released Date: March 2007
Minimum Infiniium Oscilloscope Baseline Version: 05.20.00
File Name: SetupInfUSBXP0310.exe
Additions
Supports Multitrial testing.
Added compliance features to allow customers to choose the hysteresis
measurement level for non-Monotonic Edge Test.
Added Noise reduction option checking system.
Modifications:
Trigger level is modified to 100mV for signal quality tests.
Only supports Matlab script 2.12.
Page 8 of 9
Agilent N5416A Software Version 03.02
Released Date: 20 Dec 2006
Minimum Infiniium Oscilloscope Baseline Version: 05.20.00
File Name: SetupInfUSBXP0302.exe
Modifications:
Matlab migration from version 7.1 to version 7.5.
Code change for triggering the last packet of signal in Host/Hub
Disconnect test.
Unit of measurement displayed at result has been corrected in Host
Packet Parameter test.
Page 9 of 9
Agilent N5416A Software Version 03.01
Released Date: 17 Oct 2006
Minimum Infiniium Oscilloscope Baseline Version: 03.90.00
File Name: SetupInfUSBXP0301.exe
Additions
OTG test supports Cypress boards (and any other manual OTG test
boards) in debug mode.
Supports MATLAB script both versions 2.10 and 2.12.
Data export tools to export test results into customer’s database
Debug features to allow customers to adjust trigger level and threshold
level for Packet Parameters test and to allow customers to adjust total
time range and trigger level for Inrush Current test.
Modifications:
Segregated test groups: Device, Hub, Host, OTG
Changed algorithm for Receiver Sensitivity test. New algorithm checks for
100% NAK.

Other Agilent Technologies Software manuals

Agilent Technologies J-BERT N4903B Technical manual

Agilent Technologies

Agilent Technologies J-BERT N4903B Technical manual

Agilent Technologies Agilent E6474A User manual

Agilent Technologies

Agilent Technologies Agilent E6474A User manual

Agilent Technologies EasyEXPERT User manual

Agilent Technologies

Agilent Technologies EasyEXPERT User manual

Agilent Technologies E6701A Operation instructions

Agilent Technologies

Agilent Technologies E6701A Operation instructions

Agilent Technologies E5071C Installation and operating manual

Agilent Technologies

Agilent Technologies E5071C Installation and operating manual

Agilent Technologies E2094S User manual

Agilent Technologies

Agilent Technologies E2094S User manual

Agilent Technologies Agilent NanoSuite 6.2 User manual

Agilent Technologies

Agilent Technologies Agilent NanoSuite 6.2 User manual

Agilent Technologies 4294A User manual

Agilent Technologies

Agilent Technologies 4294A User manual

Agilent Technologies VEE Pro User manual

Agilent Technologies

Agilent Technologies VEE Pro User manual

Popular Software manuals by other brands

Nokia 1261 - Cell Phone - AMPS user guide

Nokia

Nokia 1261 - Cell Phone - AMPS user guide

AVIRA SECURITY MANAGEMENT CENTER 2.5 - SUPPORT... manual

AVIRA

AVIRA SECURITY MANAGEMENT CENTER 2.5 - SUPPORT... manual

Toshiba Strata CIX WinCIX Technical bulletin

Toshiba

Toshiba Strata CIX WinCIX Technical bulletin

Serious Magic OVATION user guide

Serious Magic

Serious Magic OVATION user guide

Kyocera ECOSYS FS-1035MFP/DP user guide

Kyocera

Kyocera ECOSYS FS-1035MFP/DP user guide

Yamaha DME-N installation guide

Yamaha

Yamaha DME-N installation guide

Kyocera Kyocera Extended Driver user guide

Kyocera

Kyocera Kyocera Extended Driver user guide

Brother HL-5170DN Network user's guide

Brother

Brother HL-5170DN Network user's guide

Valcom V-9923B user guide

Valcom

Valcom V-9923B user guide

Adobe 65016038 - Contribute CS4 - Mac quick guide

Adobe

Adobe 65016038 - Contribute CS4 - Mac quick guide

ACRONIS TRUE IMAGE 9.1 - ENTERPRISE SERVER user guide

ACRONIS

ACRONIS TRUE IMAGE 9.1 - ENTERPRISE SERVER user guide

Adaptec AAR-2020SA reference guide

Adaptec

Adaptec AAR-2020SA reference guide

Dell PowerVault ML6000 quick start guide

Dell

Dell PowerVault ML6000 quick start guide

Symantec SERVICEDESK 7.0 MR2 - CUSTOMIZATION GUIDE... manual

Symantec

Symantec SERVICEDESK 7.0 MR2 - CUSTOMIZATION GUIDE... manual

FieldServer FS-8700-16 Driver manual

FieldServer

FieldServer FS-8700-16 Driver manual

Dell Color Laser Printer 2130cn Release notes

Dell

Dell Color Laser Printer 2130cn Release notes

Handmark WordSmith 2.2 user manual

Handmark

Handmark WordSmith 2.2 user manual

Lexicon CORE2 MAC V1.20 - RELEASE NOTES release note

Lexicon

Lexicon CORE2 MAC V1.20 - RELEASE NOTES release note

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.