AIC RSC-1R User manual

UM_RSC-1R_v1.3_020521
RSC-1R
Rackmount Chassis
User's Manual

Content
Table of Contents
Preface ������������������������������������������������������������������������������������������������ i
Safety Instructions ������������������������������������������������������������������������������ ii
About This Manual ����������������������������������������������������������������������������� iv
Chapter 1� Product Features �������������������������������������������������������������� 1
1.1 Components .............................................................................................. 1
1.2 Specifications............................................................................................ 2
1.3 Feature ....................................................................................................... 2
Chapter 2� Hardware Setup���������������������������������������������������������������� 5
2.1 Top Cover................................................................................................... 5
2.2 Power Supply Unit Module ....................................................................... 6
2.3 Fan Module ................................................................................................ 7
2.4 Disk Drive Module...................................................................................... 8
2.4.1 Disk Drive: 3.5-inch HDD...................................................................................... 8
2.4.2 Disk Drive: 2.5-inch SSD....................................................................................... 9
2.5 Slide Rail .................................................................................................. 10
Chapter 3� Hardware Specification��������������������������������������������������� 14
3.1 HDD Backplane........................................................................................ 14
3.1.1 Placement...........................................................................................................14
3.1.2 Internal Connector and Jumper ........................................................................14
3.1.3 Drive Slot Map ....................................................................................................16
Chapter 4� Technical Support����������������������������������������������������������� 17

Document Release History
Release Date Version Update Content
July, 2016 1 User's Manual release to public.
July, 2019 1.1 1. New cover
2. QIG update
August, 2020 1.2 logo update
February, 2021 1.3 Manual cover update

Copyright © 2016 AIC®, Inc� All Rights Reserved�
This document contains proprietary information about
AIC® products and is not to be disclosed or used except in
accordance with applicable agreements.

i
Copyright
No part of this publication may be reproduced, stored in a retrieval system, or
transmitted in any form or by any means, electronic, mechanical, photo-static, recording
or otherwise, without the prior written consent of the manufacturer.
Trademarks
All products and trade names used in this document are trademarks or registered
trademarks of their respective holders.
Changes
The material in this document is for information purposes only and is subject to change
without notice.
Warning
1. A shielded-type power cord is required in order to meet FCC emission limits and also
to prevent interference to the nearby radio and television reception. It is essential
that only the supplied power cord be used.
2. Use only shielded cables to connect I/O devices to this equipment.
3. You are cautioned that changes or modifications not expressly approved by the
party responsible for compliance could void your authority to operate the equipment.
Disclaimer
AIC® shall not be liable for technical or editorial errors or omissions contained herein.
The information provided is provided "as is" without warranty of any kind. To the extent
permitted by law, neither AIC® or its aliates, subcontractors or suppliers will be liable
for incidental, special or consequential damages including downtime cost; lost prots;
damages relating to the procurement of substitute products or services; or damages
for loss of data, or software restoration. The information in this document is subject to
change without notice.
Preface

Safety Instructions
Before you commence, please attentively read the following important discretions below. All
cautions and warnings on the equipment or in the manuals should be circumspectly noted
and reviewed.
Always ground yourself to prevent static electricity.Always ground yourself to prevent static electricity.
請請全程接地,以防止靜電。全程接地,以防止靜電。
请请全程接地,以防止静电。全程接地,以防止静电。
Всегда заземляйте себя, чтобы избежать статического электричества.Всегда заземляйте себя, чтобы избежать статического электричества.
Aard jezelf altijd om statische elektriciteit te voorkomen.Aard jezelf altijd om statische elektriciteit te voorkomen.
• Firmly ground yourself at all times when installing or assembling the internal
components of the server. Most of electronic components in the server are highly
sensitive to electrical static discharge.
• Use a solid grounding wrist strap and distintively place all electronic components in
static-shielded devices to prevent static. Grounding wrist straps can be purchased in
any electronic supply store.
• Confirm that the power source is turned off and then disconnect the power cords from
your system before performing any type of installation or manual servicing. A sudden
surge of power could serverly damage the sensitive electronic components.
• Do not precipitously open the system’s top cover. If you must open the cover for
maintenance purposes, only a trained technician should be allowed to proceed this
action. Integrated circuits on computer boards are highly sensitive to static electricity.
Before operating a board or integrated circuit, touch an unpainted portion of the system
unit chassis for a couple of seconds to discharge any static electricity on your body.
Place the server in a stable environment.Place the server in a stable environment.
請請將伺服器放置在穩定的環境中。將伺服器放置在穩定的環境中。
请请将伺服器放置在稳定的环境中。将伺服器放置在稳定的环境中。
Поместите сервер в стабильную среду.Поместите сервер в стабильную среду.
Plaats de server in een stabiele omgeving.Plaats de server in een stabiele omgeving.
• Place this equipment on a stable surface when installing. A small mild drop or fall could
cause fatal injury to both the equipment and the person handling the equipment.
• Please keep this equipment away from humidity to prevent vast rust and disintergration.
• Carefully and accurately mount the equipment into the rack. Uneven mechanical
loading may lead to hazadous consequences.
• This equipment is to be installed for operation in an environment with maximum
ambient temperature below 35°C.
• Review the environment before performing any installation or servicing. Keep the
equipment away from hazardous and uneven grounds.
• This server must be installed only in Restricted Acess Locations.
Handle equipment with care.Handle equipment with care.
請謹慎操作設備。請謹慎操作設備。
请谨慎操作设备。请谨慎操作设备。
Обращайтесь с оборудованием осторожно.Обращайтесь с оборудованием осторожно.
Behandel de apparatuur voorzichtig.Behandel de apparatuur voorzichtig.
• Do not cover the openings of the system. The openings on the system are for air
convection, which intentionally protect the equipment from overheating.
• Never pour any liquid into ventilation openings of the system. This could cause
catastrophic fire or electrical shock.
ii

• Ensure that the voltage of the power source is within the specification on the label
when connecting the equipment to the power outlet. The current load and output power
of loads must be within the specification.
• This equipment must be firmly connected to reliable grounding before usage. Pay
special attention to power supplied other than direct connections, e.g. using of power
strips.
• Place the power cord out of the way of foot traffic. Do not place anything over the
power cord. The power cord must be rated for the product, voltage and current marked
on the product’s electrical ratings label. The voltage and current rating of the cord
should be greater than the voltage and current rating marked on the product.
Pay attention to hardware maintenance.Pay attention to hardware maintenance.
注意硬體維護注意硬體維護。。
注意硬体维护注意硬体维护。。
Обратите внимание на обслуживание оборудования.Обратите внимание на обслуживание оборудования.
Besteed aandacht aan hardware-onderhoud.Besteed aandacht aan hardware-onderhoud.
• If the equipment is not used for a long time, disconnect the equipment from mains to
avoid being damaged by transient over-voltage.
• Module and drive bays must not be empty. They must have a dummy cover.
• Never open the equipment without professional assistence. For safety reasons, only
qualified service personnel should open the equipment.
• If one of the following situations arise, the equipment should be checked and tested by
service personnel:
1. The power cord or plug is damaged.
2. Liquid has penetrated the equipment.
3. The equipment has been exposed to moisture.
4. The equipment does not work well or will not work according to its user manual.
5. The equipment has been dropped and/or damaged.
6. The equipment has obvious signs of breakage.
7. Please disconnect this equipment from the AC outlet before cleaning. Do not
use liquid or detergent for cleaning. The use of a moisture sheet or cloth is
recommended for cleaning.
CAUTION
The equipment intended for installation should be placed in Restricted Access Location.
CAUTION
There will be a risk of explosion if battery is replaced by an incorrect type. Dispose
of used batteries according to the instructions. After performing any installation or
servicing, make sure the enclosure is correct in position before turning on the power.
CAUTION
This unit may have more than one power supply. Disconnect all power sources before
maintenance to avoid electric shock.
iii

About This Manual
Thank you for selecting and purchasing RSC-1R.
This user's manual is provided for professional technicians to perform easy hardware
setup, basic system configurations, and quick software startup. This document pellucidly
presents a brief overview of the product design, device installation, and firmware settings
for 1R Rackmount Chassis. For the latest version of this user's manual, please refer to the
AIC® website: https://www.aicipc.com/en/productdetail/83.
Chapter 1 Product Features
This chapter delivers the overall layout of the product, including the fundamental
components of the rackmount chassis, design specifications, and noteworthy features.
Chapter 2 Hardware Setup
This chapter displays an easy installation guide for assembling the chassis. Utmost
caution for proceeding to set up the hardware is highly advised.
Chapter 3 Hardware Specifications
This chapter elaborates the overall layout of the hardware design, including multifarious
connectors, jumpers, and LED descriptions.
Chapter 4 Technical Support
For more information or suggestion, please contact the nearest AIC®corporation
representative in your district or visit the AIC®website: https://www.aicipc.com/en/index.
It is our greatest honor to provide the best service for our customers.
iv

1
Chapter 1� Product Features
RSC-1R is a flexible rackmount storage chassis with tool-less design. This product
supports hot swappable HDDs and easy swap fans. For more information about our
product, please visit our website at https://www.aicipc.com/en/index.
Before removing the subsystem from the shipping carton, visually inspect the physical
condition of the shipping carton. Exterior damage to the shipping carton may indicate
that the contents of the carton are damaged. If any damage is found, do not remove
the components; contact the dealer where the subsystem was purchased for further
instructions. Before continuing, rst unpack the subsystem and verify that the number of
components in the shipping carton is accurate and in good condition.
1�1 Components
This product contains the components listed below.
Please conrm the number and the condition of the components before installation.
• Chassis (includes power supply, fan & hard disk drive tray)
• Power cord (vary per region)
• Slide rail x 1 set (optional)
Product specifications and features are subject to change without prior notice�

2
Chapter 1. Product Features
• High-density design for space saving (cost saving)
• 1 drawer to load up to 8 hot swap drives
• Tool-less design supports quick installation and easy maintenance:
- Tool-less 3.5” & 2.5” drive trays
- Tool-less top covers
• Anti-vibration rubbers on drive trays and fans
• Silicon gaskets to absorb vibration from sides of drives
• Easy swap system fans designed to minimize rotational vibration while providing
superior cooling
1�3 Feature
1�2 Specifications
Dimensions
(W x D x H)
mm : 438 x 890 x 44
inches : 17.2 x 35 x 1.7
Industry Standard EIA-RS310D
Material Heavy-duty preplated SPGC cold-rolled steel
Color Not coated
Cooling 1 x 40x28mm + 4 x 40x56mm PWM
easy swap fans
Power Supply Options
500W single PSU 80+ Platinum
600W redundant PSU 80+ Gold
Expansion Slot1full height via riser card
FrontPanel System power on/off and system reset
LEDIndicators Power, LAN and Drive
System Board 12”(W) x 13”(D) E-ATX/SSI EEB 3.6 compliant MB
Drive BaysInternal
3.5” hot swap 8
2.5” 2 (15mm)
Backplanes 2x 4-port 12Gb SAS backplanes with single
SFF-8643 connector on each
Storage
Temperature 0ºC(32ºF) ~ 50ºC(122ºF)
Humidity 5%~95% non-condensing
Gross Weight (w/ PSU & Rail)
kgs : 24.4
lbs : 53.8
Packaging
Dimensions (W x D x H)
mm : 580 x 1185 x 223
inches : 22.8 x 46.7 x 8.8
Cubic Feet 5.6
Container Load
Quantity
20’ 185
40’ 400
40’ H 440
Mounting Standard 26” tool-less slide rail

3
Chapter 1. Product Features
Front Panel
System Reset button
LAN1 Power LED
LAN2 Power LED
System HDD Activity LED
Power System LED
Power On/Off Button
Rear Panel

4
Chapter 1. Product Features
Top View
4 x40x56mm PMW easy swap fan
1 x40x28mm
PMW easy
swap fan
2.5-inch
drive tray
3.5-inch
drive tray
Full height
riser card • 500W single PSU 80+
Platinum
• 600W redumdant PSU
80+ Gold

5
Loosen the captive screw to release the top cover from the chassis.
Push the cover towards the rear panel.
Lift the cover upward to complete removal.
Chapter 2� Hardware Setup
2�1 Top Cover

6
Chapter 2. Hardware Setup
Extract the power supply unit by pushing the ejector while pulling the
power supply unit.
Pull the module completely out of the chassis.
Install the new power supply unit by pushing it into the chassis. Ensure
that the module is accurately inserted and locked into the chassis.
2�2 Power Supply Unit Module

7
Chapter 2. Hardware Setup
Unplug the cables and connectors.
Lift the fan module upward. Check to carefully dislodge the rubber connectors from
the attached bracket.
Insert the new fan into the chassis. Verify to align the rubber connectors
with the appropriate slot in the bracket.
NOTE
The fan should be blowing toward the rear end of the chassis. If one of the fans is
facing the wrong direction. Please remove the fan and reinstall so that it is facing the
correct direction.
2�3 Fan Module
rubber connector

8
Chapter 2. Hardware Setup
2�4�1 Disk Drive: 3�5-inch HDD
Remove the top cover of the chassis. Refer to Section 2.1 for removal.
Push the plunger and lift the disk drive out of the chassis.
Insert the new HDD into the chassis.
Verify that the disk drive is completely locked into the chassis.
2�4 Disk Drive Module

9
Chapter 2. Hardware Setup
2�4�2 Disk Drive: 2�5-inch SSD
Push the SSD towards the rear panel.
Continue to push and lift the SSD out of the chassis. Lift the side that is closer to
the front panel and then lift the other side for easier removal.
Insert the new SSD by aligning the SSD with the bracket holder.
Diagonally insert the SSD into the bracket. Ensure that the SSD is accurately aligned
with the rear bracket.
SSD removal
rear bracket
SSD installation
Lift this side first�Lift this side first�Lift this side first.

10
Chapter 2. Hardware Setup
NOTE
This sections provides a basic instruction for mounting the slide rail onto the system.
Tool-less rails vary per order. The rail in this manaul may not exactly match the rail for
your system. Please refer to the spefications or quick installation guide that came with
your purchased product.
Pull on the ‘’Front-Release’’to unlock the inner channel from the Slide Assembly.
Release the Detent-Lock and push Middle Channel inwards to retract Middle Channel.
2�5 Slide Rail

11
Chapter 2. Hardware Setup
Metal Spacer
Optional:
Remove Metal Spacer for Aluminium Racks
Aligning the Front Bracket with the Mounting Hole.
Push in to assembly the Front Bracket onto the Rack.

12
Chapter 3. Hardware Specifications
Now the bracket is fixed onto the Rack.
(Optional M6x10L screws are to secure the rails with posts if needed.)
Refer to Step 3 & 4 to assemble the End Bracket onto the Rack.
Table of contents
Other AIC Chassis manuals
Popular Chassis manuals by other brands

Media Links
Media Links MD8000 Series Operational manual

National Instruments
National Instruments PXI Express NI PXIe-1065 user manual

National Instruments
National Instruments cDAQ-9188XT user manual

Cisco
Cisco cBR Series manual

Cisco
Cisco Firepower 4100 Series manual

HP
HP Apollo a6000 Setup and installation guide