Aichi SD Series User manual

ConfidenceCreativityService
Single-JetDryTypeWaterMeter15mm
InstructionManual
Model
MeasurementRange
(Q3/Q1Ratio)
Description
PermanentFlowRate
1,6m3/h 100
ThankyouverymuchforpurchasingAichi
•Beforeusingthedevice,pleasereadthisinstructionmanualforcorrectuse.
•Pleasebesuretokeepthisinstructionmanualforreferenceafterreadingit.
Sensor,System&Service
SD15S
SingleJetVaneWheelTypeWaterMeter,NominalDiameter15mm,
DryDialRegister,DirectReadinginCubicMeters/Liters
swatermeterSDSeries.

-1-
TableofContents
1.FeaturesofSDSeries
2.Forsafeuse
3.Pleasekeepthefollowingsforyoursafety
4.Nameofeachpart
5.Totransportandstorethemeter
6.Whenpipingandinstalling
7.Whenoperating
8.Explanationofindication
9.Caution
………………………………
……………………………………………
……
……………………………………
…………………
…………………………
………………………………………
……………………………
……………………………………………………
2
2
3
4
4
5-6
6
7
8

•ClearDisplay
-2-
1.FeaturesofSDSeries
Meterreadingfiguresareenlargedby70%foreasierreading.
Also,theindicationmechanismisinthesealedcapsulesoastomaintainacleardisplay.
•AdjustableDisplay
Displaypartcanberotatedtoaneasytoseeposition.Itcanberotatedafterinstallation,
soitcanbemountedinanypipingdirection.
•HighQuality
Bycompletelyisolatingtheindicationmechanismfromthemeasuringwater,nowheel
damagebyforeignmatterorfreezingoccurs,whichsolvesdelayorimmobilityproblems.
2.Forsafeuse
Pleasebesuretoreadthefollowingitemsinordertousethisdry-typedirectread
watermeterSDSeriessafely.
Variouspictographsareusedinthisinstructionmanualforthepurposetoensure
yourcorrectuseoftheproduct,topreventinjurytoyouandotherpeople,andto
preventdamagetoproperty.Theindicationandmeaningofeachpictographis
explainedbelow.Pleaseunderstandthemfullypriortoreadingthetext.
Thisshowsthatanurgentdanger,includingdeathor
seriousinjury,mayoccuriftheproductishandled
improperlybyignoringthisindication.
Thisshowsthatausercandieorbeseriouslyinjured
iftheproductishandledimproperlybyignoringthe
indication.
Thisshowsthatausermaybeinjuredorphysical
damagemayoccuriftheproductishandled
improperlybyignoringtheindication.
Indication Meaning
ListedPage
Danger
Generalprohibition Disassemblyprohibited Keepawayfromflames. Besuretodo.
Warning
Caution
None
None
3
Pictographshavethefollowingmeanings.

3.Pleasekeepthefollowingsforyoursafety.
Caution
Donotdroporimpactthemeterstrongly.Doingsomayresultininjuryordamagethemeter.
(1)
(2)
(3)
(4)
(5)
(6)
(7)
Donotdropthemeter.
Yourfingersmaybecaughtorcutbytheboltthreadsifglovesarenotworn.
Alwaysweargloveswhenperforminginstallationwork.
Metermayfallcausinganinjury.
Nevergetonthemeter.
Donotinstallthemetertothepipingsystemwhereimpactpressureisapplied.Doingso
maycausewaterleakagefromthemeterandthejointarea.
Donotimpactthemeter.
Ifthemeterisimproperlyinstalled,apressurematerleakmayoccurfromtheinstallationarea.
Donotrapidlyopenorclosethewatersupplyvalve.
Ifpressureremainsinthepipe,watermayburstfromwherethemeterisinstalled.
Sufficientlyreleasepressureinthepipebeforeremovingthemeter.
Watermayleakfromthemeter.Incaseofmalfunction,pleasereplaceanewmeter.
Neverdisassemble,repair,ormodifythemeter.
-3-

4.Nameofeachpart
5.Totransportandstorethemeter
(1)
-4-
Ifthemeterisdroppedorstruck,thevanewheelbearingorgearmaybedamagedprevent
inganaccuratemeasurement.Dependingonthecase,themetermaynotfunction.
Donotimpactit.
(2)
Ifvibrationisappliedtothemeterforalong-termperiod,thevanewheelorthegearwillbe
damagedorwornout,preventingaccuratemeasurementorimpairingdurability.
Donotvibratethemeterwhileinstorage.
(3)
Thevanewheelmayrevolveduetotheair,andtheintegratedvaluemayincreaseevenifthe
meterisnotused.Keepmetercapattachedtothemeterasmuchaspossibleduringstorage.
Donotallowairtopassthroughtheinteriorofthemeterduringstorage.
(4)
Thecovermountedareamaybedamaged.Damagedcovermountedareamaycausethe
mainunittofall,resultinginaninjury.Carrythemeterbyholdingthemainbody.
Donotcarrythemeterbyholdingthecover.
2
0
1
5
G
K
0
0
0
1
N
W
S
&
D
B
SD
H
Aichitokei
SD
Q3=1,6
R100
H
Nameofmanufacturer
ModelType
PermanentFlowrate
MeasurementRangeQ3/Q1
Metermustbeinstalledinthe
horizontalposition
Marking
Cover
DigitWheel
BottomCase
Display
Indicator
Rotationindicator
(Tell-taleindicator)
,

-5-
Markingindicating
theflowdirection
Rotationdirection
270°(rotatablerange)
6.Whenpipingandinstalling
Selectaplacewherethemetercanbeinstalledhorizontally.
Installthemeteraslowaspossibleatthepiping,andselectaplacewhereairdoesnot
mixinorremaininthemeter.
Selectaplacewherewaterorsandanddirtdonotcomeincontact.Wheninstallingthe
meteroutdoor,provideapitandinstallthemeterinaplacewhererainwater,sandand
dirtdonotenter.
Selectaplacewhereinstallation,removal,meterreading,maintenance,andinspection
canbeeasilyperformed.
Aftertheinstallation,theindicatorportioncanberotatedby15degrees(270degrees
maximum)clockwisetoaneasilyreadposition.(Refertothefigurebelow.)
Selectaplacewherenovibrationsaregenerated.
Selectaplacewhichdoesnotfreeze.
(Dependingonthelocation,useaheatinsulatingcover.)
Selectaplacehavingsmallpressurefluctuations.
Selectaplacewhereambienttemperaturedoesnotexceed55°C.
Selectaplacewherenooilandpipingglueadhereorflowintoit.
(1) Selectaninstallationsitesatisfyingthefollowingcriteria.
(2) Donotinstallthemeterwhenthepipingglueisnotdry.
(3)
a.
b.
c.
d.
e.
f.
g.
h.
i.
Beforeinstallingthemeter,washthepipeinteriortoremovedirt,stones,andsand.
Rotationdirection
2
7
0
°
(
R
o
t
a
t
a
b
l
e
R
a
n
g
e
)

Markingindicatingtheflowdirection
-6-
(4) Besuretoinstallthemeterhorizontallywithoutnotilttoeithersideandalignthearrow
withtheflowdirection. (Refertothefiguresbelow.)
(5) Provideastraightpipingarea,whichismorethan3timesaslongasthediameterup -
streamfromthemeter.Provideastraightpipingarea,whoselengthisgreaterthanor
equaltothelengthofthediameterdownstreamfromthemeter.
(6) Afterinstallingthemeter,besuretograduallyopenthevalvesinfrontofandbehindthe
meteruntilthevalvesarefullyopentodischargeanyairinsidethemeter.Ifairremains,
pulsationinthepipingmayadvancethepointerevenwhennotinuse.
(7) Providepipinginawaythatpipemassdoesnotapplytothemeter.
(8) Meterinstallationsizewhenpipingisthedimensionofthepackingthicknessonboth
sidesplusthemetersentirelength.
(9) Usetheprovidedpackingorpackinghavingthespecifieddimensions.
Notethefollowingmatterswhenoperating.
7.Whenoperating
(1) Supplywatersothatthemeterisfilledandwaterflowsfreely.
(2) Checkthattheindicatorfortheminimumunitscaleortherotationindicator(tell-taleindicator)
isworking.
(3) Watertemperaturerangeis0,1°to30°C.C
(4) Refertothevaluesinthetablebelowforthemeterworkflowrate.
Correctinstallationmethod Incorrectinstallationmethod
15
0,12‒1,0
712
Diameter Model
FlowRange(m3/h) DailyAmountUsed(m3/day)
OptimumFlow
Rangefor
GeneralUse
(m
3
/h)
Accuracy±5%
Whendailytotalis
10hours
Whendailytotalis
24hours
Accuracy±2%
SD15S
0,016tobelow0,0256
0,0256‒2,0

-7-
8.Explanationofindication
(1)Asforthem3scale(chargescale),readtheindicatednumberasis.(Lscaleisindicatedin
redfigures.)
(2)The100Lorlessisusedforinspectionandtesting.
The10L、1Land0,1Lscalesareanalogtype(dialtype).Readeachpointfromthelargestdigitto
thesmallestdigitinawaysimilartoreadingtheclockhandsonthedialofaclock.
Exampleofhowtoreadtheindicatedvaluesisshownbelow.
Rotationindicator
(Tell-taleindicator)
Indicatedvalue:1234m3756,0L
2
0
1
5
G
K
0
0
0
1
N
W
S
&
D
B
SD
H

-8-
9.Caution
Themanufacturershallhavenoresponsibilityforthedamageor
failureunderthefollowingconditions:
1-2-70Chitose,Atsuta-ku,Nagoya,Japan456-8691
URL:http://www.aichitokei.co.jp/eng/
Productisdamagedduetophysicalabuse,mishandling,accident,negligenceorfailureto
followthecatalog,specificationsheet,instructionmanualfromthemanufacturer.
ProductisdamagedbyactofGodsuchasfire,earthquake,stormandflood,lightning,
vandalismorcriminalsorotherconditionsbeyondthecontrolofthemanufacturer.
Productisdamagedundercorrosiveenvironment.
Productisdamagedbytheactofdog,cat,rat,insectorothercreatures.
Productisdamagedasaresultofnotthisproductfailurebuttheotherfactors.
Producthasbeendamaged,hasbecomeunusableorhasdevelopeddefectscausedbythe
useofunauthorizedpartsorbyanunauthorizedrepairservice.
Failurewasunforeseeablebasedonthescienceortechnologyavailablewhentheproduct
wasshippedfromthemanufacturer.
Producthasbeensubjecttooperatingorphysicalconditionsoutsidethoserecommendedin
productspecificationsasprovidedbythemanufacturer.
Innoeventshallthemanufacturerbeliableforincidentalorconsequentialdamagesorany
kind,includingbutnotlimitedtolossofprofitsorrevenue,lossofuse,costofcapital,costof
substitute,equipment,facilitiesorservice,downtimecosts,delayandclaimsofpurchaser,
customerofthepurchaserorotherthirdparties.
Also,themanufacturershallnotbeliableforanylosssuchasopportunityloss,accidental
damageorallthecostsincurredduringthehandlingandshippingofrepairs,constructionor
replacementproducts.Themanufacturershallhavenoliabilityorresponsibilitywhatsoeverto
purchaseroranyotherpersonforanyloss,injury,death,oranydamagesderivedfromtheuse
oftheproductoraccessories.Inaddition,themanufacturerreservestherighttorefuse
warrantyclaimsagainstproductsorservicesthatareobtainedand/orusedincontravention
ofthelawsofanycountry.
This manual suits for next models
1
Table of contents
Popular Measuring Instrument manuals by other brands

Aethlabs
Aethlabs microAeth MA Series quick start guide

Anritsu
Anritsu MU181500B Operation manual

ICS Schneider Messtechnik
ICS Schneider Messtechnik GDM-100 operating instructions

Dell
Dell ESA 5000 Getting started guide

FroliCat
FroliCat DART duo PTY45-14259 operating guide

Circutor
Circutor DHC-96 CPM instruction manual