OSCILLATING FANS
12" (30.4 cm) MODEL 4DA35A/9102A
16" (40.6 cm) MODEL 4DA36A/9106A
SPECIFICATIONS
Motor....................................... 120V, 60Hz (12")(30.4 cm)
120V, 60Hz (16")(40.6 cm)
Blade Size............................... 12" (30.4 cm) Model(4DA35A/9102A)
16" (40.6 cm) Model(4DA36A/9106A)
Speeds.................................... 3 Speeds
Control .................................... Rotary Knob
Air Flow Distribution................ 90°
4DA35A/9102A y 4DA36A/9106A
24
23 22
21*
21*
20
27
5
4
2
29
1
3
79
28 13
9
10
12 11 15
14
8
19
25 26
18
16
6
17
FUNCIONAMIENTO
OSCILACIÓN VARIABLE: Jale la perilla de oscilación ubicada en
la parte posterior del motor hacia arriba. Gire el cabezal del
ventilador hacia la izquierda, derecha o hacia delante. Empuje la
perilladeoscilaciónhaciaabajoyelventiladoroscilarádescribiendo
el ángulo fijado.
ÁNGULO VERTICAL: Para ajustar el ángulo vertical, incline el
cabezal del ventilador hacia arriba o abajo, según prefiera.
VELOCIDAD:Lavelocidadestácontroladaporunaperillarotatoria:
(0) Apagado, (3) Alta, (2) Media, (1) Baja.
CABLEELÉCTRICO:Enchufeelcableeléctricoenuntomacorriente
de pared (CA 120 Voltios, 60 Hz).
MANTENIMIENTO
ADVERTENCIA:SIEMPREDESENCHUFEELCABLEANTES
DE MOVER O DAR SERVICIO AL VENTILADOR.
ADVERTENCIA:¡NOSUMERJAELVENTILADORENAGUA!
LIMPIEZA: Utilice un paño suave humedecido con una solución
jabonosa liviana, tal como un detergente líquido para lavar platos.
SequeTODAS LAS PARTESPOR COMPLETO antesde rearmar.
Después de dar mantenimiento o servicio, REARME POR
COMPLETO la unidad en la forma descrita en este manual de
instrucciones, antes de volver a conectarla a la fuente de poder.
PRECAUCIÓN: No utilice gasolina, bencina, acetona,
limpiadores abrasivos, etc. puesto que dañarán el Ventilador.
NUNCA use ALCOHOL O SOLVENTES.
LUBRICACIÓN: Los cojinetes de precisión vienen sellados de por
vida en la fábrica y no precisarán ninguna lubricación adicional.
ALMACENAMIENTO:GuardeelVentiladorconestasinstrucciones
en un lugar fresco y seco.
4. Para fijar la Hélice, atornille el Girador en el Eje
en el
Sentido Contrario a las Manecillas del Reloj
hasta
que se encuentre fija en el cubo de la hélice.
5. Conelcabezaldelventiladorenposiciónrecta,alineeelOrnamento
de la Parrilla Anterior para que quede en posición horizontal.
Inserte la parte inferior de la Parrilla Anterior dentro de la Parrilla
Plástica Posterior. La Lengüeta en la parte inferior de la Parrilla
Plástica Posterior debería encajar entre los rayos de la Parrilla
Anterior.EncajelaParrillaAnteriordentrodelaParrillaPlástica
Posterior comenzando desde arriba y progresando en forma
descendiente por ambos lados.
Clavija
Ranura
Figura 1 Figura 2 Figura 3
Motor
Tuerca de
Plástico
Hélice
Girador
Parrilla
Posterior
Parrilla
Posterior
Parrilla
Anterior
2084067
4
Rev.B 2/05 2084067
1
Rev. B 2/05
*NOTA: Se suministra 1 soloTapa con elVentilador.
LISTA DE REPUESTOS
NO. DE PARTE PARA EL MODELO
REF DESCRIPCIÓN
4DA35A/9102A 4DA36A/9106A
CANT.
1Motor 02030062GL 02030066GL 1
2Cubierta del motor (frontal) 2010710 2010710 1
3Cubierta del motor (trasera) 2010661 2010661 1
4Tornillo Phillips reforzado 02090040 02090040 1
# 7 x 7/16
5Botón de oscilación 2010119 2010119 1
6Interruptor 02055087 02055087 1
7Enlace de oscilación 2010276 2010276 1
8Conector de alambre 2090529 2090529 1
9Tornillo de enlace 02090140 02090140 2
10 Cuello 2010285 2010285 1
11 Perno de sujeción 02090516 02090516 1
12 Resorte de elevación — 02090586 1
13 Placa de trinquete 02010162B 02010162B 1
14 Eje de elevación 2090521 2090521 1
15 Tuerca hexagonal de 5/16-24 02090033 02090033 1
16 Base 2010540P 2010541 1
17 Perilla del Interruptor 2010131 2010131 1
18 Placa inferior 2010312 2010316 1
19 Cordón eléctrico con clavija 02050009AWFPC 02050009AWFPC 1
20 Rejilla frontal 02096217 02096214I 1
21 Tapa 2010058 2010059 1
22 Aspa 2010008 2011013 1
23 Tuerca de montaje de la rejilla 2010359 2010359 1
24 Rejilla plastica trasera 2011212 2011200M 1
25 Pata de caucho 2010415 2010415 2
26 Tornillo 2090038 2090038 1
27 Ornamento de la rejilla 02010381A 02010381A 1
28 Casquillo de cuello osc. 2010808 2010808 1
29 Tornillo #7 x.8 PPH 02090060 02090060 2
ENSAMBLADO
1. Incline el cabezal del ventilador hacia atrás. Coloque la Parrilla
Plástica Posterior en el Motor.
(Figura 1)
2. Alinee el corte triangular en “∆” en la Parrilla Plástica Posterior
conelpostetriangularenlapartesuperiordelacubiertafrontaldel
Motor. Encaje totalmente la Parrilla Plástica Posterior y fíjela
con la Tuerca de Plástico, haciéndola girar en el Sentido de las
Manecillas del Reloj.
(Figura 2)
3. Deslice la Hélice sobre el Eje del Motor. (Alinee la
Ranura en el bloque de la hélice con la Clavija del eje del
motor.)
(Figura 3)
MODEL 4DA35A/9102A 4DA36A/9106A
SPEED HIGH MED LOW HIGH MED LOW
CFM 930 780 620 1710 1500 1330
M3/s 0.43 0.37 0.29 0.80 0.71 0.63
RPM 1450 1300 1090 1545 1394 1244
Amps 0.40 0.30 0.27 0.71 0.54 0.48
Watts 39 35 32 77 65 57
dB (A) 45 41 36 53 49 44
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precau-
tions should always be followed to reduce the
risk of fire, electric shock and injury to person,
including the following:
1. Read all instructions before using Fan.
2. Make certain that the power source conforms to the electrical
requirements of the Fan.
3. Use this Fan only as described in this manual. Any other use not
recommended by the manufacturer may cause fire, electrical
shock, or injury to persons.
5. Unplug power cord before installing, servicing, or moving the Fan.
WARNING: DO NOT DEPEND UPON THE ON-OFF
SWITCH AS THE SOLE MEANS OF DISCONNECTING
POWER WHEN INSTALLING OR SERVICING THE FAN.
ALWAYS UNPLUG THE POWER CORD.
6. This Fan must NOT be used in potentially dangerous
locations such as flammable, explosive, chemical-laden
or wet atmospheres.
7. DO NOT use Fan in or near a window. Rain may create an
electrical hazard.
2. The power cord is equipped with a three-prong grounded plug
that must be inserted into a matching receptacle. Under no
circumstances must the grounding prong be cut off the plug.
Where a two-prong wall receptacle is encountered, it must be
replaced with a properly grounded three-prong receptacle in-
stalled in accordance with the National Electrical Code (NEC)
and all applicable local codes and ordinances. This work must
be done only by a qualified electrician, using copper wire only.
WARNING: USE OF A THREE-PRONG TO TWO-PRONG
ADAPTER IS NOT RECOMMENDED. IMPROPER CON-
NECTION MAY CREATE THE RISK OF ELECTROCUTION.
USEOFSUCHADAPTERSISNOTPERMITTEDINCANADA.
WARNING: THIS PLUG IS A SAFETY FEATURE. TO
REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND
PERSONAL INJURY, DO NOT REMOVE, REPLACE,
REPAIR OR TAMPER WITH THE ORIGINALLY SUPPLIED
PLUG. IFTHE FAN DOES NOT FUNCTION PROPERLY, IT
MAY BE DUE TO THE SAFETY DEVICE INCORPORATED
IN THIS PLUG. RETURN TO AN AUTHORIZED SERVICE
CENTER OR CALL 800-233-0268, MONDAY - FRIDAY,
BETWEEN 8:00 AM AND 5:00 PM EST. IF THE PLUG
WARNING LABEL IS MISSING OR DAMAGED, CALLTHE
TOLL FREE NUMBER FOR A REPLACEMENT LABEL.
8. Where possible, avoid the use of extension cords. If they must be
used, minimize the risk of overheating by ensuring that they are
ULlisted. Neverusea single extensioncord tooperate more than
one Fan.
9. Do not operate any Fan with a damaged cord or plug or after the
Fan malfunctions, has been dropped or damaged in any manner.
Return Fanto authorized servicefacilityforexamination,electrical
or mechanical adjustment or repair.
10.Do not insert or allow fingers or foreign objects to enter any
ventilation or exhaust opening as it may cause an electric shock
or fire, or damage the Fan. Do not block or tamper with the Fan
in any manner while it is in operation.
11.Always place the Fan on a stable, flat, level surface when
operating,toavoid the chanceoftheFanoverturning. Locatethe
Power Cord so the Fan or other objects are not resting on it. Do
not run Power Cord under carpeting. Do not cover Power Cord
with throw rugs, runners, or the like. Arrange Power Cord away
from room traffic and where it will not be tripped over.
12.This Fan is not intended for use in wet or damp locations.
Never locate a Fan where it may fall into a bathtub or other
water container.
13. Do not use Fan outdoors.
WARNING: REDUCETHE RISK OF FIRE OR ELECTRIC
SHOCK – DO NOT USETHIS FANWITH ANY SOLID STATE
SPEED CONTROL DEVICES.
SAVE THESE
INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT
DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO
COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
OPERATING INSTRUCTIONS & PARTS MANUAL
DESCRIPTION
TheAirKing 12"(30.4 cm)and16"(40.6cm) OscillatingFansfeature
whisper quiet operation with a 3 paddle blade. Fan is powered by a
pre-lubricatedpermanentsplitcapacitor motor with a 6ft.(1.8m)18/
3 cord set. Fan grills meet OSHA requirements. UL listed.
4DA35A/9102A and 4DA36A/9106A
ESPECIFICACIONES
Motor........................................ 120V, 60Hz (12")(30.4 cm)
................................................. 120V, 60Hz (16")(40.6 cm)
Tamaño de paletas .................... 12" (30.4 cm) Modelo (4DA35A/9102A)
................................................. 16" (40.6 cm) Modelo (4DA36A/9106A)
Velocidades ............................. 3 velocidades
Control ..................................... Perilla Rotatoria
Distribución del flujo de aire .... 90˚
OPERATION
VARIABLE OSCILLATION: Pull oscillation knob on the rear of the
motor up. Turn fan head to left, right, or straight ahead. Push
oscillation knob down and fan will oscillate about the set angle.
VERTICLE ANGLE: To adjust vertical angle, tilt fan head up or
down, as desired.
SPEED: Speed is controlled by a rotary knob. (0) Off, (3) High, (2)
Medium, (1) Low.
POWER SUPPLY CORD: Plug power supply cord into a wall outlet
(AC 120Volts, 60 Hz).
MAINTENANCE
WARNING: ALWAYS UNPLUG THE CORD BEFORE MOVING
OR SERVICING THE FAN.
WARNING: DO NOT IMMERSE FAN IN WATER!
CLEANING: Use a soft cloth moistened with a mild soap solu-
tion, such as liquid dish washing detergent. Dry ALL PARTS
COMPLETELY before reassembling. After any maintenance or
servicing,completelyreassembleunitasdescribedinthisinstruc-
tion manual before reconnecting to the power supply.
CAUTION:Donotusegasoline,benzine,thinner,harshcleaners,etc.
as they will damage the Fan. NEVER use ALCOHOL OR SOLVENTS.
LUBRICATION: Precision bearings are sealed at the factory for life
and will not require any further lubrication.
STORAGE: Store the Fan, withthese instructions, inacool, dryplace.
5. With fan head in upright position, align Ornament of Front Grill
soitishorizontal. Insert bottom ofFront Grill intoPlastic Rear Grill.
Tab atthe bottom of Plastic Rear Grill should fit betweenspokesof
FrontGrill.SnapFront Grill intoPlasticRearGrill beginningatthe
top and working down both sides.
24
23 22
21*
21*
20
27
5
4
2
29
1
3
79
28 13
9
10
12 11 15
14
8
19
25 26
18
16
6
17
VENTILADORES OSCILANTES
MODELO 4DA35A/9102A 12" (30.4 cm)
MODELO 4DA36A/9106A 16" (40.6 cm)
REF 12" (30.4cm) 16" (40.6cm)
*NOTE: Only 1 Spinner supplied with Fan.
2084067
2Rev. B 2/05 2084067
3
Rev. B 2/05
ASSEMBLY
1. Tilt Fan Head back. Put Plastic Rear Grill on Motor.
(Figure 1)
2. Align Triangular "∆" cut in Plastic Rear Grill with triangular post
on top of front Motor cover. Fully seat Plastic Rear Grill and
secure with Plastic Nut turning Clockwise.
(Figure 2)
3. Slide Blade onto Motor Shaft. (Align groove on
blade hub with pin on motor shaft.)
(Figure 3)
4. TosecureBlade,screwSpinnerontoShaft
Counter
Clockwise
until tight on blade hub.
Pin
Groove
Figure 1
Motor
Plastic Nut
Blade
Spinner
Plastic Rear
Grill
Plastic
Rear Grill
Front
Grill
Figure 2 Figure 3
REPLACEMENT PART LIST
PART NO. FOR MODEL
NO. DESCRIPTION 4DA35A/9102A 4DA36A/9106A QTY.
1Motor 02030062GL 02030066GL 1
2Motor cover (Front) 2010710 2010710 1
3Motor cover (Rear) 2010661 2010661 1
4Screw #7x7/16" 02090040 02090040 1
5Oscillation Knob 2010119 2010119 1
6 Rotary Switch 02055087 02055087 1
7Oscillation Link 2010276 2010276 1
8Wire Connector 2090529 2090529 1
9Link Screw 02090140 02090140 2
10 Neck 2010285 2010285 1
11 Shoulder Bolt 02090516 2090516 1
12 Elevation Spring — 02090586 1
13 Ratchet Plate 02010162B 02010162B 1
14 Neck Bolt 2090521 2090521 1
15 5/16-24 Hex Nut 02090033 02090033 1
16 Stand 2010540P 2010541 1
17 Switch Knob 2010131 2010131 1
18 Bottom Plate 2010312 2010316 1
19 Power Supply Cord w/ Plug 02050009AWFPC 02050009AWFPC 1
20 Front Grill 02096217 02096214I 1
21 Spinner 2010058 2010059 1
22 Fan Blade 2010008 2011013 1
23 Plastic Nut 2010359 2010359 1
24 Plastic Rear Grill 2011212 2011200M 1
25 Rubber Foot 2010415 2010415 2
26 Screw #8 X 9/16 PPH 2090038 2090038 1
27 Grill Ornament 02010381A 02010381A 1
28 Oscillating Neck Bushing 2010808 2010808 1
29 Screw #7x .8 PPH 02090060 02090060 2
MODELO 4DA35A/9102A 4DA36A/9106A
VELOCIDAD ALTA MEDIA BAJA ALTA MEDIA BAJA
CFM 930 780 620 1710 1500 1330
M3/s 0.43 0.37 0.29 0.80 0.71 0.63
RPM 1450 1300 1090 1545 1394 1244
Amps 0.40 0.30 0.27 0.71 0.54 0.48
Watts 39 35 32 77 65 57
dB A 45 41 3653 49 44
CONSERVE ESTAS
INSTRUCCIONES
INFORMACIÓN GENERAL DE SEGURIDAD
Al usar aparatos eléctricos, las precauciones
básicas de seguridad deberan siempre de seguirse
para reducir el riesgo de incendio, choque eléctrico,
y daño a personas, incluyenda las siguientes.
1. Lea todas las instrucciones antes de utilizar el Ventilador.
2. Cerciórese de que la fuente de poder sea compatible con las
demandas eléctricas del Ventilador.
3. Useeste Ventilador sólo enlaformaque se describeenelmanual.
Cualquierotrousonorecomendadoporelfabricantepodríaocasionar
un incendio, golpes de electricidad o lesiones a personas.
5. Desenchufe el cable eléctrico antes de instalar, proporcionar
servicio o mover el Ventilador.
ADVERTENCIA: NO DEPENDA DEL INTERRUPTOR DE
ENCENDIDO-APAGADO COMO EL ÚNICO MEDIO PARA
DESCONECTAR LA POTENCIA AL INSTALAR O
PROPORCIONARLE SERVICIO AL VENTILADOR.
DESENCHUFE SIEMPRE EL CABLE ELÉCTRICO.
6. EsteVentiladorNOdebeusarse en ubicaciones potencialmente
peligrosas, tales como en ambientes inflamables, explosivos,
cargados de sustancias químicas o húmedos.
7. NOuse el Ventiladoreno cerca deunaventana. La lluviapuede
generar riesgos eléctricos.
2. El cordón eléctrico está equipado con una clavija a tierra de tres
espigasque tienequeserenchufadaaunreceptáculodelmismo
diseño. Bajo ninguna circunstancia deberá cortarse la espiga a
tierra de la clavija. De existir un receptáculo de pared de dos
espigas, deberá reemplazarse por uno de tres espigas
debidamente puesto a tierra e instalado de conformidad con el
CódigoNacionalde Electricidadytodosloscódigos yordenanzas
locales aplicables. El trabajo deberá hacerlo un electricista
calificado, utilizando exclusivamente alambre de cobre.
ADVERTENCIA: NO SE RECOMIENDA EL USO DE UN
ADAPTADOR DE TRES A DOS ESPIGAS. LA CONEXIÓN
INDEBIDA PODRÍA CREAR EL RIESGO DE SER
ELECTROCUTADO. EL USO DE TALES ADAPTADORES NO
ESTÁ PERMITIDO EN CANADÁ.
ADVERTENCIA: ESTE ENCHUFE ES UNA MEDIDA DE
SEGURIDAD. PARA REDUCIR EL RIESGO DE INCENDIO,
CHOQUE ELÉCTRICOY LESIONES PERSONALES, NO QUITE, NI
REEMPLACE, NI REPARE O ALTERE EL ENCHUFE QUE SE
PROVEE ORIGINALMENTE. SI EL VENTILADOR NO FUNCIONA
CORRECTAMENTE, PUEDE DEBERSE AL DISPOSITIVO DE
SEGURIDAD INCORPORADO EN ESTE ENCHUFE. REGRESE A
UN CENTRO DE SERVICIOS AUTORIZADO O LLAME AL 800-233-
0268, DE LUNES A VIERNES ENTRE LAS 8.00 A.M. Y LAS 5.00
P.M. EST. SI LA ETIQUETA DE ADVERTENCIA DEL ENCHUFE
FALTA O ESTA DAÑADA, LLAME AL NÚMERO DE CONSULTA
GRATUITO PARA PEDIR UNA ETIQUETA DE REEMPLAZO.
8. De ser posible, evite el uso de cables de extensión. Si debieran
usarse, minimice el riesgo de sobrecalentamiento procurando
que estén aprobados por UL. Nunca use un solo cable de
extensión para hacer funcionar más de un Ventilador.
9. No haga funcionar ningún Ventilador con un cable o enchufe
dañadoodespuésdequeelventiladorpresentealgúndesperfecto
ohayasidodejadocaerosufriera cualquiertipodedaño.Regrese
elVentiladoraunserviciodereparaciónautorizadoparaexaminar
elVentilador,efectuarleajusteseléctricosomecánicosorepararlo.
10.No introduzca ni permita que se introduzcan dedos u objetos
extrañosenningunaaberturadeventilacióno escape,puestoque
podría provocar un golpe de electricidad, incendio, o daños al
ventilador. No bloquee ni manipule el Ventilador de ninguna
manera mientras esté en funcionamiento.
11.Siempre coloque el Ventilador sobre una superficie, estable,
planayhorizontalmientrasesté en funcionamiento, para evitar la
posibilidad de que el Ventilador se dé vuelta. Ubique el cable
eléctricodetalmodoqueelventiladoruotrosobjetosnodescansen
sobre él. No disponga el cable eléctrico debajo de alfombras. No
cubraelcableeléctricocontapetes,alfombrascontinuasuobjetos
similares.Coloqueelcableeléctricofueradelpasodelaspersonas
y donde nadie se tropiece con el mismo.
12.EsteVentilador nohasidodiseñadoparausarseenlugaresmojados
ohúmedos.NuncacoloqueunVentiladordondequepalaposibilidad
de que caiga en una bañera u otro recipiente con agua.
13.No use el Ventilador en exteriores.
ADVERTENCIA: DISMINUYAELRIESGODEINCENDIO O GOLPES
DE ELECTRICIDAD – NO USE ESTE VENTILADOR CON
ARTEFACTOS DE CONTROL DE VELOCIDAD EN ESTADO SÓLIDO.
LEA Y GUARDE ESTAS INSTRUCCIONES
LÉALAS CUIDADOSAMENTE ANTES DE INTENTAR ARMAR, INSTALAR, OPERAR O DAR MANTENIMIENTO AL PRODUCTO
DESCRITO. PROTÉJASE A SÍ MISMO Y A LOS DEMÁS OBSERVANDO TODA LA INFORMACIÓN SOBRE SEGURIDAD. ¡NO
SEGUIR LAS INSTRUCCIONES PODRÍA RESULTAR EN LESIONES PERSONALES Y/O DAÑOS A LA PROPIEDAD!
GUARDE LAS INSTRUCCIONES PARA REFERENCIAS FUTURAS.
MANUAL DE INSTRUCCIONES DE OPERACIÓN Y PARTES
DESCRIPCIÓN
Los Ventiladores Oscilantes AirKing®de 12” (30.4 cm) y 16” (40.6
cm) vienen equipados con un motor de funcionamiento silencioso y
una hélice de tres aspas. El ventilador es potenciado por un motor
capacitador de hendidura permanente y prelubricado con un cable
eléctrico 18/3 de 6 pies (1.8 m) de largo. Las parrillas del ventilador
cumplen con los requisitos de OSHA. Equipo aprobado por UL.

This manual suits for next models

1

Other Air King Fan manuals

Air King ASF50 User manual

Air King

Air King ASF50 User manual

Air King AKSF40WT-D User manual

Air King

Air King AKSF40WT-D User manual

Air King 4CH63D User manual

Air King

Air King 4CH63D User manual

Air King D4D User manual

Air King

Air King D4D User manual

Air King 9119 Service manual

Air King

Air King 9119 Service manual

Air King BFQF50 User manual

Air King

Air King BFQF50 User manual

Air King EXHAUST FANS AS90 User manual

Air King

Air King EXHAUST FANS AS90 User manual

Air King 4TM61C Service manual

Air King

Air King 4TM61C Service manual

Air King FRAS60 User manual

Air King

Air King FRAS60 User manual

Air King 9012 Service manual

Air King

Air King 9012 Service manual

Air King ES130D2 User manual

Air King

Air King ES130D2 User manual

Air King Builder's Choice 9848M1 User manual

Air King

Air King Builder's Choice 9848M1 User manual

Air King BFQ75 User manual

Air King

Air King BFQ75 User manual

Air King AIF10X Manual

Air King

Air King AIF10X Manual

Air King 9236C User manual

Air King

Air King 9236C User manual

Air King 9856 User manual

Air King

Air King 9856 User manual

Air King ASLC120 User manual

Air King

Air King ASLC120 User manual

Air King AK965 User manual

Air King

Air King AK965 User manual

Air King FRAS70 User manual

Air King

Air King FRAS70 User manual

Air King Fan Instructions for use

Air King

Air King Fan Instructions for use

Air King EXHAUST FANS AKF80LS User manual

Air King

Air King EXHAUST FANS AKF80LS User manual

Air King FRAK80 User manual

Air King

Air King FRAK80 User manual

Air King 9212 User manual

Air King

Air King 9212 User manual

Air King AKLCSLN User manual

Air King

Air King AKLCSLN User manual

Popular Fan manuals by other brands

Ebmpapst R3G450-AQ25-68 operating instructions

Ebmpapst

Ebmpapst R3G450-AQ25-68 operating instructions

TriStar VE-5943 instruction manual

TriStar

TriStar VE-5943 instruction manual

Ebmpapst A3G500-AN33-03 operating guide

Ebmpapst

Ebmpapst A3G500-AN33-03 operating guide

VES AX315/4-1 Installation, operation & maintenance manual

VES

VES AX315/4-1 Installation, operation & maintenance manual

Honeywell HT-216E operating instructions

Honeywell

Honeywell HT-216E operating instructions

Kambrook KFA839 Nstructions booklet

Kambrook

Kambrook KFA839 Nstructions booklet

Flexit VARIO user guide

Flexit

Flexit VARIO user guide

Exhausto BESB Split quick start guide

Exhausto

Exhausto BESB Split quick start guide

Hinkley 72" ARTISTE instruction manual

Hinkley

Hinkley 72" ARTISTE instruction manual

Space-Ray SD installation manual

Space-Ray

Space-Ray SD installation manual

Sygonix 1430244 operating instructions

Sygonix

Sygonix 1430244 operating instructions

Orbegozo BF 0140 instruction manual

Orbegozo

Orbegozo BF 0140 instruction manual

Honeywell HYF1101E4 User instructions

Honeywell

Honeywell HYF1101E4 User instructions

Fumex FF 100 Series manual

Fumex

Fumex FF 100 Series manual

ORIGO CF-1512 instruction manual

ORIGO

ORIGO CF-1512 instruction manual

Holmes HT43R owner's guide

Holmes

Holmes HT43R owner's guide

Emerson CF712AB00 owner's manual

Emerson

Emerson CF712AB00 owner's manual

REVENTON DTR Technical documentation

REVENTON

REVENTON DTR Technical documentation

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.