IMPORTANT INSTRUCTIONS -
OPERATING MANUAL
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
electric shock and injury to person, including the following:
SAVE THESE INSTRUCTIONS
1. Read all instructions before installing or using switch.
2. Use this unit only in the manner intended by the manufacturer. If you have questions,
contact the manufacturer.
CAUTION: ALL ELECTRICAL WORK MUST BE DONE IN ACCORDANCE WITH
LOCAL CODES, ORDINANCES, OR NATIONAL ELECTRICAL CODE AS APPLICABLE. FOR
SAFETY, THIS PRODUCT MUST BE INSTALLED IN A GROUNDED SWITCH BOX. IF YOU
ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE THE
SERVICES OF A QUALIFIED ELECTRICIAN.
3. Turn off power and lock out service panel before installing or wiring this product.
4. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other
hidden utilities.
5. This unit must be grounded.
WARNING: TO PREVENT SERIOUS INJURY FROM ELECTRICAL SHOCK OR
DAMAGE TO ELECTRICAL COMPONENTS - DO NOT WIRE HOT.
www.airkinglimited.com
AKS New 9-12 1 of 2
Rocker Switches
Models:
AKS2, AKS3, AKS4
INSTALLATION INSTRUCTIONS
CAUTION: INSTALLATION BY A LICENSED ELECTRICIAN IS RECOMMENDED.
INSTALLATION AND USE OF THIS EQUIPMENT SHOULD BE IN ACCORDANCE WITH
PROVISIONS OF THE NATIONAL ELECTRICAL CODE, APPLICABLE LOCAL CODES AND
PERTINENT INDUSTRY STANDARDS.
CAUTION: TURN POWER OFF AT CIRCUIT BREAKER OR FUSE PANEL.
NOTE: Each individual rocker switch on this control is rated at 15 AMPS @ 120 VAC. The total load
on this control must not exceed 20 AMPS @ 120 VAC
WARRANTY IS VOID IF MISWIRED
1. Mount the Switch Box: Install at least a 2-1/2"deep switch box for 14 gauge wire or at least
a 2-3/4"deep switch box for 12 gauge wire.
2. Attach Power Cable: Connect cables to the switch box and appliance using appropriate
connectors. Provide 6"leads inside box and appliance.
3. Connect Wiring: Remove insulation per strip gauge on control (approximately 1/2") and insert
solid copper wire only into appropriate holes - Black (hot) to Common Terminal hole. Make
sure both the switch box and the appliance are properly grounded.
4. Make electrical connections following appropriate diagram. Model AKS4 utilizes two (2) - 2
rocker switches.
5. Mount Control in Switch Box: Tuck wires into switch box and fasten the control to box using
attached screws.
6. Attach Switch Plate: Fasten the switch plate to the control using the short screws from the
parts bag.
Load 1
Load 2
COM
Black
White
Ground
Red
Black
White
Ground
COM
Black
White
Ground
Red
Black
White
Ground
Black
Load 1
Load 2
Load 3
Switch Box Appliance
Switch Box Appliance
2 - ROCKER SWITCH
3 - ROCKER SWITCH
120 VAC
Line In
120 VAC
Line In