Airbi CUBIC User manual

EN
Ultrasonic humidifier
Airbi CUBIC
Instruction manual
(version 1.0)
Page 1 of 8

EN
1 Before first use
1.1 Why humidify the air
Stay in heated rooms can be not only unpleasant, but also insanitary. One of the main reason is
low humidity. Optimal humidity is between 45% and 55%, while in many of our homes in
winter humidity drops below 20%.
What does low humidity causes Dust particles, bacteria, viruses, dust mite feces are collected
by nasal mucosa are exhaled back in normal state, but due to dry air these particles get into the
lungs and reduce natural defense. This actions overload the immune system and irritate the
mucous membranes, cough, cracked lips and it is very close to any kind of disease.
Ultrasonic humidifiers Avair are ideal for apartments, offices, everywhere where low humidity
can cause health problems for people. Ultrasound produced vapor is harmless to health. The
biggest advantage of the ultrasonic humidifiers is high performance together with low energy
consumption.
1.2 Principle of ultrasonic humidifier
Ultrasonic Humidifier use the ultrasonic high-frequency oscillator to break up water into tiny
water particles with the diameter of about 1-5µm.The ventilation system blows out this water
into the dry air where they evaporate to give the required humidity. The clearly visible smooth
and even fog can be seen out of the unit.
1.3 Security instructions
Always read the user guide instructions carefully before using the device.
Keep this User's Manual for future reference.
After unpacking, make sure that humidifier wasn't damaged during transport. If you find any
damage, contact your dealer as soon as possible. We recommend you keep the packaging for
possible future use .
Before first use check that the device parameters (electric voltage, etc.) correspond to local
conditions.
Always put the humidifier on a hard, flat horizontal surface, at least 15cm from the walls
and away from any source of heat such as burners, radiators etc. The humidifier cannot
operate on a surface that is not horizontal.
Keep the humidifier out of reach of children. Do not permit children to play with it.
Before using the humidifier, unwind the cord and check if it is not damaged. Do not use it if
the cord is damaged.
Do not plug or unplug the humidifier with wet hands.
Never disassemble the basic unit.
Never operate the humidifier with a defective plug or cord, or after a breakdown or damage
of any kind. In these cases, return the appliance to the nearest approved dealer/repairer for
verification and any necessary repairs or adjustments.
Do not use additives such as perfumes, essences, etc.
Page 2 of 8

EN
Do not shake the humidifier. This could spill water into the base unit and affect its operation.
Do not leave the humidifier in the sun for a long period.
If an unusual odour occurs during normal use, turn off the appliance, unplug it and have it
verified by qualified personnel.
Unplug the humidifier before cleaning or if removing the tank.
Never touch the water or the immersed components when the appliance is in operation.
Never turn on the humidifier when there is no water in the tank.
Never scratch the transducer.
To prevent any damage to the components, do not allow water to splash inside the base unit.
Never wash the entire unit with water; do not immerse it.
The ultrasonic humidifier should be cleaned regularly. To do this, refer to the cleaning
instructions in this manual and respect them.
Do not use the humidifier if the air in the room is already sufficiently moist (more than 50%
relative humidity). Excessive humidity gives rise to condensation on cold surfaces or walls
in the room.
Device is only for indoor use.
This device is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities or lack of experience and knowledge, unless they are
supervised or have the person responsible for their safety.
Clean and dry device according to the following guidelines before storage. Don't store
device when the water is inside. Store device on dry and cool place, out of reach of children.
2 Description
2.1 Technical specifications
Model: SPS-805T
Evaporation rate: 350 ml/hod
Water tank capacity: 5 l
Noise level: < 35 dB (A)
Power supply: 220-240 V
Frequency: 50/60 Hz
Total power: 30-110W
Dimensions: 19 x 19 x 29 cm
2.2 Functions and features
Low energy consumption, save 85-90 percent of electricity of normal steam humidifier.
Lack-water security protection.
Aromatherapy
Ionizer to benefit your health.
Ceramic filter to soften and purify the water.
Three moisture control settings.
Releases abundant anion, promotes cellular metabolism, increases vitality and appetite, purifies
Page 3 of 8

EN
blood and soothes one's nerve.
Easy to refill water into the water tank
Increase and regulate relative humidity of the room air.
Eliminate electrostatic charges.
Prevent different diseases.
Keep your appearance fit and protect your skin.
Long lifetime.
2.3 Futher information about ionization
Among the factors that significantly affect air quality include ions. Ions are atoms or molecules
that have lost or gained an electron. Ions which have lost an electron are positive ions, the ions
that are obtained electron negative ions.
The open space is regularly significantly subsidized ionized air particles. In cities and in
enclosed, poorly ventilated areas, the situation is worse. In urban flats concentration of negative
ions is very low.
Here are the concentration of negative ions in different locations.
Location Concentration of negative ions
air in a city apartment 50-100 ions/cm3
air in the street 100-500 ions/cm3
air in the forests or by the sea 1 000-5 000 ions/cm3
air close to waterfalls 10 000-50 000 ions/cm3
air after storm 10 000-50 000 ions/cm
High concentration of positive ions leads to their penetration into the lungs. Using inhalation
ions get into the blood and into the body where they can cause adverse reactions. Air ionizer is a
device that uses high voltage or electric negative charge for ionization of air molecules
(negative ions production). Ionizers help to improve mood, relieve depression and improve skin
condition. Ionizer also helps with clustering dust and other particles in the air, so we can say that
ionizers particularly also clean the air.
2.4 Humidifier's diagram
1 – output nozzle
2 – tank top cover
3 – carry handle
4 – water tank
5 – filter cartridge
6 – tank bottom cover
7 – base
8 – transducer
9 – cord & plug
10 – fan
11 – water level sensor
12 – cleaning brush
13 – buttons
14 – indication light
Page 4 of 8

EN
2.5 Buttons
1 – ionizer
2 – switch on/off
3 – preheating
2.6 How to control unit
On/Off button
You can switch on/off humidifier with this button. Press the button – humidifier will start
working with low output level (button's light is red). Press the button second time – humidifier
changes output to middle level (button's light is green). Press the button third time – humidifier
changes output to high level (button's light is blue). Press the button one more time to switch off
unit.
Aromabox
Humidifier enables the use of aromatic essences. Open the aroma box
at the side of the device, pour 5 – 10 drops of your favorite essential
oil on the pad and close the aroma box. Humidifier uses the latest
techniques based on ultrasound, so that essential oils and water
atomized into microscopically small droplets. With this technology,
you can take advantage of the positive potential of aromatherapy for their needs.
Ioni zer
The ionizer button switches the ionizer on/off. If the ionizer is on, its button on the control panel
is light on.
P reheating
Heating button activate/deactivate heating function. If heating function is active button is light
on and water is heated before the decomposition. When the heating function is on, the
consumption of el. power of the device is higher.
3 Operation instructions
Before first use, allow the device to adjust room temperature at least half an hour. The device is
recommended for use in the temperature range 5-40 °C and relative humidity less than 80%.
Remove the top water tank cover (2) and lift by carry handle (3) water tank (4) from base.
Unscrew the cover from the bottom of the tank and fill the tank with clean water (water
temperature should be under 40°C). After filling water tank close it. There is no need to tighten
the cap (6) too much as re-enabling could require more force.
Check the bottom part of the humidifier and make sure that this part is clean. Carefully place
the water tank on the base, put top cover on water tank and wait a few seconds before the water
gets into the basin. Plug the cord into the outlet and make sure that humidifer is installed on
solid and flat surface.
Page 5 of 8

EN
Switch on the humidifer with on/off button (NEVER SWITCH ON DEVICE WITHOUT
WATER IN BASIN). The indicator light (14) lights up and the machine starts working. Set
your humidifier performance as you want. You can use the function of ionizer or heating, more.
Chapter 2.6.
As soon as a very small amount of water is detected, the device will sound an alarm and then
turn off automatically. Add water to the water tank and turn the appliance back on.
4 Maintenance
In case when the water is hard which means water contains too much calcium and magnesium,
they can cause “white powder” problem and give heavy scum on the surface of water basin,
transducer and inner surface of the water tank. Scum on the surface of transducer will make the
unit work improperly.
We recommend :
1. Use cold boiled water or distilled water.
2. Clean the transducer, water tank and basin unit every week.
3. Change the water in water tank more often to keep it fresh.
4. Clean the whole unit, and make sure to keep all parts of the unit dry completely when the
unit is not in use.
How to clean the transducer:
1. Put 5-10 drops of vinegar on the surface of the transducer, wait for 2-5 minutes.
2. Brush out the scum on the surface.
3. Rinse the transducer with clean water.
4. Never use sharp and solid objects for cleaning of transducer
How to clean the basin unit:
1. Clean the water basin with soft cloth and the vinegar if there is scum in it
2. If the scum is covered on the security switch, drop the vinegar on the scum and clean it out
with the brush.
3. Rinse the water basin with clean water.
How to clean water filte r:
1. Take the filter system away from the tank cover.
2. Put the filter system into the white vinegar for about 10 minutes.
3. Take the filter system away from the white vinegar; shake for several times, clean it with
clear water.
How to replace water filter :
1. Take the filter system away from the tank cover.
Page 6 of 8

EN
2. Fix new water filter.
3. Replacement is finished.
If you don't plan to use humidifier longer time remove the water filter and let it dry thoroughly.
Then wrap it in protective packaging and keep it dry and dark place.
5 Troubleshooting
Trouble ossible reason Solution
Power lamp off, humidifier
does not work
No power supply Connect power supply,
switch on
Power lamp on, no mist
outlet with wind
No water in water tank Fill water into water tank
Abnormal smell mist New unit Take out water tank, open
cover, let it stay 12 hours in
cool position
Dirty water or long time
staying water
Cleaning water tank, fill in
clear water
Power lamp on, unit doesn’t
work, water leakage
Security switch is too slight Make the switch tight
Water tank is broken Contact authorized service
Mist fog is too small Too much scum in the water
basin
Clean transducer
Water is too dirty or water
kept too long in the tank
Clean water tank, change to
fresh clear water
Abnormal noise Resonant in water tank
when water is too less
Fill water into water tank
Unit is on an unstable
surface
Move the unit to a stable flat
surface
Mist coming out from
around nozzle
There are apertures between
the nozzle and water tank
Dip the nozzle in water for a
while and then fix it to the
socket on water tank
As fault y is not considered the following :
•If use too hard water in humidifier white coating of sediment may appear in the room. This
is not malfunction. Please use soft water.
•Gurgle of water which can be heard close to humidifier is a normal sound.
•The device operates quietly, but not completely noiseless. Noise less than 35 db is not
considered as defect.
WARNING!
Should up mentioned solutions do not work please contact the manufacturer or agent. Do
never arbitrarily disassemble, repair or restructure the apparatus.
Page 7 of 8

EN
6 Disposal of the device (environment)
At the end of the product lifecycle, you should not throw this product into the
normal household garbage but bring the product to a collection point for the
recycling of electrical and electronic equipments. The symbol on the product, user
guide and/or box indicate this. Some of the product materials can be re-used if you
bring them to a recycling point. By reusing some parts or raw materials from used
products you make an important contribution to the protection of the environment. Please
contact your local authorities in case you need more information on the collection points in
your area.
Batteries must be removed before disposing of the device.
Dispose of the batteries in an environmental manner according to your country
regulations.
This product is in compliance with the essential requirements and other relevant provisions of
Directive 89/336/EEC. The device was approved for use in EU countries, therefore, bear the
CE. All necessary documentation is available at the importer address.
Changes in technical parameters, properties, printing errors in the instruction manual reserved.
EU Importer:
Bibetus s.r.o.
Loosova 262/1
Brno 638 00
Czech republic
E-mail: [email protected]
Tel: +420-544214627
Page 8 of 8
Table of contents
Other Airbi Humidifier manuals