Airtemp B3X05F2A User manual

Installation & Operations Manual
Manual de Instalación y Funcionamiento
Manuel d'installation et d'utilisation
Room Air Conditioner
Model No., No. de Modelo, N° de modèle
Serial No., No. de Serie, N° de série
Date of Purchase, Fecha de Compra, Date d’achat
For Future Reference
Write down the model and serial numbers
The model and serial numbers can be found on the side of the
cabinet near the control panel. Use these numbers in any
correspondence or service calls concerning your air
conditioner.
Para referencia futura
Escriba el número de modelo y de serie
El número de modelo y de serie se encuentran en el costado
del gabinete cerca del panel de control. Use estos números en
toda la correspondencia o llamadas de servicio relacionadas
con su acondicionador de aire.
Pour consultation ultérieure
Inscrivez les numéros de modèle et de série
Noter ci-contre les numéros de modèle et de série (on les
trouve sur le côté de la grille décorative avant, près du tableau
de commande). Communiquer ces numéros lors de toute
correspondance ou appel au service après-vente ayant trait au
climatiseur.
ENGLISH
Important Safety Instructions .................................... 1
Installation .............................................................. 2
Operation ................................................................ 4
Maintenance ............................................................ 5
Warranty .................................................................. 6
ESPAÑOL
Instrucciones importantes de seguridad.................... 7
Instalación................................................................ 8
Funcionamiento .................................................... 10
Mantenimiento ...................................................... 11
Garantía ................................................................ 12
FRANÇAIS
Directives de sécurité importantes.......................... 13
Installation ............................................................ 14
Utilisation .............................................................. 16
Dépannage ............................................................ 17
Garantie ................................................................ 18
Room Air Conditioners for
Double-Hung Windows
Acondicionadores de aire
ambientales para ventanas
de guillotina
Climatiseur d’air individuel
pour fenêtres à guillotine
For additional questions please call
1-217-347-6459
Para mayor información por favor llame al
1-217-347-6459
o envíe correo electrónico a:
Pour d'autres questions :
1.217.347.6459

RECOMMENDED CIRCUIT
WIRE SIZES
(As installed per building code) :
PROTECTOR SIZE WIRE GAUGE
15 AMP #14 MINIMUM
1
Warning Electrical Shock Hazard
• Plug unit only into grounded electrical outlet.
• Do not use an extension cord or plug adapter with this unit.
• Do not operate unit with decorative front or filter removed.
• Failure to follow these precautions could result in electrical shock, fire or personal
injury.
• If the air conditioner has a serial plate rating of 115 volts and greater than 7.5 amps it
must have its own fuse or circuit breaker, and no other device or unit should be
operated on that fuse or circuit breaker.
• We recommend that a qualified electrician install unit in accordance with the National
Electrical Code and local codes and ordinances.
•Do not operate this air conditioner without proper time delay circuit protection (circuit
breaker or fuse). Refer to serial plate for proper power supply requirements.
• Use copper conductors of correct wire gauge and protector size only.
• Do not alter cord or plug end. Do not remove warning label on cord.
Important Grounding Requirements
•Air conditioner has a three-prong grounding plug on the power supply cord, which
must be plugged into a properly grounded three-prong wall receptacle for your
protection against possible shock hazard. For models up to and including 7.5 amperes
use a grounding type wall receptacle to match the cord plug.
Three-prong grounding plug.
DO NOT ALTER PLUG END.
Grounded three-prong wall
receptacle Additional Safety Precautions
• Do not cut, alter or remove any of the expanded polystyrene (styrofoam) inside this
air conditioner.
• Do not store or use gasoline or other flammable vapors and liquids in the vicinity of
this or any other appliance. The fumes can create a fire hazard or explosion.
• Do not introduce objects in the air discharge area. This could cause permanent
damage to your unit.
• Do not pour liquids on the air conditioner as this could cause a malfunction. With the
unit unplugged, use a damp cloth for cleaning your unit.
• Avoid using strong solvents to clean the air conditioner.
• Clean the air conditioner filter every two weeks to avoid overheating caused by air
obstruction.
Do not operate without filter.
• Do not obstruct the air intake area of your air conditioner, as this could cause
overheating, thus activating the units security switch and shutting off the unit.
• Do not block air circulation to outside louvers of cabinet.
• Do not block air flow inside with blinds, curtains, or furniture, or outside with shrubs,
enclosures, or other buildings.
• Do not run the air conditioner with an outside protective cover in place. This could
result in fire or mechanical damage within the air conditioner.
A
A
B
B
125V
15A
ELECTRICAL REQUIREMENTS
& SAFETY PRECAUTIONS
INSTALLATION

2
WINDOW INSTALLATON
INSTALLATION
Tools Needed
Screwdrivers
Tape Measure
Carpenter’s Level
5/8” wood screws ....................9
Brackets....................................2
BC
A
B
Installation Parts Kit
Window Requirements
Air conditioner is factory prepared for installation in standard
double hung windows (air conditioner cannot be installed in other
types of windows). The air conditioner can be installed in
windows 23” to 34” wide when filler panels are used. In windows
19” to 22” wide the air conditioner can be installed without the
filler panels. All windows must open at least 12 3/4” vertically.
Install the air conditioner in a window where there will be enough
clearance around the cabinet to allow ample circulation of air
through unit. All supporting parts should be secured to firm wood,
masonry, or metal.
Filler Panel Installation
1. Place tabbed side of curtain in track on side of air conditioner
cabinet, and slide down the track until the curtain is even top
and bottom (Fig.1).
2. Slide the filler panel frame onto the air conditioner cabinet using
the tracks on the top and bottom of the unit. Slide the frame as
close to the air conditioner as possible so that the curtain locks
into place. Gently pull the frame out until it is the correct length
for your application.
Installation in window 23” to 34” wide
1. Open and mark center line of window. Measure and mark 6” to
the right of the center line and 6” to the left of the center line
(Fig. 2).
2. Place bracket so that the inside edge rests on the appropriate 6”
mark. Secure brackets with two (2) 1” long wood screws (Fig. 2).
1Tabbed side
of curtain
Curtain
track
Filler panel frame
Curtain
Filler panel
frame track (top)
Filler panel
frame track
(bottom)
6"
6"
Center
of window
opening
5/8” Screws
Bracket
Bracket
Window Sill
5/8” Screws
2

3
WINDOW INSTALLATON
INSTALLATION
3. To overcome storm window interference, securely attach 2” wide
wood strips to the window stool and sill, with either nails or
screws. Strips should be as long as window opening and flush
with back side of stool. Thickness of strips should be controlled
by amount of interference (Fig. 3).
4. Keeping a firm grip on air conditioner, carefully center air
conditioner in window opening with the bottom bar between the
window stool and the angle bracket. Air conditioner should slant
slightly downward on the outside as shown by half a bubble off
on a carpenters level. This outward pitch prevents water from
entering the room (Fig. 3).
5. Close the window until it touches behind air conditioner top bar.
Slide filler panels outward until they touch window sash tracks.
(Do not release grip on air conditioner until lower window sash
is in final position) (Fig. 3).
6. Secure top of filler panels by driving 5/8” long wood screws into
window sash through mounting holes in top slides.
7. Secure bottom of filler panels by driving 5/8” long screws into
window sill through filler panel tabs.
8. Cut foam seal to width of window and install between upper and
lower window sash (Fig. 4).
Bracket
Upper
Window Sash
Wood Strips
(optional)
Lower
Window Sash
Level
3
Foam Seal
Lower
Window Sash
5/8” Wood Screws
Wood Sill
Filler Panel Tab
Caution: Do not drill a hole in bottom pan. Unit is designed to
operate with approximately 1/2” of water in bottom pan.
4
Nails / Screws
L-Bracket
Installation in window 19” to 22” wide
(Do not attach filler panels for this application)
1. Refer to steps 1 and 2 of preceding instructions.
2. Close window until it touches behind top bar (Fig. 4).
3. Fasten lower window sash to window frame using finishing nails,
wood screws, or “L” brackets (Fig. 5).
4. If filler is required on sides of air conditioner, cut foam seal to size
and fill both sides.
5. Cut foam seal to width of window and install between upper and
lower window sash (Fig. 4).
5

4
OPERATION
ELECTRONIC CONTROLS
ELECTRONIC CONTROL PANEL
Power Control
The Power Control turns the unit on and off.
The Temperature/Hour Display
Shows the set temperature or the timer setting. THE TEMPERATURE DISPLAY ONLY SHOWS THE
SET TEMPERATURE, NOT THE ACTUAL ROOM TEMPERATURE.
Temperature/Hour Controls
These buttons are used to raise or lower the set temperature in increments of 1° from 66° to 88°.
They also raise or lower the hour setting in increments of 1 from 00 to 24 when the timer is being
set. In order to toggle between °F or °C, depress both of the controls at the same time.
Mode Control
The Mode Control has two settings: FAN and COOL.
The settings are adjusted with the Mode Control button. A green light indicates which setting is
currently being used. When the COOL mode is selected, the unit will circulate and cool the air.
If the FAN mode is selected, the unit will only circulate the air.
Fan Speed Control
The Fan Speed Control has three
settings: High, Low and Auto. The settings are adjusted with the Fan Speed button, each time
the button is depressed it changes the
setting. A green light will indicate which setting is currently being used.
When the Auto feature is selected while the air conditioner is in the COOL mode, the fan speeds
will change automatically as the temperature in the room changes.
• 4° or more above the set temperature the unit will be in HI FAN mode.
• 4° or less above the set temperature the unit will be in LO FAN mode.
Timer Control
The timer can be set to either turn the unit on or off.
To turn the unit on using the Timer:
•Depress the timer key when the power is off, the display will read 00. Adjust to the desired
number of hours before TURN ON using the up/down arrows.
•The display will show the time by hours left until TURN ON.
•To Turn the timer off, depress the timer key.
•A green light next to the Timer Control indicates that the timer is set.
To turn the unit OFF using the Timer:
•Depress the timer key when the power is on, the display will read 00. Adjust to the desired number of hours
before TURN OFF using the up/down arrows. The display will automatically go back to the set temperature
after 10 seconds.
•To display the amount of time left until TURN OFF, depress the timer button once.
•To turn the TIMER OFF, depress the timer button twice.
•A green light next to the Timer Control indicates that the timer is set.
C
D
E
F
Power Control
Temperature/Timer Display
Temperature/Timer Controls
Mode Control
Fan Speed Control
Timer On/Off
A
B
C
D
E
F
A
B
C
D
E
F
A
B
Built-in three minute timing delay.
This electronic controlled unit will not
automatically resume operation after a
power failure.
If this electronic unit will not respond to
touch pad or remote control commands,
it is necessary to unplug the unit from the
electrical outlet for five seconds and then
plug the unit back in.
The functions work the same as your air conditioner’s touch controls.
Air Conditioner Remote Control
AAA IEC R031.5V
+-
AAA IEC R03
1.5V
6
7
CAUTION:
• Use only AAA or IEC R03 1.5V batteries.
• Remove the batteries if the remote controller is not used for a
month or longer.
• Do not attempt to recharge the supplied batteries
• All batteries should be replaced at the same time.
• Do not dispose of the batteries in a fire as they may explode.
• Do not mix old and new batteries.
• Do not install the batteries with the polarity (+/–) reversed.
• Do not mix alkaline, standard (carbon - zinc), or rechargeable
(nickel-cadmium) batteries.
• Keep batteries and other things that could be swallowed away
from young children. Contact a doctor immediately if an
object is swallowed.
This manual suits for next models
4
Table of contents
Languages:
Other Airtemp Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic
Panasonic CS-S18HKQ Service manual

Panasonic
Panasonic CS-E15NKE3 operating instructions

Gree
Gree GWH18TC-K3DNA1B/I Service manual

Friedrich
Friedrich ZoneAire Compact P08SA owner's manual

Daikin
Daikin R32 Split Series installation manual