CAUTIONS:
Your monitor and nozzle should be inspected prior to and after each use to ensure it is in good
operating condition. Potentially, an unanticipated incident may occur where the unit is used in a manner that is inconsistent with
standard operating practices. A partial list of potential misuses includes:
Also, there are many “tell tale” signs that indicate repair is in order, such as:
technician before placing it back in service.
PACKAGING:
Each Elevated Manual Monitor is shipped unassembled. There is one long wood crate containing the Flanged Waterway and the Rota-
tion Drive Tube and a cardboard carton containing the Monitor, Nozzle, Handle Assembly, Cables and a Hardware Package.
FIELD ASSEMBLY:
Step 1 - Remove all items from the wooden crate and cardboard carton.
Step 2 – Ensure that the Rotation Drive Tube (Item 1) is installed over the Flanged Waterway (Item 2) as it was originally shipped
in the wooden crate.
Step 3 – Attach the Monitor Assembly (Item 3) to the Flanged Waterway (Item 2) via the 3” NPT connection. Use a suitable pipe
sealing compound on this connection.
Step 4
(Item 5) located in the Hardware Kit.
Note: Align the Handle Bracket located near the bottom of the Rotational Drive Tube (Item 1) with the outlet of the
Monitor Assembly (Item 3) as shown on the assembly drawing before installing these cap screws.
Step 53/8Cap Screws (Item 7) use a thread
locking compound such as Loctite 222 or Permabond LM113 on these cap screws.
Step 6 – Attach the Elevation Control Cables (Item 9) to the Elevation Control Arm (Item 10) located on the side of the Monitor
Assembly (Item 3) using the “D” Rings (Item 11) located in the Hardware Kit as shown on the assembly drawing.
Step 7 – Attach the Turnbuckles (Item 12) to the Handle Assembly (Item 6) using the (2) Cap Screws (Item 13) and Spacers
Step 8 – Attach the other ends of the Elevation Control Cables (Item 9) to the Turnbuckles as shown on the assembly drawing.
Step 9 – Adjust the Turnbuckles (Item 12) so that the Handle Assembly (Item 6) and outlet of the monitor (Item 3) are parallel.
Step 10 – Attach either the Nozzle (Item 15) or Tip and Discharge Tube (Item 15) - which ever was purchased with the Manual
Elevated Monitor - to the Monitor Assembly (Item 3) via the 2 ½ “ NH connection. If a Tip and Discharge Tube was