alberta BP1 User manual

Solid Black
White Stripe
24V AC
Terminal
DEALER INSTALLATION AND
OPERATING INSTRUCTION
24 VOLT POWER ONLY AC or DC
NOMINAL VOLTAGE REQUIRED: 24 Volts
FIGURE #1
POWER CONSUMPTION: 2 Watts
CURRENT DRAW: 64 MilliAmps at 24 Volts
VOLTAGE RANGE: 22 Volts to 32 Volts
NOTE: THE LED POWERHEAD INDICATOR LIGHT MUST BE ON FOR EFFECTIVE OPERATION
THE BP1 ELECTRONIC AIR CLEANER REQUIRES CONNECTION TO A 24 VOLT POWER
SOURCE. DO NOT CONNECT THE POWER SUPPLY CORD TO 110 VOLTS. IN SOME NEWER
SYSTEMS THE HUMIDIFIER TERMINAL MAY BE 24 VOLTS. THIS IS SUITABLE FOR
CONNECTION. BE SURE TO CHECK WITH A VOLTMETER.
The BP1 electronic air cleaner retro-fits into any one inch filter opening. Remove the existing one inch air
filter and replace it with the BP1 electronic air cleaner. Next, connect the power cord supplied to a low voltage
power supply. In most cases you will have a variety of choices. Some of the newer systems have a 24 volt
terminal for humidifiers and other low voltage system accessories.
The BP1 air cleaner can be powered from this source. Be sure to identify that the terminal is 24 volts. A
second common option is to locate the low voltage 24 volt transformer within the system. This transformer is
ideal and can be easily used to power the this electronic air cleaner. The BP1 draws a very small amount of
current and will not overload the system. The air cleaner can be connected permanently to the 24 volt side of
the transformer without any need for switching. The BP1 air cleaner requires less than two watts of power to
operate.
Note: using an AC volt meter be sure to identify the correct terminals. The terminal voltage needs to read
between 24 and 30 volts ac. Also identify which terminal, if any, is connected to the equipments frame. This
can be done by connecting one of the leads of the meter to the equipments frame and the other lead to either
terminal. The grounded terminal will not have a voltage on it. Connect the BP1 power cord as shown in figure
#1.
The side of the power cord that has a white stripe on it is connected to the grounded terminal. Once you have
connected the power cord to the 24 volt power source insert the power cord plug into the BP1 electronic
powerhead. At this point the small led light on the powerhead will turn on indicating full power. If the small
led light is not on then the BP1 air cleaner will not operate properly. Re-check your voltage to be sure the air
cleaner is receiving power.
The BP1 electronic air cleaner has been designed to operate with constant power or in series with the
systems fan. Both methods will permit reliable, long term, performance.

The BP1 electronic air cleaner may snap or arc electrically upon initial installation. This is due to a build-up of
h
umidity within the air cleaner. This condition will subside after several hours of operation. The BP
1
e
lectronic air cleaner has been engineered to operate quietly. There may be an occasional snap or arc. This i
s
normal and will not interfere with the effective operation of the air cleaner.
In order to ensure effective performance for the BP1 electronic air cleaner periodic replacement of the special
media pads inside is required. The original BP1 media pads are a unique, multi-layered, proprietary material.
The BP1 replacement media pads are available in a convenient one or two year pack.
The BP1 electronic air cleaner will not operate properly if alternative materials are used. It is Recommended
that the pads be replaced every three to four months.
To replace the media pads disconnect the power cord at the top of the air cleaner and remove the electronic
air cleaner from the filter rack. Pull the latches up on the side of the air cleaner. Open the air cleaner on a flat
surface and discard the two dirty media pads. Then take two new media pads from the original BP1 media
pack and install them. Close the air cleaner, re-seat the latches and re-install. Be sure to reconnect the power
cord.
The limited warranty covers any defect in materials or workmanship for a period of five years. The warranty
p
eriod commences on the purchase date of the product. The warranty does not cover any damage fro
m
m
isuse, neglect or abuse. To make a warranty claim contact the original installing contractor or Albert
a
I
ndoor Clean Air directly with a copy of an original sales receipt or other evidence of the date of purchase.
MAINTENANCE
FOR CUSTOMER SERVICE CONTACT US AT:
1-(888) 634-8288 • (403) 230-2431
WARRANTY
3SBP1-instr
www.albertacleanair.ca
Physician’s Name: ____________________________________________________________________________________________
Physician’s Authorization: _______________________________________________________________________________________
______
Prescription: _________________________________________________________________________________________________________
Patient Name: ____________________________________________________________________________
____________________________
Address: ____________________________________________________________________________________________________________
City: ________________________________ State/Province: __________________
______ Zip /Postal Code: _________________________
Note: In some areas air cleaners are covered by medical insurance and may also be tax deductible if prescribed by a
Physician. This will vary according to local legislation. The following information is normally required.
Table of contents
Popular Air Cleaner manuals by other brands

Aerial
Aerial AMH 100 operating instructions

Lasko
Lasko HF11200 Use and care guide

Bionaire
Bionaire BAP1502WO-CN instruction manual

KRUG+PRIESTER
KRUG+PRIESTER Ideal Luft AP30 Pro operating instructions

IconBiT
IconBiT U LIGHT COMBO TRS2075 user manual

AAF
AAF Flanders AstroPure 500-IR Installation, operation and maintenance manual