Alfalaval TE67O User manual

TE91K023-EN5
ESE01748EN
Date of issue: October 2019
First published: 2010
Instruction Manual
Alfa Laval Level Switch (TE67O)

Page 2 Instruction Manual, Alfa Laval Level Switch
TE91K023-EN5
Table of contents
1. EC Declaration of conformity...........................................................................................3
2. Safety..................................................................................................................................4
2.1. Important information ................................................................................................................. 4
2.2. Warning signs............................................................................................................................. 4
2.3. Safety instructions ...................................................................................................................... 5
3. General description...........................................................................................................6
3.1. Working principle of the level switch........................................................................................... 6
3.2. General description .................................................................................................................... 6
3.3. Recycling information ................................................................................................................. 6
4. Technical specifications ..................................................................................................7
4.1. Technical specifications.............................................................................................................. 7
5. Installation..........................................................................................................................9
5.1 Mechanical installation................................................................................................................. 9
5.2 General installation guidelines ................................................................................................... 11
5.3 Electrical installation, M12 plug.................................................................................................. 12
5.4 Electrical installation, M16 cable gland ...................................................................................... 12
6. Setup.................................................................................................................................13
6.1 Manual teach-in ......................................................................................................................... 13
7. Dimensional Drawings....................................................................................................14
7.1 Dimensional drawings ............................................................................................................... 14
8. Troubleshooting ..............................................................................................................16
8.1 Troubleshooting......................................................................................................................... 16
9. Ordering............................................................................................................................17
9.1 Ordering key table ..................................................................................................................... 17
9.2 Certificates table ....................................................................................................................... 18
10. General information........................................................................................................ 19
10.1 Service / Repair ....................................................................................................................... 18
10.2 Warranty.................................................................................................................................. 18
10.3 How to contact Alfa Laval Kolding A/S ....................................................................................18

Page 3 Instruction Manual, Alfa Laval Level Switch
TE91K023-EN5
The designated company
hereby declare that
is in conformity with the
- EMC directive 2004/108/CE
- FDA 21CFR177.2415
and the following EU directives:
- EN61000-6-2, EN61000-6-3, Pressure Directive 2014/68/EU, EN10/2011, 1935/2004, 2023/2006
The person authorised to compile the technical file is the signer of this document.
This Declaration of Conformity replaces Declaration of Conformity dated 2019-02-01
1. EC Declaration of Conformity
Alfa Laval Kolding A/S
Company name
Albuen 31, 6000 Kolding, Denmark
Address
+45 79 32 22 00
Phone no.
Alfa Laval Level switch TE67Oxxxxxxxxx
Denomination Type
valid for serial numbers from 2019-00001 and subsequent serial numbers.
Global Product Quality Manager
Pumps, Valves, Fittings and
Tank Equipment Lars Kruse Andersen
Title Name Signature
April 1, 2019 Kolding
Date Place

Page 4 Instruction Manual, Alfa Laval Level Switch
TE91K023-EN5
2. Safety
2.1 Important information
Always read the manual before using the level switch
WARNING
Indicates that special procedures must be followed to avoid severe personal injury.
CAUTION
Indicates that special procedures must be followed to avoid damage to the level switch
NOTE
Indicates important information to simplify or clarify procedures
Unsafe practices and other important information are emphasized in this manual.
Warnings are emphasized by means of special signs. All warnings in the manual are summarized on this page.
Pay special attention to the instructions below so that severe personal injury or damage to the transmitter is avoided.
2.2 Warning signs
General warning:
Dangerous electrical voltage:
Caustic agents:

Page 5 Instruction Manual, Alfa Laval Level Switch
TE91K023-EN5
2. Safety
2.3 Safety instructions
This instrument is built and tested according to the current EU-directives and packed in technically safe condition.
In order to maintain this condition and to ensure safe operation, the user must follow the hints and warnings given in
this instruction.
During the installation the valid national rules have to be observed. Ignoring the warnings may lead to severe personal
injury or substantial damage to property.
The product must be operated by trained staff. Correct and safe operation of this equipment is dependent on proper
transport, storage, installation and operation.
All electrical wiring must conform to local standards. In order to prevent stray electrical radiation, we recommend
twisted and shielded input cables, as also to keep power supply cables separated from the input cables. The
connection must be made according to the connecting diagrams.
Before switching off the supply voltage check the possible effects on other equipment and the processing system.
Ensure that the supply voltage and the conditions in the environment comply with the specification of the device.
This instruction manual is part of the device, must be kept nearest its location, always accessible to all employees.
This instruction manual is copyrighted. The contents of this instruction manual reflect the version available at the time
of printing. It has been issued to our best knowledge. However, errors may have occurred. Alfa Laval Kolding A/S is
not liable for any incorrect statements and their effects.
– Technical modifications reserved – Limitation of liability
By non-observance of the instruction manual, inappropriate use, modification or damage, no liability is assumed and
warranty claims will be excluded.
Unsafe practices and other important information are emphasized in this manual.
Warnings are emphasized by means of special signs. All warnings in the manual are summarized on this page.
Pay special attention to the instructions below so that severe personal injury or damage to the transmitter is avoided.

Page 6 Instruction Manual, Alfa Laval Level Switch
TE91K023-EN5
3. General Description
3.1 Working principle of the level switch
The media acts as a virtual capacitor from the sensor tip to the metal shaft or the welding part.
An electrode inside the sensor tip builds a capacitor together with the surroundings. The medium with its dielectric
constant (DC value) is defining the capacitance value. A resonance circuit is created in combination with a coil in the
sensor head. Switching signal tripping is according to the measured resonance frequency and the programmed
trigger thresholds.
Alfa Laval level switch TE67O is designed for level detection in tanks and dry-run protection of pumps by empty pipe
monitoring. It detects liquid, pasty or oily media, but also solid-bulk materials like flour or plastic granulate. The TE67O
is capable of media differentiation by distinguishing the specific properties, such as oil, water, foam and liquid.
Reliable performance is assured in any mounting position (from top, bottom or side). Depending on the desired process
connection, different mounting options are available. Corresponding mounting aids and adaptors for conventional pro-
cess connections are available as an accessory.
The switching output is available as Normally Open (NO) and Normally Closed (NC) can be selected by re-connecting
the electronics (please see page 12)
The Alfa Laval level switch TE67O is default configured to cover the major part of potential applications. Where custom-
er-specific configuration is required because of difficult media (e. g. foamy or adhering), the interface programming tool
Alfa Laval Instrument Programmer (9614448501) allows for easy parameterization of the optimum switching point by
convenient teach-in functionality. The measured data can be visualized on a PC for further parameter adjustment, for
example time constant of a damping function and inverted switching output logic.
3.3 Recycling information:
Unpacking
Packing material consists of plastic and cardboard boxes.
Cardboard boxes can be reused, recycled or used for energy recovery.
Plastics should be recycled or burnt at a licensed waste incineration plant.
Maintenance
During maintenance seals and O-ring should be replaced (only on clamp connections).
All metal parts should be sent for material recycling.
Worn out or defective electronic parts should be sent to a licensed handler for material recycling.
Oil and all non metal wear parts must be taken care of in agreement with local regulations
Scrapping
At end of use, the equipment shall be recycled according to relevant, local regulations. Beside the equipment
itself, any hazardous residues from the process liquid must be considered and dealt with in a proper manner.
When in doubt, or in the absence of local regulations, please contact the local Alfa Laval sales company.
3.2 General description

Page 7 Instruction Manual, Alfa Laval Level Switch
TE91K023-EN5
4. Technical specifications
4.1 Level switch
Technical specifications
Ambient conditions
Operating temperature range -40 ... 115 °C (up to 200 °C with sliding connection)
Storage temperature range -40 ... 85 °C
Humidity (IEC 68-2-38) < 98 % RH, condensing
Protection class (IEC 60529) IP67
IP69K (with appropriate cable)
Vibration IEC 60068-2-6
GL Test 2
Process connection
Connection variants Refer to dimensional drawings (page 14)
Mounting position Any (top, bottom, side)
Wetted parts material PEEK Natura
AISI 316L (1.4404)
AISI 304 (1.4301) (optional)
Surface roughness wetted parts Ra < 0.8 μm
Process conditions
Process temperature Refer to table (page 8)
Process pressure Refer to table (page 8)
Electrical connection
Electrical connection
Connector variants M12, 4 pin, polycarbonate
M12, 4 pin, stainless steel
Cable outlet 5 m, 4-wire, PVC
Power supply
Voltage supply range 12 ... 30 V DC
Current consumption (no load) 25 mA typ., 50 mA max.
Reverse polarity protection Yes
Power-up time < 2 s
Output signalization
Switching polarity PNP
Current rating 20 mA max.
Short circuit protection Yes
Voltage drop PNP: (+Vs -1.5 V) ± 0.5 V, Rload = 10 kΩ
Off leak current ± 100 μA max.
Switching logic Normally open (NO)
Normally closed (NC)

Page 8 Instruction Manual, Alfa Laval Level Switch
TE91K023-EN5
4. Technical specifications
Sensor performance
Repeatability ± 1 mm
Hysteresis ± 1 mm
Response time 0.1 s typ. (0.15 ± 0.05 s)
Damping 0.0 ... 10.0 s (adjustable)
Factory setting
Switching range
(dielectric constant DC)
0 … 75,3 % (DC > 2)
Trigger level 80,4%
Trigger hysteresis 1,6%
Range hysteresis 2,4%
Output type PNP
Output polarity AUTO
Damping 0.1 s
Compliance and approvals
Apply to
EMC directive 2004/108/CE
EU directives EN61000-6-2, EN61000-6-3, PED 2014/68/EU,
EN10/2011, 1935/2004, 2023/2006
FDA FDA 21CFR177.2415
Approvals
Hygienic 3-A Standard 74-07 on some models, see Chapter 9
Safety cULus Listed, Class 2, E365692
Process
temperature
continuous
Tamb < 50 °C
Process
pressure Process
temperature
< 1 h
Tamb < 50 °C
Process
pressure @
max.
temperature
Type Process connection °C bar °C bar
TE67Ox4... G½ -20 … 115 -1 … 10 135 -1 … 40
TE67OxD... Clamp front flushable (CFF) -20 … 115 -1 … 40 135 -1 … 40
TE67OxE... G½, 100 mm sliding -40 … 200 -1 … 16 N/A N/A
TE67OxF... G½, 250 mm sliding -40 … 200 -1 … 16 N/A N/A
TE67OxM… Unique Flexbody, type F -20 … 115 -1 … 10 135 -1 … 10
TE67OxN… Unique Flexbody, type N -20 … 115 -1 … 10 135 -1 … 10

Page 9 Instruction Manual, Alfa Laval Level Switch
TE91K023-EN5
5. Installation
5.1 Mechanical Installation
The TE67O has several possibilities for mechanical mounting into the process.
It can de delivered with both hygienic clamp connections and non-hygienic versions.
Warning:
Install only the Alfa Laval level switch when the tank or pipe is depressurized and currentless.
Installation:
Carefully remove the level switch from the package.
Only use a suitable gasket or O-ring depending on the media
If the level switch has a G1/2” connection, there is no sealing
Tighten the process connection or clamp ring only with recommended torque (15 … 20 Nm for G1/2”)
Make sure that the level switch is placed so the electrical connector or cable gland is facing
downwards to avoid water ingress
Mounting of the 3-A approved CFF welding adaptor :
For the TE67O0Dx1111xx to be compliant to 3-A it must be installed in the welding adaptor
TE67N000000019.
The TE67N000000019 welding adaptor can be fitted on tanks and on pipes.
O-ring TE67N000000019
Mounting with Clamp DN38/DN51 (ISO2852):
The TE67O is available with either a DN38 or a DN51 clamp connection.
To ensure a correct measurement it is important to follow the guidelines of the installation.
When using a ISO2852 ferrule,it is important that the gasket is placed correctly to ensure a tight connection.
Follow these guidelines to ensure a good connection:
Always position the ferrule in a self draining position
On a vertical pipe, make sure that the ferrule is angled at least 5 degrees.
All weldings should be grinded to Ra = 0,8 µm
These standard Alfa Laval ferrules are recomended for the TE67O:
Item number
304L, 1.4307 Item number
316L, 1.4404 Size Dimensions
OD/ID x t Depth: (H)
9611310201 9166310200 DN38 (ISO2852) 38,6/35,6 x 1,5 21,5 mm.
9611310211 9166310210 DN51 (ISO2852) 51,6/48,6 x 1,5 21,5 mm. H
OD
ID

Page 10 Instruction Manual, Alfa Laval Level Switch
TE91K023-EN5
5. Installation
Mounting with Unique Flexbody Connection:
The TE67O is available with the Unique Flexbody connection which offer a 100% flush connection in tanks or in
combination with the Unique Flexbody body in any piping.
A/F 22
G 1/2 A
12 44
PEEK
AISI 316L
It is important that the installation comply to 3-A regulations which means that:
Only 3-A approved welding adaptor is to be used (TE67N000000019)
The inspection hole should be visible and drained
Mount the adapter in a self-drained position/angle
The 3-A mark or the arrow shall be placed upwards
Welding should be grinded to Ra=0.8
Welding according to appropriate 3-A standard
TE67N000000019 is also available with (these are not included in the 3-A authorization):
Electropolishing: TE67N000000020
3.1 certificate: TE67N000000037
Electropolishing + 3.1 certificate: TE67N000000038

Page 11 Instruction Manual, Alfa Laval Level Switch
TE91K023-EN5
5. Installation
5.2 General Installation Guidelines
After installation
Check the leak tightness of the sleeve/ferrule.
Check the tightness of glands or M12 plugs.
Check the tightness of the cover
When installed in tanks with a ISO2852 ferrule it is important
only to install it on vertical surfaces and with an angle of 5°
which makes it self draining
When installed in the bottom of tanks it is recommended to use
the CFF process connection (TE67N000000019) or the Unique
Flexbody connection to get a flush mounting without any dead
legs.
Tank Installation:
Fitted
incorrect
Cannot be
drained
WARNING
Avoid dead legs:
Dead legs are areas around process connections which, because of misplacement of the connection, is very
hard to clean. Welding adaptors must always be placed in a way which makes them self drained and easy to
clean. This is done by keeping an angle of at least 5 degrees

Page 12 Instruction Manual, Alfa Laval Level Switch
TE91K023-EN5
5.3 Electrical installation with M12 connectors
1: Brown Supply (–)
2: White Teach in
3: Blue Supply (+)
4: Black Output, PNP
M12 4-pin connection
5.4 Electrical installation with M16 cable gland
5. Installation
Warning
Note: Check the maximum temperature for the cable used.
Cable diameter for M16 3...9 mm
+_
(-) (+)
Out T-in
43
12
Sensor Case
.
.
LED
+
-
PNP NC
L
+_
(-) (+)
Out T-in
+
-
PNP NO
L
+_
(-) (+)
Out T-in
LED

Page 13 Instruction Manual, Alfa Laval Level Switch
TE91K023-EN5
6. Setup
6.1 Manual Teach-In
Make sure that power is on before Teach-In.
For best Teach-In it is important the product is fixed in the final application.
During Teach-In mode the light intensity of the LED will increase, please protect your eyes.
Ste
p To do LED Result
2 With no media present connect
”Teach-In” to - VDC shortly
Light on for 2 second and then
flash
Register ”empty” state. Pls. See note
3 With media present connect
”Teach-In” to - VDC shortly Light on for 2 seconds Register ”full” state, stores the value and returns to
Normal operation with new setting
1 Connect terminal ”Teach-In” to
- VDC (T1 or T2) for 3,5 second Flash 1 time per second Ready for Teach-in
NOTE:
If the media is sticky, foamy, powdery or in other ways leaving parts of the media at the sensor tip this situation has to be
established also during the Teach-In process. Otherwise a faulty calibration can be the result.
If Teach-In for some reason do not succeed, the level Switch TE67O will enter “Error State” and automatically reload factory
settings . The factory settings can always be reloaded by connecting the terminal “Teach-In” to -VDC for more than 6.5 sec-
onds.
A reloaded factory settings will be confirmed by pulsing light intensity 3 times.
Error state Flushing
3 × short and 1 × long
Can normally be fixed by powering off and on and remake the Teach-In.
Alternatively remake the Teach-In configuration by use of the
Error state
description
LED Result
6.2 Teach-In with instrument programmer
The Alfa Laval instrument programmer (item number: 9614448501) is a dedicated tool to configure the level switch.
For instruction, please see separate manual for the Alfa Lavel instrument programmer.

Page 14 Instruction Manual, Alfa Laval Level Switch
TE91K023-EN5
7.1 Dimensional Drawings
7. Dimensional Drawings
PEEK
AISI 316L
13,5
EPDM
50,5
31,7 19
G 1/2 A
PEEK
AISI 316 L
ø15
PEEK
AISI 316 L
10 100 13
Safety
M16 M12
56Ø
58
A/F 22
G 1/2 A
12 44
PEEK
AISI 316L
Clamp front flushable (CFF)
(TE67O0Dx1110xx)
G½
(TE67O04x1110xx)
Ø 55 mm housing
(TE67Oxxxxxxxxx)
G½, 100 mm sliding (TE67OxExxxxxxx)
G½, 250 mm sliding (TE67OxFxxxxxxx)
G 1/2 A ø15
PEEK
AISI 316 L
PEEK
AISI 316 L
10 250 13
Safety
PEEK compression ring set
(Spare part No.: 9614462401)

Page 15 Instruction Manual, Alfa Laval Level Switch
TE91K023-EN5
7.1 Dimensional Drawings
7. Dimensional Drawings
ø44
34
ø65
34
ø56
34
Ø 64
34
34
50,5ø
Clamp DN 38 (ISO2852) / Clamp DN 40 (DIN32676)
(TE67O02x1110xx)
Clamp DN 51 (ISO2852) / Clamp DN 50 (DIN32676)
(TE67O03x1110xx)
DN 25 (DIN11851)
(TE67OxAxxxxxxx)
DN 40 (DIN11851)
(TE67OxBxxxxxxx)
DN 50 (DIN11851)
(TE67OxCxxxxxxx)
Unique Flexbody, type F,
DN 25
Unique Flexbody, type N, DN 40 …
DN 125

Page 16 Instruction Manual, Alfa Laval Level Switch
TE91K023-EN5
8. Troubleshooting
No electrical output from the sensor
In case of no electrical signal from the sensor please follow this checklist for identifying the problem.
Loosen and remove the cover
Measure if there is 10-35 VDC on the two supply terminals to make sure that there is power to the sensor
Check if wiring is according to the scedule on p. 12
If all of these points is checked, and the sensor still have an error, the level switch needs to be returned to Alfa Laval for
repair.
8.1 Troubleshooting

Page 17 Instruction Manual, Alfa Laval Level Switch
TE91K023-EN5
9. Ordering
9.1 Ordering Key Table
TE67O - Level Switch
Ordering key table Alfa Laval Level Switch
Description Option Item nr. code
Basic price Basic instrument TE67Oxxxxxxxxx
Measuring Range N/A TE67O0xxxxxxxx
Process connection Clamp DN 38 (ISO2852) / Clamp DN 40 (DIN32676) TE67Ox2xxxxxxx
Clamp DN 51 (ISO2852) / Clamp DN 50 (DIN32676) TE67Ox3xxxxxxx
G½ TE67Ox4xxxxxxx
DN 25 (DIN11851) TE67OxAxxxxxxx
DN 40 (DIN11851) TE67OxBxxxxxxx
DN 50 (DIN11851) TE67OxCxxxxxxx
Clamp front flushable (CFF) TE67OxDxxxxxxx
G½, 100 mm sliding TE67OxExxxxxxx
G½, 250 mm sliding TE67OxFxxxxxxx
Unique Flexbody, type F - DN 25 (1”) TE67OxMxxxxxxx
Unique Flexbody , type N - DN 40...DN 125 (1½” … 6”) TE67OxNxxxxxxx
Surface finish Ra<0,8µ TE67Oxx1xxxxxx
Ra<0,4µ (Electropolished) TE67Oxx2xxxxxx
Surface material AISI316L and PEEK TE67Oxxx1xxxxx
Powersupply 12,5..36 VDC TE67Oxxxx1xxxx
Electrical output Digital out, PNP NO (50 mA.) TE67Oxxxxx1xxx
Electronical features TE67Oxxxxxx0xx
Others M12 Connector, Stainless Steel TE67Oxxxxxxx3x
Cable gland M16, Plastic TE67Oxxxxxxx4x
Cable gland M16, Stainless Steel TE67Oxxxxxxx5x
Certificates None TE67Oxxxxxxxx0
3.1 Certificate TE67Oxxxxxxxx2

Page 18 Instruction Manual, Alfa Laval Level Switch
TE91K023-EN5
9.2 Certificates Table
Available certificates
Item code Process Connection 3-A Calibration 3.1
TE67O02x1110xx Clamp DN 38 (ISO2852) / Clamp DN 40 (DIN32676) X X X
TE67O03x1110xx Clamp DN 51 (ISO2852) / Clamp DN 50 (DIN32676) X X X
TE67O04x1110xx G½ Hygienic X X X
TE67OxExxxxxx2 G½, 100 mm sliding X
TE67OxFxxxxxx2 G½, 250 mm sliding X
TE67OxAxxxxxx2 DN 25 (DIN11851) X
TE67OxBxxxxxx2 DN 40 (DIN11851) X
TE67OxDxxxxxx2 DN 50 (DIN11851) X
TE67O0Dx1110xx Clamp front flushable (CFF) X X X
TE67O0Mx1110xx Unique Flexbody, type F - DN 25 (1”) X X
TE67O0Nx1110xx Unique Flexbody, type N - DN 40...DN 125 (1½” … 6”) X X
3-A Approval is only valid with a 3-A approved welding part
3-A Certificate Authorization number: 1536
A copy of the certificate can be downloaded from 3-A Sanitary Standards, Incorporated

Page 19 Instruction Manual, Alfa Laval Level Switch
TE91K023-EN5
10. General information
The product contains no direct replaceable parts. In case of malfunction the product must be sent to Alfa Laval for
repair.
The PEEK compression rings for the sliding connection need to be replaced if they are deformed.
(part number pls. see page 14).
Upon every return of product, no matter if for modifications or repair, it is necessary to contact you local
Alfa Laval office to guarantee a quick execution of your request.
You will receive instructions regarding the return procedure from your local Alfa Laval office.
Be sure to follow the instructions closely.
10.1 Service / Repair
10.2 Warranty
The warranty conditions are subject to the legal warranty period of 12 months from the date of delivery. In
case of improper use, modifications of or damages to the device, we do not accept warranty claims.
Damaged devices will also not be accepted. Furthermore, defects due to normal wear are not subject to
warranty services.
10.3 How to contact Alfa Laval Kolding A/S
For further information please feel free to contact:
Alfa Laval Kolding A/S
31, Albuen - DK 6000 Kolding - Denmark
Registration number: 30938011
Tel switchboard: +45 79 32 22 00 - Fax switchboard: +45 79 32 25 80
www.toftejorg.com , www.alfalaval.dk - info.dk@alfalaval.com
Contact details for all countries are continually updated on our websites.

Page 20 Instruction Manual, Alfa Laval Level Switch
TE91K023-EN5
Table of contents
Other Alfalaval Switch manuals