Safety Instructions
Only connect to alternating
current 100 - 240 V
•Electricalworktobedonebyaqualified
experttakingdueconsiderationofexisting
nationalsafetyregulations.
•Inroomswithshowersandbaths,themirror
hastobeinstalledinconsiderationofthe
safetydistancesaccordingtotheEN60364-
7-7011995regulations.
•Thewallbracketshouldbefittedataheight
ofatleast150cmabovethefloor.
•InOrdertoinsureIP44protectionplease
makesurethemountingsurfaceofthe
wallissmoothtoallowforaflushfitofthe
mountingbrackettothewall.Awavyrough
plasterisnotsufficienttoensureIP44
protection.
If this is not possible than please see
mounting Zone 3 for proper location for
installation.
•Anybreakageorsignificantcrackinginthe
sealedswitchcoverwillnullifytheIP44
rating.
If this occurs then the mirror unit must be
moved to a Zone 3.