ALPHA WORKS GUR052 User manual

ALPHAWORKS
SMART CORD REEL
OPERATOR' MANUAL
F
CC
ID:
2A
W
8
R
C
R
400
IC:26378-CR400


1
TECHNICAL DETAILS
Item No. AWG Length (ft) Volt (V) Ampere (A)
GUR052 12 65 125 15
SAFETY PRECAUTIONS
Read carefully and understand all INSTRUCTIONS
before operating. Failure to follow the safety rules
and other basic safety precautions may result in
serious personal injury.
Save these instructions in a safe place and on hand
so that they can be read when required. Keep these
instructions to assist in future servicing.
The warnings, cautions, and instructions discussed
in this instruction manual cannot cover all possible
conditions or situations that could occur. It must be
understood by the operator that common sense
and caution are factors which cannot be built into
this product, but must be supplied by the operator.
CORD REEL SAFETY PRECAUTIONS
1.
Ensure that only the qualified electrician can installs/services this cord reel. And it must not
be used by children or unskilled persons.
2.
Ensure that power supply voltage does not exceed maximum voltage rating of reel.
3.
Ensure that reel is properly be installed before connecting to power supply.
4.
Ensure that all electrical power is removed from reel before servicing.
5.
Check for frayed and broken wires before each use.
6.
When pull electrical cord from the reel always grasp the electrical cord itself, not the work
device.
7.
Remove power from the reel immediately when any malfunction occurs.
8.
Never remove, tamper with or cut the safety devices fitted by the manufacture.
9.
Do not use the reel in damp or wet conditions. Keep the work area is clean.
14.42
8.78
7.80
4- 0.413
14.173
14.464
14.637
10.22
12.866

2
FCC Matters Needing Attention
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
Caution: Changes or modifications to this unit not expressly approved by the party responsible
for compliance could void the user's authority to operate the equipment.
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation,
Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to
the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause
undesired operation of the device.
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux
CNR d’Innovation, Sciences et Développement économique Canada applicables aux appareils
radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes :
1、 L’appareil ne doit pas produire de brouillage;
2、 L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.
NOTE: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
—Consult the dealer or an experienced radio/TV technician for help.
To satisfy FCC&IC RF exposure requirements, a separation distance of 20 cm or more should
be maintained between the antenna of this device and persons during device operation.
To ensure compliance, operations at closer than this distance is not recommended.
Les antennes installées doivent être situées de facon à ce que la population ne puisse y être
exposée à une distance de moin de 20 cm. Installer les antennes de facon à ce que le
personnel ne puisse approcher à 20 cm ou moins de la position centrale de l’ antenne.

3
INSTALLATION
1.
Unpack and inspect reel for damage. Check for completeness.
2.
The cord reel must be installed in premises comforming to current regulation and standards
covering systems and work environments.
3.
Secure the cord reel to the wall and the ceiling according to the installation diagrams.Using
screw anchors or suitable screws which must be fitted in the holes in the brackets.
4.
The appliance can also be used on the ground. The cord reels can be placed in place as
needed.
In the ceiling on the wall
on the ground
OPERATION
1.
Check reel for correct operation by slowly pulling out the cord.
2.
To latch the reel, slowly pull out the cord to any point, release the cord to stop.
Note: It can not exceed the back end mark when the cord is pulled out.

4
CHECKLIST BEFORE USING THE DEVICE
1.
In order to power up the sockets, first click each button, and check whether the indicator
lights are working.
2.
Your smart phone or tablet should have connected a 2.4G WIFI with internet.
3.
The device only supports 2.4G network. Please don’t connect to a 5G network or hybrid
network.
4.
Enter correct WIFI passwords. Make sure that your WIFI SSID and passwords don’t contain
special characters.
5.
During pairing process, make sure that your IOS or Android device and smart socket within
the range of the router.
6.
Please pay attention to the maximum power that this socket.
Retract the cord
1.
Principal control: Press button 2 on the body and the cord can retracts. (pictured below)
2.
Socket control:
2.1.
2.2. Press any of the 3 socket buttons to control the current flow of each socket.
The indicator lights are green
whileworking, and the RF
indicator will flash.
RF Button
Socket
Socket
Button 3
Button 1 Socket
Button 2
2
1
Press both the RF button the cord can retracts.(If the cord can't retracts,need to
reconnect RF,Press the main body buttons 2 for more than 4 seconds, Then press
any button at the socket end,When the light flashes, the connection is successful.
(pictured below)



7
6.
Control device
1.
Tap to enter it’s control page, click on the button for
ON / OFF operations. Each socket can be
independently controlled and customized through
the app. And individually control each socket using
sepatate buttons. Rename what you want by click
the icon.
2.
In the control page you could click on the Timing &
Countdown etc., for regularly operations.
Stopped
Retract Button
Socket On/Off
Timing & Countdown
MAINTENANCE
1.
Make sure the Cord is in proper working order.
2.
Clean the Cord with a cloth dipped in warm water to remove dirt or deposits and ensure
correct rewinding.
3.
Do not use detergents or solvents which could prove incompatible with cord-winder
materials.
4.
Dismantling of the unit by unskilled personal could prove hazardous;the risk involved mainly
concerm the preloaded springs.
LIMITED WARRANTY
1.
The manufacturer warrantees this Cord reel against defects in material and craftsmanship,-
for a period of 12 months from date of purchase.
2.
Manufacturer’s liability is limited to replacement or repair of defective material within the
warranty period,when returned freight prepaid to the distributor or their designated service
depot.
3.
The warranty dose not cover damage caused by accident, misuse or faulty installation.
4.
The reel must be installed and maintained in compliance with the instructions.
Your risk from these exposures varies, depending on how often you do this type of work. To
reduce your exposure to these chemicals: work in a well ventilated area, and work with
approved safety equipment, such as those dust masks that are specially designed to filter out
microscopic particles.
Other manuals for GUR052
1
Table of contents
Other ALPHA WORKS Cables And Connectors manuals
Popular Cables And Connectors manuals by other brands

Festo
Festo NEBM-M12G8-E S1G9-V4 Series Assembly instructions

S6
S6 HVS-6204 user manual

nvent
nvent RAYCHEM BTV Installation and maintenance manual

Siemens
Siemens 6FX2003-0DE01 Assembly instructions

CableMax
CableMax DASL-102 user manual

National Instruments
National Instruments IMAQ D6826 installation guide