16
Malfunction analysis
Error Code
● When air conditioner status is abnormal, temperature indicator on indoor unit will
ation of error code.
Indoor display
Error code
Above indicator diagram is only
for reference. Please refer to
actual product for the actual
indicator and position.
■ When below phenomenon occurs, please turn off air conditioner and discon-
for service.
● Power cord is overheating or damaged.
● There’s abnormal sound during operation.
● Circuit break trips off frequently.
● Air conditioner gives off burning smell.
● Indoor unit is leaking.
■ If the air conditioner operates under abnormal conditions, it may cause
Warning
Below listed error codes are only part error codes. Please refero to error code
list in serive manual for more information.
Error code
C5 (After energization, the buzzer will give out
sound when operating remote controller, while
the complete unit doesn't work. Indicator is OFF.)
: Malfunction of connector jumper
F1 (Cooling indicator flashes 1 time every 3s):
Malfunction of indoor ambient temperature sensor
F2 (Cooling indicator flashes 2 times every 3s):
Malfunction of evaporator temperature sensor
Troubleshooting
Means defrosting status. It’s the normal phenomenon.
Heating indicator ON 10s OFF 0.5s
(Note: This dispaly is not
available for some models.)
Check if the connector jumper contacts properly.
If the PCB is to be replaced, please take off the
old for the new PCB.
Check if indoor room temperature sensor is
connected properly.
Check if the evaporator temperature is connected
properly.
H6 (Power indicator flashes 11 times every 3s):
Indoor fan block
Replace the fan motor or the indoor board if disabled.
Check if the terminal of the indoor motor is conne-
cted properly.
Note: If there're other error codes, please contact qualified professionals for service.
E5 (power indicator flashes 5 times every 3s)
E8 (power indicator flashes 8 times every 3s)
U8 (power indicator flashes 17 times every 3s)
Please contact qualified professionals for service.
Please contact qualified professionals for service.
Please contact qualified professionals for service.
Defrosting or oil return mode It is normal. The indicating lamp in heat mode will
wink 0.5s and light 10s.