ALTHEN Protran PR3850 User manual

Protran® PR3850 User Manual
3
5
8
ALTHEN GmbH Mess- und Sensortechnik
Dieselstrasse 2 | 65779 Kelkheim | Germany
Phone: +49 (0)6195 7 00 60 | Fax: +49 (0)6195 70 06 66
Email: [email protected] | www.althensensors.com
Safety &
Maintenance
General
Information
Product
Instructions
ATEX Product
Instructions
Dimensions
15
Version &
Disclaimer
11
13
Vers. 22/6/Eng
Protran® PR3850 User Manual

.……..
………………...
.…………
…………….
…..……
………….
………………………..
……………
..............
ALTHEN GmbH Mess- und Sensortechnik
2
General Information................................................................................................................................................. 3
Product Coding Protocol........................................................................................................................................... 3
Intended Use.............................................................................................................................................................. 4
Safety.......................................................................................................................................................................... 5
Maintenance and Care............................................................................................................................................. 6
Troubleshooting........................................................................................................................................................ 7
Recycling.................................................................................................................................................................... 7
Product Instructions................................................................................................................................................ 8
Connections and Tightening Torques.................................................................................................................... 9
ATEX Product Instructions................................................................................................................................... 11
Technical Specifications......................................................................................................................................... 14
Version Information............................................................................................................................................... 15
Disclaimer.................................................................................................................................................................. 15
Contents Page
Dimensions............................................................................................................................................................... 13
ESI Technology Limited
Sensor House, Wrexham LL13 7YP 2
Protran® PR3850 User Manual

General Information
Product Coding Protocol
CONNECTION
Coding detail Examples**
Model Code: PR8350 Flush Diaphragm Pressure Transmitter
PR3851
PR3852
Variant: EX ATEX / IECEx / M1 certified with DIN EN175301 plug & socket (4-20mA only)
Pressure Range: 00.1 0-100 mbar (1" BSP male with semi-flush membrane only)
0004 0-4 bar
0010 0-10 bar
0025 0-25 bar
0100 0-100 bar
0250 0-250 bar
0400 0-400 bar
BA 1/2" BSP male with flush membrane
BC 1" BSP male with semi-flush membrane (PR385x only)
Product code PR3850EX0025BA
example:
**For full scope of pressure ranges and process connections please refer to the technical specifications. For options
not listed please contact info@althen.de for support.
These operating instructions describe the safe and efficient handling and operation of the pressure transmitter or
transducer, and must be carefully read and understood prior to use.
Compliance with the specifications regarding safety and operation contained in these instructions is a prerequisite
for safe operation.
These operating instructions are part of the product. Failure to comply with the operating instructions will void the
manufacturer's liability in the event of damage.
For future reference, keep these instructions in an accessible location.
The standard coding for pressure transducers and transmitters is as follows:
MODEL VARIANT PRESSURE RANGE PROCESS CONNECTION
3
Protran® PR3850 User Manual

Intended Use
**For full scope of pressure ranges and process connections please refer to the technical specifications. For options
not listed please contact sales@esi-tec.com for support.
HAZARD
Type and Source of the hazard!
Consequence - Hazard potentially resulting in death, personal injuries and
damage to property
The pressure transmitter is designed for monitoring liquid and gaseous media within the limits specified in these
instructions.
For this purpose, the pressure transducer converts pressure applied to the pressure connection into an electrical
signal.
Please pay attention to the correct method of the sealing and process connection for the transmitter (see electrical
connections and threads)
Please take into account the environmental conditions such as temperature, humidity and atmospheric pressure,
etc.
Should be handled by qualified technical personnel only.
Limitation of Liability
The manufacturer is not liable for damage resulting from non-observance of these operating instructions.
Safety symbols
The explanations of the symbols used in these operating instructions are listed below:
Type and Source of the hazard!
Consequence - Hazard potentially resulting in minor personal injuries and
damage to property
WARNING
Type and Source of the hazard!
Notes, information and recommendations e.g. for trouble free operation
NOTICE
Type and Source of the hazard!
Consequence - Hazard potentially resulting in damage to property
CAUTION
4
Protran® PR3850 User Manual

Safety
WARNING
System may be under pressure!
Inadequate qualification of the personnel may lead to personal injuries or
damage to property.
Product application
The pressure transducer is intended to monitor liquid and gaseous media. For proper and safe application of the
product it is important to follow the specifications and warnings described in these operating instructions.
In addition to this installation guide, the specific safety regulations in the country in which the product is used apply.
Sensitive sensor technology
This product responds to environmental conditions.
In addition to the safety instructions included in this installation guide, local safety regulations apply.
Use the product in it's original state only, without making any unauthorised changes. Prior to the installation of the
product all transport materials, such as protective covers, caps or cardboard must be removed.
Handling with Oxygen
NOT for use with Oxygen
HAZARD
HAZARD
NOTICE
Handling with Hydrogen
NOT for use with Hydrogen
Selection of personnel
Only authorised and qualified personnel who have had experience and knowledge of the country-specific
regulations, as well as the applicable standards and directives, may be used for installation and operation.
Installation and commissioning must be carried out in accordance with these operating instructions.
The pressure transmitter is regarded as "electrical equipment"
Please comply with the specified limit values such as pressure ranges, overpressure safety, operating voltage and
temperatures. For current ranges please refer to product datasheet.
Examples of limit values
Overpressure safety PR3850 - 1.5x across all ranges
- Maximum pressure change rate < 1,0 bar/ms
- Please take into account the prevailing environmental conditions (temperature, humidity, atmospheric pressure,
etc)
- Please use the product in it's original state only. Do not carry out any unauthorised modifications.
- Remove any transport materials such as protective covers, caps or cardboard.
- Material compatibility should be considered. If in doubt, contact Althen sales.
5
Protran® PR3850 User Manual

Maintenance and Care
Scope of delivery and storage
Scope of delivery
Quantity Designation
1x Pressure transmitter
1x Calibration certificate
Storage
The pressure transmitter is maintenance-free. Nevertheless you should check the pressure transducer regularly
for excessive dirt and defects.
Recalibrations cycle depends on own industry guidelines. Zero and span adjustment is available.
WARNING
NOTICE
Repair work on the product must be carried out by the manufacturer only
Damage to the product!
Check the pressure transducer for damage when unpacking. If the pressure
transmitter is damaged, contact the manufacturer or your local dealer
immediately
WARNING
Improper storage!
Improper storage of the pressure transducer may result in damage or
malfunction of the product
WARNING
Ambient conditions during storage
- Temperature: +5°C to +40°C
- Store in dry conditions
System may be under pressure!
Loose parts and escaping media may cause personal injuries to the personnel
present. Ensure the pressure system is depressurised prior to starting any
clean work.
Cleaning
Clean the device using a damp cloth.
- Never use sharp or hard objects to clean the device.
- Do not insert or push any objects into the pressure connection hole
6
Protran® PR3850 User Manual

Troubleshooting
Error Possible cause Possible remedial action
- - Switch on supply voltage
- - Check cable
- - Check correct polarity
- -
- -
- -
- - Adhere to temperature range
- - Replace transmitter
- - Clean pressure inlet hole
- -
-
- - Replace transmitter
-
Dispose of the product and transport packaging materials according to applicable
disposal regulations specific to the respective country. Upon request, used parts can
be taken back free of charge and disassembled, disposed of and recycled in
accordance with the legal regulations
Eliminate or reduce EMC interference
sources
Additional EMC precautions e.g. shielding
Recycling
Output signal does
not change
Measuring cell damaged e.g. by
overpressure
Electronics failure e.g. by short
circuit
Adhere to temperature range
Replace transmitter
Clean pressure inlet hole
Signal span outside of
specification
Output signal
fluctuates/ noises
EMC interference sources outside
the specification
Operating outside of temperature
Measuring cell damaged e.g. by
overpressure
Pressure connection hole blocked
Zero point signal
outside of specification
Measuring cell damage
Operating outside of temperature
range
Pressure connection hole blocked
After removal!
After removal, there may be residual media in and at the pressure connection
that can endanger persons and the environment.
Please take appropriate precautions.
WARNING
Line interrupted/ disconnected
No supply voltage
In case of malfunctions, first check that the pressure transmitter is mounted correctly. The table shows the most
common faults and malfunctions and how they can be rectified.
No output signal
Polarity reversal
7
Protran® PR3850 User Manual

Product Instructions - General
INTENDED USE
ELECTRICAL CONNECTION AND ADJUSTMENT
MECHANICAL INSTALLATION
PR3850 SERIES
DISCLAIMER
Althen operates a policy of continuous improvement
and product development. We reserve the right to
change specification and operating instructions
without prior notice.
Please observe applicable safety regulations when installing
or removing pressure transmitter.
Please refer to datasheet, calibration certificate
and read installation instructions before starting
installation
The device must be used within the specified
pressure, temperature and supply voltage
range.
INSTALLATION
During installation please comply with the
relevant national guidelines
Installer must be technically competant and
familiar with pressure monitoring technology
Ensure electrical connector and cable gland are
securely fitted and sealed
MAINTENANCE
Recalibration interval depends on own industry
guidelines
Do not insert pointed or hard objects in to the
pressure port
Repairs must be performed by manufacturer
only
REMOVAL/ END OF LIFE
Ensure system is depressurised before removal
Remaining media in pressure port may be
hazardous
Ensure system is not pressurised before
installation
Ensure that the measurement cell is not
damaged during installation
Use either a correct sized AF wrench on the
hexagon with tightening torque in accordance
with the table. The customer must ensure that
the pressure seal is suitable for application
WEEE can be returned to factory at end of life
for recycling
Tightening torque setting guideline in table
overleaf
ELECTRICAL INSTALLATION
Make mechanical installations first so as not to
twist the cable
Refer to product calibration certificate for wiring
diagram
8
Protran® PR3850 User Manual

Connections and Tightening Torques
PR3850 SERIES
Process Connection
Sealing Method
Counter Part
Weld Socket / Part No.: 8016
Part No.: Z0093
O-Ring
Sensitive Membrane,
handle with care!
9
Protran® PR3850 User Manual

Torque Settings*
G1/2" BSPP male
(flush)**
G1" BSPP male
(semi-flush)
Thread Type All Pressures
Max. 50 Nm
For more information please contact info@althen.de
* The torque values apply only to test conditions and are a guide only. Tightening torques for
installation depend on many factors, including materials, lubrication, coating and surface treatment. If
in doubt the manufacturer is to be consulted.
** It is recommended that the PR3850 is used in conjunction with weld socket part No. 8016 for best
results. Alternatively customer may machine an appropriate mating connection in their equipment to
replicate the dimensions detailed in part 8016 (detailed diagrams available on request).
Materials for mating part should be selected to suit pressure and media requirements.
10
Protran® PR3850 User Manual
Tightening Torques

ll 1 GD
TRaC Certificate No.
Serial No :
Part No :
Range :
Output :
Ui = 28 V li = 119 mA Ci = xx Nf
Li = 0.1 Uh Pi = 0.65 W
TRAC12ATEX0060X V2
IECEXTRC12.0025X issue 01
**Arrangement of details can be altered to suit different housing types provided the content of the marking
remains unchanged. Year of manufacture shall precede the serial number.
When the product cannot be laser marked directly the product marking will be laser marked on to a stainless steel
plate which will be permanently fixed to the housing.
WARNING: POTENTIAL ELECTROSTATIC CHARGING HAZARD DUE
TO PROPOGATING BRUSH DISCHARGE - SEE INSTRUCTIONS
ATEX Product Instructions
Specified to hazardous area installations
(Reference European ATEX Directive 2014/34/EU, Annex II, 1.0.6.)
The following instructions apply to equipment covered by certificate numbers
TRAC12ATEX0060X V2, IECEXTRC12.0025X issue 01. The wording and format may be altered
providing the meaning remains unchanged.
All products were evaluated against standards:
- EN 60079-0:2012+A11:2013
- EN 60079-11:2012
- EN 60079-26:2015
- EN 50303:2000
- IEC 60079-0:2017
- IEC 60079-11:2011
- IEC 60079-26:2014
11
Protran® PR3850 User Manual

ATEX Product Instructions
1 The power source feeding the apparatus shall be an ATEX/IECEx approved barrier only
2
3
4
5
6
7
8
9
10
Additional Notes
Installation shall be carried out in accordance with the applicable code of practice by suitably-trained personnel.
If the equipment is likely to come into contact with aggressive substances, then it is the responsibility of the
user to take suitable precautions that prevent it from being adversely affected, thus ensuring that the type
of protection is not compromised.
For products other than PR3200 and PR3202 there are no special checking or maintenance conditions
other than a periodic check. These products which may have aluminium enclosures (powder coated)
should be located where friction sparks with steel objects are avoided. They should also be regularly
inspected to ensure the coating is not damaged
A A copy of certification marking as detailed on drawing number 8727.
B A copy of the EC type examination certificates TRAC12ATEX0060X V2, IECEXTRC12.0025X issue 01.
C Diagrams that may be necessary for safety, putting into service, maintenance, inspection etc.
D Where applicable, the address of the importer or repairer will be specified.
E On being put into service, the equipment will be accompanied by a translation of the instructions in the
language
or languages of the country in which the equipment is to be used and by the instructions in the original language.
F In addition to the wording normally applied (e.g. Clean Only With A Damp Cloth) the wording of the label shall
include the words ‘Warning: Danger of propagating brush discharge’ followed by the warning symbol ISO3864 No.
B.3.1 (black exclamation mark in black triangle, meaning: Caution, refer to accompanying documents). The
manufacturer’s instructions shall include details of the ignition hazard caused by propagating brush discharges and
the precautions to be taken to avoid the build up of static charge. (See note 6 above)
Aggressive substances -
Suitable precautions -
e.g. acidic liquids or gases that may attack metals or solvents that may
affect polymeric materials.
e.g. regular checks as part of routine inspections or establishing from
the material's data sheet that it is resistant to specific chemicals
For the maximum cable lengths stated the cable capacitance shall not exceed 200pF/m otherwise the
overall capacitance of Ci plus the cable capacitance shall not exceed 83nF
The equipment may be used with flammable gases, vapours and dust with apparatus group IIC and with
temperature class T4. The apparatus is not permitted for use with dusts that have a layer smouldering
temperature of 135oC or less.
The equipment may be used above surface Group II and Group III and in mining zone Group I.
The equipment is only certified for use in ambient temperatures in the range -20oC to +70 oC and should
not be used outside this range.
Propagating brush discharges are caused by non-conducting fluid flow over a non-conducting plastic
surface. The product shall not be installed in areas where a high fluid flow may occur (for example in the
case of a ruptured process pipe or compressed air pipe).
All repairs are to be carried out by Althen.
12
Protran® PR3850 User Manual

Dimensions
ELECTRICAL CONNECTION (mA)
Pin No. 4 wire 3 wire
1 -supply common
2 +supply +supply
3 +output +output
to case
Notes:
1. Item is shown for pictorial purpose only to define
citical dimensions
2. Construction shall be in accordance with
specification information
3. Label will show: product name, range and output
signal
Pin No.
1
2
3
2 wire
+supply
4-20mA sig.
N/C
to case
ELECTRICAL CONNECTION (Vdc)
13
Protran® PR3850 User Manual

Technical Specification
Type
Sensor Technology
Output signal
4-20mA (2 wire)
Load Drive Capability:
Accuracy NLHR:
Zero Offset and Span Tolerance:
Supply Voltage
13-36 Vdc
Pressure Reference
Protection of Supply Voltage:
Standard Pressure Ranges (bar):
Insulation Resistance:
Electromagnetic Compatibility:
> 100 MΩ @ 50 VDC
Operating Temperatures:
Storage Temperature:
PR3852
PR3851
0-10 V (4)
0-5 V (4 wire)
Ceramic thick film
13-30 Vdc
Gauge
Protected against supply voltage reversal up to 50 V
0-1 bar Vac; 0-0.5 bar; 0-1 bar; 0-2.5 bar; 0-6 bar; 0-10 bar; 0-16 bar; 0-25 bar; 0-100 bar;
0-250 bar; 0-400 bar; 0-600 bar; 0-1,000 bar; 0-1,500 bar (other ranges available)
1.5x for all pressure ranges
4-20 mA: RL < [UB - 13 V] / 20 mA; (e.g. with supply voltage (UB) of 36V max. load (RL) is 1150 Ω); 0-5
V: max load RL> 5 KΩ; 0-10 V: max load RL > 10 KΩ
≤ ±0.3 % of span BFSL
Temperature Effects: ±2.5% FS total error band for -20 °C to +70 °C.
+5 °C to +40 °C (+41 °F to +104°F) Recommended Best Practice
Ambient and Media: -20 °C to +85 °C (-4 °F to +185 °F)
±1.0% FS at room temperature; ±5% FS (approx.) adjustment with easy access trimming
potentiometers on amplified versions only
Overpressure Safety:
PR3850
(other options available)
Mating socket EN175301-803 Form A (ex DIN43650) rated IP65 with PG9 cable entry
Net. Weight (Kg):
0.3 Kg
Electrical Connection:
Response time 10-90%:
10 mS
Wetted Parts:
SAE 316L stainless steel
Pressure Media:
All fluids compatible with SAE 316L stainless steel
Pressure Connection:
1/2” BSP male (G1/2) with standard integral Viton o-ring seal and flush SAE 316L stainless steel
diaphragm or 1” BSP male with semi-flush SAE 316L Stainless steel diaphragm
(from 100 mbar up to 4 bar only)
Typical thermal zero and span coefficients ±0.04% FS/ °C
Temperature Effects:
Ex II 1 G Ex ia IIC T4 Ga (zone 0)
Ex II 1 D Ex ia IIIC T135°C Da (zone 20)
Ex I M 1 Ex ia I Ma (group 1 M1)
ATEX/IECEx Approval Option (4-20 mA
version only):
Ui = 28 V
Ii = 119 mA
Pi = 0.65 W
Li = 0.1 µH
Ci = 62 nF
Temperature Range = -20 °C to +70 °C
Max. cable length = 105 m
ATEX/IECEx Safety Values:
Emissions: EN61000-6-3; Immunity: EN61000-6-2; Certification: CE Marked
14
Protran® PR3850 User Manual

Version Information
Date of creation: May 2022
Document version: 22/6/Eng
- PR3850
- PR3851
- PR3852
Operation of this equipment should always be carried out by trained personnel and in accordance with the
manufacturers guidelines. Failure to do so will be at the users own risk. Althen will not be liable for any losses
and/ or damages incurred from inproper use of equipment.
Althen operated a policy of continuous product development. We reserve the right to change specification
without prior notice. All products manufactured by Althen are calibrated using precision calibration
equipment, traceable to national measurement standards.
Information provided within this manual is current and correct as of 01/09/2022.
15
Protran® PR3850User Manual
Table of contents
Popular Transmitter manuals by other brands

HETRONIC
HETRONIC MFSHL915 user manual

Vanderbilt
Vanderbilt IPAW6-10 installation instructions

Huba Control
Huba Control 713 operating instructions

Sennheiser
Sennheiser SKP 300 G3 instruction manual

ACK!
ACK! E-04 Pre-Installation Checklist

INVISIBLE FENCE
INVISIBLE FENCE ICT 775 Operation and installation manual