VSG/VSGX Installation & Maintenance
Troubleshooting
Check the following before proceeding to the other troubleshooting steps in this section:
• Ensure the gate is level and check for proper gate tension.
• Ensure the gate has enough clearance to operate normally.
• Check the wiring for loose or bad connections (VSGX models only).
• Perform routine maintenance as described in the Maintenance section below.
Symptom(s) Possible Cause(s) Solution(s)
Gate does not unlock. The VSGX gate is not receiving
an activation signal from the gate
activation switch.
Ensure the gate activation switch is properly connected to the gate
activation leads. Test the wires by doing a connectivity test. Also,
ensure that nothing is interfering with the wires to the activation
switch.
The VSGX gate's lock is sticking
or binding in the locked position.
Check the gate arm and latch post for level installation. Readjust
or reposition the posts for correct operation. For instructions, refer
to "Installation Steps" on page 8. Ensure the gate has enough
clearance to operate normally.
The VSGX gate's lock surfaces
are obstructed or damaged.
Check the lock surfaces on the arm and the latch post for debris.
Remove the debris if present and maintain the area to prevent future
mishaps. Also, check the lock surfaces for damage and replace
components as needed.
The VSGX gate's activation
switch is broken.
Test and replace the gate activation switch if necessary.
Gate does not unlock. The VSGX gate is not powered
on.
Measure the power supply for the proper power output. The power
supply must be putting out 12 VDC for the gate to operate properly
in the US. If outside the US, ensure the proper power output for your
country.
The VSGX gate is constantly
receiving an activation signal
from the gate activation switch.
Ensure the gate's activation switch is properly connected to the gate
activation leads. Test the wires by doing a connectivity test. Also,
ensure nothing is interfering with the wires to the activation switch.
Ensure the activation switch is fully functional. The switch must be a
momentarily normally closed switch to work with the VSGX gate.
The VSGX gate's lock surfaces
are obstructed or damaged.
Check the lock surfaces on the arm and the latch post for debris.
Remove the debris if present and maintain the area to prevent future
mishaps. Also, check the lock surfaces for damage and replace
components as needed.
The VSGX gate's lock
mechanism is defective.
Test the lock mechanism. Ensure the mechanism is connected to
the correct voltage for correct operation. Ensure the connection to
the activation switch is clear and functioning. Replace the lock if
necessary.
The VSGX gate's activation
switch is broken.
Test and replace the gate activation switch if necessary.
The gate does not
self-close and fails to
return to the center
(home) position.
The VSG/VSGX gate is not
properly lubricated.
Clean and lubricate the top bracket hinge point and lower pivot spring
hinge point. Refer to Maintenance.
The VSG/VSGX gate is not level. Check the gate arm and latch post for level installation. Readjust or
reposition the posts for correct operation. Refer to "Installation Steps"
on page 8.
The gate arm bearing is loose,
obstructed, or damaged.
Check the top bracket hinge and lower pivot spring hinge point for
debris. Remove any debris, if present.