AMC iAC User manual

User
Manual
iAC
Installation Power Amplier

Safety instructions
USER MANUAL iAC Installation Power Amplier
When using this electronic device, basic precautions
should always be taken, including the following:
1 Read all instructions before using the product.
2 Do not use this product near water (e.g., near a bathtub, washbowl, kitchen sink, in a
wet basement or near a swimming pool etc). Care should be taken that objects do not
fall into liquids and liquids would not be spilled on the device.
3 Use this device when you are sure that it has a stable base and it is xed securely.
4 This product, in combination with loudspeakers may be capable of producing sound
levels that could cause permanent hearing loss. Do not operate for a long period of
time at a high volume level or at a level that is uncomfortable. If you experience any
hearing loss or ringing in the ears, you should consult with otorhinolaryngologist.
5 The product should be located away from heat sources such as radiators, heat vents,
or other devices that produce heat.
6 Note for power connections: for pluggable equipment, the socket-outlet shall be
installed near the equipment and shall be easily accessible.
7 The power supply should be undamaged and never share an outlet or extension
cord with other devices. Never leave device plugged into the outlet when it is not
being used for a long period of time.
8 Power disconnection: when the power cord connected to the power grid is
connected to the machine, the standby power is turned ON. When the power switch
is turned ON, the main power is turned ON.The only operation to disconnect the
power supply from the grid, unplug the power cord.
9 Protective Grounding - An apparatus with class I construction shall be connected to
a power outlet socket with a protective grounding connection.
Protective Earthing - An apparatus with class I construction shall be connected to a
mains socket outlet with a protective earthing connection.
10 The lightning ash with an arrowhead symbol, with an equilateral triangle,
is intended to alert the user to the presence of uninsulated dangerous
voltage’within the products enclosure that may be of sucient
magnitude to constitute a risk of electric shock to persons.
11 The exclamation mark within an equilateral triangle is intended to alert the
user to the presence of important operating and maintenance (servicing)
instructions in the literature accompanying the appliance.
12 There are some areas with high voltage inside, to reduce the risk of electric shock
do not remove cover of the device or power supply.
The cover should be removed by the qualied personnel only.
13 The product should be serviced by qualied service personnel if:
– The power supply or the plug has been damaged.
– Objects have fallen into or liquid has been spilled on the product.
– The product has been exposed to rain.
– The product has been dropped or the enclosure damaged.

Table of contents
USER MANUAL iAC Installation Power Amplier
Before you start
Introduction......................................................................................................................................................2
Features................................................................................................................................................................2
Operation
Front/rare panel of iAC 120....................................................................................................................3
Front/rare panel of iAC 240 and iAC 360......................................................................................4
Front/rare panel of iAC 2X240..............................................................................................................5
Front panel functions.................................................................................................................................6
Rear panel functions...................................................................................................................................6
Parameters controls.....................................................................................................................................7
Control protocol ............................................................................................................................................8
Feedback protocol...............................................................................................................................9-10
Specications
General specications.............................................................................................................................10

USER MANUAL iAC Installation Power Amplier
Before you start
02
iAC ampliers with an integrated signal processor are designed for 100 V and low impedance
background music systems. The model line consists of single-channel and two-channel ampliers.
They all have an RS 232 control port for integration amplier with third-party automation systems.
Balanced Phoenix and stereo RCA input with audio link connection for easy installation, multiple
voltage output suitable for 4 Ω, 70 V, and 100 V speaker lines.
FEATURES
• Integrated signal processors
• RS232 control port
• for 100V and low impedance music systems
• Ability to control treble, middle, and bass tones
• Stereo RCA AUX input
• Muting function
• Locking function
• Stand-by mode
• Supports 4 Ω, 70 V and 100 V speaker installations

USER MANUAL iAC Installation Power Amplier 03
1. Stereo RCA & balanced Phoenix inputs |2. Link output |3. RS232 serial interface |4. Reset button |5. Main output |6. Main power connector
Front Panel | iAC 10
Rear Panel | iAC 120
1. Power button |2. LCD display |3. Rotary encoder |4. Signal, limiter & mute indicators
Operation
41 2 3
1 2 3 54 6

USER MANUAL iAC Installation Power Amplier
Rear Panel | iAC 240, iAC 360
Front Panel | iAC 240, iAC 360
1. Stereo RCA & balanced Phoenix inputs |2. Link output |3. RS232 serial interface |4. Reset button |5. Main output |6. Main power connector
1 2 3 54 6
Operation
1. Power button |2. LCD display |3. Rotary encoder |4. Signal, limiter & mute indicators
41 2 3
04

USER MANUAL iAC Installation Power Amplier
Front Panel | iAC 2X240
Rear Panel | iAC 2X240
1. Signal, limiter & mute indicators |2. Power button |3. LCD display |4. Rotary encoder
1. Mode switch |2. Stereo RCA & balanced Phoenix inputs |3. Link outputs |4. RS232 serial interface |5. Reset button |6. Main output |7. Main power connector
Operation
1 12 3 4
1 2 3 4 65 7
05

USER MANUAL iAC Installation Power Amplier
Front panel functions
LED INDICARTORS
THE SIGNAL INDICATOR illuminates when indicates an audio signal in the
amplier's input.
LIMITER INDICATOR - the amplier has a built-in audio signal limiter in order to
limit output power. In case if input audio signal exceeds the maximum amplitude
needful to achieve maximum power, the audio limiter reduces the audio signal level
to a safe value and indicates activity using LIMIT LED.
MUTE INDICATOR illuminated when mute function is activated. The red LED
indicates muted channel.
POWER BUTTON
Switch amplier power ON or OFF.
LCD DISPLAY
LCD screen displays main information about ampliers: volume level, tone
controls levels, muting, locking, stand by status or sync settings.
ROTARY ENCODER
Designated to adjust amplier parameters. Rotate the encoder to adjust
parameters and push it to enter the menu or sub-menu. Press and hold for a
second to return the default screen. Push rotary encoder shortly to select CH1
or CH2, hold it to activate the selected channel menu. In order to disable LOCK
mode press and hold the encoder for 5 seconds. Turn or press knob to get back
device from standby mode.
Rear panel functions
MODE SWITCH (iAC 2X240)
Amplier can be set to operate in 2 modes: 2 controllable channels or single
channel mode. Both selections can operate in 100 V line.
STEREO RCA & BALANCED PHOENIX INPUTS
RCA input for line level audio.
AMPLIFIER OUTPUTS
Audio outputs for 4 Ω, 70 V, and 100 V speaker lines. Only one output can be
used at the time. Operating amplier with more than one output may cause
damage the amplier or connected speakers.
RS232 SERIAL INTERFACE
Designed to control main function of iAC apliers by using serial interface.
RS232 protocol is listed in page 8.
RESET BUTTON
This button resets all amplier parameters to default values. To activate this
function, press and hold button for two seconds.
MAIN POWER CONNECTOR
Power connector for mains power.
05
Operation
2 CHANNEL
MODE
BRIDGE
MODE
06
100 V
240 W
COM 4 Ω 50 V 100 V COM 4 Ω 50 V 100 V
COM 4 Ω 50 V 100 V COM 4 Ω 50 V 100 V
100 V
240 W
100 V
480 W
100 V
240 W
COM 4 Ω 50 V 100 V COM 4 Ω 50 V 100 V
COM 4 Ω 50 V 100 V COM 4 Ω 50 V 100 V
100 V
240 W
100 V
480 W

USER MANUAL iAC Installation Power Amplier
05
One Knob To Control Everything
iAC 2x240 features graphic LCD display and a single rotary/push encoder allowing easy control of
all device parameters.
In normal operating mode
LCD shows volume of each channel
EQ adjustments can be made for each
channel individually
Keep current channel settings when
entering single channel (bridge) mode
Device can be activated with user input or
RS-232 command
Each channel can be individually muted Allows locking front panel controls to
prevent unauthorised access.
Menu system
3 band EQ
Single channel (bridge) mode
Active stand by mode
Muting Locking
Rotary/push encoder
Graphic LCD display
One Knob To Control Everything
iAC 2x240 features graphic LCD display and a single rotary/push encoder allowing easy control of
all device parameters.
In normal operating mode
LCD shows volume of each channel
EQ adjustments can be made for each
channel individually
Keep current channel settings when
entering single channel (bridge) mode
Device can be activated with user input or
RS-232 command
Each channel can be individually muted Allows locking front panel controls to
prevent unauthorised access.
Menu system
3 band EQ
Single channel (bridge) mode
Active stand by mode
Muting Locking
Rotary/push encoder
Graphic LCD display
One Knob To Control Everything
iAC 2x240 features graphic LCD display and a single rotary/push encoder allowing easy control of
all device parameters.
In normal operating mode
LCD shows volume of each channel
EQ adjustments can be made for each
channel individually
Keep current channel settings when
entering single channel (bridge) mode
Device can be activated with user input or
RS-232 command
Each channel can be individually muted Allows locking front panel controls to
prevent unauthorised access.
Menu system
3 band EQ
Single channel (bridge) mode
Active stand by mode
Muting Locking
Rotary/push encoder
Graphic LCD display
One Knob To Control Everything
iAC 2x240 features graphic LCD display and a single rotary/push encoder allowing easy control of
all device parameters.
In normal operating mode
LCD shows volume of each channel
EQ adjustments can be made for each
channel individually
Keep current channel settings when
entering single channel (bridge) mode
Device can be activated with user input or
RS-232 command
Each channel can be individually muted Allows locking front panel controls to
prevent unauthorised access.
Menu system
3 band EQ
Single channel (bridge) mode
Active stand by mode
Muting Locking
Rotary/push encoder
Graphic LCD display
One Knob To Control Everything
iAC 2x240 features graphic LCD display and a single rotary/push encoder allowing easy control of
all device parameters.
In normal operating mode
LCD shows volume of each channel
EQ adjustments can be made for each
channel individually
Keep current channel settings when
entering single channel (bridge) mode
Device can be activated with user input or
RS-232 command
Each channel can be individually muted Allows locking front panel controls to
prevent unauthorised access.
Menu system
3 band EQ
Single channel (bridge) mode
Active stand by mode
Muting Locking
Rotary/push encoder
Graphic LCD display
One Knob To Control Everything
iAC 2x240 features graphic LCD display and a single rotary/push encoder allowing easy control of
all device parameters.
In normal operating mode
LCD shows volume of each channel
EQ adjustments can be made for each
channel individually
Keep current channel settings when
entering single channel (bridge) mode
Device can be activated with user input or
RS-232 command
Each channel can be individually muted Allows locking front panel controls to
prevent unauthorised access.
Menu system
3 band EQ
Single channel (bridge) mode
Active stand by mode
Muting Locking
Rotary/push encoder
Graphic LCD display
One Knob To Control Everything
iAC 2x240 features graphic LCD display and a single rotary/push encoder allowing easy control of
all device parameters.
In normal operating mode
LCD shows volume of each channel
EQ adjustments can be made for each
channel individually
Keep current channel settings when
entering single channel (bridge) mode
Device can be activated with user input or
RS-232 command
Each channel can be individually muted Allows locking front panel controls to
prevent unauthorised access.
Menu system
3 band EQ
Single channel (bridge) mode
Active stand by mode
Muting Locking
Rotary/push encoder
Graphic LCD display
One Knob To Control Everything
iAC 2x240 features graphic LCD display and a single rotary/push encoder allowing easy control of
all device parameters.
In normal operating mode
LCD shows volume of each channel
EQ adjustments can be made for each
channel individually
Keep current channel settings when
entering single channel (bridge) mode
Device can be activated with user input or
RS-232 command
Each channel can be individually muted Allows locking front panel controls to
prevent unauthorised access.
Menu system
3 band EQ
Single channel (bridge) mode
Active stand by mode
Muting Locking
Rotary/push encoder
Graphic LCD display
Menu system
In normal operating mode, LCD shows the volume of each channel. Push the rotary encoder to enter the other
channel or back to the previous mode.
Push and hold the rotary encoder to enter the main menu and access more controls of parameters.
One Knob To Control Everything
iAC serie features a graphic LCD display and a single rotary/push encoder allowing easy control of all device parameters.
3 band EQ
EQ adjustments can be made
for each channel individually.
Muting
Each channel can be individually muted.
Sync Settings
The function allows to link both channels and copy settings from one channel to another in order to control both amplier
channels at once.
Lock
This function locks front panel control in order to prevent unauthorized access to the amplier control menu or volume adjusting.
To disable the function press and hold the rotary encoder for 5 seconds. Lock function aects front panel control only, serial
control and reset functions are not free of locking. Lock mode can be also enabled or disabled by using RS232 command.
Active stand by mode
Mutes amplier and turn o LCD display in order to save power. This mode is indicated by the red color LED inside the
power button. In order to disable standby mode turn or push the rotary encoder. The standby mode also can be enabled or
disables by using the RS232 command.
Operation
07

USER MANUAL iAC Installation Power Amplier
COM Port Settings
Baud Rate: 9600
Parity: None
Data Bits: 8
Stop Bits: 1
Flow Control: No
RS232 codes | Send Sequences
RS232 codes are listed in HEX
For iAC 120/240/360 models
Vol +
69 41 43 55 01 02 01 01 AA
Vol -
69 41 43 55 01 02 01 02 AA
Mute
69 41 43 55 01 02 01 A1 AA
Unmute
69 41 43 55 01 02 01 A0 AA
Treble +
69 41 43 55 01 06 01 01 AA
Treble -
69 41 43 55 01 06 01 02 AA
Middle +
69 41 43 55 01 11 01 01 AA
Middle -
69 41 43 55 01 11 01 02 AA
Bass +
69 41 43 55 01 05 01 01 AA
Bass -
69 41 43 55 01 05 01 02 AA
Stand By O
69 41 43 55 0D 10 01 00 AA
Stand By On
69 41 43 55 0D 10 01 01 AA
Lock On
69 41 43 55 0D 11 01 01 AA
Lock O
69 41 43 55 0D 11 01 00 AA
Status
69 41 43 55 0D FA 01 00 AA
Firmware Version
69 41 43 54 01 FF 01 00 AA
For iAC 2X240 model
Vol + Ch1
69 41 43 55 01 02 01 01 AA
Vol - Ch1
69 41 43 55 01 02 01 02 AA
Mute Ch1
69 41 43 55 01 02 01 A1 AA
Unmute Ch1
69 41 43 55 01 02 01 A0 AA
Treble + Ch1
69 41 43 55 01 06 01 01 AA
Treble - Ch1
69 41 43 55 01 06 01 02 AA
Middle + Ch1
69 41 43 55 01 11 01 01 AA
Middle - Ch1
69 41 43 55 01 11 01 02 AA
Bass + Ch1
69 41 43 55 01 05 01 01 AA
Bass - Ch1
69 41 43 55 01 05 01 02 AA
Vol + Ch2
69 41 43 55 02 02 01 01 AA
Vol - Ch2
69 41 43 55 02 02 01 02 AA
Treble + Ch2
69 41 43 55 02 06 01 01 AA
Treble - Ch2
69 41 43 55 02 06 01 02 AA
Middle + Ch2
69 41 43 55 02 11 01 01 AA
Middle - Ch2
69 41 43 55 02 11 01 02 AA
Bass + Ch2
69 41 43 55 02 05 01 01 AA
Bass - Ch2
69 41 43 55 02 05 01 02 AA
Mute Ch2
69 41 43 55 02 02 01 A1 AA
Unmute Ch2
69 41 43 55 02 02 01 A0 AA
Sync/Copy Ch1 To Ch2
69 41 43 55 01 01 01 01 AA
Operation
08
Sync/Copy Ch2 To Ch1
69 41 43 55 02 01 01 01 AA
Unsync
69 41 43 55 01 01 01 00 AA
Vol + Ch1 and Ch2
69 41 43 54 01 02 01 01 AA
Vol - Ch1 and Ch2
69 41 43 54 01 02 01 02 AA
Treble + Ch1 and Ch2
69 41 43 54 01 06 01 01 AA
Treble - Ch1 and Ch2
69 41 43 54 01 06 01 02 AA
Middle + Ch1 and Ch2
69 41 43 54 02 11 01 01 AA
Middle - Ch1 and Ch2
69 41 43 54 02 11 01 02 AA
Bass - Ch1 and Ch2
69 41 43 54 01 05 01 02 AA
Bass + Ch1 and Ch2
69 41 43 54 01 05 01 01 AA
Mute All
69 41 43 54 02 02 01 A1 AA
Unmute All With Ch2 Vol
69 41 43 54 02 02 01 A0 AA
Unmute All With Ch1 Vol
69 41 43 54 01 02 01 A0 AA

USER MANUAL iAC Installation Power Amplier 09
Sync/Copy Ch2 To Ch1
69 41 43 55 02 01 01 01 AA
Unsync
69 41 43 55 01 01 01 00 AA
Vol + Ch1 and Ch2
69 41 43 54 01 02 01 01 AA
Vol - Ch1 and Ch2
69 41 43 54 01 02 01 02 AA
Treble + Ch1 and Ch2
69 41 43 54 01 06 01 01 AA
Treble - Ch1 and Ch2
69 41 43 54 01 06 01 02 AA
Middle + Ch1 and Ch2
69 41 43 54 02 11 01 01 AA
Middle - Ch1 and Ch2
69 41 43 54 02 11 01 02 AA
Bass - Ch1 and Ch2
69 41 43 54 01 05 01 02 AA
Bass + Ch1 and Ch2
69 41 43 54 01 05 01 01 AA
Mute All
69 41 43 54 02 02 01 A1 AA
Unmute All With Ch2 Vol
69 41 43 54 02 02 01 A0 AA
Unmute All With Ch1 Vol
69 41 43 54 01 02 01 A0 AA
Function Start Channel
Byte
Functions
Bytes Value Bytes End
VOLUME 69 41 43 55 02 5D 02
00 (= 0 db)
01 (= 1 db)
02 (= 2 db)
03 (= 3 db)
04 (= 4 db)
05 (= 5 db)
06 (= 6 db)
07 (= 7 db)
09 (= 8 db)
09 (= 9 db)
0A (= 10 db)
0B (= 11 db)
0C (= 12 db)
0D (= 13 db)
0E (= 14 db)
0F (= 15 db)
10 (= 16 db)
11 (= 17 db)
12 (= 18 db)
13 (= 19 db)
14 (= 20 db)
15 (= 21 db)
16 (= 22 db)
17 (= 23 db)
18 (= 24 db)
19 (= 25 db)
1A (= 26 db)
1B (= 27 db)
1C (= 28 db)
1D (= 29 db)
1E (= 30 db)
1F (= 31 db)
20 (= 32 db)
21 (= 33 db)
22 (= 34 db)
23 (= 35 db)
24 (= 36 db)
25 (= 37 db)
26 (= 38 db)
27 (= 39 db)
28 (= 40 db)
29 (= 41 db)
2A (= 42 db)
2B (= 43 db)
2C (= 44 db)
2D (= 45 db)
2E (= 46 db)
2F (= 47 db)
30 (= 48 db)
AA
TREBLE 69 41 43 55 02 5D 06
00 (= -14)
01 (= -12)
02 (= -10)
03 (= -8)
04 (= -6)
05 (= -4)
06 (= -2)
07 (= 0)
0E (= +2)
0D (= +4)
0C (= +6)
0B (= +8)
0A (= +10)
09 (= +12)
08 (= +14)
Function Start Channel
Byte
Functions
Bytes Value Bytes End
MIDDLE 69 41 43 55 02 5D 11
00 (= -14)
01 (= -12)
02 (= -10)
03 (= -8)
04 (= -6)
05 (= -4)
06 (= -2)
07 (= 0)
0E (= +2)
0D (= +4)
0C (= +6)
0B (= +8)
0A (= +10)
09 (= +12)
08 (= +14)
AA
BASS 69 41 43 55 02 5D 05
00 (= -14)
01 (= -12)
02 (= -10)
03 (= -8)
04 (= -6)
05 (= -4)
06 (= -2)
07 (= 0)
0E (= +2)
0D (= +4)
0C (= +6)
0B (= +8)
0A (= +10)
09 (= +12)
08 (= +14)
MUTE 69 41 43 55 02 5D 02 3F
MUTE
FEEDBACK 69 41 43 55 02 5D 01 FA 3F
SYNC CH2 to
CH1 is ON 69 41 43 55 02 5D 01 01
Operation
Receive Sequences
Function Start Channel
Byte
Functions
Bytes Value Bytes End
OFF 69 41 43 55
0D
5D 10 01
AA
ON 69 41 43 55 5D 10 00
LOCKED 69 41 43 55 5D 11 01
UNLOCKED 69 41 43 55 5D 11 00
MANUAL ON 69 41 43 55 5D 10 40
MANUAL OFF 69 41 43 55 5D 10 20

USER MANUAL iAC Installation Power Amplier
Function Start Channel
Byte
Functions
Bytes Value Bytes End
FIRM
WARE
VERSION
69 41 43 55 01 5D FF 32
AA
VOLUME 69 41 43 55 01 5D 02
00 (= 0 db)
01 (= 1 db)
02 (= 2 db)
03 (= 3 db)
04 (= 4 db)
05 (= 5 db)
06 (= 6 db)
07 (= 7 db)
09 (= 8 db)
09 (= 9 db)
0A (= 10 db)
0B (= 11 db)
0C (= 12 db)
0D (= 13 db)
0E (= 14 db)
0F (= 15 db)
10 (= 16 db)
11 (= 17 db)
12 (= 18 db)
13 (= 19 db)
14 (= 20 db)
15 (= 21 db)
16 (= 22 db)
17 (= 23 db)
18 (= 24 db)
19 (= 25 db)
1A (= 26 db)
1B (= 27 db)
1C (= 28 db)
1D (= 29 db)
1E (= 30 db)
1F (= 31 db)
20 (= 32 db)
21 (= 33 db)
22 (= 34 db)
23 (= 35 db)
24 (= 36 db)
25 (= 37 db)
26 (= 38 db)
27 (= 39 db)
28 (= 40 db)
29 (= 41 db)
2A (= 42 db)
2B (= 43 db)
2C (= 44 db)
2D (= 45 db)
2E (= 46 db)
2F (= 47 db)
30 (= 48 db)
Function Start Channel
Byte
Functions
Bytes Value Bytes End
TREBLE 69 41 43 55 01 5D 06
00 (= -14)
01 (= -12)
02 (= -10)
03 (= -8)
04 (= -6)
05 (= -4)
06 (= -2)
07 (= 0)
0E (= +2)
0D (= +4)
0C (= +6)
0B (= +8)
0A (= +10)
09 (= +12)
08 (= +14)
AA
MIDDLE 69 41 43 55 01 5D 11
00 (= -14)
01 (= -12)
02 (= -10)
03 (= -8)
04 (= -6)
05 (= -4)
06 (= -2)
07 (= 0)
0E (= +2)
0D (= +4)
0C (= +6)
0B (= +8)
0A (= +10)
09 (= +12)
08 (= +14)
BASS 69 41 43 55 02 5D 05
00 (= -14)
01 (= -12)
02 (= -10)
03 (= -8)
04 (= -6)
05 (= -4)
06 (= -2)
07 (= 0)
0E (= +2)
0D (= +4)
0C (= +6)
0B (= +8)
0A (= +10)
09 (= +12)
08 (= +14)
MUTE 69 41 43 55 01 5D 02 3F
SYNC CH1
to CH2 is
ON
69 41 43 55 01 5D 01 01
Operation
08
Receive Sequences
Example:
The following RS232 sequence means that amlier’s Channel 1 volume is set to 10 dB:
69 41 43 55 01 5D 02 0A AA

USER MANUAL iAC Installation Power Amplier
Function Start Channel
Byte
Functions
Bytes Value Bytes End
TREBLE 69 41 43 55 01 5D 06
00 (= -14)
01 (= -12)
02 (= -10)
03 (= -8)
04 (= -6)
05 (= -4)
06 (= -2)
07 (= 0)
0E (= +2)
0D (= +4)
0C (= +6)
0B (= +8)
0A (= +10)
09 (= +12)
08 (= +14)
AA
MIDDLE 69 41 43 55 01 5D 11
00 (= -14)
01 (= -12)
02 (= -10)
03 (= -8)
04 (= -6)
05 (= -4)
06 (= -2)
07 (= 0)
0E (= +2)
0D (= +4)
0C (= +6)
0B (= +8)
0A (= +10)
09 (= +12)
08 (= +14)
BASS 69 41 43 55 02 5D 05
00 (= -14)
01 (= -12)
02 (= -10)
03 (= -8)
04 (= -6)
05 (= -4)
06 (= -2)
07 (= 0)
0E (= +2)
0D (= +4)
0C (= +6)
0B (= +8)
0A (= +10)
09 (= +12)
08 (= +14)
MUTE 69 41 43 55 01 5D 02 3F
SYNC CH1
to CH2 is
ON
69 41 43 55 01 5D 01 01
09
General Specications
iAC Installation Power Amplier
The specications are correct at the time
of printing this manual. For improvement
purposes, all specications for this unit,
including design and appearance, are
subject to change without prior notice.
Technical Specifications iAC 120 iAC 240 iAC 360 iAC 2X240
Output power 1 x 120 W 1 x 240 W 1 x 360 W 1 x 360 W
Power consumption 165 VA 300 VA 410 VA 410 VA
Stand by power consumption 40 VA 40 VA 40 VA 40 VA
Power supply ~ 230 V, 50 Hz
Outputs 1 x Phoenix power output, 1 x Phoenix audio link
Inputs 1 x Balanced Phoenix, 1 x Stereo RCA
Frequency Response 70 Hz - 20 kHz
THD < 0.2 %
S/N ratio 92 dB
Remote control RS-232
Tone control Bass: ±14 dB at 125 Hz, Middle: ±14 dB at 1 kHz, Treble: ±14 dB at 10 kHz
Cooling Convective air
cooling Forced air cooling
Dimensions (H x W x D) mm 438×200×45 438×375 ×45
Weight 5 kg 8 kg 9.4 kg 11.5 kg

10 AMC is a registered trademark of AMC Baltic www.amcpro.eu