AMEO Air Therapy Pure User manual

PURE
AIR THERAPY
Manual

Welcome
The Améo Air Therapy Pure diffuser utilizes cutting-edge
nebulizing technology, which is considered one of the most
direct and therapeutic ways to experience essential oils.
Its nebulizing process delivers pure, undiluted essential oil
in the air by forcing high-pressured air across a small
tube; this process creates a vacuum that pulls the oil from
the bottle and disperses it as an ultra-fine mist.The result
is an exceptional user experience—including a myriad of
therapeutic benefits, enjoyable fragrances, and an improved
air quality—time and time again. Pure’s sleek and ultramodern
look also enhances the expression of any room.
Air Therapy Pure Diffuser
Congratulations on your new Air Therapy diffuser purchase!
Diffusing Améo Essential Oils is one of the best ways to
enjoy their countless benefits for mind, body, and a Rich Soul.

Air Therapy Pure Diffuser
Timer Setting Button (Minutes)
Mist ON Interval Setting Button
(Seconds)
Mist Off Interval Setting Button
(Seconds)
Main Body
LED Light
Power Button
Diffusing Nozzle Outlet
Essential Oil Atomizing Adapter
Essential Oil Bottle
6
2
7
3
8
49
5
Product Overview
Overall View
6
2
7
3
8
4
9
5

6
2
7
3
Timer Setting Button (Minutes)
Mist ON Interval Setting Button
(Seconds)
Mist Off Interval Setting Button
(Seconds)
Power Button
Diffusing Nozzle Outlet
6
27
3
Top View

Operation 1.1
1. Assemble the atomizing
adapter to an open Améo
Essential Oil bottle without
an orifice reducer
Atomizing Adapter Cap Main Unit
Atomizing Adapter
Oil Bottle
2. Mount the assembled oil bottle
onto the main unit; avoid tilting the
bottle to prevent oil leakage
2

Operation 1.2
3. After the bottle is mounted onto
the main unit, connect the power
adapter to the base of the unit and
plug the power adapter into
a power outlet
4. Press the power button to turn the
unit on or off; See “Mode” section for
settings
34

Mode
1. Press the power button to power the unit
- Press once to turn the power and LED light on
- Press a second time to turn the power on and LED light off
- Press a third to power off both the power and the LED light
2. Use “TIMER” button to set how many minutes you want the
unit to run before turning off automatically.
3. Use “ON INT” button to set how many seconds you want the
unit to mist during each interval.
4. Use “OFF INT” button to set how many seconds you want the
unit to take a break from misting during each interval.
Product Name: Air Therapy “Pure” Diffuser
Product Size: 88mm x 132mm
Weight: 400g
Input Voltage: AC 100-240V 50/60Hz
Length of Power Line: 100cm
Height of LED Light Circle: 1.5mm
Material: Aluminum alloy, PP
Air Therapy Pure Diffuser Settings:
This system is designed with 48 possible setting configurations, allowing
you to adjust and tell the diffuser how you’d like to experience your
essential oils.This is key when looking for a therapeutic effect.
Specifications

Maintenance
If you feel that there could be an oil clog, a quick-clean is
recommended; deep-clean is a more thorough method of
cleaning the system and is recommended once every 3
months.
Quick-Clean:
1. Make sure the area is well ventilated by opening nearby windows
2. Pour a small amount of rubbing alcohol into an empty Améo
Essential Oil bottle; fix the bottle to the atomizing adapter
3. Power on the unit and diffuse for about 5 minutes
Deep-Clean:
1.Twist off the essential oil bottle from the atomizing adapter
2.Remove the cap from the atomizing nozzle adapter; the oil
clogs are usually developed inside the straw of the
atomizing nozzle adapter
3.Remove the straw piece in the atomizing nozzle adapter
attachment
4.Completely immerse all dissembled atomizing nozzle
adapter parts in rubbing alcohol; let sit for about 10
minutes to clean the buildup and not harm the diffuser
5.Rinse with warm water and then dry
Clog Prevention/Maintenance Tip:
Run a quick-clean between each oil change or refill

Troubleshooting
No aroma Atomizing adapter clogged
Out of essential oil
Power supply is
not connected
Quick-clean
recommended—diffuse
a small amount of
rubbing alcohol for 5
minutes (must be in
well ventilated area)
Plug in the power
adapter to wall socket
then press power button
Refill or replace
Améo Essential Oil
bottle
Unit not
diffusing
CAUTION: Do not lean or tilt the diffuser during operation.This appliance is
not intended for use by persons (including children) with reduced physical,
sensory, or mental capabilities unless under supervision or been given
instruction concerning the use of this appliance by a person responsible for
their safety. Children should be supervised to ensure that they do not play
with the appliance. Unplug the appliance during filling and cleaning.
Symptom Possible Cause Solution

Precaution
Please read the instructions carefully before using.
Manufacturer accepts no liability for damage caused
by incorrect use of diffuser.
Warnings
& cautions
Action not
allowed
Strictly
prohibited
1. Quick-clean the machine and atomizing adapter between each oil or refill.
2. Shut off the power before changing oils and cleaning.
3. Only use the original power adapter provided by the manufacturer.
4. If you don’t use the device for a long time, shut off and clean unit to prevent clogging.
5. Never use steamed water. Never use corrosive solvents to clean product.
6. Never tilt the unit or parts. Keep unit upright at all times.
7. Keep away from children and pets.
8. Keep power adapter clear of obstructing objects. Never wrap the adapter with
a cloth, paper, etc.
9. Do not use other liquids except for essential oils.
10. Do not place the device close to walls, ceilings, furniture, or other surfaces as
steam could cause oil damage.
11. Quick-clean the device by diffusing rubbing alcohol in a well-ventilated area
for about 5 minutes.
12. Do not inhale essential oil mist at close range to prevent potential risks.
13. Never touch the power adapter with wet hands.
14. Never submerge unit in water.
Table of contents
Popular Accessories manuals by other brands

Pessl Instruments
Pessl Instruments METOS SolAntenna user manual

Braven
Braven BRV-BANK owner's guide

Bosch
Bosch PRS-1AIP1 Installation and user instructions

American Standard
American Standard Acrylux 36" x 36" Shower Kit 3636Y1K.ST Specification sheet

Topcom
Topcom Butler 1000 user guide

TOPPOINT
TOPPOINT LT91130 user manual