manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. American Dynamics
  6. •
  7. Accessories
  8. •
  9. American Dynamics AD2091 User manual

American Dynamics AD2091 User manual

Other manuals for AD2091

2

This manual suits for next models

1

Other American Dynamics Accessories manuals

American Dynamics AD2031 User manual

American Dynamics

American Dynamics AD2031 User manual

American Dynamics AD1422 Manual

American Dynamics

American Dynamics AD1422 Manual

Popular Accessories manuals by other brands

Quincy lab 140AE-1 operating manual

Quincy lab

Quincy lab 140AE-1 operating manual

HomePro ZIR000 user manual

HomePro

HomePro ZIR000 user manual

DOL 20SCR Technical user guide

DOL

DOL 20SCR Technical user guide

RAB Smart Task installation manual

RAB

RAB Smart Task installation manual

Kemppi KMS 300 quick guide

Kemppi

Kemppi KMS 300 quick guide

Stearns 57,500 Series Installation and service instructions

Stearns

Stearns 57,500 Series Installation and service instructions

iGuzzini TWILIGHT COPENAGHEN manual

iGuzzini

iGuzzini TWILIGHT COPENAGHEN manual

Adelaide Annexe & Canvas Avan Deluxe installation guide

Adelaide Annexe & Canvas

Adelaide Annexe & Canvas Avan Deluxe installation guide

OHAUS 5000 instruction manual

OHAUS

OHAUS 5000 instruction manual

HOME8 WLS1300 quick start guide

HOME8

HOME8 WLS1300 quick start guide

MAXBOTIX MaxSonar quick start guide

MAXBOTIX

MAXBOTIX MaxSonar quick start guide

ioSmart iSmart56 Installation and user guide

ioSmart

ioSmart iSmart56 Installation and user guide

Focusrite Scarlett 18i8 user guide

Focusrite

Focusrite Scarlett 18i8 user guide

Velleman ED38105 user manual

Velleman

Velleman ED38105 user manual

JumpSport SkyBounce user manual

JumpSport

JumpSport SkyBounce user manual

Prima-Temp PRIYA Instructions for use

Prima-Temp

Prima-Temp PRIYA Instructions for use

Tefcold BC85I-BC85I W user manual

Tefcold

Tefcold BC85I-BC85I W user manual

Vaisala WMS302 user guide

Vaisala

Vaisala WMS302 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

DATA SHEET
AD2091
Manchester Distributor Accessory
Features That Make a Difference:
Manchester Control Code Generator/Distributor
64 Manchester outputs in four groups of 16
One RS-232 output
Can be used as a code combiner
Diagnostic LEDs
Universal wall, surface, and rack mount
Quick-connect screw terminals for all cable
connections
The AD2091 series Manchester Control Code
Generator/Distributor provides economical distribution of
American Dynamics
®
Manchester code to SpeedDome Ultra
Series Programmable Domes, SpeedDome Optima Series
Domes and compatible receiver/drivers. AD2091 interfaces
with MegaPower 168, 1024, and 3200 matrix switchers/
controllers via the American Dynamics data lines. AD2091
provides up to 64 independent, buffered American Dynamics
Manchester control code outputs in four groups of 16.
Each group is capable of controlling separate blocks of 64
camera sites. Multiple units can be cascaded to provide
control for up to 1024 camera sites. Each output will drive
up to 5000 ft. of cable. A single RS-232 output, with
selectable baud rates, may be used for transmitting code
over suitably equipped devices. AD2091 can also be used
to combine control code from two different matrix systems.
The unit can be mounted in a rack or on a wall surface.
MegaPower 1024 Rear View (AD1024CPU)
MegaPower CPU Rear View (ADMPCPU)
AD Data Lines/COM Ports 1-2 or 3-4*
* Control data is sent via these two BNC connectors to switching bays, code generation devices, and accessories that are part of the matrix switching system.
The number of monitors, cameras, and camera PTZ functions controlled as is follows:
Data Line Monitors Cameras Camera PTZ
1 1-64 1-3200 1-1024
2 65-128 1-3200 1025-2048
3 129-192 1-3200 2049-3072
4 193-256 1-3200 3073-3200
AD2091 can be used to expand an existing MegaPower 168, MegaPower 1024, and MegaPower CPU.
AD Data Lines/COM Ports 1-2
SPECIFICATIONS
Product offerings and specifications are subject to change without notice. Actual products may vary from photos. Not all products include all features. Availability
varies by region; contact your sales representative. Certain product names mentioned herein may be trade names and/or registered trademarks of other companies.
© 2008 Tyco International Ltd. and its respective companies. All rights reserved. AD0115-DS-200804-R01-LT-EN
www.americandynamics.net
AD2091 Series
Model Numbers
AD2091 . . . . . . . . . . . . . . . . . . Manchester Control Code Generator/Distributor,
120 VAC
AD2091-1 . . . . . . . . . . . . . . . . Manchester Control Code Generator/Distributor,
230 VAC
Operational
Dome/Receiver Outputs . . . . . . 64 Manchester outputs, four groups of 16
outputs
Address Range. . . . . . . . . . . . . One to 1024 in blocks of 64 per group
LEDs . . . . . . . . . . . . . . . . . . . . Three (power, HSDL 1 and 2)
Connectors
High Speed Data Line. . . . . . . . BNC, in and out (HSDL 1)
BNC, in and out (HSDL 2)
RS-232...................RJ-45
Manchester Control Code. . . . . Sixteen 12-pin removable screw terminal
Electrical
Supply Voltage
AD2091 . . . . . . . . . . . . . . . . 120 VAC, 50/60 Hz
AD2091-1. . . . . . . . . . . . . . . 230 VAC, 50/60 Hz
Power Consumption. . . . . . . . . Eight watts nominal
Mechanical
Dimensions (H x W x D) . . . . . . 89 x 432 x 203 mm; (3.5 x 17.0 x 8.0 in)
Unit Weight. . . . . . . . . . . . . . . . 3.2 kg (7.0 lbs)
Shipping Weight . . . . . . . . . . . . 4.1 kg (9.0 lbs)
Mounting . . . . . . . . . . . . . . . . . Universal wall, surface, and rack
(19-inch EIA)
Environmental
Operating Temperature. . . . . . . 0° to 40°C (32° to 104°F)
Humidity. . . . . . . . . . . . . . . . . . 98% RH (noncondensing)
Storage Temperature . . . . . . . . -40° to 70°C (-40° to 155°F)
Regulatory
Emissions. . . . . . . . . . . . . . . . . FCC Part 15, Subpart B, Class A
CE: EN55022 Class B
Immunity . . . . . . . . . . . . . . . . . CE: EN50082-1
Safety....................UL2044
cUL: CSA C22.2 No. 1-94
CE: EN60950