Ampetronic C Series User manual

Box Contents
• 1 x C Series Driver including:
• 1 x Loop connectors (2x for dual channel
drivers)
• 1 x DC connector
• 1x Status relay connector (C10/14 only)
• 2 x Input connectors
• 1 x 100V line connector
• 1 x Line out connector
• 2 x 2mm steel 1U rack mount brackets
Also includes:
• 1 x C Series quick start guide
• 1 x Power cable (region specic)
• 1 x Induction Loop Sign
• 4 x self adhesive feet
This symbol is used to alert the user to important operating or maintenance instructions.
The Lightning bolt triangle is used to alert the user to the risk of electric shock.
1. SAFETY
1. It is important to read these instructions, and to follow them.
2. Keep this quick start guide in an accessible place.
3. Clean only with a dry cloth. Cleaning uids may aect the equipment.
4. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
5. Do not install this equipment near any heat sources such as radiators, heating vents or other apparatus
that produces heat.
6. WARNING – THIS APPARATUS MUST BE EARTHED / GROUNDED.
7. Only power cords with the correct power connector may be used to maintain safety. Cables incorporating
the UK 13A fused plug, Schuko with earthing contacts and UL approved “grounding type” are acceptable.
These must be plugged into power outlets which provide a protective earth.
8. C10 and C14 ampliers incorporate a mains voltage switch by the power socket on the rear of the unit.
Ensure this is set accordingly to the local mains supply voltage before connecting. Failure to do so may
damage the unit and would not be covered by warranty.
9. Refer all servicing to qualied personnel. Servicing is required when the apparatus has been damaged in
any way, such as a power supply cord or plug is damaged, liquid has been spilled or objects have fallen
into the apparatus, the apparatus has been exposed to any rain or moisture, does not operate normally
or has been dropped.
10. WARNING – To reduce the risk of re or electric shock, do not expose this apparatus to rain or
moisture. The apparatus shall not be exposed to dripping or splashing and no objects lled with
liquids, such as vases, shall be placed on the apparatus.
11. Warning: Connection to a 100V line system may involve the risk of electric shock and therefore
must be carried out by an instructed or skilled person.
Ampetronic C Series Quick Start Guide Page 1
TO PREVENT ELECTRIC SHOCK DO NOT REMOVE THE
COVER. THERE ARE NO USER SERVICEABLE PARTS
INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL
C Series Quick Start Guide

Dante enabled models have a dedicated RJ45 socket which acts as Input 3.
5. SETTINGS
The C Series drivers have their adjustments set in decibels (dB). A setting of 0dB equates to maximum
current or to maximum input gain. A negative value will reduce the current or input gain accordingly.
From the factory the drivers are provided with the following setting:
4. INPUTS AND OUTPUTS
The driver has two inputs labelled 1 and 2. Each
input can be separately congured to mic or line
signal level using a rear panel push switch. Global
24V phantom power can be enabled to supply
any input set to mic level. Alternatively input 2 can
accept a 100V line using a dedicated 2 pin socket.
Do not use both input 2 sockets at the same
time.
Warning: Connection to a 100V line system
may involve the risk of electric shock and
therefore must be carried out by an instructed
or skilled person.
The driver has either one or two loop outputs
labelled Loop A and Loop B. In order to achieve
correct operation it is recommended the loop and
feed resistance should be between 0.2 and 10Ω (at
DC).
(Screen)
-(Signal cold)
+ (Signal hot)
-
-
+
+
Twisted Pair or Starquad
feed cable, positive and
negative.
Ampetronic C Series Quick Start Guide
Page 2
• Current: -20dB from full output
• Metal Loss Compensation (MLC) OFF
• Input Gain Channel 1 -80.0dB
• Input Gain Channel 2 -80.0dB
• Input Gain Channel 3 -80.0dB (Dante enabled
drivers only)
• Driver Name blank - reports model number
• Phase Shift ON (dual channel drivers)
• Ethernet Parameters Set by DHCP
Figure 1: Input connections Figure 2: Output connections
Do not run input and output cables close together
Home / power
button
Navigate (rotate)
and select (press)
control
128 x 160 pixel
colour display
Status LED:
Solid Green = normal operation
Flashing Green = sleep mode
Flashing Amber = standby
Flashing Red = error
Fast Flashing Amber = rmware update
Figure 3: Front
panel display and
control
2. TOOLS AND EQUIPMENT
Small hand tools including a wire stripper, small at blade and posi screwdrivers will be required.
A magnetic eld strength meter, Loopworks Measure App & R1 Reciever, or at minimum an induction loop
receiver is vital to check that the loop system is providing the desired level of performance.
3. FIRMWARE
It always recommended to ensure your amplier is on the latest rmware before installation.
On the front menu go to Driver Status > About and check the version number against the latest update
available at www.ampetronic.com/rmware-upgrades

Ampetronic C Series Quick Start Guide Page 3
7. NETWORK CONNECTION (OPTION)
Where tted C Series drivers feature a web interface that can be viewed in a web browser. Although
optimised for the Chrome browser, any browser can be used to view the interface. The web interface is
used to monitor and adjust the driver. You will be asked for the User Name and Password for the driver as a
deterrent to unauthorised parties. These values are case sensitive and need to be entered once per session
to access the driver.
8. TROUBLESHOOTING
The driver performs a series of diagnostics on start-up as well as constant fault monitoring once active.
Errors will show on the front screen, in the status menu and on the web interface of network enabled drivers.
Note: Some errors relate to the loop circuit rather than the amplier itself and indicate further troubleshooting
of the installation is required.
For a list of all error messages and troubleshooting see the full C-Series handbook.
If assistance is required, contact Ampetronic Support Team with a note of the exact error text.
9. ASSOCIATED DOCUMENTS
• UP19801 – C Series Installation Handbook & User Guide
• UP39801 – C Series Datasheet
• UP39808 – C Series Protocol Guide
Associate documents are available as a download from www.ampetronic.com, in Loopworks Learn or can be
User Name = superadmin, netadmin, audioadmin
Passwords = ampetronic (default)
For security purposes, it is recommended that the default password is changed to
a strong password at the earliest possible opportunity. This can be done using the
web interface.
Four levels of access are available:
1. superadmin - allows access to all settings
2. netadmin - access the network settings page
only
3. audioadmin - access the audio settings pages
only
4. no login - allows access to status page
6. ADDITIONAL FEATURES
• Home screen timeout – if no action is taken in a mode screen after 30s the home screen is displayed.
For a value screen the timeout is 60s.
• Sleep mode – After a 30 minute period of user or audio inactivity the driver turns on the ‘Loop outputs
disabled’ test signal and turns o the screen to save power. The Status led ashes green to indicate this.
Any user activity or presence of audio signal brings the driver out of sleep. The inactivity time can be
changed via the website (where network option tted)
• Lock screen – A long press on the home button brings up the lock menu. This gives access to standby,
re-start (same as in settings menu) & lock. Selecting lock makes the user controls inactive. Any user
input results in a padlock being displayed. To unlock the unit press the home button six times. Unlock
instructions are shown briey when lock is selected.
• Standby – This is a user imposed sleep. Only user activity (not audio signal) brings the driver out of
standby.

UP19802 -5 Contents Copyright © Ampetronic Ltd 2021. All rights reserved.
10. WARRANTY
This product carries a ve year parts and labour warranty from date of shipment from Ampetronic. To qualify
for the ve year warranty, the product must be registered at www.ampetronic.com (products/warranty),
without which the warranty will be valid for two years only.
The warranty could be invalidated if the instructions in this handbook are not followed correctly, or if the unit
is misused in any way.
11. DECLARATION OF CONFORMITY
Hereby, Ampetronic declares that the radio equipment type Ampetronic Induction Loop Driver C5-1, C5-2,
C7-1, C7-2, C10-1, C10-2, C14-2, including network (N) & DANTE (D) variants, are in compliance with
Directives:
2014 / 53 / EU Radio Equipment Directive and its amending directives
2014 / 35 / EU The Low Voltage Directive and its amending directives
2014 / 30 / EU The Electromagnetic Compatibility Directive and its amending directives
2011 / 65 / EU The RoHS Directive and its amending directives
and Statutory Instruments:
2017 No. 1206 Radio Equipment Regulations and its amending directives
2016 No. 1101 Electrical Equipment (Safety) Regulations and its amending directives
2016 No. 1091 Electromagnetic Compatibility Regulations and its amending directives
2012 No. 3032 RoHS in Electrical and Electronic Equipment Regulations and its amending
directives
The full text of the EU & UK declaration of conformity is available at the following internet address:
www.ampetronic.com/declarationofconformity
CAUTION: Changes or modications not expressly approved by Ampetronic or an authorised
partner could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to
radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at their own expense.
Ampetronic C Series Quick Start Guide
Page 4
This manual suits for next models
19
Table of contents
Other Ampetronic Conference System manuals