Ampfibian AMPFIBIAN RV-PLUS User manual

Suitable for model: AMPFIBIAN RV-PLUS
ADAPT TO YOUR
SURROUNDINGS [email protected]
www.ampfibian.com.au
Freecall: 1800-FIBIAN
(1800 342-426)
1791-INSTRUCT-PLUS-B
Every Ampfibian product is thoroughly inspected and tested before leaving our
factory. Ampfibian Pty. Ltd. limits this warranty against defective workmanship
and faulty materials under normal use for twentyfour (24) months from date of
purchase (proof of date of purchase must be provided) and undertakes at its
option to repair or replace each product or part thereof on condition that:
•The product has not been subject to misuse, neglect, accidents or alterations;
• The unit has been used and maintained as per the instructions.
Ampfibian Pty. Ltd. is not liable for any consequential damage to either people,
work or facilities from using the Ampfibian.
Please ensure Ampfibian is actually faulty before returning it, by testing it on a
different power circuit and with a different appliance. Please see the “Return &
Refund Policy” page on our website or contact us for details. All shipping costs
are the responsibility of the customer.
Please staple your purchase receipt (or a copy) to this document. You will be
asked to provide a filled-out copy of this form and proof-of-purchase in the
event of a warranty claim.
DATE OF PURCHASE:
PURCHASED FROM:
PURCHASER’S NAME:
CONTACT INFORMATION:
LIKE US ON FACEBOOK!
TM
No.
DESCRIPTION
1 LID
2 CORD SEAL (LID)
3 HOUSING SEAL
4 15A SOCKET WITH LIGHT
5 RCD/MCB*
6 CORD SEAL (BODY)
7 LID LATCHES
8 DEVICE LEAD (NOT SUPPLIED)
*) RCD = Residual Current Device
MCB = Miniature Circuit Breaker
9 PLUG & FLY-LEAD
10 TEST PUSH BUTTON
11 RCD/MCB TOGGLE SWITCH
12 PADLOCK ATTACHMENT
USING THE RV-PLUS:
1. With nothing plugged in, connect
the RV-PLUS’s plug (9) directly into power
supply (wall) socket and switch power
supply ON.
2. Switch RV-PLUS ON (11). If unit trips,
unplug it and contact us. DO NOT USE or
continue to next step.
3. Press test button labelled “T” (10). If
switch (11) trips OFF continue to step 4.
If switch (11) DOES NOT trip when test
button pressed, unplug RV-PLUS and
contact us. DO NOT use RV-PLUS or
continue to step 4.
4. Connect device lead (8) to RV-PLUS
socket. Avoid any strain on the lead.
5. Connect RV-PLUS lead (8) to
operating device (caravan, RV, etc.).
6. Switch RV-PLUS to ON position (11).
LID (1) MUST BE LATCHED CLOSED
BEFORE USE. INSPECT SEALS (2,3,6) FOR
DAMAGE AND/OR OBSTRUCTION. DO NOT
USE IF LID, SEALS OR LATCHES (7) ARE
DAMAGED OR INOPERABLE.
IF RV-PLUS TRIPS IN SERVICE:
First rule out that the RV-PLUS is at fault by
performing the above test procedure. The
RV-PLUS will trip due to overload or an earth
leakage fault. If you are unsure of the cause,
or you believe there is an earth leakage fault,
turn off all power and contact a licensed
electrician. If you believe there is an
overload, switch off or unplug some of the
appliances and reset the RV-PLUS.
Electricity can be dangerous! RCDs (Residual
Current Devices) are not a substitute for
basic electrical safety precautions. RCDs are
additional protection and will not prevent
shock, but will minimise the effect. Do not
use this device if it fails to operate correctly
in accordance with these instructions.
The RV-PLUS is rated 240 Volts with a
maximum current rating of 10 Amperes (A).
Do not try to open or repair the RV-PLUS
yourself. No user-serviceable parts are
inside. Test RV-PLUS before each use.
This device will only protect against faults to
earth through the body, but not against
active to neutral faults.
This device must be connected DIRECTLY to
an outlet socket. It must not be connected
via cord extension sets.
OPERATING TEMPERATURE 2˚C TO 40˚C.
Wet seals will freeze and will not recover
their shape until thawed. Do not open frozen
unit until thawed. Opening frozen unit may
result in damage to seals.
DO NOT EXPOSE TO PETROL, OIL, SOLVENTS,
POOL CHEMICALS, ETC.!
DO NOT USE IN HAZARDOUS LOCATIONS!
DO NOT USE IF DAMAGED!
DO NOT DISASSEMBLE!
INGRESS PROTECTED TO IP-55.
DO NOT DROP OR IMMERSE IN WATER!
REMOVE CONDENSATION / MOISTURE WITH A
SOFT ABSORBENT CLOTH.
ONLY CONNECT TO POWER IF UNIT IS
COMPLETELY DRY INSIDE.
TURN OFF POWER SUPPLY BEFORE HANDLING
CONNECTIONS IN WET CONDITIONS!
STORE IN A DRY PLACE OUT OF
DIRECT SUNLIGHT.
ENSURE THERE IS NO GAP VISIBLE THROUGH
CORD SEALS WHEN CLOSED! IF REQUIRED,
LEAVE LID OPEN UNTIL CORD SEALS HAVE
FULLY RECOVERED.
THIS PRODUCT IS NOT INTENDED FOR
PERMANENT INSTALLATION. DO NOT BURY!
SUITABLE FOR ORDINARY AND HEAVY-DUTY
EXTENSION LEADS TO 12mm DIAMETER.
TO BE USED WITH 10A (2400W)
MAXIMUM LOAD.
ON
OFF
Please keep warranty information and instructions with you.
Only send your warranty information to Ampfibian in case of a warranty claim.
INSTRUCTIONS
RCD/MCB may vary from illustration.
All RCD/MCBs have an up/down
toggle switch where UP is ON; and a
test push-button marked “T”.

AMPFIBIAN PRODUCT RANGE
MODEL
Product
Standards
Approval
AS/NZS 3190:2011“Approval and test specification – Residual current devices (current-operated earth-leakage devices)”
-NA- AS/NZS 3001:2008/Amdt 1:2012
“Electrical Installations – Portable structures and vehicles including their site supplies”
Device Class L-Class
Domestic
H-Class
General Industrial
Impact
Rating IK-08
LOAD
Load Socket 15A Single Phase Socket (three flat pins)
Ingress
Protection IP-44 IP-33 IP-55
Phases Single Phase Three Phase
Max. Load 10A 15A 10A 15A
SUPPLY
Max. Supply 10A 15A 20A 32A/40A/50A 10A/20A 20A 32A/40A/50A
Supply Lead
Plug Top Three Flat Pins Three Round Pins Five Round Pins
Ingress
Protection -NA- IP-56 Collared
TP-20 TP-32sP-15 sP-20 TP-10sP-32
RCD MCB
RESIDUAL CURRENT DEVICE
Immediately cuts the power if it detects a difference between incoming
versus outgoing current
MINIATURE CIRCUIT BREAKER
Cuts the power in case of an overload or short circuit
L-CLASS H-CLASS
A single phase portable RCD primarily intended for household use A portable RCD intended for general industrial use
INGRESS PROTECTION Protection against intrusion of solid objects and liquids
IP_1 IP_2 IP_3 IP_4 IP_5
Protection against vertical
falling water drops
Protection against vertical
falling water drops up to
15° from the vertical
Protection against spraying
water (rain) at an angle up
to 60° from vertical
Protection against splashing
water from any direction
(360°)
Protection against water
jets from any direction
(360°)
IP1_ IP2_ IP3_ IP4_ IP5_
Protection for the back of
the hand against access to
hazardous parts and objects
larger than 50mm
Protection for fingers
against access to hazardous
parts, and objects larger
than 12.5mm
Protection for persons hold-
ing tools or wires (larger
than 2.5mm diameter)
Protection for persons hold-
ing tools or wires (larger
than 1mm diameter)
Protection against entry of
dust in sufficient quantity
to interfere with equipment
IMPACT PROTECTION Resistance to mechanical impacts
IK01 IK02 IK03 IK04 IK05
0.15 Joules impact energy
Drop of 200g object from
7.5cm height
0.2 Joules impact energy
Drop of 200g object from
10cm height
0.2 Joules impact energy
Drop of 200g object from
10cm height
0.5 Joules impact energy
Drop of 200g object from
25cm height
0.7 Joules impact energy
Drop of 200g object from
35cm height
IK06 IK07 IK08
1.0 Joules impact energy
Drop of 500g object from
20cm height
2.0 Joules impact energy
Drop of 500g object from
40cm height
5.0 Joules impact energy
Drop of 1.7kg object from
29.5cm height
COMMON INSTRUCT BACK-L
*
*) MINI-BLU available exclusively in NZ.
Popular Adapter manuals by other brands

Devolo
Devolo MicroLink dLAN ADSL Modem manual

WePresent
WePresent SharePod WHE-100 user manual

Lightolier
Lightolier LytespanTrack system Instructions for maintenance reference

TRUlink
TRUlink 29598 user guide

TP-Link
TP-Link Archer T2UB Nano Quick installation guide

Nexxt
Nexxt Nano Lynx Quick installation guide