Ampronix AMVX1508 User manual

AUTO - SCANNING WITH DIGITAL CONTROL
LCD COLOR MEDICAL MONITOR
AMVX1508
OperationManual
Forfuturereference, recordtheserial numberofyour display
monitorin thespace below:
SerialNumber
Theserial numberis locatedon theback ofthe monitor


backof themonitor
Ampronix 2007
Allothertrademarksarethepropertyoftheirreferenceowners.
This document is subject to change without notice.
Ampronixprovidesthisinformationasreferenceonly.Referencetoothervendor’s
productsdoesnotimplyanyrecommendation or endorsement.
Revision Control
GNINRAW
fosresuehtmrofniotdesusi"GNINRAW"eltitehT ro,htaed,yrujniehttcilfnidluoctahtsesuacelbissop .stne
itapehtotegamadytreporp
NOITUAC
fosresuehtmrofniotdesusi"NOITUAC"eltitehT hguohtlastneitapehttcilfnidluoctahtsesuacelbissop .sht
aedesuacothguoneerevestonthgimti
ETON
smetifosresuehtmrofniotdesusi"ETON"eltitehT ,noitallatsnifosmretniecnatropmifoerataht hguohtlatnemp
iuqEehtfoecnanetniamro,noitarepo ehtotmrahylidobehttcilfnitonseoderuliafeht .stneitap
etaDnoitpircseD
70812110.veRrebmuntnemucoD
AMVX1508 1

TABLE OF CONTENTS
ProductDescriptionandIntendedUse......................................................
WarningsandCautions................................................................................
SymbolExplanations....................................................................................
EUDeclarationofConformityforMedicalApplications...........................
SafetyPrecaution.........................................................................................
CleaningYourMonitor..................................................................................
PowerManagementFunction....................................................................
PresetModes..............................................................................................
DDC.............................................................................................................
Installation....................................................................................................
ConnectingthePowerCord......................................................................
Component/ RGB/RGBSConnectionInstruction.................................
UserControls..............................................................................................
OSDScreenBasicSection.......................................................................
OSDFunctionDescription.........................................................................
Troubleshooting..........................................................................................
Specificationof(AMVX1508)..................................................................
Classification..............................................................................................
ElectromagneticCompatibility..................................................................
DimensionDrawing(mm)..........................................................................
Connectors..................................................................................................
3
4
7
8
9
9
10
11
12
12
13
14
15
16
19
20
21
22
23
26
27
2User’s Guide

Product Description and Intended Use
Please check the following items are present when you unpack the box, and save the
packing materials in case you will need to ship or transport the monitor in future.
•AMVX1508LCDMonitorandtwovideocable(1)DVI-Ato HD15 VGA cable*
(1)DVI-Dcable*(1) BNC to RCA adapter (1) DVI-A to BNC Female cable*
•AC Power cord **
•AC-Adapter
•CompositeVideoBNCJackCableandSuperVideoCable
•UserManual
*Might be optional item, check with local representative
**Might vary pending on region standard
CAUTION
Manufacturer:AultKorea
ModelNo : MW160KA1203F52
*
*
*
AMVX1508 3

Warnings and Cautions
Please read this manual and follow its instructions carefully. The words warning,
caution,and note carry special meaningsand should be carefully reviewed:
Warranty is void if any of these warnings are disregarded.
Ampronix accepts full responsibility for the effects on safety, reliability, and
performanceoftheequipment only if:
•Re-adjustments, modifications, and/or repairs are carried out exclusively
byAmpronix.
• The electrical installation of the relevant operating room complies with the
applicableIECandCE requirements.
Warning Federal law (United States of America) restricts this
device to use by, or on order of a physician.
TheAmpronixAMVX1508monitorhasbeen tested under UL60601-1 standardand
ULlisted for Medical application.
Ampronixreserves the right to makeimprovements in the product(s) described
herein. Product(s), therefore, may not agree in detail to the published design or
specifications.All specifications are subject to change without notice. Please
contactAmpronixdirectly or phone yourlocalAmpronix salesrepresentative or agent
forinformationon changes and new products.
ebyamnaicisyhprotneitapehtfoytefaslanosrepehTgninraW nitluserdluocnoitamrofnisihtgnidragersiD.devlovni .naicisyhprotneitapehtotyrujni
ebtsumsnoituacerproserudecorpecivreslaicepSnoituaC .tnemurtsniehtgnigama
ddiovaotdewollof
etoN tnatropmiroreisaeecnanetniamekamotnoitamrofnilaicepS .raelceromnoitamrofni
ehttrela
otdednetnisielgnairtanihtiwkramnoitamalcxenA ecnanetniamdnagnitarepotnatropmifoecneserpehtotresu .tcudorpehtgniynapmoccaerutaretilehtnisnoitcurtsni
ehtfonrawotdednetnisielgnairtanihtiwtlobgninthgilA deziroh
tuaotecivresllarefeR.egatlovsuodrazahfoecneserp .lennosrep
RESUEHTOTYRUJNISUOIRESLAITNETOPDIOVAOTgninra
W,ECIVEDSIHTOTEGAMADRO/DNATNEITAPEHTDNA :TSUMRESUEHT
4User’s Guide

Warnings
1. Read the operating manual thoroughly and be familiar with its contents prior to using
this equipment.
2. Carefully unpack the unit and check if any damage occurred during shipment.
3. Should any solid object or liquid fall into the panel, unplug the unit and have it checked
by qualified personnel before operating it any further.
4. Uplug the unit if it is not to be used for an extended period of time. To disconnect the
cord, pull it out by the plug. Never pull the cord itself.
5. Be a qualified physician, having complete knowledge of the use of this equipment.
6. Test this equipment prior to a medical procedure. This monitor was fully tested at the
factory before shipment.
7. Avoid removing covers on control unit to avoid electric shock.
8. Attempt no internal repairs or adjustments not specifically detailed in this operating
manual.
9. Pay close attention to the care, cleaning instructions in this manual. A deviation may
cause damage (refer to the Cleaning section).
10. DO NOT STERILIZE MONITOR.
11. Read the entire instruction manual before assembling or connecting the camera.
12. Do not place the monitor or any other heavy object on the power cord. Damage to the
cable can cause fire or electirc shock.
13. Monitor with power supply is suitable for use in patient environment.
14. DO NOT stack more than 8 boxes high
This equipment has been tested and found to comply with the limits for medical devices
in IEC 601-1-2:2003. These limits are designed to provide reasonable protection against
harmful interference in a typical medical installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to
other devices in the vicinity. However, there is no guarantee that interference will not occur
in a particular installation. If this equipment does cause harmful interference to other
devices, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving device.
- Increase the separation between the equipment.
- Connect the equipment into an outlet on a circuit different from that to which the other
device(s) are connected.
- Consult the manufacturer or field service technician for help.
NOTICES TO USER
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
FCCWARNING
This equipement generates or uses radio frequency energy. Changes or modifications to
this equipment may cause harmful interference unless the modifications are expressly
approved in the instruction manual. The user could lose the authority to operate this
equipment if an unauthorized change or modification is made.
AMVX1508 5

Cautions
1. The AC Adapter must be plugged into a Grounded power outlet.
2. Use only the proprietary AMVX1508 power supply for the AMVX1508 monitor. Make a
proper connection by ensuring that the shrink tubing completely secures the connection
between the DC power cord and the extension cord.
3. Turn power off when unit is not in use.
4. Never operate the unit right after having transported from a cold location directly to a
warm location.
5. Do not expose the monitor to moisture or directly apply liquid cleaners directly to the
screen. Spray the cleaning solution into a soft cloth and clean gently.
6. Handle the monitor with care. Do not strike or scratch the screen.
7. Do not block the monitor cooling vents. The monitor is cooled by natural convection
and has no fan.
8. Do not force the monitor past 28 degrees of vertical when adjusting the screen
position. (For monitors equipped with stands only.)
9. Remove the power module and connection when transporting the unit.
10. Save the original carton and associated packing material. They will be useful should
you have to transport or ship the unit.
11. Allow adequate air circulation to prevent internal heat buildup.
12. Do not place the unit on surfaces (rugs, blankets, etc.) or near materials (curtains,
draperies) that may block the ventilation slots.
13. Do not install the unit near sunlight, excessive dust, mechanical vibration or shock.
14. The unit is designed for operation in a horizontal position. Never operate the unit in a
vertical position.
15. Keep the unit away from equipment with strong magnets (i.e. a large loudspeaker.)
16. Do not expose the monitor to moisture or excessive dust.
17. Equipment with SIP/SOP connectors should either comply with IEC 60601-1 and/or
IEC 60601-1-1 harmonized national standard or the combination should be evaluated.
Do not touch the patient with signal input or output connectors.
18. Use only a hospital grade power supply cord.
19. This equipment generates, uses, and can radiate radio frequency energy. If not
installed correctly and or not used in accordance with these instructions, it may cause
harmful interference with other devices. This may be determined by turning the
equipment off and on. The user is encouraged to try to correct the interference through
one or more of the following measures:
• Reorient or relocate the receiving device.
• Increase the separation distance between the equipment.
• Connect the equipment to an outlet on a circuit different from that to which the other
device(s) are connected.
• Consult the manufacturer or field service technican for help.
20. Grounding reliability can only be achieved when the equipment is connected to an
equipment receptacle labeled “Hospital Only” or “Hospital Grade.”
Note To connect to an international power supply, use a an attachment plug
appropriate for the power outlet.
Note Refer to the “Electromagnetic Compatibility” (EMC) section of this manual to
ensure EMC. The AMVX1508 must be installed and operated according to the EMC
information provided in this manual.
6User’s Guide

Symbol Definitions AMVX1508 7

EU Declaration of Conformity for MedicalApplications
ADeclarationof Conformity has been filed for thisproduct.Asampleof
thisdocumentmay befound in theaddendum whichaccompaniedthis
manual. Fora copy of the Declarationof Conformitydocument, please
contactAmpronixand request forAMVX1508 DOC.
Prepare for Unpack
Beforeyou unpackyour monitor, preparea suitableworkspace.You
needa stable and level surfacenear agrounded walloutlet inan area
whichisrelatively freeof glare fromsunlight orother sources ofbright
light.Themonitor is cooledby natural convection(ithas nofan).
Foroptimum performance, donot blockthe cooling vents.
Whileunpackingthe monitor,inspect it and otherpackage contentsfor
shippingdamage that could cause afire orshock hazard.Immediately
reportany shipping damage to thecarrier ortransportation company
andcontact customer service for monitorin thefuture orin caseof
return.
Afteryouunpackthe monitor,make surethefollowing itemsare in-
cluded
• Monitor with video cable
• AC adapter with cable
CAUTION:ACAdaptermustbe plugged into Grounded apower outlet
CAUTION :AC adapter
Manufacturer: Ault korea
Model No: MW160KA1203F52
• This operations manual
Note: Your system provider may offer alternative cords or cables
dependingonthe installationrequirementand localgeography issues.
8User’s Guide

SAFETY PRECAUTION
· Avoid placing the monitor, or any other heavy object, on the power cord to prevent
fire or electrical shock from damage to the power cord.
· Donot expose the monitor torain,excessivemoisture, or dust to avoidfireorshock
hazard.
· Donot cover theslotsoropeningsof the monitor forproperheat dissipation.Always
putthemonitor in a place where there is adequate ventilation.
· Avoid placing the monitor against a bright background or where sunlight or other
light sources may reflect on the area of the monitor. Place the monitor just below
eyelevel.
· Handlewith care when transporting the monitor.
· Refrain from giving the shock or scratch to the screen, as screen is fragile.
CLEANING YOUR MONITOR
No specific liquid or chemical necessary when cleaning this LCD monitor
However,we suggest to clean the monitor withnon-abrasivecloths and cleaning
solutions used in hospitals to clean similar equipment. We recommend using 70%
Isopropylalcohol for the screen surface and warm water anda mild detergent for all
othersurfaces. Other acceptable cleaningagents are listed below:
• 70% isopropyl alcohol
• 6% aqueous ammonia
• Cidex (2.4% glutaraldehyde solution)
• Sodium Hypochlorite (bleach) 10%
• “Green soap” USP
• 0.5% Chlorhexidine in 70% isopropyl alcohol
• Ovation
• Formula 409
• Fantastic
• Wex Cide
To clean the screen, do not spray liquid cleaners directly on to the unit. Stand away
Form the monitor and spray cleaning solution onto a cloth. Without applying exces-
sivepressure, clean the screenwith the slightly dampened rag.
AMVX1508 9

POWER MANAGEMENT FUNCTION
Themonitorisequipped withthepowermanagementfunctionwhichautomaticallyreduce
thepowerconsumptionwhennotin use in three power level modes.
•Stand-by Mode
The monitor goes into stand-by mode when the horizontal sync signal is off for
about10 seconds. In this mode, the screengoesoffandthe power LED blinks for 1
seconds On and 1 second Off. The screen is displayed after the horizontal sync
signal is restored.
•Suspend Mode
The monitor goes into suspend mode when the vertical sync signal is off for about
10seconds.The power consumption during this is less than8W.In this mode, the
screengoesoffandthe power LED blinks for 1 seconds On and 1 second Off.The
screen is displayed after the vertical sync signal is restored.
•Off Mode
Themonitor goesintopower-offmode whenthevertical and horizontalsyncsignals
are off for about 10 seconds. In this mode, the screen goes off and the power LED
blinksfor 1 seconds On and 1 second Off. The screenisdisplayedafterthevertical
and horizontal sync signals are restored.
Power Management System
TheAMVX1508MedicalMonitorpower management proposal. Provides fourphases
of power-saving modes by detecting the horizontal sync signal as shown in the table
below.
When the monitor is power saving mode or detects an incorrect timing, the screen will
be blank and power LED indicator will blink.
edoMrewoPtupnICD )ylnorotinom( rewoptupnICA )retpadaCA.lcnI( sutatSDEL
nO.xamW83.xamW06neerGydaetS
ybdnatS.xamW0
.6.xamW5.7neerGgniknilB
dnepuS.xamW0.6.xamW5.7neerGgniknilB
ffO.xamW0.6.xamW5.7neerGgniknilB
10 User’s Guide

PRESET MODES
edoM)VxH(noituloseR)zHK(.qerF.H)zH(.qerF.V
1053x0465.1307
2053x0469.7358
3004x0469.7358
4053x0275.1307
5004x0279.7358
6084x0465
.1306
7084x0469.7327
8084x0465.7357
9084x0463.3458
01006x0081.5365
11006x0089.7306
21006x0081.8427
31006x0089.6457
41006x0087.3558
51867
x42015.5334
61867x42014.8406
71867x42015.6507
81867x42010657
91867x42017.8658
02468x25115.7657
12069x08210606
224201x08219.3606
32420
1x08219757
*Best resolution 1024 x 768, 60 Hz
AMVX1508 11

DDC
To make your installation easier, the monitor is able to Plug and Play with your system
if your system also supports DDC protocol. The DDC (Display Data Channel) is a
communicationprotocolthrough whichthe monitorautomaticallyinformsthehostsystem
aboutits capabilities,forexample,supported resolutionsandcorresponding timing. The
monitorsupports DDC1 and DDC2Bstandard.
INSTALLATION
To install the monitor to your host system, please follow the steps as given below:
Steps
1. Usethe supplied video cable (DVI, DVI-A->VGA, S-Video, C-Video, DVI-A->BNC
Female) then connect to the host system accordingly.
2. ConnecttheDCpower to the DC power connector on the monitor.
3. Connectone endofACpowercord intotheACAdapterandtheotherend toACpower
outlet.
4. Then turn the host system on and then the monitor.
5. If themonitor still does notfunction properly, please refer to the troubleshooting
section to diagnose the problem.
POWER DVI-I
(VGA/COMPONENT) S-V C-V TOUCHSCREEN
(OPTION)
12 User’s Guide

CONNECTING the POWER CORD
* Check first to make sure that the power cord you use is the correct type required for
yourarea.
* Thismonitorhas an universalAC adapter that allows operation in eitherAC 100 - 240
Vacvoltage area. No user-adjustment is required.
* Plug one end of the power cord to the AC adapter, plug another end to a properAC
outlet.
The cord set should have the appropriate safety approvals for the country in which the
equipmentwillbeinstalled and marked HAR.
For 120 volt Applications, use only UL Listed deachable power cord with NEMA
configuration 5-15P type (parallel blades) plug cap. For 240 volt applications use only
ULListed Detachable power supply cord with NEMA configuration 6-15P type (tandem
blades)plugcap.
AMVX1508 13

Component / RGB / RGBS CONNECTION INSTRUCTION
For Component (YPbPr) Connection
1. Connect DVI-A to BNC Female cable onto the monitor via DVI port.
2. Connect BNC (YPbPr) cables from the video source to the DVI-A to BNC Female
cable. Red (Pr) connect to Red BNC, Green (Y) connect to Green BNC, and
Blue (Pb)connect to Blue BNC.
3.Thevideosource should have components output on the video equipment for
components (YPbPr) video out.
4.To select component mode in the monitor, push “Select” button on the monitor
until it reach “Component / RGB” input or can select in the OSD by Push
“UpArrow” button then the OSD Menu will pop-up, Push “UpArrow” or
“DownArrow” button to select “Input Source Select” then push select button to
enter Input Source Select Menu, Push “UpArrow” or “DownArrow” button to
select “Component / RGB” then push select button.
For RGB Connection
1. Connect DVI-A to BNC Female cable onto the monitor via DVI port.
2. Connect BNC (RGB) cables from the video source to the DVI-A to BNC Female
cable. Red (R) connect to Red BNC, Green (G) connect to Green BNC, and
Blue (B)connect to Blue BNC.
3.Thevideosourceshouldhave RGB output on the video equipment for RGB video
out.
4. To select RGB mode in the monitor, push “Select” button on the monitor until it
reach “Component / RGB” input or can select in the OSD by Push “UpArrow”
button then the OSD Menu will pop-up, Push “UpArrow” or “DownArrow” button
to select “Input Source Select” then push select button to enter Input Source
Select Menu, Push “UpArrow” or “DownArrow” button to select “Component/RGB”
then push select button.
For RGBSync Connection
1. Connect DVI-A to BNC Female cable onto the monitor via DVI port.
2. Connect BNC (RGB) cables from the video source to the DVI-A to BNC Female
cable. Red (R) connect to Red BNC, Green (G) connect to Green BNC,
Blue (B)connect to Blue BNC and SYNC (V) connect to White BNC.
3.Thevideo source should have RGBSync output on thevideoequipment for
RGBS video out.
4. To select RGBSync mode in the monitor, push “Select” button on the monitor until
it reach “Component / RGB” input or can select in the OSD by Push “UpArrow”
button then the OSD Menu will pop-up, Push “UpArrow” or “DownArrow” button to
select “Input Source Select” then push select button to enter Input Source Select
Menu, Push “UpArrow” or “DownArrow” button to select “Component / RGB” then
push select button.
14 User’s Guide

USER CONTROLS
Front Panel Controls
1. Power LED : Lights up to indicate the power is turned ON.
2. Power Switch : To turn ON or OFF the power.
3. + : To increase the value of the parameter in the OSD you have selected for
adjustment.
: To increase the contrast directly when OSD menu is not activated.
: To move upward in the OSD menu.
: Execute a function of selected item.
4. - : To decrease the value of the parameter in the OSD you have selected for
adjustment.
: To decrease the brightness directly when OSD menu is not activated.
: To move downward in the OSD menu.
5. Menu : To enter OSD.
6. Select : Enter a sub menu or select a menu item.
If video display option is adopted, switch PC display to Video display and
vice versa by one touch when OSD menu is not activated.
7.Auto Button : One touch Auto adjust or Exit OSD menu.
Standard OSD Operation
1. Press “Menu” button to activate the OSD.
2. Use “+” or “-” button to move through the menu.
Theparameterwill be highlighted when selected.
3. Then use “Select” button to enter the sub menu.
Choice the sub menu different options with “Select” button.
3. Then use “+” or “-” to increase or decrease the value of the parameter, or make
selectionbetweendifferentoptions.
4. To quit the OSD screen at any time during the operation, press “Auto” button.
If no keys are pressed for a time period, the OSD automatically disappears.
AMVX1508 15

OSD Screen Basic Section
#1 Only available when you using the (VGA) or (Component / RGB) connection
* Follow the Standard OSD Operation.Use “-” or “+” button to adjust
16 User’s Guide
Brightness / Contrast *Frequency / Phase * (#1)
Position *OSD Control *
Color Temperature *Utilities *

OSD Screen Basic Section AMVX1508 17
Hue and Saturation * (#2) Sharpness * (#2)
Zoom *Input Source Select *
Scale Mode * (#3) Scale Mode * (#4)
#2 Only available when you using the (C-Video) or (S-Video) connection
#3 Only available when you using the (VGA) or (DVI) connection
#4 Only available when you using the (C-Video), (S-Video) or (Component/RGB) connection
* Follow the Standard OSD Operation.Use “-” or “+” button to adjust

OSD Screen Basic Section
18 User’s Guide
AutoAdjust / Factory Reset * (#5) Factory Reset * (#6)
Information (#7)
#5 Only available when you using the (VGA) connection
#6 Only available when you using the (DVI), (C-Video), (S-Video) or (Component/RGB)
connection
#7 Different video input may have different information
* Follow the Standard OSD Operation.Use “-” or “+” button to adjust
Table of contents
Other Ampronix Monitor manuals