ANDERSON-NEGELE NSL-F series User manual

Continuous Level Sensor
oNSL-F-00
oNSL-F-01
oNSL-F-02
OPERATING MANUAL
SENSORS FOR FOOD AND BIOPHARMA.
NSL-F
30002 / 1.1 / 2015-04-16 / MU / EU

NSL-F Series Operating Manual 2
Table of contents
Table of contents .......................................................................................................2
1Conformity with standards ...............................................................................3
2Safety instructions...........................................................................................3
3Special features/advantages .............................................................................4
4Options/accessories .........................................................................................4
5Installation and connection...............................................................................4
6Dimensions ...................................................................................................14
7Wiring diagram.............................................................................................. 17
8Repair and maintenance................................................................................. 17
9Technical data ............................................................................................... 17
Declaration of conformity .........................................................................................16

NSL-F Series Operating Manual 3
Application/intended use
Continuous level monitoring in metallic vessels up to 3m in height
Ideal for highly adhesive and pasty media
Filling level measurement of foamy media
Hygienic use for float sensors
Generally for media with a conductivity of 5 µS/cm or higher (media with a lower conductivity re-
quire individual clarification regarding the tank contour, temperature, assembly, etc.)
Not suitable for explosive areas
Not suitable for safety-related unit parts (SIL)
1Conformity with standards
The basic safety and health requirements are met through fulfillment of
2014/30/EU Electromagnetic Compatibility
1935/2004/EU Consumer Goods Ordinance
Directive (EU) 10/2011 (articles in contact with food)
EN 61000-6-2:2005 (Interference Immunity)
EN 61000-6-4:2007 + A1:2011 (Interference Emissions)
2Safety instructions
These safety instructions must be followed to
Avoid endangering persons and the environment
Avoid damage to the sensors
Prevent faulty batches during production
The electrical connections may only be performed by persons with the necessary technical skills (e.g. cer-
tified electricians or persons with technical training in electrics) and by persons with the necessary au-
thorization from the operator.
The power supply and the control circuit inputs and outputs must be properly wired. The current state-of-
the-art of electrical connections must be adhered to. See also section 8 "Wiring diagram".
The following details must be noted in particular:
Safety instructions
Electrical connection data
1. All persons involved with the setup, commissioning, operation, service and maintenance of the sen-
sor must be suitably qualified.
2. This operating manual must be followed precisely. The operator must ensure that the personnel has
read and fully understood the operating manual.
3. All work must be performed with utmost care and may only be performed by authorized and trained
personnel. The regulations effective in the country of use regarding the opening and repair of the
devices must be adhered to.
4. The operating manual must be stored in the vicinity of the measurement equipment in an easily ac-
cessible location.
5. The sensor must be de-energized prior to alterations and maintenance.
6. The working area of the operator must offer enough space to minimize the risk of injury.
7. The technical data specified in the operating manual and on the type label must be adhered to.
Warranty coverage shall not be granted for any damage that can be attributed to improper execution of
work.

NSL-F Series Operating Manual 4
3Special features/advantages
Installation in tanks and feed vessels from above, below and diagonally (types NSL-F-00 and NSL-F-
02)
Lateral installation in tanks by means of an angulated sensor and various clamping systems (type
NSL-F-01)
Four-conductor sensor with 4...20-mA output signal
Due to the potentiometric measuring principle, calibration is not required after a change in medium
Individual setting/programming via PC or Simple User Interface
Current signal for measuring range, dry-run message and error message can be adjusted
The M12 plug connection can be aligned by turning the sensor head
2 individual configurable LEDs on the display unit
4Options/accessories
Simple User Interface with small display (retrofittable)
Programming adapter MPI-200 (PC-based)
Tool for releasing the signal module
Preassembled PVC cable
PVC cable with M12 coupling of stainless steel 1.4305, IP 69k, unshielded
oM12-PVC/4–5 m PVC cable, 4-pin, 5 m in length
oM12-PVC/4-10 m PVC cable, 4-pin, 10 m in length
oM12-PVC/4-25 m PVC cable, 4-pin, 25 m in length
PVC cable with M12 coupling of nickel-plated brass, IP 67, shielded
oM12-PVC/4G–5 m PVC cable, 4-pin, 5 m in length
oM12-PVC/4G–10 m PVC cable, 4-pin, 10 m in length
oM12-PVC/4G–25 m PVC cable, 4-pin, 25 m in length
2.2 Factory certificate as per EN 10204 (product-contacting equipment only)
5Installation and connection
Intended use
Information on mounting position
If the sensor is installed in the tank, the measurement signal will not be reliable in an area of 20 mm
(35 mm) from the sealing edge (see dimensional drawing). This means that the 4 mA or 20 mA signal is
located on the bottom weld seam of the measuring rod.
The continuous level sensor NSL-F is set to operate in aqueous media without requiring special set-
tings. In case of highly critical media or special tank contours (with inside fittings such as a pipe), it
may be necessary to adjust some parameters. The parameterization may be changed using the PC-
based MPI-200 programming adapter or the Simple User Interface. The setting can either be set or
changed directly on location or in the office in a dry simulation.
When setting the parameters, it must be ensured that the various authorization leve ls are enabled (see
"Associated setup mode" column). The Monitor and Adjust levels are not required for setting the NSL-
F sensor. These levels can be individually protected with a password and thus made available to specific
users/service personnel. The software in both the PC/MPI-200 and Simple User Interface features a tree
structure.

4...20-mA signal
Filling level height for 4/20-mA signal
"Dry run" warning signal
"Failure" error signal
“Underdriven/overdriven”signal limit
"Underflow/overflow" error signal
Signal simulation (3.95...20.05 mA)
Filling level measurement
Filling level zero point/offset
Filling level slope/gain
Damping/filter
Physical unit
Mounting position
A list of the parameters settings in the continuous level sensor is included with the delivery. These de-
fault parameter values, and the parameter values changed by the user, can be printed out using the MPI-
200 programming adapter software.
When making the settings, note the help texts in the MPI software. These contain additional u seful
information on changing the selected parameter.
6.1 Setup using the MPI-200 programming adapter
The MPI-200 programming adapter is connected to the NSL-F continuous level sensor via the external
MPI-200-F adapter piece. It must be ensured that the NSL-F continuous level sensor is permanently con-
nected to the supply voltage while the parameters are being set.
Connection of the programming adapter MPI-200
1: Connection for M12 connector
(external power supply)
2: USB port for connecting
to a PC incl. power
supply if not supplied externally
3: Connecting cable to
adapter for NSL-F
Signal flow during programming
1
2
3
Connection plug for MPI-200-F adapter as an
intermediate plug between the NSL-F electron-
ics and the MPI-200 connection 3 (see next
figure).
Other manuals for NSL-F series
1
This manual suits for next models
3