manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Angelo Decor
  6. •
  7. Water Pump
  8. •
  9. Angelo Decor Pond Building AD40402 User manual

Angelo Decor Pond Building AD40402 User manual

SAFETY
These pond pumps are carefully inspected and tested to ensure both safety and operating
performance. However, failure to follow the instructions and warnings in this guide mayresult in
pump damage and/or serious injury. There will be no liability for any damage resulting from
failure to observe this guide’s instructions.
1. To reduce risk of electric shock, always disconnect the pump from the electrical
supply before handling or cleaning the pump.
2. To reduce risk of electric shock, inspect the pump and cord for damage before
installation or maintenance
—
replace pump if damage is found.
3. Do not exceed voltage indicated on the label. Pump Umust be connected to an
approved ground fault circuit interrupterU(GFCI) receptacle.
4. Always keep the cord awayfrom high temperature.
5. To achieve best performance, the pump should be placed on a flat surface and
completely submerged in the water.
6. Do not let the pump run dryas this will shorten the pump’s life.
7. Do not lift, hang, or pull the pump bythe power cord.
LIMITED WARRANTY
This pump is warranted to the original user against defective materials and workmanship for
a period of 12 months. Our limited warrantydoes not cover any costs associated with the
installation or removal of products subject to warranty claims or the cost of return of the
pump. The warranty will commence from the date of purchase. Replacement liability is
limited to any part or parts of the unit which have failed due to defective material or
workmanship. Proof of purchase is required for all claims against the limited warranty.
This warrantydoes not extend to damage of the product or part resulting from accident,
misuse, alteration, neglect, abuse, improper installation or normal wear and tear to the
product(s). This limited warranty extends only to the original user of the product.
FOUNTAIN / POND PUMP
COMPONENTS
01. Pump Housing
02. Impeller Assembly
03. Impeller Cover
04. Pre-Filter
05. Pump Output
06. Flow Control
07. ¾” / 1” Output
08. Power Cord
IMPORTANT! BEFORE YOU BEGIN:
This pump is designed for use in “clean water applications”, if you are using ONLY the
integrated pre-filter cartridge. It is not compatible with salt water.
Using this series of pump in an outdoor functional pond environment without using proper
filtration will cause increased maintenance and could result in pump failure due to a
build-up of debris. This type of improper pump care is not covered under warranty.
We strongly recommend using this pump with our Pond Building Series™ Filters (sold
separately), as they include mechanical and biological components that are designed to
protect your pump while improving water quality.
This pump is ideally suited to use in conjunction with our Pond Filter Box 600.
For maximum satisfaction with your project we suggest choosing a filter that slightly
exceeds your current pond plan as most consumers will upgrade features, fish, and plants
during the life cycle of your project.
QUESTIONS?
UPLEASE DO NOT RETURN THIS PRODUCT TO THE STORE.
Visit our website (www.angelodecor.com)for more information and
videos on how to assemble and properly use your product.
For more information on this and other products, please visit our web site:
www.angelodecor.com
To contact us regarding this unit, your options include:
Email:customersupport@angelodecor.com | Phone: (780) 453 - 6646 | Fax: (780) 453- 6620
Angelo Décor International Inc. | 15840 – 118th Avenue | Edmonton, AB |T5V 1C4
Diagram #1
01
04 03
08
02
05
AD40402
WARNING: SAFETY AND ELECTRICAL CONNECTIONS
The pump is supplied with 5m of 3 core electrical cable which is permanently connected and
sealed to the motor. The supply cable cannot be replaced. If the cable is damaged the pump
should be discarded.
1. Pump Umust be connected to an approved ground fault circuit interrupterU(GFCI)
receptacle.
2. Do not connect to anyvoltage other than that stated on the pump.
3. Warning: UAlwaysUunplug or disconnect all appliances from the electrical supply
before putting hands in the water, while equipment is being installed, repaired,
maintained or handled.
4. Do not use the supply cable to lift the pump as this may cause damage.
5. Do not operate or leave the pump in freezing conditions.
6. Do not allow the pump to run dry. The pump must be fully submerged.
INSTALLATION IN POND
Place your pump on top of a flat brick or stone approximately 2” – 4” from the bottom of
your pond to help prevent debris from interfering with the pump’s performance.
Make sure the cable is securely routed to the GFCI electrical supply and is protected
against abrasion and damage.
After electrical installation to test, completely submerge the pump under water. When your
pump is working properly, you will hear a low humming sound and water will be circulating out
of the top outlet. If you do not hear the humming sound or experience performance problems,
please read the troubleshooting tips and care instructions in this guide.
TECHNICAL SPECIFICATIONS
Model
Liters/
Hr
Voltage
Watts
Max
Head
cm
AD40402
1600
120
35
260
HINTS AND TROUBLESHOOTING
CAUTION: UALWAYSUDISCONNECT THE PUMP FROM THE ELECTRICAL
SUPPLY BEFORE HANDLING.
If the pump operates but there is no water flow:
•Make sure the pump is fully submerged.
•Check the tubing for kinks or obstructions. Ensure pump outlet is clear of objects.
•Check water features like spouting statues or fountain nozzles are clean and clear.
•Check water inlet for any obstructions.
If normal water flow has not returned:
•Remove front cover and impeller cover to access rotor area.
•Rotate the rotor to ensure it is not broken or jammed. Remove the rotor
to check it is free from any debris. Rinse the cover and re-assemble.
MAINTENANCE
Regular maintenance must be performed on any warranted item based upon this Owner’s
Guide recommendations. Do not pump heated liquids, and always keep the cord awayfrom
heat and high temperature. Connect the pump to an electrical supply with the proper voltage
and fitted with a Residual Current Device.
1. Always disconnect the pump from the electrical supply before handling it.
2. Pond water must be kept clean using proper filtration components.
3. Always operate the pump completely submerged. Check the water level daily to
ensure the pump will remain submerged. Add water if necessary.
4. Clean the pump periodicallyto prevent mineral deposits and contamination.
5. Disassemble the unit to clean any build up of debris inside the impeller and rotor.
6. Do not operate this pump below 0
°
C, otherwise UFreezing damage May OccurU. If
temperature is likely to fall below 0
°
C remove the pump from the pond, ensure all water is
removed from the pump and the unit is completely dry and stored in a frost-free place.

Other Angelo Decor Water Pump manuals

Angelo Decor P006B User manual

Angelo Decor

Angelo Decor P006B User manual

Angelo Decor AD40035 User manual

Angelo Decor

Angelo Decor AD40035 User manual

Angelo Decor Pond Building AD41500 User manual

Angelo Decor

Angelo Decor Pond Building AD41500 User manual

Angelo Decor Pond Building Series User manual

Angelo Decor

Angelo Decor Pond Building Series User manual

Angelo Decor AD40251 User manual

Angelo Decor

Angelo Decor AD40251 User manual

Angelo Decor Sensible Solar AD40120 User manual

Angelo Decor

Angelo Decor Sensible Solar AD40120 User manual

Angelo Decor Pond Building AD40101 User manual

Angelo Decor

Angelo Decor Pond Building AD40101 User manual

Angelo Decor TP-180 User manual

Angelo Decor

Angelo Decor TP-180 User manual

Angelo Decor Pond Building AD42500 User manual

Angelo Decor

Angelo Decor Pond Building AD42500 User manual

Popular Water Pump manuals by other brands

Fiamma AQUA F 13 L Installation and usage instructions

Fiamma

Fiamma AQUA F 13 L Installation and usage instructions

IBO BETA 25-60 operating manual

IBO

IBO BETA 25-60 operating manual

Graco G3 Series instructions

Graco

Graco G3 Series instructions

SKC QuickTake 30 operating instructions

SKC

SKC QuickTake 30 operating instructions

Comet MTP LW-K 250 Assembly, operation and maintenance instructions

Comet

Comet MTP LW-K 250 Assembly, operation and maintenance instructions

Crane BARNES 8XSHDA Installation and operation manual

Crane

Crane BARNES 8XSHDA Installation and operation manual

Varian Turbo-V 1000 ICE instruction manual

Varian

Varian Turbo-V 1000 ICE instruction manual

Pentair HYDROMATIC HYDR-O-RAIL SYSTEM Installation and service manual

Pentair

Pentair HYDROMATIC HYDR-O-RAIL SYSTEM Installation and service manual

AMT 4786-95 Specifications information and repair parts manual

AMT

AMT 4786-95 Specifications information and repair parts manual

RICE HYDRO ST-312 operating instructions

RICE HYDRO

RICE HYDRO ST-312 operating instructions

Teryair SP10 Operation and maintenance guide

Teryair

Teryair SP10 Operation and maintenance guide

onga SMH35 owner's manual

onga

onga SMH35 owner's manual

Grundfos SP instructions

Grundfos

Grundfos SP instructions

Rietschle SKK 253 02 operating instructions

Rietschle

Rietschle SKK 253 02 operating instructions

MULTIQUIP LS600P Operation manual

MULTIQUIP

MULTIQUIP LS600P Operation manual

EINHELL GC-DP 1020 N Original operating instructions

EINHELL

EINHELL GC-DP 1020 N Original operating instructions

Oerlikon GCB51K operating instructions

Oerlikon

Oerlikon GCB51K operating instructions

Gardner Denver Elmo Rietschle V Series Original operating instructions

Gardner Denver

Gardner Denver Elmo Rietschle V Series Original operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.