manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Angelo Decor
  6. •
  7. Water Pump
  8. •
  9. Angelo Decor Pond Building AD41500 User manual

Angelo Decor Pond Building AD41500 User manual

SAFETY
These pond pumps are carefully inspected and tested to ensure both safety and operating
performance. However, failure to follow the instructions and warnings in this guide mayresult in
pump damage and/or serious injury. There will be no liability for any damage resulting from
failure to observe this guide’s instructions.
1. To reduce risk of electric shock, always disconnect the pump from the electrical
supply before handling or cleaning the pump.
2. To reduce risk of electric shock, inspect the pump and cord for damage before
installation or maintenance
—
replace pump if damage is found.
3. Do not exceed voltage indicated on the label. Pump Umust be connected to an
approved ground fault circuit interrupterU(GFCI) receptacle.
4. Always keep the cord awayfrom high temperature.
5. To achieve best performance, the pump should be placed on a flat surface and
completely submerged in the water.
6. Do not let the pump run dryas this will shorten the pump’s life.
7. Do not lift, hang, or pull the pump bythe power cord.
LIMITED WARRANTY
This pump is warranted to the original user against defective materials and workmanship for
a period of 24 months. Our limited warrantydoes not cover any costs associated with the
installation or removal of products subject to warranty claims or the cost of return of the
pump. The warranty will commence from the date of purchase. Replacement liability is
limited to any part or parts of the unit which have failed due to defective material or
workmanship. Proof of purchase is required for all claims against the limited warranty.
This warrantydoes not extend to damage of the product or part resulting from accident,
misuse, alteration, neglect, abuse, improper installation or normal wear and tear to the
product(s). This limited warranty extends only to the original user of the product.
WATERFALL PUMP AD41500
COMPONENTS
01. Pump Housing
02. Impeller Assembly
03. Impeller Cover
04. Front Cover
05. ¾” / 1” Output
06. Output Adapter
07. Connector
08. Flow Control
09. Power Cord
IMPORTANT! BEFORE YOU BEGIN:
This pump is designed for use in “clean water applications”, if you are using ONLY the
integrated pre-filter cartridge. It is not compatible with salt water.
This pump has a solids handling capacity of 6mm, however using this series of pump in an
outdoor functional pond environment without using proper filtration will cause increased
maintenance and could result in pump failure due to a build-up of debris. This type of
improper pump care is not covered under warranty.
We strongly recommend using this pump with our Pond Building Series™ Filters (sold
separately), as they include mechanical and biological components that are designed to
protect your pump while improving water quality.
This pump is strongly recommended for use in conjunction with our Pond Filter Box 1500,
Waterfall Weir Filter 16”, or Pond Pressure Filter 1000.
For maximum satisfaction with your project, as well as the overall balance and health of
your pond, we suggest choosing a filter that slightly exceeds your current pond plan as
most consumers will upgrade features, fish, and plants during the life cycle of your project.
For more information on this and other products, please visit our web site:
www.angelodecor.com
To contact us regarding this unit, your options include:
Email:customersupport@angelodecor.com | Phone: (780) 453 - 6646 | Fax: (780) 453- 6620
Angelo Décor International Inc. | 15840 – 118th Avenue | Edmonton, AB |T5V 1C4
POND
WARNING: SAFETY AND ELECTRICAL CONNECTIONS
The pump is supplied with 5m of 3 core electrical cable which is permanently connected and
sealed to the motor. The supply cable cannot be replaced. If the cable is damaged the pump
should be discarded.
1. Pump Umust be connected to an approved ground fault circuit interrupterU(GFCI)
receptacle.
2. Do not connect to any voltage other than that stated on the pump.
3. Warning: UAlwaysUunplug or disconnect all appliances from the electricity supply
before putting hands in the water, while equipment is being installed, repaired,
maintained or handled.
4. Do not use the supply cable to lift the pump as this may cause damage.
5. Do not operate or leave the pump in freezing conditions.
6. Do not allow the pump to run dry. The pump must be fully submerged.
INSTALLATION IN POND
Place your pump on top of a flat brick or stone approximately 2” – 4” from the bottom of
your pond to help prevent debris from interfering with the pump’s performance.
Make sure the cable is securely routed to the GFCI electrical supply and is protected
against abrasion and damage.
After electrical installation to test, completely submerge the pump under water. When your
pump is working properly, you will hear a low humming sound and water will be circulating out
of the top outlet. If you do not hear the humming sound or experience performance problems,
please read the troubleshooting tips and care instructions in this guide.
TECHNICAL SPECIFICATIONS
Model
Liters/
Hr
Voltage
Watts
Max
Head
cm
Liters
/Hr @
1m
Liters
/Hr @
2m
AD41500
6000
120
120
600
4930
4000
HINTS AND TROUBLESHOOTING
CAUTION: UALWAYSUDISCONNECT THE PUMP FROM THE ELECTRICAL
SUPPLY BEFORE HANDLING.
If the pump operates but there is no water flow:
•Make sure the pump is fully submerged.
•Check the tubing for kinks or obstructions. Ensure pump outlet is clear of objects.
•Check water inlet for any obstructions.
If normal water flow has not returned:
•Remove front cover and impeller cover to access rotor area.
•Rotate the rotor to ensure it is not broken or jammed. Remove the rotor
to check it is free from any debris. Rinse the cover and re-assemble.
MAINTENANCE
Regular maintenance must be performed on any warranted item based upon this Owner’s
Guide recommendations. Do not pump heated liquids, and always keep the cord away from
heat and high temperature. Connect the pump to an electrical supply with the proper voltage
and fitted with a Residual Current Device.
1. Always disconnect the pump from the electrical supply before handling it.
2. Pond water must be kept clean using proper filtration components.
3. Always operate the pump completelysubmerged. Check the water level dailyto
ensure the pump will remain submerged. Add water if necessary.
4. Clean the pump periodicallyto prevent mineral deposits and contamination.
5. Disassemble the unit to clean any build up of debris inside the impeller and rotor.
6. Do not operate this pump below 0
°
C, otherwise UFreezing damage May OccurU. If
temperature is likely to fall below 0
°
C remove the pump from the pond, ensure all water is
removed from the pump and the unit is completely dry and stored in a frost-free place.

This manual suits for next models

1

Other Angelo Decor Water Pump manuals

Angelo Decor Pond Building AD42500 User manual

Angelo Decor

Angelo Decor Pond Building AD42500 User manual

Angelo Decor Pond Building AD40101 User manual

Angelo Decor

Angelo Decor Pond Building AD40101 User manual

Angelo Decor Pond Building Series User manual

Angelo Decor

Angelo Decor Pond Building Series User manual

Angelo Decor AD40035 User manual

Angelo Decor

Angelo Decor AD40035 User manual

Angelo Decor Pond Building AD40402 User manual

Angelo Decor

Angelo Decor Pond Building AD40402 User manual

Angelo Decor AD40251 User manual

Angelo Decor

Angelo Decor AD40251 User manual

Angelo Decor P006B User manual

Angelo Decor

Angelo Decor P006B User manual

Angelo Decor TP-180 User manual

Angelo Decor

Angelo Decor TP-180 User manual

Angelo Decor Sensible Solar AD40120 User manual

Angelo Decor

Angelo Decor Sensible Solar AD40120 User manual

Popular Water Pump manuals by other brands

Pentair AURORA 411 Installation maintenance repair manual

Pentair

Pentair AURORA 411 Installation maintenance repair manual

AMT 3993-99 Specifications information and repair parts manual

AMT

AMT 3993-99 Specifications information and repair parts manual

AMT 315C Specifications information and repair parts manual

AMT

AMT 315C Specifications information and repair parts manual

Johnson Pump AQUA JET WPS 3.4 instruction manual

Johnson Pump

Johnson Pump AQUA JET WPS 3.4 instruction manual

Pentair Lincoln J Series Operator's manual

Pentair

Pentair Lincoln J Series Operator's manual

hp-TECHNIK UHE-WH4 Series Installation, maintenance and operation instructions

hp-TECHNIK

hp-TECHNIK UHE-WH4 Series Installation, maintenance and operation instructions

Zoeller EX6220 owner's manual

Zoeller

Zoeller EX6220 owner's manual

Intex Quick-Fill AP609 manual

Intex

Intex Quick-Fill AP609 manual

Ingersoll-Rand ARO PD10P Series Operator's manual

Ingersoll-Rand

Ingersoll-Rand ARO PD10P Series Operator's manual

Grundfos MTA Series Installation and operating instructions

Grundfos

Grundfos MTA Series Installation and operating instructions

Viking pump 495 Series Technical & service manual

Viking pump

Viking pump 495 Series Technical & service manual

Weir Safety Iron Operating and maintenance instructions

Weir

Weir Safety Iron Operating and maintenance instructions

Wilo SiBoost Smart Series Installation and operating instructions

Wilo

Wilo SiBoost Smart Series Installation and operating instructions

Pfeiffer Vacuum OKTA 300 operating instructions

Pfeiffer Vacuum

Pfeiffer Vacuum OKTA 300 operating instructions

Enerpac ZG5420MX-R instruction sheet

Enerpac

Enerpac ZG5420MX-R instruction sheet

Pontec PondoVario 1000 operating instructions

Pontec

Pontec PondoVario 1000 operating instructions

SCHMITT U Series Original operating manual

SCHMITT

SCHMITT U Series Original operating manual

Sears CRAFTSMAN HYDROGLASS 390.250284 owner's manual

Sears

Sears CRAFTSMAN HYDROGLASS 390.250284 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.