Annso DCC-150T User manual

User Manual
DCC-150T/300T, DCC-150R/300R
-CAT6 KVM Extender Transmitter & Receiver 150/300 meters

Legal Information
First English printing, October 2002
Information in this document has been carefully checked for accuracy; however, no guarantee is given to the correctness
of the contents. The information in this document is subject to change without notice. We are not liable for any injury or
loss that results from the use of this equipment.
Safety Instructions
Please read all of these instructions carefully before you use the device. Save this manual for
future reference.
■Unplug equipment before cleaning. Don’t use liquid or spray detergent; use a moist cloth.
■Keep equipment away from excessive humidity and heat. Preferably, keep it in an air-conditioned environment with
temperatures not exceeding 40º Celsius (104º Fahrenheit).
■When installing, place the equipment on a sturdy, level surface to prevent it from accidentally falling and causing
damage to other equipment or injury to persons nearby.
■When the equipment is in an open position, do not cover, block or in any way obstruct the gap between it and the
power supply. Proper air convection is necessary to keep it from overheating.
■Arrange the equipment’s power cord in such a way that others won’t trip or fall over it.
■If you are using a power cord that didn’t ship with the equipment, ensure that it is rated for the voltage and current
labeled on the equipment’s electrical ratings label. The voltage rating on the cord should be higher than the one listed
on the equipment’s ratings label.
■Observe all precautions and warnings attached to the equipment.
■If you don’t intend on using the equipment for a long time, disconnect it from the power outlet to prevent being
damaged by transient over-voltage.
■Keep all liquids away from the equipment to minimize the risk of accidental spillage. Liquid spilled on to the power
supply or on other hardware may cause damage, fire or electrical shock.
■Only qualified service personnel should open the chassis. Opening it yourself could damage the equipment and
invalidate its warranty.
■If any part of the equipment becomes damaged or stops functioning, have it checked by qualified service personnel.
What the warranty does not cover
■Any product, on which the serial number has been defaced, modified or removed.
■Damage, deterioration or malfunction resulting from:
□Accident, misuse, neglect, fire, water, lightning, or other acts of nature, unauthorized product modification, or
failure to follow instructions supplied with the product.
□Repair or attempted repair by anyone not authorized by us.
□Any damage of the product due to shipment.
□Removal or installation of the product.
□Causes external to the product, such as electric power fluctuation or failure.
□Use of supplies or parts not meeting our specifications.
□Normal wear and tear.
□Any other causes which does not relate to a product defect.
■Removal, installation, and set-up service charges.
Regulatory Notices Federal Communications Commission (FCC)
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of
the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation.
Any changes or modifications made to this equipment may void the user’s authority to operate this equipment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following measures:
■Re-position or relocate the receiving antenna.
■Increase the separation between the equipment and receiver.
■Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

< Part. 3 > Keyboard Hotkey Command P. 7
< Part. 2 > Application
2.1 Extending the KVM console port to 150 / 300 meters
2.2 Extending the computer to KVM port to 150 / 300 meters
2.3 Extending the computer up to 150 / 300 meters
P. 4
P.5
P. 6
< Part. 1 > DCC-150T/300T, DCC-150R/300R
1.1 Package Contents
1.2 Transmitter
1.3 Receiver
Contents
P. 1
P. 2
P. 3

■It is very important to mount the equipment in a suitable cabinet or on a stable surface.
■Make sure the place has a good ventilation, is out of direct sunlight, away from sources of excessive
dust, dirt, heat, water, moisture and vibration.
The equipment comes with the standard parts shown in package content. Check and make sure they are
included and in good condition. If anything is missing, or damaged, contact the supplier immediately.
Unpacking
Before Installation
P. 1
< 1.1 > Package Contents
Receiver
< Part 1 >
Transmitter
DCC-150/300 Receiver and Transmitter X 1
- USB-VGA 1.8 M Combo KVM cable X 1
- Power adapter w/ DC12V 1A X 2
Receiv
er
DCC-150T/300T, DCC-150R/300R
- User manual CD x 1

P. 2
Power
LED
Status
LED
LED Status Description
POWER Solid Blue Power is on ( from the local computer or power adapter )
No Light There is no Power
ON LINE Solid Red The connection to Receiver is active
Flashing Red Transmitter is sending or receiving data, or auto-adjusting the signal
No Light No connection established
< 1.2 > Transmitter
Transmitter Specification
Console Port 1 x DB-15 VGA, up to 1920 x 1440
2 x USB connector for KB & mouse
Remote I / O 1 x RJ-45 port, connect the Receiver up to 1280 x 1024 resolution
(150 meters)
Local computer 1 x DB-15 combo KVM port
LED 2 (power / on line)
Power Input 100~240VAC, 50/60Hz via AC/DC cord
Operating Temperature 0 to 50°C degree
Storage Temperature -20 to 60°C degree
Operating Humidity 90%, non-condensing
Storage Humidity 90%, non-condensing
Safety FCC & CE certified
Environmental RoHS2 compliant
VGA
Power KB
Mouse
Local
Computer Remote I/O
Front
Rear
1 x RJ-45 port, connect the Receiver up to 1024 x 768 resolution
(300 meters)
Security User name and password (only for DCC-300T/R)
Port selection
N/A
OSD Hotkey, Status (only for DCC-300T/R)
Housing
Metal

VGA
Power KB
Mouse
Local
Computer Remote I/O
Front
Remote
LED
Local
LED
Rear
Receiver Specification
P. 3
LED Status Description
REMOTE Solid Yellow Remote port is connected to the Transmitter
Solid Red Remote port is selected
Flashing Red Remote port is selected but no connection established
or auto-adjusting the signal
No Light Remote port is not connected or the power is OFF
LOCAL Solid Yellow Local port is connected to the local PC / KVM
Solid Red Local port is selected
Flashing Red Local port ( PC / KVM ) is selected but no PC signal is detected
No Light Local port is not connected or the power is OFF
< 1.3 > Receiver
Select button
Button Description
SELECT Switch between REMOTE ( Transmitter ) and LOCAL ( Receiver )
Console Port 1 x DB-15 VGA, up to 1920 x 1440
2 x USB connector for KB & mouse
Remote I / O 1 x RJ-45 port, connect the Receiver up to 1280 x 1024 resolution
(150 meters)
Local computer 1 x DB-15 combo KVM port
LED 2 (local / remote)
Power Input 100~240VAC, 50/60Hz via AC/DC cord
Operating Temperature 0 to 50°C degree
Storage Temperature -20 to 60°C degree
Operating Humidity 90%, non-condensing
Storage Humidity 90%, non-condensing
Safety FCC & CE certified
Environmental RoHS2 compliant
1 x RJ-45 port, connect the Receiver up to 1024 x 768 resolution
(300 meters)
Security User name and password (only for DCC-300T/R)
Port selection
Hot Key / Push button
OSD Hotkey, Status (only for DCC-300T/R)
Housing Metal

combo
KVM cable
USB Console
2468
10121416
1357
9111315
18202224
26283032
17192123
25272931
KVM switch
P. 4
< 2.1 > Extending the KVM console port to 150 / 300 meters
< Part 2 > Application
Transmitter Front
Cat6 cable
up to 150 / 300 meters
Monitor
Receiver
combo
KVM cable
Front
Monitor

Transmitter
P. 5
Cat6 cable
up to 150 / 300 meters
2468
10121416
1357
9111315
18202224
26283032
17192123
25272931
Cat6 KVM port
12345678
DB-15 KVM port
Cat5/6 dongle
OR VGA
< 2.2 > Extending the computer to KVM port to 150 / 300 meters
Monitor
Front
KB
Mouse
Front
combo
KVM cable
Receiver

Cat6 cable
up to 150 / 300 m
< 2.3 > Extending the computer up to 150 / 300 meters
P. 6
Monitor
combo
KVM cable
Monitor
combo
KVM cable
Transmitter
Front
Receiver
Front

< Part 3 > Keyboard Hotkey Command
Command Function
F1 To show OSD menu (only for DCC-300T/R)
F2 To select Hotkey type on menu (only for DCC-300T/R)
F3
To change user name and password (only for DCC-300T/R)
F4 To log in (where to enter user name and password) -- only for DCC-300T/R
You can switch the Receiver from “LOCAL” to “REMOTE” and vice-versa through simple key sequences
made by the remote console side. To send commands to the Receiver, you must press the hotkey (default is
Caps Lock) twice within 2 seconds. You will hear a beep sound confirming you are in the hotkey mode. If you
do not press any key during hotkey mode over 2 seconds, the hotkey mode will be terminated and back to
normal state.
The default hotkey is Caps Lock but you can change hotkey as your application convenience.
The table blow lists all the supported hotkey commands.
Example:
P. 7
CTo switch between Local and Remote ports
QTo turn the beep sound on or off
STo activate the Auto-Scan function. Auto-scan Remote
and Local port every 8 seconds repeatedly.
AFor auto-adjust video signal of remote port to optimum
+
+
Caps
Lock
Caps
Lock
C

To show OSD menu (only for DCC-300T/R)
S E C U R I T Y
U S E R N A M E
PASS
W
O R D
00000000
:00000000
R E M O T E C O N S O L E
H O T K E Y n u m
L O C A L C O N S O L E
H O T K E Y n u m
(F1)
F1
H E L P
F 2 H O T K E Y
F 3 R E V I S E I D
F 4 S E C U R I T Y
When Receiver power on, log in window will present as follow, please enter
:
default user name
default password
or
When log in or switch the port by buttons on control board, menu or hotkey, window
will show the current setting - current hotkey type of Local or Remote of Reveicer.
Please press any key or using mouse to close the window.
Press Caps lock twice and press
, and the window will present as follow:

(F2)
H O T K E Y L I S T
1 . s c r o l l
2 . n u m
3 . c a p s
4 . L c t r l 5 . R c t r l
6 . L a l t 7 . R a l t
8 . L w i n 9 . R w i n
(F3)
S E C U R I T Y
U S E R N A M E
P A S S W O R D
R E V I S E I D
U S E R N A M E
P A S S W O R D
V E R I F Y
F2
Press Caps lock twice and press
, and the window will present as follow:
then select the hot key type by pressing number key
F3
Press Caps lock twice and press
, and the window will present as follow:
Enter the current user name and password to revise ID:
Please enter new user name and password, and enter the password again to verify,
user name and password require maximun 8 characters (A~z and 0~9).
(F4)
S E C U R I T Y
U S E R N A M E
P A S S W O R D
F4
Press Caps lock twice and press
, and the window will present as follow:
This manual suits for next models
3
Table of contents