ADX-16
3. INSTALLATION
First ADX 16 box (with power supply jack, “ADX 16 S”)
Connect the su lier AC ada ter to the “Power” jack
Connect the o tical out ut of your first device (e.g. mixing desk) to the “TOSLINK In” jack, and the o tical
in ut to the “TOSLINK Out” jack.
Second ADX 16 box (“ADX 16 R”)
Connect the o tical out ut of your second device (e.g. DAC/ADC) to the “TOSLINK In” jack, and the o tical
in ut to the “TOSLINK Out” jack.
The second box does not need a se arate ower su ly because it is owered from the first one over the
Cat5 cable.
Cat5 connection
Use u to 100m (330 ft) Cat5(e), Cat6(e) or Cat7 cable to connect the first ADX-16 box to the second one.
Note: For the ADX-16's signal transmission, the quality of the cable doesn't matter much (we use 100 meters
of the chea est cable we were able to get for testing). However, we recommend using good quality cable if
mechanical stress is an issue.
4. SPECIFICATIONS
Parameter Value
Maximum length of Cat5 cable 100m / 330 ft
Su orted data formats ADAT® (8ch@48kHz 4ch@96kHz/SMUX, 2ch@192kHz/QMUX er direction)
S/PDIF (u to 2ch@96kHz er direction)
Dolby® Digital 5.1 (AC-3)
DTS®
all other formats ca able of TOSLINK transmission
Note: Both directions o erate inde endent from each other
Latency added to the link < 1µs when run over 100m
Cat5 cable in assignment
Pin Color Signal
1 orange/white TX DATA +*
2 orange TX DATA –
3 green/white RX DATA + *
4 blue/white +12V
5 blue +12V
6 green RX DATA – *
7 brown/white GND
8 brown GND
* TX/RX functions seen from unit with ower connector, ma ed to RX/TX on the other
unit.
3
CAUTION:
Use the Cat5 cable ONLY to connect the ADX-16 boxes together!
NEVER connect any ADX-16 device to a com uter network ort, network switch or likewise!
The ADX-16 uses a ro rietary rotocol which is incom atible with Ethernet equi ment,
and such a connection may damage both the ADX-16 and the connected device!