Anritsu MA24104A User manual

User Guide
MA24104A
Inline High Power Sensor
Average Power, 600 MHz to 4 GHz
Anritsu Company
490 Jarvis Drive
Morgan Hill, CA 95037-2809
USA
PN: 10585-00016
Revision: A
Printed: February 2009
Copyright 2009 Anritsu Company

WARRANTY
The Anritsu product(s) listed on the title page is (are) warranted against defects in materials and workmanship for
one (1) year from the date of shipment.
Anritsu’s obligation covers repairing or replacing products which prove to be defective during the warranty period.
Buyers shall prepay transportation charges for equipment returned to Anritsu for warranty repairs. Obligation is
limited to the original purchaser. Anritsu is not liable for consequential damages.
LIMITATION OF WARRANTY
The foregoing warranty does not apply to defects resulting from improper or inadequate maintenance by the User,
unauthorized modification or misuse, or operation outside of the specifications of the product. No other warranty is
expressed or implied, and the remedies provided herein are the User’s sole and exclusive remedies.
DISCLAIMER OF WARRANTY
DISCLAIMER OF WARRANTIES. TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, ANRITSU
COMPANY AND ITS SUPPLIERS DISCLAIM ALL WARRANTIES, EITHER EXPRESS OR IMPLIED,
INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, WITH REGARD TO THE SOFTWARE PRODUCT. THE USER ASSUMES THE ENTIRE
RISK OF USING THE PROGRAM. ANY LIABILITY OF PROVIDER OR MANUFACTURER WILL BE LIMITED
EXCLUSIVELY TO PRODUCT REPLACEMENT.
NO LIABILITY FOR CONSEQUENTIAL DAMAGES. TO THE MAXIMUM EXTENT PERMITTED BY
APPLICABLE LAW, IN NO EVENT SHALL ANRITSU COMPANY OR ITS SUPPLIERS BE LIABLE FOR ANY
SPECIAL, INCIDENTAL, INDIRECT, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING,
WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, LOSS
OF BUSINESS INFORMATION, OR ANY OTHER PECUNIARY LOSS) ARISING OUT OF THE USE OF OR
INABILITY TO USE THE SOFTWARE PRODUCTS, EVEN IF ANRITSU COMPANY HAS BEEN ADVISED OF
THE POSSIBILITY OF SUCH DAMAGES. BECAUSE SOME STATES AND JURISDICTIONS DO NOT ALLOW
THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, THE
ABOVE LIMITATION MAY NOT APPLY TO YOU.
TRADEMARK ACKNOWLEDGMENTS
Microsoft, Windows, Windows Vista, Microsoft Office, Word, Access, Excel, PowerPoint, Visual Studio, Visual Basic,
and .NET are all registered trademarks of the Microsoft Corporation.
NOTICE
Anritsu Company has prepared this manual for use by Anritsu Company personnel and customers as a guide for the
proper installation, operation and maintenance of Anritsu Company equipment and computer programs. The
drawings, specifications, and information contained herein are the property of Anritsu Company, and any
unauthorized use or disclosure of these drawings, specifications, and information is prohibited; they shall not be
reproduced, copied, or used in whole or in part as the basis for manufacture or sale of any equipment or software
programs without the prior written consent of Anritsu Company.
UPDATES
Updates, if any, can be downloaded from the Documents area of the Anritsu web site at:
http://www.us.anritsu.com

ANRITSU COMPANY SOFTWARE LICENSE AGREEMENT
IMPORTANT-READ CAREFULLY BEFORE OPENING THE SOFTWARE PACKET. BY OPENING THE PACKET
CONTAINING THE SOFTWARE, YOU ARE AGREEING TO BE BOUND BY THE TERMS OF THIS AGREEMENT.
THIS IS A LEGAL AGREEMENT BETWEEN YOURSELF, AND YOUR EMPLOYER, IF APPLICABLE, AND
ANRITSU COMPANY (“ACUS”). IF YOU DO NOT AGREE WITH ALL OF THE TERMS OF THIS AGREEMENT,
PROMPTLY RETURN THE UNOPENED SOFTWARE PACKAGE, AND THE ACCOMPANYING
DOCUMENTATION TO ANRITSU FOR FULL CREDIT.
SOFTWARE LICENSE AGREEMENT
1. GRANT OF LICENSE. This License Agreement permits you to use enclosed software program (the “Software”) on a
computer. The SOFTWARE is in use on a computer when it is loaded into temporary memory (i.e. RAM) , installed
into permanent memory (i.e. hard disk, CD-ROM, or other storage device), or installed/ loaded into any appropriate
Anritsu product. All rights not expressly granted are reserved to ACUS. This Grant of License is not subject to
transfer or assignment by Licensee.
2. COPYRIGHT. This SOFTWARE is owned by ACUS and is protected by United States copyright laws and
international treaty provisions. Furthermore, it is considered by ACUS to be ACUS proprietary information.
Therefore, you must treat the SOFTWARE like any other copyrighted or proprietary material except that you may
either (a) make one copy of the SOFTWARE solely for backup or archival purposes, or (b) transfer the SOFTWARE to
a single hard disk, provided you keep the original solely for backup or archival purposes. You may NOT copy any
written documentation accompanying the SOFTWARE.
3. OTHER RESTRICTIONS. You may not reverse engineer, decompile, or disassemble the SOFTWARE, nor may you
publish the SOFTWARE on the internet, or load the SOFTWARE onto your company’s network.
4. DUAL MEDIA SOFTWARE. If the SOFTWARE package contains both 3.5 in. disks and CD-ROM , then you may
only use the disks appropriate for your computer. You may not use the other disk on another computer, or loan, lease,
or transfer them to another user except as part of the permanent transfer of all SOFTWARE and written materials.
5. WARRANTY. ACUS warrants for a period of one (1) year from date of delivery that the SOFTWARE will, unless
modified, perform the functions described in the accompanying documentation. ACUS’s sole obligation is to undertake
to correct or replace any reported error conditions.
ACUS DOES NOT WARRANT THAT THE SOFTWARE WILL RUN PROPERLY ON ALL HARDWARE, THAT THE
SOFTWARE WILL MEET LICENSEES REQUIREMENTS, OR THAT ALL SOFTWARE ERRORS WILL BE
CORRECTED.
THE WARRANTIES ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, WHETHER
EXPRESSED OR IMPLIED, INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE.
ACUS SHALL NOT BE LIABLE FOR DIRECT, INDIRECT, INCIDENTAL, SPECIAL, OR CONSEQUENTIAL
DAMAGES, , OR DAMAGES FOR LOSS OF PROFITS, REVENUE, DATA, OR USE, INCURRED BY licensee,
REGARDLESS OF WHETHER IN TORT OR CONTRACT, AND REGARDLESS OF WHETHER LICENSEE HAS
ADVISED ACUS OF THE POSSIBILITY OF SUCH LOSSES.
6. Export Control. Licensee agrees that it shall not export or re-export the software covered hereunder, or any portion
thereof, directly, or through others, to the proscribed countries listed in Section 779.4 and associated or successor
sections of the U.S. Export Administration Regulations unless properly authorized by the U. S. Government.
Licensee further agrees to fully comply with all of the rules and regulations regarding export of this software that may
be issued from time to time by the Japanese Ministry of International Trade and Industry.
7. Any breach of the terms or conditions of this Grant of License will result in termination of the license granted
hereunder. Upon termination of the license granted hereunder, Licensee shall return all copies of the software to
ACUS, or certify their destruction in writing.
8. This agreement, and all of the rights hereunder, shall be interpreted and determined by the laws of the State of
California, and all disputes shall be subject to the jurisdiction of the Courts within the State of California.


MA24104A UG PN: 10585-00016, Rev. A i
Table of Contents
Chapter 1—General Information
1-1 Scope of Manual. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
1-2 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
1-3 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
1-4 Initial Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
1-5 Identification Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Customer Asset Tag Placement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
1-6 Preparation for Storage/Shipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Chapter 2—Installation (PC Only)
2-1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2-2 Hardware and Software Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2-3 Driver Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Chapter 3—Using the Power Sensor
3-1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
3-2 Sensor Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
3-3 Graphical User Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Buttons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
Data Entry Fields. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
Display Window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Status Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Menu Bar. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
File Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
Tools Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
Data Logging Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6
Power Graph . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7
Offset Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9
Session Restore. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11
3-4 Making Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11
Basic Power Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12
Connecting the Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13
Zeroing the Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13
Calibrating the Sensor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13
Applying a Calibration Factor Correction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13
Optimizing the Readings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13

ii PN: 10585-00016, Rev. A MA24104A UG
3-5 Measurement Considerations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-15
Time Varying Signals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-15
Multitone Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-15
Noise and Averaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-15
Settling Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-16
Maximum Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-16
3-6 Uncertainty of a Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17
Uncertainty Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17
3-7 Error States. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-19
Chapter 4—Remote Operation
4-1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
4-2 Remote Operation Commands Summary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
4-3 Remote Operation Command Details. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
Appendix A—Connector Care and Handling
Appendix B—Sample Visual Basic Code
B-1 Demo Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1
B-2 Using the Demo Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1
Appendix C—Upgrading the Firmware
Index
Table of Contents (Continued)

MA24104A UG PN: 10585-00016, Rev. A 1-1
Chapter 1 — General Information
1-1 Scope of Manual
This manual provides general information, installation, and operating information for the Anritsu MA24104A
Inline High Power Sensor. Throughout this manual, the terms MA24104A, inline high power sensor, and
power sensor will be used interchangeably to refer to the device. Manual organization is shown in the table of
contents.
1-2 Introduction
This chapter contains general information about the MA24104A power sensor. It includes a general description
of the device and information on its identification number, information on initial inspection, and preparation
for storage and shipment.
1-3 Description
The MA24104A power sensor is a highly accurate, standalone instrument that communicates with a PC via
USB. The MA24104A also communicates with many Anritsu handheld instruments, such as Spectrum Master,
BTS Master, VNA Master, Cell Master, and Site Master (Option 19 required in these instruments). The power
measurement capability of MA24104A is intended to mimic that of a traditional thermal (thermo-electric)
power sensor. Therefore, it is ideal for measuring the average power of CW or modulated RF waveforms such
as 3G, 4G, OFDM, and multi-tone signals. In other words, it measures true RMS power regardless of the type
of input signal.
1-4 Initial Inspection
Inspect the shipping container for damage. If the shipping container is damaged, retain it until the contents of
the shipment have been checked against the packing list and the power sensor has been checked for
mechanical and electrical operation. The following items are included with every MA24104A shipment:
•MA24104A, inline high power sensor
•40-168-R, external power supply
•2000-1566-R, USB 2.0A to Mini-B cable
•800-441, RS232 cable
•69747, AA Alkaline batteries (qty 3)
•2300-525, CD containing required software and manuals
If the shipment is incomplete or if the power sensor is damaged mechanically or electrically, notify your local
sales representative or Anritsu Customer Service. If the shipping container is damaged or shows signs of
stress, notify the carrier as well as Anritsu. Keep the shipping materials for the carrier's inspection.
1-5 Identification Number
All Anritsu power sensors are assigned a unique seven digit serial number, such as “0701012”. The serial
number is printed on a label that is affixed to the unit. When ordering parts or corresponding with Anritsu
Customer Service, please use the correct serial number with reference to the specific instrument's model
number (for example, model MA24104A power sensor, serial number: 0701012).

Preparation for Storage/Shipment General Information
1-2 PN: 10585-00016, Rev. A MA24104A UG
Customer Asset Tag Placement
When affixing an asset tag to the MA24104A, please use the area indicated below to insure that the asset tag is
retained with the product during service.
1-6 Preparation for Storage/Shipment
Preparing the power sensor for storage consists of cleaning the unit, packing the inside with moisture-
absorbing desiccant crystals, and storing the unit in the recommended temperature environment. Please refer
to the data sheet for storage temperature recommendations.
To provide maximum protection against damage in transit, the power sensor should be repackaged in the
original shipping container. If this container is no longer available and the unit is being returned to Anritsu for
repair, please advise Anritsu Customer Service; they will send a new shipping container free of charge. In the
event neither of these two options is possible, instructions for packaging and shipment are given below:
• Use a Suitable Container: Obtain a corrugated cardboard carton. This carton should have inside
dimensions of no less than 15 cm larger than the unit dimensions to allow for cushioning.
• Protect the Instrument: Surround the unit with polyethylene sheeting to protect the finish.
• Cushion the Instrument: Cushion the instrument on all sides by tightly packing urethane foam
between the carton and the unit. Provide at least three inches of dunnage on all sides.
• Seal the Container: Seal the carton by using either shipping tape or an industrial stapler.
• Address the Container: If the instrument is being returned to Anritsu for service, mark the address of
the appropriate Anritsu service center and your return address on the carton in one or more prominent
locations.
Figure 1-1. Customer Asset Tag Placement
Customer
Asset Tag

MA24104A UG PN: 10585-00016, Rev. A 2-1
Chapter 2 — Installation (PC Only)
2-1 Introduction
This chapter provides information and instructions on operating the MA24104A power sensor. It contains the
following:
•Hardware and Software Requirements for the Anritsu Power Meter Application
•Driver Installation procedure for properly installing the driver for the sensor
2-2 Hardware and Software Requirements
Please make sure that the following minimum requirements are met for installing and using the software:
•Intel®Pentium®III or equivalent processor
•Microsoft®Windows Vista®(32-bit only), Windows XP or Windows 2000
•512 MB of RAM
•100 MB of available hard-disk space
•1024 × 768 display resolution
•PC or laptop with a USB port and CD-ROM drive
2-3 Driver Installation
The driver must be installed before the MA24104A power sensor can be used. Follow the steps below as a guide
for proper installation:
1. Insert the installation CD in the drive of your computer. If the installation menu does not start
automatically, open the file named Startup.htm located on the CD.
Figure 2-1. Anritsu Power Meter Installation Menu
Note: If required, please install the Microsoft®.Net Framework, version 2.0.

Driver Installation Installation (PC Only)
2-2 PN: 10585-00016, Rev. A MA24104A UG
2. Click Install Power Meter Application and select Run to start the installation.
3. Click Next in the following screen to begin the installation process.
4. Browse for the installation folder, select the desired permissions, and then click Next. The default
installation directory is: C:\Program Files\Anritsu\AnritsuPowerMeter
Figure 2-2. Anritsu Power Meter Installation
Figure 2-3. Anritsu Power Meter Installation

Installation (PC Only) Driver Installation
MA24104A UG PN: 10585-00016, Rev. A 2-3
5. Select I Agree to the license agreement, and then click Next.
6. Select Next to continue with the software installation.
Figure 2-4. License Agreement
Figure 2-5. Confirm Installation

Driver Installation Installation (PC Only)
2-4 PN: 10585-00016, Rev. A MA24104A UG
The software will then install to the selected location.
7. When the installation completes, click Close.
8. Connect the MA24104A power sensor to the USB port of the PC with the supplied USB cable, then press
and hold the ON button for one second. The status LED lights green indicating that the sensor is turned
ON.
Figure 2-6. Installing Anritsu Power Meter Application
Figure 2-7. Application Installation Complete

Installation (PC Only) Driver Installation
MA24104A UG PN: 10585-00016, Rev. A 2-5
9. When the Found New Hardware Wizard installation screen appears, select No, not this time to search for
software, and then click Next. If the Wizard does not start, refer to Appendix C, “Serial Port
Compatibility” for troubleshooting information.
10. Select Install from a list or specific location (Advanced), and then click Next.
Figure 2-8. Found New Hardware Wizard
Figure 2-9. Found New Hardware Wizard

Driver Installation Installation (PC Only)
2-6 PN: 10585-00016, Rev. A MA24104A UG
11. Select Don’t search. I will choose the driver to install, and then click Next.
12. Select the hardware type Computer, and then click Next.
Figure 2-10. Found New Hardware Wizard
Figure 2-11. Found New Hardware Wizard

Installation (PC Only) Driver Installation
MA24104A UG PN: 10585-00016, Rev. A 2-7
13. Click Have Disk..., and then click Next.
14. Browse to the location on your hard drive where you installed the program. If the default settings were
chosen during the application installation, click Browse..., as shown below, and then select:
C:\Program Files\Anritsu\AnritsuInlinePowerMeter\AnritsuMA24104A.inf
15. Click Open, then click OK.
Figure 2-12. Found New Hardware Wizard
Figure 2-13. Install From Disk

Driver Installation Installation (PC Only)
2-8 PN: 10585-00016, Rev. A MA24104A UG
16. Select Anritsu MA24104A from the list, and then click Next as shown below.
17. The Hardware Installation Warning dialog will appear as shown in Figure 2-15. Click Continue Anyway.
Figure 2-14. Found New Hardware Wizard
Figure 2-15. Hardware Installation

Installation (PC Only) Driver Installation
MA24104A UG PN: 10585-00016, Rev. A 2-9
18. Click Finish to close the wizard.
19. The MA24104A is now ready for use. Launch the Anritsu Power Meter application from the new desktop
icon or from the Start | Programs menu. Refer to Chapter 3 for information about using the Anritsu
Power Meter application.
Figure 2-16. Found New Hardware Wizard


MA24104A UG PN: 10585-00016, Rev. A 3-1
Chapter 3 — Using the Power Sensor
3-1 Introduction
This chapter provides information on using the Anritsu Power Meter application with the MA24104A inline
high power sensor. It provides a description ofthe Graphical User Interface, various settings ofthe application,
basic procedures for Making Measurements, as well as information about Uncertainty of a Measurement.
3-2 Sensor Overview
The power sensor’s connectors are illustrated in the figure below:
Index Description
1RF Input
2Power ON/OFF
3USB Mini-B Port (for connection with a PC or Anritsu Handheld instrument)
4
2-color LED (reports functional status of the sensor)
Green: Sensor ON, Status OK
Amber: Error Condition (see Table 3-5)
Blinking: Low Battery
5RF Output
6RS232 Port (for connection with Anritsu handheld instruments)
7DC Input (for RS232 use without batteries)
8
Battery Compartment (supports 3AA size batteries)
Note: When using battery power with the RS232 interface, the MA24104A enables an auto shutdown
(sleep) feature. If the RS232 bus is disconnected or becomes inactive, the power sensor shuts down
(sleeps) to preserve battery power. The sensor automatically powers up (wakes up) when the host is
reconnected or becomes active. Zeroing is then required before taking measurements.
Figure 3-1. MA24104A Sensor Overview
2
1
34
5
6
7
8

Graphical User Interface Using the Power Sensor
3-2 PN: 10585-00016, Rev. A MA24104A UG
3-3 Graphical User Interface
The graphical user interface layout is divided into five sections as illustrated in the figure below:
The Anritsu Power Meter application always launches in the default state as described below:
•Frequency:600 MHz
• Power Units: W
• Averages: 1
• Fixed Offset: 0dB
• Time Aperture: Low (fast mode)
Communication with the sensor does not take place until the Apply button is clicked or the Enter key on the
keyboard is pressed.
Index Description
1Menu Bar
2Display Window
3Buttons
4Data Entry Fields
5Status Bar
Figure 3-2. Anritsu Power Meter Application Overview
2
1
5
3
4
Table of contents
Other Anritsu Accessories manuals
Popular Accessories manuals by other brands

IFM Electronic
IFM Electronic efector300 SM8000 operating instructions

Yellowtec
Yellowtec PC Audio Interface user manual

senva
senva TotalSense Series installation instructions

Chillout
Chillout AIRCON installation guide

Mesalabs
Mesalabs EZTest 1410 Operation manual

Vega
Vega VEGACAL 62 operating instructions