APPA 30T User manual

RU
EN
TC
SC
JP
AC / DC Current transducer
Клещи-преобразователь переменного AC / DC
User Manual / 使用說明書 / 使用说明书
ユーザーマニュアル
Руководство пользователя
30T
LIMITE D
WARRAN TY
YEAR S

Read First
!
!Safety Information
Understand and follow operating instructions carefully. Use
the meter only as specified in this manual; otherwise, the
protection provided by the meter may be impaired.
This identifies hazardous conditions and actions that could
cause BODILY HARM or DEATH.
To avoid possible danger, follow below guidelines.
• If the equipment is used in a manner not specified by
the manufacturer, the protection provided by the
equipment may be impaired.
• Always use proper terminals, switch position, and range
for measurements.
• To reduce the risk of fire or electric shock, do not use this
product around explosive gas or in damp locations.
• Do not apply more than the rated voltage, as marked on
meter, between terminals or between any terminal and
earth ground.
• To avoid false readings that can lead to electric shock
and injury, replace battery as soon as low battery
indicator blinks.
• Avoid working alone so assistance can be rendered.
• Do not use the Tester if the Tester is not operating
properly or if it is wet.8
• Individual protective device must be used if hazardous
live parts in the installation where the measurement is
to be carried out could be accessible.
• Individual protective equipment should be used if
HAZARDOUS LIVE parts in the installation where
measurement is to be carried out could be
ACCESSIBLE.
Warning
!
30T EN
1

Symbols as marked on the Tester and
Instruction card
Maintenance
Do not attempt to repair this Meter. It contains no
user-serviceable parts. Repair or serving should only be
performed by qualified personal.
Cleaning
Periodically wipe the case with a dry cloth and detergent.
Do not use abrasives or solvents.
Risk of electric shock
See instruction card
DC measurement
Equipment protected by double or reinforced
insulation
Battery
Earth
AC measurement
Conforms to EU directives
Application around and removal from
hazardous live conductors is permitted
Do not discard this product or throw away.
Both direct and alternating current
!
30T EN
2

Front Panel Illustration
1. Jaw
2. Trigger
3. Barrier for Hand Guard
4. Function swith
5. ZERO A( ) button
6. LED indicator
• Power on indicator (Green, flash while powering-on)
• Low battery on indicator (Red)
7. Coiled Cable Connector - Voltage output
30T EN
3

Making Basic Measurements
Measuring AC/DC Ampere
The barrier on the JAW is indicating the limit of safe
access of the hand-held part, do not hold over the barrier
when in normal use.
Warning
!
Do not hold
the meter across
the Barrier
Hand Guard
earth for the jaw
With respect to
Barrier for
CAT III 600V
DMM
30T EN
4

DCA ZERO
DMM
Zero A
button
Press
DMM
Auto Power off (APO)
Wake up the meter by switching the slide switch.
30T EN
5

Specifications
1-1 General Specifications
Dimensions : 66 mm (W) x 185 mm (L) x 40 mm (H).
Weight : 270 grams (including battery).
Power requirement : 9V battery x1
Auto power Off : The meter automatically turns the power
off after powering up and no operation for
35 ± 10minutes.
Battery life (based on Alkaline Battery) : 66 hours
Maximum Conductor Size : 22mm
LVD : EN61010-1, EN61010-031, EN61010-2-032
EMC : EN61326-1
Installation Category : CAT.III. 600V for Jaw
Battery Replacement
Replace the battery as soon as the low battery indicator
appears, to avoid false reading. Refer to the following
figure to replace the batteries
Unscrew the screw by a cross screw driver, then open the
battery cover.
– Remove discharged batteries
– Replace by new batteries
– Close the battery cover and re-screw the screw
30T EN
6

1-2 Environmental Conditions
Indoor Use.
Maximum operating altitude : 2000m (6562ft)
Operating temperature : 0°C ~ 50°C, ≦75%RH
Storage temperature :
-20 to +60°C, 0 to 80% RH (no batteries).
Temperature coefficient :
0.2 x (Specified accuracy) / °C, < 18°C, > 28°C
Pollution Degree : 2
Shock vibration :
MIL-PRF-28800F for A class 2 Instrument
Drop Protection :
4 Feet Drop to hardwood on concrete Floor
Type of sensing : Hall effect sensing for AC and DC
1-3 Electrical Specifications
Accuracy is given as ± (% of reading + counts of least
significant digit) at 23°C ± 5°C, with relative humidity less
than 80% R.H. Accuracy is specified for a period of one
year after calibration.
Position Error of Clamp: Add ±1% of LCD reading.
The circuits directly connected to Low-voltage
installation.
The building installation.
The source of the Low-voltage installation.
II
III
IV
30T EN
7

Limited Warranty
This meter is warranted to the original purchaser against
defects in material and workmanship for 3 years from the
date of purchase.
During this warranty period, Manufacturer will, at its
option, replace or repair the defective unit, subject to
verification of the defect or malfunction.This warranty does
not cover fuses, disposable batteries, or damage from
abuse, neglect, accident, unauthorized repair, alteration,
contamination, or abnormal conditions of operation or
handling. Any implied warranties arising out of the sale of
this product, including but not limited to implied warranties
of merchantability and fitness for a particular purpose, are
limited to the above.
The manufacturer shall not be liable for loss of use of the
instrument or other incidental or consequential damages,
expenses, or economic loss, or for any claim or claims for
such damage, expense or economic loss. Some states or
countries laws vary, so the above limitations or exclusions
may not apply to you.
Ampere
Frequency Response : DC,AC 40Hz to 400Hz
Output Impedance : < 10kΩ
Overload Protection : AC/DC 300A
Range Output Ratio Accuracy
(0 - 40)A 10mV/A ±(1.0% +0.2A)
±(1.9% +2A)
(40 - 200)A 1mV/A
1mV/A
±(1.0% +1A)
(200 - 300)A
30T EN
8

!
!
!
!
30T TC
9

30T TC
10

!
CAT III 600V
DMM
30T TC
11

DMM DMM
30T TC
12

±
66
22mm
LVD : EN61010-1, EN61010-031, EN61010-2-032
EMC : EN61326-1
30T TC
螺絲
電池蓋
�伏特電池
電池連接器
13

室內使用。
2000m (6562)
0°C ~ 50°C, ≦75%
-20 to +60°C, 0 to 80% (電池需移除)。
0.2 x (指定精確度) / °C, < 18°C, > 28°C
2
A級2儀器MIL-PRF-28800F
4呎掉落至水泥地上硬木。
交流電及直流電霍爾效應感應
當溫度為23°C±5°C,相對溼度≦80%時,精確度為±
確度為±讀值+最顯著小數位數)且精確度指定為校正後一
年內適用。
加±1%於LCD讀
II
III
IV
30T TC
: DC,AC 40Hz 400Hz
: < 10kΩ
: AC/DC 300A
(0 - 40)A 10mV/A ±(1.0% +0.2A)
±(1.9% +2A)
(40 - 200)A 1mV/A
1mV/A
±(1.0% +1A)
(200 - 300)A
14

30T TC
15

!
!
!
!
30T SC
16

30T SC
17

!
CAT III 600V
DMM
30T SC
18

DMM DMM
30T SC
19
Table of contents
Languages:
Other APPA Transducer manuals