AquaLabo LOG-AQUA User manual

LOG-AQUA
User Manual
Version 1.1

LOG-AQUA
- 2 -
It is important that you read the Quick Start Guide in a
controlled environment prior to installation.
Set up, activate, and successfully test the entire system
(LOG-AQUA, sensors, and antenna connection) indoors, in a
controlled environment, before going to the field for
installation
!

LOG-AQUA
- 3 -
SCHEMATIC
Analog port
7,3cm
(2,8 po)
17,4 cm
(6,9 po)
IP 68/ NEMA 6P Wavelet
mechanical enclosure
Slots for zip ties and/or bolts for
mounting
Panel connectors protector
13,3 cm
(5,2 po)
Magnetic Activator
FRONT
BOTTOM
External power port
Serial Port
Discrete port
Cellular antenna port

LOG-AQUA
- 4 -
INTERNAL
UPPER ENCLOSURE
INTERNAL
LOWER ENCLOSURE
Military-grade lithium battery pack
(field replaceable, non-rechargeable)
Interface board ON/OFF switch
Indicator LEDs
GSM antenna
SIM card slot #2
Memory card
GPS antenna
SIM card slot #1
Cellular modem

LOG-AQUA
- 5 -
COMPONENTS
1
3
LOG-AQUA
Logger Activator
1x
1x
Panel connectors protector
1
3
Cellular antenna and mounting
bracket
(REQUIRED and sold separately)
4x
2x
4x
Zip ties, screws, and anchors

LOG-AQUA
- 6 -
SENSOR CONNECTION
Connect the sensor cable(s) assembly with the field attachable connector to
the mating panel connector on the LOG-AQUA. See page 17 for more
details. Turn the adjustable stainless-steel end piece to secure the field
attachable connector to the LOG-AQUA.
!
CAUTION: Do not turn the black plastic hood of the connector.
Turning the black hood may cause the wires to disconnect,
break, and/or damage the connector pins.
TURN HERE
DO NOT
TURN HERE

LOG-AQUA
- 7 -
EXTERNAL ANTENNA CONNECTION
Connect the Cellular antenna to the antenna port.
The antenna does not appear in the remaining depictions
in this guide, but it must remain connected after it is
properly secured to the appropriate panel connectors.
Place the magnetic activator on the embossed logo on the front of the LOG-
AQUA enclosure.
The LOG-AQUA will initiate a 15-minute test mode of sampling and send a
few transmissions of data. The device will then return to its default
configuration
Magnetic activator

LOG-AQUA
- 8 -
PROTECTION DU LOGGER
After connecting sensors and antenna, place the LOG-AQUA protector above
the connector ports and secure the Wavelet protector into the LOG-AQUA
enclosure.
Upper Clips
Lower Clips
Protector Arches
a. Insert the two lower clips into the two lower holes of the LOG-AQUA
enclosure.
b. Snap the upper clips into place in the two grooves above the panel
connector
a
b
CAUTION: The protector is provided to shield the connector from
tampering or over-exposure that could result in disconnected wiring.
If you need to remove the protector, grasp it at the protector arches and
pull up. The protector will snap off.
.

LOG-AQUA
- 9 -
LOG-AQUA ACTIVATION
The LED light on the back cover of the Wavelet indicates the device status.
Access the AQUALABO user interface at XXXX by using your log-in
credentials. Expect data to appear 5 – 10 minutes after the test mode is
initiated

LOG-AQUA
- 10 -
LOG-AQUA ACTIVATION
The screen display should resemble the following:
If the LOG-AQUA transmits properly,
then the test was successful.
You can now install the LOG-AQUA in
the field and begin to collect and view
your data!
If data does not transmit properly,
change the LOG-AQUA installation
location and activate again.
If the problem persists, contact the
Aqualabo Team for help:
sav@aqualabo.fr
+33(0)4 11 71 97 41

LOG-AQUA
- 11 -
SPECIAL INSTALLATIONS LOCATIONS
WEAK SIGNAL LOCATIONS
If the LOG-AQUA is installed in an area
with weak cellular signal, activate the
LOG-AQUA using the magnetic
activator.
You can log into the user interface
using your credentials to validate that
the device is transmitting and sensor
Wait for at least 15 minutes, then log
in to the user interface to confirm
successful transmission.
UNDERGROUND/INDOOR
If the LOG-AQUA is installed in an area
with weak cellular signal, activate the
LOG-AQUA and place in the intended
installation location with closed
doors/access hatch.
Wait for at least 15 minutes, then log in
to the user interface to confirm the
updated location on the map.
Before installation, initiate the GPS out
by activating the LOG-AQUA (see step
3).

LOG-AQUA
- 12 -
MONTAGE DU LOG-AQUA
Additional tools and/or materials might be required (not included)
Rotary hammer
Screwdriver with bit

LOG-AQUA
- 13 -
LOG-AQUA MOUNTING
Secure the LOG-AQUA on a wall, pipe, or other secure mount location by
using zip ties or screws.
OU
Wall
mounted
OU
4x
4x
1x
1x
Pipe
mounted
2x

LOG-AQUA
- 14 -
ANTENNA MOUNTING
DOs
✓Ensure the antenna connector is
secured tightly to the panel
connector.
✓Mount antenna under the open sky or
at least 50cm (20in.) beneath any
object.
✓Mount antenna at least 5 to 10cm (2
to 4in.) away from wall.
✓Mount antenna at least 5cm (2in.)
away from the LOG-AQUA.
✓Finalize the antenna setup to the
exact physical conditions. For
example, close the lid, close the door,
etc.
✓Make sure you have a signal and a
successful data transmission via the
user interface
✓If needed during installation, use the
Transmit Now command with the
magnetic LOG-AQUA Activator to
initiate more rapid transmissions.
DONTs
✓Do not attach the antenna to the LOG-
AQUA.
✓Do not wrap cables, zip ties, or other
items around the antenna.
IMPORTANT NOTE :
There are a few- minutes of delay between a
successful transmission and the use of either
of these methods for initiating data
transmission. Repeating the use of either
method will not expedite data transmission.
WARNING :
If installing in a highly corrosive
environment such as a sewer, apply technical
grease to the antenna and sensor field
attachable connectors after securing them
to the panel connectors.

LOG-AQUA
- 15 -
ANTENNA MOUNTING - TROUBLESHOOTING
If the Wavelet does not transmit, move the antenna to a different position.
If the Wavelet still does not transmit after multiple attempts at repositioning the
antenna, consider using an alternative solution, such as an in-road or a high-gain
antenna.

LOG-AQUA
- 16 -
YOUR LOG-AQUA
IS SUCCESSFULLY INSTALLED !

LOG-AQUA
- 17 -
LOG-AQUA PINOUT
Panel
Connector
Inputs
1
4x analog and 1x discrete
2
RS485, RS232, SDI-12 (16 channels)
3
4x discrete
4
6-24VDC
4
3
1
2

LOG-AQUA
- 18 -
AQUALABO
90 Rue du Professeur Paul Milliez • 94506 Champigny sur Marne • France
Tel.: +33 (0)1 55 09 10 10
Hotline: +33(0)4 11 71 97 41
E-mail: info@aqualabo.fr
Website: https://www.aqualabo.fr/
Table of contents
Popular Data Logger manuals by other brands

TESTO
TESTO 184 instruction manual

Allen-Bradley
Allen-Bradley Dynamix 2500 user manual

Sunhillo
Sunhillo RICI 5000 010-10 user manual

Racelogic
Racelogic Performance Box Touch V2 Installing

Onset
Onset HOBO MX Series quick start

process-informatik
process-informatik EtherSens Energy Handling-Short Instruction