AQUALUX CAPSULEO User manual

1
USER’S MANUAL
FLEXIBLE WATER TANK
Rain water recovery
Read carefully and keep for further reference.

2
PREAMBLE
WARNING
The system must be installed in compliance with these document recommendations in
order to ensure a proper functioning.
Each owner can use the rain water fell on his/her soil according to the 641 article of the French Code
Civil. Therefore, each owner can recover and keep this water in tanks in order to water the plants,
clean the car or the floors.
Current governmental aid please check WWW.developpement-durable.gouv.fr
The August-21st 2008 ministerial decree regarding the use and recovery of rain water fulfils the decree
introducing a tax credit on the installations and give details on the authorized installation, use and
upkeep of those equipments.
RECOMMENDATION
The rain water is non-drinkable:
It can’t be used in ways needing drinkable water even if it is filtered. Its use is allowed outside –
watering, filling, car cleaning…- or inside –toilets supplying, floor cleaning, laundry- under conditions.

3
1 –EQUIPMENT SUPPLIED
Référem3) Reference
Volume
(m3)
Volume
(litre)
Length
(m)
Width
(m)
Height
(m)
Weight
(kg)
105804
0.5
500
1.40
1.45
0.4
9
In the box you will find:
-
-
-
-
-
-
-1 flexible tank equipped with a thread overflow ” and a thread output 1”
-1 non-assembled parts sachet (repair kit, sluice gate…)
-1 flexible pipe (ref GLA32376)
-1 gutter recovering device (ref 106181)

4
Composition of the sachet :
GLOSSARY
MARKER
Aqualux
reference
DESIGNATION
UN
QTY
1
TECTEF12
TEFLON ROLLER 12MX12MM
U.
1
2
200199
REPAIR KIT 25G
u.
1
3
PIECE OF FABRIC (30cm x 30cm square)
u.
1
4
106183
TE 90° TAR 1''1/4 PG
u.
1
5
106182
FLUTED THREAD END PIECE 1-1/4X32
U.
1
6
COLSX143252
SERFLEX COLLAR SX 14+ 32-52
u.
2
7
103004
TAP NOSE 26x34
u.
1
8
102948
SLUICE GATE 221 MF 1 BRASS
u.
1
9
102661
Flexible tank User’s manual
u.
1
4
1
2
3
5
6
7
8
9

5
Sachet of the gutter device composition :
MARKER
DESIGNATION
UN
QTY
1
Gutter recovering device
U.
1
2
Pipe adaptor
u.
1
3
Adaptor DN 70/80
u.
1
4
Adaptor DN 70/80
u.
1
2 –TANK INSTALLATION
WARNING !
Do not open the box with a sharp tool which can damage the flexible water tank
The floor must be resistant enough to support the full flexible water tank without caving
in. Reminder: 1000 liters = 1 ton
-Create a horizontal and flat surface with dirt or sand –recommended.
-Drop the optional –ref ROULFEU25X2M –carpet off the floor without any fold
-Roll out the tank. WARNING never pull the sluice gate ! Make sure the filling vent hole and
the overflow are upwards. Make sure there is space around the sluice gate.
-Check the sluice gate is tightened enough
-Check the screws are tightened enough
1
3
2
4

6
Step 1: Set up of the brass sluice gate -ref: 102948- and the tap nose (ref: 103004). We advise to put
TEFLON (pictures below)
Set up of the tap nose
Warning: When there is a problem with the opening direction of the sluice gate handle. You can switch
it by unscrewing the screw above the sluice gate and invert the handle. See the following pictures.

7
Step 2: Assembly of the fluted adaptor with the 90° T
Installation of the TEFLON
Step 3: Assembly of the 90° T with the overflow –on top of the tank
Installation of the TEFLON.
Screw the assembled parts on the tank.
Warning: you must hold the overflow above the tightening screw. Otherwise there will be loosening
and leaking risks

8
Result:
Step 4: Assembly of the glanaflex and the fluted end piece with the tightening collars

9
Step 5: Assembly of the flexible pipe on the recovering device with a tightening collar.
Step 6: Installation of the device on the gutter
Features of the device:
-keep the water unspoiled by the roof
-Avoid mud
-Well-spread filtering surface thanks to a stainless steel filtering
grid.
-Easy to set up/ remove/ clean
-Winter/summer use
-Can be used as automatic overflow
-Designed for roof surfaces up to 80m²
-Designed for DN 100 gutters
-Delivered with DN 80 adaptor
-3 side output available DN 70 –50 –32
-240mm x 145mm x 250mm

10
Installation:

11
3 –FILLING AND DISTRIBUTION
The user is responsible for the compliance with the regulations of his/her installation.
FILLING
Tank without pack
The filling is made through the T which is also used as overflow and vent hole.
You must connect the tank with flexible pipes in order to tolerate the water level variations.
Do not tense the pipes. You must be able to make a buckle in front of the tank.
Once the tank is filled the water flows through either the device overflow or the tank overflow. Do not
block the overflow.
DISTRIBUTION
Tank without pack
Distribution of the rain water is ensured by the brass sluice gate by connecting a garden pipe.
4 –MAINTENANCE
Flexible water tanks do not need a specific maintenance nevertheless, you must check the well-
functioning of the sluice gates and that the bent overflow is not obstructed.
We advise a tank cleaning once a year if your tank is outside –you can use the trapdoor.
It is compulsory to insulate the output/input pipes and the sluice gate or optional packs during the
winter.
Scheduled upkeep: check on the tightening of the different parts
In case of a long storage of the tank you have to make sure it is entirely dry then fold it and protect the
different parts.
5- REPAIRS
A repair kit is provided with the tank. Before you proceed to the repair you must carefully clean the
damaged area and scrub both the surfaces to stick with sandpaper. Then proceed to the following
instructions:
-Cut the PVC part provided with the kit (larger than the surface to repair, smooth angles)
-Spread the glue on the PVC part
-Place the PVC part on the damaged area by evacuating all the air bubbles
-Keep contact between both the pieces
-Wait 24 hours to get a perfect adhesion

12
GUARANTEE
The flexible tank is guaranteed 2 years for the fabric and 1 year for each manufacture defect and
accessories starting from the delivery date.
An intervention regarding the guarantee will not make it last longer. However if the repair lasts more
than 7 days, the guarantee will extend the same duration.
The agreement of the AQUALUX after-sales department is compulsory in order to get repairs or
replacement in the guarantee situation.
Furthermore, the purchase invoice will be demanded when the guarantee is invoked. This guarantee will
only apply if this user’s manual is strictly respected.
This guarantee will apply in France only.
In the scope of this warranty, AQUALUX' only obligation will be (at AQUALUX' choice) the free
replacement or repair of the product or component recognized as defective by AQUALUX' services. All
other fees will be at buyer’s cost.
Guarantee won’t prevail in case of a visible defect. Also excluded: defects and damages due to regular
use, defects caused by a non-conform use or installation and modifications of the product done without
AQUALUX’ agreement as well as holes, tears, colours, folds, stains. The set up, upkeep, filling, emptying,
moving and all the other products used aren’t under guarantee either.
WARNING !
Do not open the box with a tool which may damage the flexible water tank.
ZA DE LA MASSANE–13210 ST REMY DE PROVENCE –France
www.aqualux.com
SAS au capital de 4 000 000 € - RCS TARASCON B390 039 989
This manual suits for next models
1
Table of contents
Popular Water Heater manuals by other brands

Polaris
Polaris PGC instruction manual

Reflex
Reflex Fillcontrol Plus operating manual

STIEBEL ELTRON
STIEBEL ELTRON DHM 3 Installation

Bosch
Bosch GWH 425 PN Applications manual

State Water Heaters
State Water Heaters GP650 HTPDT Service handbook

Rheem
Rheem 31202519V Owner's guide and installation instructions

Fala
Fala STROKKUR-1 manual

clage
clage CFX-U Installing instructions for the professional

Kenmore
Kenmore 153.338071 owner's manual

ACV
ACV WaterMaster 25 Evo Installation operation & maintenance

Strom-Electrical
Strom-Electrical SEUS6L installation manual

Bosch
Bosch Tronic 1000 T Installation and operating instructions