POND AND FOUNTAIN PUMPS
instructions manual
the answers for your watergarden made easy!
DESCRIPTION AND FEATURES
manufactured with advanced technology to
provide you with the best quality pump for your
pond or water feature.
many different applications including
fountains and water features, either
submersible or inline.
centrifugal pump, therefore they cannot
pump from a lower level when used inline.
easy cleaning and maintenance.
encapsulated in epoxy resin, ensuring safe
operation under water.
is required.
encased impellor parts and ceramic shafts
water applications.
suction cup feet, enabling use on both
horizontal and vertical surfaces.
lights and accessories.
INSTALLATION
install weatherproof power point near
to the pond or water feature, (within the
ensure the pump is on a stable surface
that is free of sludge, sand and other
debris, and connect tubing to the outlet or
attach fountain kit.
installed inline, then plug in power cord
and switch on.
MAINTENANCE
Disconnect power cord from the power supply
pump by the power cord.
The only serviceable item is the impellor set.
The motor unit of the pump is encapsulated
with epoxy resin and does not need
lubrication.
cooled; if pump becomes restricted it will
overheat and could cause permanent damage.
restricted.
is damaged, the pump must be discarded.
The impellor set is a wearing consumable part.
Regular inspections, cleaning and maintenance
of impellor is necessary to ensure longer
impellor life.
it should be replaced (available from your dealer
serious damage to pump.
1. Disconnect the power cord from
the power supply before performing
maintenance.
fountain kit and remove front cage or
foam prefilter from pump.
sponge off the threaded core and wash
out in a bucket of pond or dechlorinated
that comes with the pump, take it out of
the cage and wash it out as above.
4. Remove the impellor cover by turning
clockwise and pulling out (it may be quite
Gently remove the impellor and shaft,
use long nose pliers if needed. Take care
because they are brittle.
5. Clean the impellor with a brush, checking
a damaged impellor, permanent damage
may occur.
the impellor onto the shaft. The impellor
will pull itself in by magnetic force, this is
normal (take care not to pinch your fingers
sure the shaft is located properly on the
impellor cover. You may need to place
rubber impellor locator on end of shaft to
locate in impellor cover properly.
cage or foam prefilter.
water, connect to power supply and turn on.
AP1000FP AP2400FP AP4800FP
240 240 240
35
2 2.5 4.5
1000 2400
25mm
1
8
11 127
9
2 53 4 6
* For non-submersible applications
purposes only.
10