TROUBLESHOOTING
Heat Pump Fails to Operate:
Is the display illuminated?
If not, ensure the main breaker (located at the power supply panel) and the
disconnect switch (located near the heat pump) are both turned ON.
Is the code “FLO” displayed?
,IVRFKHFNWREHVXUHWKDWWKHFLUFXODWLQJSXPSLVRSHUDWLQJDQGWKHÀOWHU
is clean. There may also be a valve positioned incorrectly allowing water to
E\SDVVWKHKHDWSXPS%HVXUHZDWHULVÁRZLQJWKURXJKWKHKHDWHU
Is the Pool or Spa thermostat selected for the correct body of water to be
heated, have you tried selecting a higher temperature setting, and have you
chosen the correct “Mode” of operation?
If not, the actual water temperature may be above that of the selected thermo-
stat. Raise the desired water temperature above the actual water temperature;
the fan should start, and after approximately four (4) minutes, the “Heating”
light should illuminate. If the heat pump still fails to start, and the unit is not
in defrost (heat-only unit defrost display code is: “FS”), contact Aquatherm
Customer Support: 239-482-0606.
Heat Pump Running... but is it Heating?
Is the air blowing out of the top of the unit noticeably cooler than the
surrounding air?
(With heating indicator light illuminated, a 9°F to 12°F difference is typical.)
If not, contact Aquatherm for service at: 239-482-0606. %XWÀUVW, be sure all
air coil surfaces are free from obstructions– low roof overhangs, landscaping,
ZDOOVIHQFHVHWFFDQUHVWULFWDLUÁRZ7KHKHDWSXPSQHHGVJRRGDLUÁRZWR
RSHUDWHDWSHDNHIÀFLHQF\
How many hours/day does the circulating pump operate?
Cooler weather conditions, or heating to a higher than normal temperature,
may necessitate running the heat pump for a longer period of time. Was
the heater sized considering the use of a pool blanket (check with installing
dealer)? A blanket can be useful in permitting shorter run times, in turn lead-
ing to substantial energy cost savings.
What is the outside air temperature?
The heat pump may be in the defrost mode if air temperatures are below 50°F.
With Heat-Only models, if the heater is in defrost, the code: ”FS” will be
displayed. If air temperatures are not cold, but the heater remains in defrost,
contact Aquatherm at 239-482-0606.