12
6-2. EHSE-YM9ECR1.UK, ERSE-YM9ECR1.UK
NL
S3S2S1
NL
S3S2S1
To outdoor
unit
TB1
OG OG
YE
YE
GNYE
To outdoor
unit
Power supply
~/N 230V 50Hz
TB1
OG
BU
RD
BU
RD
YE
GNYE
1
3
BK BK
BK
BK
1
3
OG
BN
OG
OG
BN
YE
Indoor unit powered
by independent source
Indoor unit powered
via outdoor unit
CIRCUIT
BREAKER
1
3
1
3
LED1
LED2
LED3
LED4
TBI.1
1310 12 141174 65 932 81
TBI.2
1310 12 141174 65 932 81
IN6
IN1
IN2
IN3
IN4
IN5
IN7
t
°
t
°
THW8
THW7
THW6
t
°
THW9
t
°
THWB1
t
°
THWB2
t
°
Main remote
controller
1 2
12
CN20
(RD)
TH1
t
°
13
CN21
(YE)
TH2
t
°
14
THW1
THW2
CNW12
(RD)
t
°
t
°
12
THW5 CNW5
(WH)
t
°
CN108
5
1
Wireless receiver
(Option)
WiFi adapter
(Option)
5
1
5
1
CN22
(BU)
1
2
3
4
5
6
1
3
5
7
1
*1
5
3
Close
Open
N
X6
X15
X12
X7
TBO.4
TBO.3
TBO.2
TBO.1
F1
F2
M
2WV2a
MXV
MP2
MP1
M
1
~
1
3
1
3
CNV1
(WH)
1
3CNBHT
(BK)
CNBC
(GY)
CNBH
(WH)
X11
X9
X8
X13
X10
X4
X14
X3
X2
X1
X5B
X5A
1
2
3
4
5
6
7
8
1
2
3
4
5
6
1
2
3
4
5
6
1
1
3
3
3
CNP1
(WH)
CNP4
(RD)
CNPWM
(WH)
TBO.1
TBO.2
TBO.3
TBO.4
TAB1
F2 F1
IEC T6.3AL250V IEC T10AL250V
SW1
SW2
SW3
SW4
SW5
1
8
1
8
1
1
3
5
1
3
1
3
8
1
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
7
8
1
2
3
4
5
6
8
1
6
2
1
4
6
2
1
1
2
4
6
4
6
CNBH
(WH)
CNBC
(GY)
1
1
3
1
2
CNBHT
(BK)
1
3
1
3
7
CNIH
(OG)
TBI.2
126 10
14
8
137 119
4
53
2
1
6
4
2
1
CNIH
(OG)
MP3
M
1
~
2 2 2
ECB1
L2
(3)
L1
(1) L3
(5)
BHCP
BK
BK
WH
WHWH
BK
RDRD
BU/No.4
WH/No.2
WH/No.3
WH/No.1
BU/No.5
BU/No.6
RD
VT
VT
PK
PK
WH
WH
GY
GY
BHC2
BHC1
BHT
642
531 A1
A2
642
531 A1
A2
BH1
BHF
BH2
24 6
Power supply
to Booster heater
642
531 A1
A2
2
2
2
2
2
1
1
3
5
7
3
1
3
3~ 400V 50Hz
IN8
IN9
IN10
1310 12 141174 65 932 81
TBI.3
TBI.3
2 4 6 8 10 12 14
1357 9 11 13
2 4 6 8 10 12 14
1357 9 11 13
TBI.1
2WV2b
M
1
~
TBO.2
3WV
*1
3WV
M
1
~
4 5 6 TBO.2
2WV1
2WV1
M
1
~
4 5 6
M
1
~
1
3
CNBHT
(BK)
CNBC
(GY)
CNBH
(WH)
Signal output
(Boiler)
Signal output
(Error)
Signal output
(Defrost)
Signal output
(Comp. ON)
Signal output
(Cooling)
CNP1
(WH)
CNP4
(RD)
CNV1
(WH)
CN3C
(BU)
CNPWM
(WH)
CNRF
(WH)
CN105
(RD)
CN22
(BU)
CNIT
(BU)
CN01
(WH)
–
+–
+–
+
CN3C
(BU)
CN3C
(BU)
CN01
(WH)
CN01
(WH)
CN01
(WH)
Tool
Tool
Conductor Conductor
Outline view Top view
<How to use TBO.1 to 4>
Connect them using either way as shown below.
1
2
1
2
1
4
1
3
CNW5
(WH)
CN21
(YE)
CNW12
(RD)
CN20
(RD)
1
4
CN1A
(WH)
M
1
~
Flow
Sensor
14
CN1A
(WH)
1.Symbolsusedinwiringdiagramare,
: connector, : terminal block.
2.Indoorunitandoutdoorunitconnecting
wireshavepolarities,makesureto
matchterminalnumbers(S1,S2,S3)
forcorrectwirings.
3.Sincetheoutdoorunitsideelectric
wiringmaychange,besuretocheck
theoutdoorunitelectricwiringdiagram
for service.
Table 1 Signal Inputs
Name
Terminal block
Connector
Item OFF(Open) ON(Short)
IN1 TBI.113-14 —Room thermostat 1
input
RefertoSW2-1in"6-5.DIPswitch
setting".
IN2 TBI.1 11-12 — Flowswitch1input RefertoSW2-2in"6-5.DIPswitch
setting".
IN3 TBI.19-10 —Flowswitch2input
(Zone1)
RefertoSW3-2in"6-5.DIPswitch
setting".
IN4 TBI.17-8 — Demand control input Normal HeatsourceOFF/
Boileroperation*2
IN5 TBI.15-6 —Outdoor thermostat
input*1
Standard opera-
tion
Heateroperation/
Boileroperation*2
IN6 TBI.13-4 —Room thermostat 2
input
RefertoSW3-1in"6-5.DIPswitch
setting".
IN7 TBI.1 1-2 — Flowswitch3input
(Zone2)
RefertoSW3-3in"6-5.DIPswitch
setting".
IN8 TBI.31-2 —Electricenergymeter1
Refer to installation manual.
IN9 TBI.33-4 —Electricenergymeter2
IN10
TBI.35-6 — Heat meter
IN1A
TBI.312-14 CN1A Flowsensor
*1.Ifusingoutdoorthermostatforcontrollingoperationofheaters,thelifetimeofthe
heaters and related parts may be reduced.
*2.Toturnontheboileroperation,usethemainremotecontrollertoselect“Boiler”in
“Externalinputsetting”screenintheservicemenu.
Table 2 Outputs
Name
Terminal block
Connector
Item OFF ON
OUT1
TBO.1 1-2 CNP1 Watercirculationpump1output(Spaceheating/
cooling&DHW) OFF ON
OUT2
TBO.13-4 —Watercirculationpump2output(Spaceheating/
coolingforZone1) OFF ON
OUT3
TBO.15-6 —
Watercirculationpump3output(Spaceheating/
coolingforZone2)*1 OFF ON
2-wayvalve2boutput*2
OUT4
TBO.24-6 CNV1 3-wayvalve(2-wayvalve)output Heating DHW
OUT5
TBO.2 1-2 —Mixingvalveoutput*1 Stop Close
TBO.22-3 Open
OUT6
—
CNBH1-3
Booster heater 1 output OFF ON
OUT7
—
CNBH5-7
Booster heater 2 output OFF ON
OUT8
TBO.45-6 —Coolingsignaloutput OFF ON
OUT9
TBO.43-4 CNIH Immersion heater output OFF ON
OUT10
TBO.31-2 — Boiler output OFF ON
OUT11
TBO.33-4 — Error output Normal Error
OUT12
TBO.35-6 — Defrost output Normal Defrost
OUT13
TBO.41-2 —2-wayvalve2aoutput*2 OFF ON
OUT14
—CNP4 Watercirculationpump4output(DHW) OFF ON
OUT15
TBO.37-8 —Comp.ONsignal OFF ON
Donotconnecttotheterminalsthatareindicatedas“—”inthe“Terminalblock”eld.
*1.For2-zonetemperaturecontrol.
*2.For2-zonevalveON/OFFcontrol.
Symbol Name
TB1 Terminalblock<Powersupply,Outdoorunit>
ECB1 Earthleakagecircuitbreakerforboosterheater
MP1 Watercirculationpump1
(Spaceheating/cooling&DHW)
MP2 Watercirculationpump2
(Spaceheating/coolingforZone1)(Localsupply)
MP3 Watercirculationpump3
(Spaceheating/coolingforZone2)(Localsupply)
3WV(2WV1)
3-wayvalve(2-wayvalve1)(Localsupply)
2WV2a 2-wayvalve(ForZone1)(Localsupply)
2WV2b 2-wayvalve(ForZone2)(Localsupply)
MXV Mixingvalve(Localsupply)
BHT Thermostat for booster heater
BHF Thermal fuse for booster heater
BH1 Booster heater 1
BH2 Booster heater 2
BHC1 Contactor for booster heater 1
BHC2 Contactor for booster heater 2
BHCP Contactor for booster heater protection
Symbol Name
TH1 Thermistor(Roomtemp.)(Option)
TH2 Thermistor(Ref.liquidtemp.)
THW1 Thermistor(Flowwatertemp.)
THW2 Thermistor(Returnwatertemp.)
THW5 Thermistor(DHWtankwatertemp.)(Option)
THW6 Thermistor(Zone1owtemp.)(Option)
THW7 Thermistor(Zone1returntemp.)(Option)
THW8 Thermistor(Zone2owtemp.)(Option)
THW9 Thermistor(Zone2returntemp.)(Option)
THWB1 Thermistor(Boilerowtemp.)(Option)
THWB2 Thermistor(Boilerreturntemp.)(Option)
IN1 Roomthermostat1(Localsupply)
IN2 Flowswitch1(Localsupply)
IN3 Flowswitch2(Localsupply)
IN4 Demandcontrol(Localsupply)
IN5 Outdoorthermostat(Localsupply)
IN6 Roomthermostat2(Localsupply)
IN7 Flowswitch3(Localsupply)
Symbol Name
IN8 Electricenergymeter1(Localsupply)
IN9 Electricenergymeter2(Localsupply)
IN10 Heatmeter(Localsupply)
IN1A Flowsensor
FLOWTEMP.CONTROLLER(FTC5)
TBO.1−4
Terminal block <Outputs>
TBI.1−3 Terminalblock<SignalInputs,Thermistor>
F1 Fuse(IECT10AL250V)
F2 Fuse(IECT6.3AL250V)
SW1−5 DIPswitch(See"6-5.DIPswitchsetting".)
X1−15 Relay
LED1 Powersupply(FTC5)
LED2 Powersupply(Mainremotecontroller)
LED3 Communication(FTC5-Outdoorunit)
LED4 ReadingorwritingdatatoSDcard
CNPWM
PumpspeedcontrolsignalforMP1
CN108 SD card connector