LED Upgrade Kit Installation Guide
Fixture: PROS - Providence Small
A R C H I T E C T U R A L A R E A L I G H T I N G
93065348 REV A
PAGE 1/5
TM
www.aal.net
16555 East Gale Avenue
City of Industry, CA 91745
626.968.5666
6 3 A74011 DISCT3M MNI 14-250DFI AS NOTED
5 2 A84337 WSHR-No. 10 SPLIT LK SS
4 2 A84252 SCR-10-24x3/4 PHH PHMS SS
3 AS NOTED 93035846 CONN-WAGO 2-WIRE 222-412
2 1 - LED DRIVER STRAP ASSEMBLY
1 1 - LED RETRO-FIT OPTICAL ASSEMBLY
ITEM # QTY PART # DESCRIPTION NOTES
UPGRADE KIT CONTENTS
2
1
3
4
5
WARNING
: Fixtures must be grounded in accordance with local codes or the National Electrical
Code. Failure to do so may result in serious personal injury.
MAINTENANCE
: A regularly scheduled maintenance program should be established to retain optimum light
output and reduce heat retention. Dusting with a soft, clean, dry cloth is normally sufficient for the optics.
CAUTION
: All wiring must be done by a qualified electrician. KEEP THIS SHEET FOR FUTURE REFERENCE.
Examine all parts that are not intended to be replaced by the retrofit kit for damage and replace any damage
parts prior to installation of the retrofit.
!
ADD 4 MORE FOR
TRA59D / WMA59D
ARM OPTIONS ONLY
FOR TRA59U / WMA59U
ARM OPTIONS ONLY
6

LED Upgrade Kit Installation Guide
Fixture: PROS - Providence Small
A R C H I T E C T U R A L A R E A L I G H T I N G
93065348 REV A
PAGE 2/5
TM
www.aal.net
16555 East Gale Avenue
City of Industry, CA 91745
626.968.5666
STEPS: TO DIS-ASSEMBLE EXISTING ASSEMBLY:
1. Pull latch (as shown on the illustration) unplug all connectors,
remove guts and discard.
2. Rotate fitter cap counter clockwise, until free from fixture
(See fitter cap detail) unplug all connectors, remove guts
and discard.
TURN OFF ALL POWER TO THE UNIT AND TAKE PROPER SAFETY PRECAUTIONS. FAILURE TO
DO SO MAY RESULT IN SERIOUS PERSONAL INJURY.
!
PROS
POST TOP/TRA59U/WMA59U
UPWARD OPTIONS
PROS
TRA59D/WMA59D
DOWNWARD OPTIONS
LATCH
FITTER CAP
TABS
LATCH
FITTER CAP
TABS
CLOSED OPEN
FITTER CAP DETAIL
BALLAST
(REF)
G12 LAMP
(REF)
G12 LAMP
(REF)
BALLAST (REF)

LED Upgrade Kit Installation Guide
Fixture: PROS - Providence Small
A R C H I T E C T U R A L A R E A L I G H T I N G
93065348 REV A
PAGE 3/5
TM
www.aal.net
16555 East Gale Avenue
City of Industry, CA 91745
626.968.5666
STEPS: TO RETROFIT LED
1. Remove existing screws on each side as shown in location "A" and "B", assemble LED retro-fit optical assembly with
new produced two washers and two 10-24 x 3/4" screws provided by A.A.L. as shown on the illustrations below.
2. To assemble LED driver strap assembly, remove existing two 10-24 screws and assemble LED driver strap assembly
to fitter cap with same hardware as shown in the illustration below.
3. For wiring diagrams:
POST TOP MOUNT / TRA59U ARM / WMA59U ARM(UPWARD OPTIONS)
see page 4.
TRA59D ARM / WMA59D ARM (DOWNWARD OPTIONS)
see page 5.
4
.
Close top dome by snapping latch securely to bottom dome assembly, Place LED driver assembly carefully inside
fitter cap assembly rotate fitter cap clockwise until tabs snap securely into fitter.
5.
Retrofit installation complete.
ITEM#1
LED RETRO-FIT
OPTICAL ASSEMBLY
ITEM#4
2X A84252
SCR-10-24x3/4" PHH PHMS SS
ITEM#5
2X A84337
WSHR-N0. 10 SPLIT LK SS
DRAWING SHOWN
UPWARD OPTIONS
POST TOP MOUNT/TRA59U/WMA59U
(REFERENCE)
ITEM#2
LED DRIVER
STRAP ASSEMBLY
EXISTING
2X SCR-10-24X5/8
HARDWARE
FITTER CAP
TABS
LATCH
TOP DOME
ASSEMBLY
LOCATION "A"
LOCATION "B'
BOTTOM DOME
ASSEMBLY

LED Upgrade Kit Installation Guide
Fixture: PROS - Providence Small
A R C H I T E C T U R A L A R E A L I G H T I N G
93065348 REV A
PAGE 4/5
TM
www.aal.net
16555 East Gale Avenue
City of Industry, CA 91745
626.968.5666
WIRING DIAGRAM
POST TOP MOUNT/TRA59U/WMA59U
UPWARD OPTIONS
WMA59U ARM
OPTION
TRA59U ARM
OPTION
POST TOP MOUNT
OPTION
POLE
(REF)
BOND TO
BOTTOM DOME
BOND TO
FITTER
GROUND TO
FITTER
BOND TO
TOP DOME
ITEM#3
5X 93035846
CONN-WAGO
2-WIRE 222-412
LEAD WIRES
5 CABLE
CONDUCTOR
YELLOW/GREEN
BLUE GRAY BLACK
BROWN
YELLOW/GREEN
BROWN
GRAY
BLACK
BLUE
YELLOW (+)
BROWN (-)
GREEN
OSRAM OPTOTRONIC
OT50W/UNV
GRAY (-)
WHITE(+)
GREEN
PURPLE
GRAY
BLACK
WHITE
BLACK
WHITE
BLUE RED
ORANGE

LED Upgrade Kit Installation Guide
Fixture: PROS - Providence Small
A R C H I T E C T U R A L A R E A L I G H T I N G
93065348 REV A
PAGE 5/5
TM
www.aal.net
16555 East Gale Avenue
City of Industry, CA 91745
626.968.5666
WMA59D ARM
OPTION
TRA59D ARM
OPTION
POLE
(REF)
LEAD
WIRES
5 CABLE
CONDUCTOR
YELLOW/GREEN
BLUE
GRAY BLACK BROWN
YELLOW/GREEN
BLUE
ORANGE
PURPLE
BROWN GRAY
BLACK
BLUE
YELLOW (+)
BROWN (-)
GREEN
OSRAM OPTOTRONIC
OT50W/UNV
GRAY
RED
GRAY (-)
WHITE(+)
BLACK WHITE
GREEN
BLACK WHITE
5 CABLE
CONDUCTOR
GRAY
BLUE
BLUE GRAY
BOND TO
BOTTOM DOME
BOND TO
TOP DOME
BOND TO
FITTER
ITEM#3
9X CONN-WAGO
2-WIRE 222-412
NOTE:
USE TWO WIRES
FOR DIMMING OPTIONAL
GROUND TO
TOP DOME
WIRING DIAGRAM
TRA59D ARM / WMA59D ARM
DOWNWARD OPTIONS
(WITH TWO 5 CABLE CONDUCTOR)

INSTALLATION INSTRUCTIONS CATALOG NUMBER
PART NO.APPRVDDATE
DATE REV.
14249 Artesia Blvd. P.O. Box 1869
La Mirada, CA 90638-1869
(714)994-2700 fax(714)994-0522 A96482
PROS IND
WARNING: THIS PRODUCT CONTAINS CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS, AND/OR OTHE
R
REPRODUCTIVE HARM. THOROUGHLY WASH HANDS AFTER INSTALLING, HANDLING, CLEANING OR OTHERWISE TOUCHING THIS PRODUCT.
DOME
LATCH
INCOMING
WIRE LEADS
3.
2.
6.
5.
4.
1.
2.
5.
OPEN
1.
2.
3. SUPPLY.
6.
1.
3.
4.
LAMP (REFERENCE)
FITTER CAP
BALLAST
LAMP SERVICING:
TURN POWER OFF.
LATCH SECURELY.
TO RELEASE BALLAST,
BALLAST SERVICING:
TURN POWER OFF.
SERVICE BALLAST.
3" O.D. POLE (REF)
WIRE CONNECTIONS
(BY OTHERS)
8-32 X 1/4"
(2) P/N A84031
PHMS S/S
(3) P/N 93007472
SET SCREW S/S
5/16-18 X 1/4"
TURN OFF POWER.
INSTALLATION STEPS:
CLOSED
(BY OTHERS)
CONNECTORS
CAREFULLY PLACE FITTER CAP INTO FITTER,
LAMP SERVICING COMPLETE.
SNAP SECURELY INTO FITTER.
ROTATE FITTER CAP CLOCKWISE UNTIL TABS
PLUG IN ALL CONNECTORS, RE-INSTALL BALLAST
UNPLUG ALL CONNECTORS AND REMOVE (2) SCREWS
AND SECURE WITH (2) SCREWS. CLOSE DOME AND
BALLAST SERVICING COMPLETE.
LIFT FITTER CAP WITH REFLECTOR FROM FITTER.
ROTATE FITTER CAP COUNTER CLOCKWISE, UNTIL
FREE FROM FIXTURE. (SEE FITTER CAP DETAIL)
PULL LATCH AND RAISE DOME TO ACCESS BALLAST.
BE GROUNDED TO THE INCOMING EQUIPMENT GROUND
WITH (3) 5/16-18 x 1/4" SET SCREWS.
INSTALLATION COMPLETE.
MAKE WIRE CONNECTIONS FROM INCOMING WIRE LEADS
FITTER CAP DETAIL
TO ARM LEADS, AS SHOWN. (WHITE TO COMMON, BLACK 4. INSTALL LAMP (BY OTHERS).
FIXTURE
SLIP FIXTURE OVER POLE, AND SECURE FIXTURE TO POLE
TO HOT AND GREEN TO GROUND). NOTE: ASSEMBLY MUST
TABS
12
2
1

INSTALLATION INSTRUCTIONS CATALOG NUMBER
PART NO.APPRVDDATE
DATE REV.
14249 Artesia Blvd. P.O. Box 1869
La Mirada, CA 90638-1869
(714)994-2700 fax(714)994-0522 A96483
PROS IND
WARNING: THIS PRODUCT CONTAINS CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS, AND/OR OTHE
R
REPRODUCTIVE HARM. THOROUGHLY WASH HANDS AFTER INSTALLING, HANDLING, CLEANING OR OTHERWISE TOUCHING THIS PRODUCT.
Date
TRA59U
CLOSED
ARM
1.
TENON
DOME
(BY OTHERS)
6.
5.
3.
1.
2.
6.
4.
3.
5.
4.
2.
1.
4.
5.
3.
BALLAST
LATCH
TURN POWER OFF.
BALLAST SERVICING:
OPEN
MOUNTING PLATE
(ORIENTATION)
WIRE CONNECTIONS
(HARDWARE AS NOTED).
TURN OFF POWER.
INSTALLATIONSTEPS:
TURN POWER OFF.
LAMP SERVICING:
TO RELEASE BALLAST,
LATCH SECURELY.
FITTER CAP DETAIL
LAMP (REFERENCE)
(BY OTHERS)
FITTER CAP
INCOMING WIRE LEADS
4" O.D. POLE (REF)
CAREFULLY PLACE FITTER CAP INTO FITTER,
INSTALL LAMP (BY OTHERS).
LIFT FITTER CAP FROM FITTER.
ROTATE FITTER CAP COUNTER CLOCKWISE, UNTIL
INSTALLATION COMPLETE.
3/8-16 X 1" LG
(2) P/N A84186
SHCS S/S
LAMP SERVICING COMPLETE.
SNAP SECURELY INTO FITTER.
FREE FROM FIXTURE. (SEE FITTER CAP DETAIL)
PLUG IN ALL CONNECTORS, RE-INSTALL BALLAST
UNPLUG ALL CONNECTORS AND REMOVE (2) SCREWS
SERVICE BALLAST ASSEMBLY.
AND SECURE WITH (2) SCREWS. CLOSE DOME AND
BALLAST SERVICING COMPLETE.
ROTATE FITTER CAP CLOCKWISE UNTIL TABS
5/16-18 X 1/4"
(3) P/N 93007472
SET SCREW S/S
COMMON, BLACK TO HOT AND GREEN TO GROUND).
NOTE: ASSEMBLY MUST BE GROUNDED TO THE
INCOMING EQUIPMENT GROUND SUPPLY.
PLACE WIRING IN POLE AND SECURE ARM TO POLE
SLIP FIXTURE OVER ARM, AND SECURE FIXTURE
TO ARM WITH (3) 5/16-18 x 1/4" SET SCREWS.
MOUNTING HARDWARE
FOR POLE BY AAL,
FOR POLE BY OTHERS,
MAKE WIRE CONNECTIONS FROM INCOMING WIRE
HARDWARE BY OTHERS.
LEADS TO ARM LEADS, AS SHOWN. (WHITE TO
HARDWARE INCLUDED.
TABS
CONNECTORS
PHMS S/S
8-32 X 1/4"
(2) P/N A84031
PULL LATCH AND RAISE DOME TO ACCESS BALLAST.2.
2
1
3
123
WIREWAY
2.50
10.0
(2) 7/16"
CLEARANCE


INSTALLATION INSTRUCTIONS CATALOG NUMBER
PART NO.APPRVDDATE
DATE REV.
14249 Artesia Blvd. P.O. Box 1869
La Mirada, CA 90638-1869
(714)994-2700 fax(714)994-0522 A96485
PROS DIR
WARNING: THIS PRODUCT CONTAINS CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS, AND/OR OTHE
R
REPRODUCTIVE HARM. THOROUGHLY WASH HANDS AFTER INSTALLING, HANDLING, CLEANING OR OTHERWISE TOUCHING THIS PRODUCT.
TRA59D
(ORIENTATION)
SHCS S/S
CONNECTORS
4" O.D. POLE (REF)
INCOMING
WIRE LEADS
FIXTURE
FIXTURE
FRONT OF
DOME
ARM
LATCH
CAPTIVE SCREWS
OPEN
CLOSED
CONNECTORS
1.
3.
4.
2.
6.
7.
5.
TURN POWER OFF.
3.
1.
2.
LAMP SERVICING:
2.
3.
4.
TURN OFF POWER.1.
CAPTIVE
SCREWS
BALLAST INTO FITTER.
SECURELY INTO FITTER.
BALLAST SERVICING:
LIFT FITTER CAP WITH BALLAST FROM FITTER AND
ROTATE FITTER CAP COUNTER CLOCKWISE, UNTIL
UNPLUG ALL CONNECTORS.
FREE FROM FIXTURE. (SEE FITTER CAP DETAIL)
PULL LATCH AND LOWER FIXTURE, AS SHOWN.
INSTALL LAMP (BY OTHERS). AND
CLOSE FIXTURE AND LATCH SECURELY.
LAMP SERVICING COMPLETE.
DOME DETAIL
MOUNTING PATTERN
5.
6.
3/8-16 X 1" LG
(2) P/N A84186
LEADS TO ARM LEADS, AS SHOWN. (WHITE TO
4. SERVICE BALLAST.
FITTER CAP DETAIL
PLACE WIRING IN POLE AND SECURE FIXTURE
TO POLE (HARDWARE AS NOTED).
INSTALLATION COMPLETE.
NOTE: ASSEMBLY MUST BE GROUNDED TO THE
INCOMING EQUIPMENT GROUND SUPPLY.
TURN OFF POWER.
INSTALLATION STEPS:
(AS SHOWN), CLOSE BALLAST COMPARTMENT.
PLUG IN CONNECTORS FROM ARM TO FIXTURE.
MAKE WIRE CONNECTIONS FROM INCOMING WIRE
PLUG IN ALL CONNECTORS AND CAREFULLY PLACE
ROTATE FITTER CAP CLOCKWISE, UNTIL TABS SNAP
BALLAST SERVICING COMPLETE.
FITTER CAP
BALLAST
TABS
ASSEMBLE FIXTURE TO ARM WITH (2) CAPTIVE SCREWS
PULL LATCH AND LOWER FIXTURE TO ACCESS BALLAST;
COMMON, BLACK TO HOT AND GREEN TO GROUND).
WIRE
CONNECTIONS
(BY OTHERS)
LAMP (REFERENCE)
(BY OTHERS)
SAFETY CALBE
MOUNTING HARDWARE
FOR POLE BY AAL,
FOR POLE BY OTHERS,
HARDWARE BY OTHERS.
HARDWARE INCLUDED.
3.5
10.00
WIREWAY
(2) O7/16"
CLEARANCE 1
1

INSTALLATION INSTRUCTIONS CATALOG NUMBER
PART NO.APPRVDDATE
DATE REV.
14249 Artesia Blvd. P.O. Box 1869
La Mirada, CA 90638-1869
(714)994-2700 fax(714)994-0522 A96486
PROS DIR
WARNING: THIS PRODUCT CONTAINS CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS, AND/OR OTHE
R
REPRODUCTIVE HARM. THOROUGHLY WASH HANDS AFTER INSTALLING, HANDLING, CLEANING OR OTHERWISE TOUCHING THIS PRODUCT.
TRA59U
LATCH
CLOSED
TENON
FIXTURE
(BY OTHERS)
CONNECTORS
DOME
4" O.D. POLE (REF)
TABS
BALLAST
FITTER CAP
(ORIENTATION)
2.
2.
4. SERVICE BALLAST.
LAMP SERVICING:
MOUNTING HARDWARE
FOR POLE BY AAL,
FOR POLE BY OTHERS,
HARDWARE BY OTHERS.
HARDWARE INCLUDED.
OPEN
SHCS S/S
3.
4.
TURN OFF POWER.1.
TURN POWER OFF.
3.
1.
3/8-16 X 1" LG
(
2
)
P/N A84186
6.
7.
(BY OTHERS)
5/16-18 X 1/4"
(3) P/N 93007472
SET SCREW S/S
1.
2.
3.
5.
4.
CONNECTORS
LAMP (REFERENCE)
FITTER CAP DETAIL
INCOMING EQUIPMENT GROUND SUPPLY.
PLACE WIRING IN POLE AND SECURE ARM TO POLE
ROTATE FITTER CAP CLOCKWISE, UNTIL TABS SNAP
BALLAST SERVICING COMPLETE.
BALLAST INTO FITTER.
SECURELY INTO FITTER.
ROTATE FITTER CAP COUNTER CLOCKWISE, UNTIL
UNPLUG ALL CONNECTORS.
BALLAST SERVICING:
LIFT FITTER CAP WITH BALLAST FROM FITTER AND
FREE FROM FIXTURE. (SEE FITTER CAP DETAIL)
CLOSE DOME AND LATCH SECURELY.
LAMP SERVICING COMPLETE.
PULL LATCH AND RAISE DOME AS SHOWN.
INSTALL LAMP (BY OTHERS). AND
MOUNTING HOLES
PLUG IN CONNECTORS FROM ARM TO FIXTURE AND
TO TENON WITH (3) 5/16-18 x 1/4" SET SCREWS.
SLIP FIXTURE OVER TENON, AND SECURE FIXTURE
INSTALLATION COMPLETE.
LEADS TO ARM LEADS, AS SHOWN. (WHITE TO
NOTE: ASSEMBLY MUST BE GROUNDED TO THE
TURN OFF POWER.
INSTALLATION STEPS:
MAKE WIRE CONNECTIONS FROM INCOMING WIRE
(HARDWARE AS NOTED). PLUG IN ALL CONNECTORS AND CAREFULLY PLACE5.
INCOMING WIRE LEADS
COMMON, BLACK TO HOT AND GREEN TO GROUND).
WIRE CONNECTIONS
ARM
3.5
10.00
WIREWAY
(2) O7/16"
CLEARANCE
2
12
1

INSTALLATION INSTRUCTIONS CATALOG NUMBER
PART NO.APPRVDDATE
DATE REV.
14249 Artesia Blvd. P.O. Box 1869
La Mirada, CA 90638-1869
(714)994-2700 fax(714)994-0522 A96487
PROS DIR
WARNING: THIS PRODUCT CONTAINS CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS, AND/OR OTHE
R
REPRODUCTIVE HARM. THOROUGHLY WASH HANDS AFTER INSTALLING, HANDLING, CLEANING OR OTHERWISE TOUCHING THIS PRODUCT.
WMA59D
(BY OTHERS)
WIRE CONNECTIONS
SILICONE
(BY OTHERS)
SCREWS
CAPTIVE
DOME DETAIL
FITTER CAP
SCREWS
FIXTURE
DOME
FIXTURE
SECURELY INTO FITTER.
BALLAST INTO FITTER.
7.
6.
UNPLUG ALL CONNECTORS.
5. SERVICE BALLAST.4.
2.
1.
3.
TURN POWER OFF.
BALLAST SERVICING:
LATCH SECURELY.
1. TURN OFF POWER.
4.
3.
LAMP SERVICING COMPLETE.
2.
LAMP SERVICING:
TABS
BALLAST
4.
INSTALLATION STEPS:
1. TURN OFF POWER.
2.
CONNECTORS
CLOSED
HARDWARE BY OTHERS).
INSTALLATION COMPLETE.7.
6. SURFACE AS SHOWN.
5.
WIRE LEADS
INCOMING
FRONT OF
ARM
MOUNTING HARDWARE
CONNECTORS
(BY OTHERS)
MOUNTING PLATE
BALLAST SERVICING COMPLETE.
INSTALL LAMP (BY OTHERS). CLOSE FIXTURE AND
PULL LATCH AND LOWER FIXTURE, AS SHOWN.
(ORIENTATION)
MOUNTING PLATE
PLACE WIRING IN J-BOX AND MOUNT FIXTURE
INCOMING EQUIPMENT GROUND SUPPLY.
FITTER CAP DETAIL
PLUG IN CONNECTORS FROM FIXTURE TO ARM.
ROTATE FITTER CAP CLOCKWISE, UNTIL TABS SNAP
PLUG IN ALL CONNECTORS AND CAREFULLY PLACE
ROTATE FITTER CAP COUNTER CLOCKWISE, UNTIL
LIFT FITTER CAP WITH BALLAST FROM FITTER AND
FREE FROM FIXTURE. (SEE FITTER CAP DETAIL)
JUNCTION BOX
OPEN
NOTE: ASSEMBLY MUST BE GROUNDED TO THE
COMMON, BLACK TO HOT AND GREEN TO GROUND).
LEADS TO ARM LEADS, AS SHOWN. (WHITE TO
MAKE WIRE CONNECTIONS FROM INCOMING WIRE
FIXTURE TO ARM WITH (2) CAPTIVE SCREWS (AS SHOWN),
INSTALL LAMP. CLOSE LAMP COMPARTMENT.
SILICONE AROUND MOUNTING PLATE AND MOUNTING
TO WALL. (NOT FOR JUNCTION BOX MOUNTING,
3. PULL LATCH AND RAISE DOME AS SHOWN; ASSEMBLE
(2)CAPTIVE
CONNECTORS
SAFETY CABLE
LATCH
(BY OTHERS)
LAMP (REFERENCE)
3.5
10.00
O1 1/2"
13.94
5.0
WIREWAY
(2) O7/16"
CLEARANCE

INSTALLATION INSTRUCTIONS CATALOG NUMBER
PART NO.APPRVDDATE
DATE REV.
14249 Artesia Blvd. P.O. Box 1869
La Mirada, CA 90638-1869
(714)994-2700 fax(714)994-0522 A96488
PROS DIR
WARNING: THIS PRODUCT CONTAINS CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS, AND/OR OTHE
R
REPRODUCTIVE HARM. THOROUGHLY WASH HANDS AFTER INSTALLING, HANDLING, CLEANING OR OTHERWISE TOUCHING THIS PRODUCT.
WMA59U
LATCH
(BY OTHERS)
ARM
DOME
FITTER CAP
CONNECTORS
BALLAST
TABS
JUNCTION BOX
(BY OTHERS)
INCOMING WIRE LEADS
(ORIENTATION)
WIRE CONNECTIONS
4. SERVICE BALLAST.
5.
6.
7.
BALLAST INTO FITTER.
TURN POWER OFF.
3.
1.
2.
4.
BALLAST SERVICING:
LAMP SERVICING:
2.
3.
TURN OFF POWER.1.
MOUNTING HARDWARE
(BY OTHERS)
CLOSED OPEN
5.
6. INSTALLATION COMPLETE.
SURFACE, AS SHOWN.
4.
3.
1. INSTALLATION STEPS:
2. TURN OFF POWER.
MOUNTING PLATE
(BY OTHERS) TENON
LAMP (REFERENCE)
CONNECTORS
SILICONE
MOUNTING PLATE
FITTER CAP DETAIL
CLOSE DOME AND LATCH SECURELY.
LAMP SERVICING COMPLETE.
RAISE FIXTURE DOME AS SHOWN.
FREE FROM FIXTURE. (SEE FITTER CAP DETAIL)
COMMON, BLACK TO HOT AND GREEN TO GROUND).
NOTE: ASSEMBLY MUST BE GROUNDED TO THE
INCOMING EQUIPMENT GROUND SUPPLY.
BALLAST SERVICING COMPLETE.
SECURELY INTO FITTER.
PLUG IN ALL CONNECTORS AND CAREFULLY PLACE
ROTATE FITTER CAP CLOCKWISE, UNTIL TABS SNAP
PULL LATCH AND RAISE DOME AS SHOWN.
INSTALL LAMP (BY OTHERS). AND
LIFT FITTER CAP WITH BALLAST FROM FITTER AND
ROTATE FITTER CAP COUNTER CLOCKWISE, UNTIL
UNPLUG ALL CONNECTORS.
SLIP FIXTURE OVER TENON, AND SECURE FIXTURE
TO TENON WITH (3) 5/16-18 x 1/4" SET SCREWS.
SILICONE AROUND MOUNTING PLATE AND MOUNTING
PLUG IN CONNECTORS FROM ARM TO FIXTURE.
MAKE WIRE CONNECTIONS FROM INCOMING WIRE
LEADS TO ARM LEADS, AS SHOWN. (WHITE TO
PLACE WIRING IN J-BOX AND MOUNT FIXTURE TO
MOUNTING SURFACE. (NOT FOR JUNCTION BOX
FIXTURE
MOUNTING, HARDWARE BY OTHERS).
(3) P/N 93007472
SET SCREW S/S
5/16-18 X 1/4"
1
1
3.5
10.00
5.0
13.94
WIREWAY
(2) O7/16"
CLEARANCE

INSTALLATION INSTRUCTIONS CATALOG NUMBER
PART NO.APPRVDDATE
DATE REV.
14249 Artesia Blvd. P.O. Box 1869
La Mirada, CA 90638-1869
(714)994-2700 fax(714)994-0522 A96489
PROS DIR
WARNING: THIS PRODUCT CONTAINS CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS, AND/OR OTHE
R
REPRODUCTIVE HARM. THOROUGHLY WASH HANDS AFTER INSTALLING, HANDLING, CLEANING OR OTHERWISE TOUCHING THIS PRODUCT.
WIRE LEADS
INCOMING
FIXTURE
DOME
(BY OTHERS)
LAMP (REFERENCE)
LATCH
TABS
FITTER CAP
CONNECTORS
(BY OTHERS)
WIRE CONNECTIONS
BALLAST
3" O.D. POLE
2.
GROUND SUPPLY.
3.
INSTALLATION STEPS:
1. TURN OFF POWER.
1.
4.
3.
2.
LAMP SERVICING:
CLOSED OPEN
SECURELY INTO FITTER.
BALLAST INTO FITTER.
5. SERVICE BALLAST.4.
7.
6.
3.
TURN POWER OFF.
BALLAST SERVICING:
1.
2.
4.
FITTER CAP DETAIL
BALLAST SERVICING COMPLETE.
ROTATE FITTER CAP CLOCKWISE, UNTIL TABS SNAP
PLUG IN ALL CONNECTORS AND CAREFULLY PLACE
MAKE WIRE CONNECTIONS FROM INCOMING WIRE
LEADS TO FIXTURE. (WHITE TO COMMON, BLACK
TO HOT AND GREEN TO GROUND). NOTE: ASSEMBLY
MUST BE GROUNDED TO THE INCOMING EQUIPMENT
FREE FROM FIXTURE. (SEE FITTER CAP DETAIL)
UNPLUG ALL CONNECTORS.
ROTATE FITTER CAP COUNTER CLOCKWISE, UNTIL
LIFT FITTER CAP WITH BALLAST FROM FITTER AND
POLE WITH (3) 5/16-18 x 1/4" SET SCREWS.
SLIP FIXTURE OVER POLE, AND SECURE FIXTURE TO
INSTALLATION COMPLETE.
TURN OFF POWER.
LAMP SERVICING COMPLETE.
CLOSE DOME AND LATCH SECURELY.
INSTALL LAMP (BY OTHERS). AND
PULL LATCH AND RAISE DOME AS SHOWN.
SET SCREW S/S
(3) P/N 93007472
5/16-18 X 1/4"
1
1

INSTALLATION INSTRUCTIONS CATALOG NUMBER
PART NO.APPRVDDATE
DATE REV.
14249 Artesia Blvd. P.O. Box 1869
La Mirada, CA 90638-1869
(714)994-2700 fax(714)994-0522 A96490
PROS IND
WARNING: THIS PRODUCT CONTAINS CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS, AND/OR OTHE
R
REPRODUCTIVE HARM. THOROUGHLY WASH HANDS AFTER INSTALLING, HANDLING, CLEANING OR OTHERWISE TOUCHING THIS PRODUCT.
TRA59D
3.
5.
2.
1.
4.
TURN POWER OFF.
BALLAST SERVICING:
2.
1. TURN POWER OFF.
LAMP SERVICING:
6. LATCH SECURELY.
TO RELEASE BALLAST,
SERVICE BALLAST.
SHCS S/S
(2) P/N A84186
3/8-16 X 1" LG
6.
PHMS S/S
2.
4.
3.
1. TURN OFF POWER.
5.
4.
(2) P/N A84031
8-32 X 1/4"
6.
5.
WIRE LEADS
INCOMING
WIRE
(REFERENCE)
4" O.D. POLE
CONNECTORS
ARM
CONNECTORS
LATCH
BALLAST
FITTER CAP
DOME
(ORIENTATION)
SCREWS
CAPTIVE
FIXTURE
FRONT OF
FIXTURE
(BY OTHERS)
CAREFULLY PLACE FITTER CAP ASSEMBLY INTO
INSTALL LAMP (BY OTHERS).
ROTATE FITTER CAP COUNTER CLOCKWISE, UNTIL
BALLAST SERVICING COMPLETE.
UNPLUG ALL CONNECTORS AND REMOVE (2) SCREWS
PLUG IN ALL CONNECTORS, RE-INSTALL BALLAST
PULL LATCH AND LOWER FIXTURE TO ACCESS BALLAST.
FREE FROM FIXTURE. (SEE FITTER CAP DETAIL)
AND SECURE WITH (2) SCREWS. CLOSE FIXTURE
DOME DETAIL
CLOSED OPEN
INCOMING EQUIPMENT GROUND SUPPLY.
NOTE: ASSEMBLY MUST BE GROUNDED TO THE
COMMON, BLACK TO HOT AND GREEN TO GROUND).
INSTALLATION COMPLETE.
TO POLE (HARDWARE AS NOTED).
PLACE WIRING IN POLE AND SECURE FIXTURE
INSTALLATIONSTEPS:
MAKE WIRE CONNECTIONS FROM INCOMING WIRE
PLUG IN CONNECTORS FROM ARM TO FIXTURE.
(AS SHOWN), CLOSE BALLAST COMPARTMENT.
FITTER, ROTATE FITTER CAP CLOCKWISE UNTIL TABS
SNAP SECURELY INTO FITTER.
LAMP SERVICING COMPLETE.
FITTER CAP DETAIL
LEADS TO ARM LEADS, AS SHOWN. (WHITE TO 3. LIFT FITTER CAP FROM FITTER.
MOUNTING PATTERN
PULL LATCH AND LOWER FIXTURE TO ACCESS BALLAST;
ASSEMBLE FIXTURE TO ARM WITH (2) CAPTIVE SCREWS
CAPTIVE SCREWS
LAMP (REFERENCE)
TABS
HARDWARE INCLUDED.
HARDWARE BY OTHERS.
FOR POLE BY OTHERS,
FOR POLE BY AAL,
MOUNTING HARDWARE
(BY OTHERS)
CONNECTIONS
1
2
12
3.5
10.00
WIREWAY
(2) O7/16"
CLEARANCE

INSTALLATION INSTRUCTIONS CATALOG NUMBER
PART NO.APPRVDDATE
DATE REV.
14249 Artesia Blvd. P.O. Box 1869
La Mirada, CA 90638-1869
(714)994-2700 fax(714)994-0522 A96491
PROS IND
WARNING: THIS PRODUCT CONTAINS CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS, AND/OR OTHE
R
REPRODUCTIVE HARM. THOROUGHLY WASH HANDS AFTER INSTALLING, HANDLING, CLEANING OR OTHERWISE TOUCHING THIS PRODUCT.
TRA59D
(BY OTHERS)
(BY OTHERS)
TABS
FITTER CAP CLOSED
ARM
DOME
FIXTURE
6.
4.
5.
2.
1.
6.
3.
4.
1.
3.
1.
7.
5.
6.
2.
WIRE LEADS
INCOMING
4.
2.
(BY OTHERS)
JUNCTION BOX
MOUNTING PLATE
SILICONE
CONNECTORS
BALLAST
LATCH
CONNECTORS
OPEN
(ORIENTATION)
MOUNTING PLATE
SCREWS
(2)CAPTIVE
TURN POWER OFF.
LAMP SERVICING:
TO RELEASE BALLAST.
SERVICE BALLAST.
TURN POWER OFF.
BALLAST SERVICING:
FIXTURE
SURFACE, AS SHOWN.
INSTALLATION STEPS:
DOME DETAIL
TURN OFF POWER.
(BY OTHERS)
INTO FITTER.
LATCH SECURELY.
MOUNTING HARDWARE
5.
FRONT OF
(2)CAPTIVE SCREWS
PULL LATCH AND LOWER FIXTURE TO ACCESS BALLAST.
FREE FROM FIXTURE. (SEE FITTER CAP DETAIL)
ROTATE FITTER CAP COUNTER CLOCKWISE, UNTIL
MOUNTING, HARDWARE BY OTHERS).
MOUNTING SURFACE. (NOT FOR JUNCTION BOX
PLACE WIRING IN J-BOX AND MOUNT FIXTURE TO
INSTALLATION COMPLETE.
SILICONE AROUND MOUNTING PLATE AND MOUNTING
MAKE WIRE CONNECTIONS FROM INCOMING WIRE
PLUG IN CONNECTORS FROM ARM TO FIXTURE.
PULL LATCH AND LOWER FIXTURE TO ACCESS BALLAST;
ASSEMBLE FIXTURE TO ARM WITH (2) CAPTIVE SCREWS
(AS SHOWN), CLOSE LAMP COMPARTMENT.
INCOMING EQUIPMENT GROUND SUPPLY.
NOTE: ASSEMBLY MUST BE GROUNDED TO THE
COMMON, BLACK TO HOT AND GREEN TO GROUND).
LEADS TO ARM LEADS, AS SHOWN. (WHITE TO
FITTER CAP CLOCKWISE UNTIL TABS SNAP SECURELY
LAMP SERVICING COMPLETE.
CAREFULLY PLACE FITTER CAP INTO FITTER, ROTATE
INSTALL LAMP (BY OTHERS).
BALLAST SERVICING COMPLETE.
AND SECURE WITH (2) SCREWS. CLOSE FIXTURE AND
UNPLUG ALL CONNECTORS AND REMOVE (2) SCREWS
PLUG IN ALL CONNECTORS, RE-INSTALL BALLAST
3. LIFT FITTER CAP FROM FITTER.
WIRE CONNECTIONS
8-32 X 1/4"
PHMS S/S
(2) P/N A84031
LAMP (REFERENCE)
FITTER CAP DETAIL
1
1
3.5
10.00
O1 1/2"
5.0
13.94
WIREWAY
(2) O7/16"
CLEARANCE
Table of contents
Other Architectural Area Lighting Outdoor Light manuals

Architectural Area Lighting
Architectural Area Lighting SC5 Service manual

Architectural Area Lighting
Architectural Area Lighting Y-LED User manual

Architectural Area Lighting
Architectural Area Lighting MicroCore User manual

Architectural Area Lighting
Architectural Area Lighting Towne Commons ALN540 User manual