3
EN
COOLING
OUTDOOR TEMPERATURE 43°C D.B.
ROOM TEMPERATURE 32°C D.B./23°C W.B.
OUTDOOR TEMPERATURE -15°C D.B.
ROOM TEMPERATURE 10°C D.B./6°C W.B.
HEATING
OUTDOOR TEMPERATURE 24°C D.B./18°C W.B.
ROOM TEMPERATURE 27°C D.B.
OUTDOOR TEMPERATURE -15°C D.B.
INDOOR ROOM 10°C D.B.
MAxIMUM CONDITIONS
MINIMUM CONDITIONS
MAxIMUM CONDITIONS
MINIMUM CONDITIONS
OPERATING LIMITS
•Supplytheunitwithadedicatedelectricalline.
•Makeinstalltheunitbyqualifiedpersonnel.
•Beforeinstallation,checkthatthevoltageoftheelectricsupplyinyourhomeorofficeisthesameasthevoltage
shown on the nameplate.
•Theinstallationofadouble-poleswitch,protectedby10Afusesofthedelayedtype,upstreamtheelectricitywall
socket, is recommended.
•Makesurethatcircuitbreakers,fuses,etc,areofsufficientcapacitytohandleastart-upcurrentof20A(generallyless
then 1 second) - ONLY FOR ON/FF VERSION
•WARNING!
The air conditioner is provided with a time-guard system, which does not allow re-starting of compressor until after 3
minutes from a previous stop.
If necessary, get help
These instructions are all you need for most installation sites and maintenance conditions.
Ifyourequirehelpforaspecialproblem,contactoursale/serviceoutletoryourcertifieddealerforadditionalinstructions.
In case of improper installation
The manufacturer shall in no way be responsible for improper installation or maintenance service, including failure to
follow the instructions in this document.
ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH.
ONLY QUALIFIED, ExPERIENCED ELECTRICIANS SHOULD ATTEMPT TO WIRE THIS SYSTEM.
•Donotsupplypowertotheunituntilallwiringarecompletedorreconnectedandchecked,toensurethegrounding.
•Highlydangerouselectricalvoltagesareusedinthissystem.Carefullyrefertothewiringdiagramandtheseinstructions
when wiring.
Improperconnectionsandinadequategroundingcancauseaccidentalinjuryanddeath.
•Ground the unit following local electrical codes.
•TheYellow/Greenwirecannotbeusedforanyconnectiondifferentfromthegroundconnection.
•Connectallwiringtightly.Loosewiringmaycauseoverheatingatconnectionpointsandapossiblefirehazard.
•Donotallowwiringtotouchtherefrigeranttubing,compressor,oranymovingpartsofthefan.
•Donotusemulticorecablewhenwiringthepowersupplyandcontrollines.Useseparatecablesforeachtypeofline.
When transporting
Be careful when picking up and moving the unit. Get a partner to help, and bend your knees when lifting to reduce strain
on your back. Sharp edges or thin aluminium fins on the unit can cut your fingers.
Move the unit only after removing the front panel and the bottom panel.
When installing
Make sure the wall is strong enough to hold the unit weight. It may be necessary to build a strong wooden or metal
frame to provide added support.
Donotmountthefrontpaneland/orthebottompanelbeforefixingtheunittothewall.
When wiring
WARNING
1 - GENERALITIES
OPERATING CONDITIONS SPECIAL PRECAUTIONS
•Cleanonlywithneutraldetergents.
•Donotplaceobjectsontheunit.
•Donotpourliquidsontheunit.