Aries Portable Spa User manual

ARIES SPAS
BY ARIES ACRYLIC MFG., INC.
OWNER'S MANUAL

BY ARIES ACRYLIC MANUFACTURING, INC. 4176 I-30 EAST ROCKWALL, TEXAS 75087
ARIES SPAS
ARIES SPAS
OWNER'S MANUAL
Copyright © 2005 Aries Acrylic Mfg., Inc.
4176 I-30 East
Rockwall, Texas 75087 • (972) 771-6286
Printed in the USA

Aries Spas • User Manual
ii
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
• WARNING-Toreducetheriskofinjury,donotpermit
childrentousethisproductunlesstheyarecloselysupervised
atalltimes.
• Awireconnectorisprovidedonthisunittoconnectamini-
mumNo.8AWG(8.4mm2)solidcopperconductorbetween
thisunitandanymetalequipment,metalenclosuresofelectri-
calequipment,metalwaterpipe,orconduitwithin5feet(1.5
m)oftheunit.
• WARNING-Thisproductisprovidedwithaground-fault
circuit-interrupteronthesideofthecontrolbox(beneaththe
spa).TheGFCImustbetestedbeforeeachuse.Withtheprod-
uctoperating,opentheservicedoor.Iftheproductstopsoper-
ating,thismerelyindicatesthatthedoorisequippedwithan
electricalinterlock.Next,pushthetestbuttonontheGFCIand
closetheservicedoor.Theproductshouldnotoperate.Now,
opentheservicedoor,pushtheresetbuttonontheGFCIand
closetheservicedoor.Theproductshouldnowoperatenor-
mally.Iftheproductfailstooperateinthismanner,thereisa
groundcurrentowingindicatingthepossibilityofanelectric
shock.Disconnectthepoweruntilthefaulthasbeenidentied
andcorrected.

Aries Spas • User Manual
• DANGER-RiskofAccidentalDrowning.Extremecaution
mustbeexercisedtopreventunauthorizedaccessbychildren.
Toavoidaccidents,ensurethatchildrencannotusethisspaun-
lesstheyaresupervisedatalltimes.
• DANGER-Riskofinjury.Thesuctionttingsinthisspa
aresizedtomatchthespecicwaterowcreatedbythepump.
Shouldtheneedarisetoreplacethesuctionttingsorthe
pump,besurethattheowratesarecompatible.
• DANGER-RiskofElectricShock.Installatleast5feet
(1.5m)fromallmetalsurfaces.Asanalternative,aspamaybe
installedwithin5feetofmetalsurfacesifeachmetalsurfaceis
permanentlyconnectedbyaminimumNo.8AWG(8.4mm2)
solidcopperconductortothewireconnectorontheterminal
boxthatisprovidedforthispurpose.
• DANGER-RiskofElectricShock.Donotpermitanyelec-
tricappliance,suchasalight,telephone,radio,television,
within5feet(1.5M)ofaspa.
• WARNING-Toreducetheriskofinjury:
• Thewaterinthespashouldneverexceed40˚C(104˚
F).Watertemperaturesbetween38˚C(100˚F)and40˚C
areconsideredsafeforahealthyadult.Lowerwatertem-
peraturesarerecommendedforyoungchildrenandwhen
spauseexceeds10minutes.

Aries Spas • User Manual
iv
• Sinceexcessivewatertemperatureshaveahighpo-
tentialforcausingfetaldamageduringtheearlymonthsof
pregnancy,pregnantorpossiblypregnantwomenshouldn't
limitspawatertemperaturesto100˚F(38˚C).
• Beforeenteringaspa,theusershouldmeasurethe
watertemperaturewithanaccuratethermometersincethe
toleranceofwatertemperature-regulatingdevicesvaries.
• Theuseofalcohol,drugs,ormedicationbeforeor
duringspausemayleadtounconsciousnesswiththepos-
sibilityofdrowning.
• Personssufferingfromobesityorwithamedicalhis-
toryofheartdisease,loworhighbloodpressure,circulato-
rysystemproblems,ordiabetesshouldconsultaphysician
beforeusingaspa.
• Personsusingmedicationshouldconsultaphysician
beforeusingaspasincesomemedicationsmayaffectheart
rate,bloodpressure,andcirculation.
SAVE THESE INSTRUCTIONS.

Aries Spas • User Manual
About this manual
Thisbookletwasdesignedtobeanaidinunderstanding
theoperation,functions,andmaintenanceofyourAries
Spa.
ToreceivemaximumpleasurefromyourAriesSpa,itis
helpfultounderstandhowthespaoperatesandtohave
knowledgeofpropermaintenanceprocedures.
Differentapplicationsandinstallationsrequirevarious
typesofequipment.Ifyourequipmentisdifferentfrom
thatdescribedinthismanual,itmaybenecessarytorefer
toanymanualssuppliedbyyourequipmentmanufacturer
forspecicoperatingandinstallationinformation.
Wehopethatthismanualwillgiveyoualltheinformation
neededtounderstandthebasicsofoperationandmain-
tenanceofyourspa.Ifyouhavequestionsthatwerenot
answeredinthisbooklet,pleasegiveusacall.
Enjoy,
ThestaffatAriesSpas

Aries Spas • User Manual
vi
Contents
Important Safety Instructions ............................................ii
About this manual ........................................................... v
Installation ...................................................................... 1
Electrical Hookup........................................................ 1
Replacement of Existing Equipment ............................ 2
Location..................................................................... 2
Operation ....................................................................... 3
Initial Start-up ............................................................ 3
Filling your Spa .......................................................... 3
Starting your Circulating Pump .................................... 3
Equipment Pack Controls ................................................. 5
Power Switch (GFCI)................................................... 5
GFCI Breaker “Test” and “Reset” Buttons..................... 5
Spa-Side Controls............................................................ 6
Settin the Desired Temperature ................................... 6
Digital Temperature Readout ....................................... 7
Increase / Decrease Arrows......................................... 7
Function Buttons........................................................ 7
Jet Button .............................................................. 7
AUX Button............................................................. 8
Light Button ............................................................ 8
Display Inversion ..................................................... 9
L.E.D Indicator Light................................................. 9
Heat Light ............................................................... 9
Topside Control Lock & Unlock ................................. 9
Special Features............................................................ 10
Auto-Purge Cleansing ............................................... 10

Aries Spas • User Manual
Internal Clock ........................................................... 10
Customized Circulation Mode .................................... 10
Freeze Protection ..................................................... 12
Internal High Limit Switch.......................................... 12
Interior Fittings.............................................................. 13
Venturi Controls (Air Controls)................................... 13
Circulation Fittings.................................................... 14
Suction Fittings ..................................................... 14
Hydrotherapy / Massage Jets.................................. 15
Standard Jets........................................................ 15
Circular Jets.......................................................... 16
Jumbo Jet ............................................................ 16
Neck Jets ............................................................. 16
Circulation & Recovery Jets ................................... 17
Air Injectors ............................................................. 18
Maintenance ................................................................. 18
Filter ....................................................................... 18
Cleaning Your Filter................................................ 19
Water Treatment....................................................... 21
Disinfectants......................................................... 22
Bromine Products.............................................. 22
Ozone Generator............................................... 22
Adjusting pH ......................................................... 23
Preventing Hard Water or Stain Damage .................. 24
Preventing Algae ................................................... 24
Caring For Your Spa's Surface.................................... 24
Deep-Cleaning of Plumbing Lines............................... 25
Draining Your Spa ..................................................... 25
Troubleshooting Guide ................................................... 27
Trouble Codes ............................................................... 34

Page 1
Aries Spas • User Manual
Installation of Portable Spa
HAVEYOURELECTRICIANREADBEFOREINSTALLATIONBE-
GINS!
Pleasecontactaqualiedelectriciantowireyourspa.
AllAriesSpashaveaHighcurrentGFCI(ground-faultcurrentinterrupt-
er)builtin.Astandardcircuitbreakerisrequiredinyourcircuitsupply
panel.Do not use a GFCI-type breaker in your supply panel.
AllAriesSpasrequirea220voltsupplycircuitconsistingoffourwires.
Use#6AWGwire(copperconductorsonly).
Allmetalcomponentsoftheequipmentassemblyhavebondinglugs.
Theselugsshouldbeconnectedtogetherwithaminimum#6AWGcop-
perconductor.
Allspaequipmentpacksrequireadedicatedbreaker.Thebreakershould
be50amp,(60ampfordouble-jetpumpsystem)singlephase,220volt
service,consistingoffourwires;twohotwires,aneutralwireanda
groundwire.Wiresizeisdeterminedbylengthofrun,butgenerally#8
wirefor0-50feetand#6wirefor51+feetisrecommended.Thismight
vary,dependingonlengthofrunorotherunforeseenfactors.Any varia-
tion from this service will void warranty.
Theequipmentpackageshouldbeinstalledsuchthattheheaterhousing
isinalevel,horizontalpositionandthebottomoftheequipmentisap-
proximatelyfourinchesabovegroundlevelandprotectedfromwaterand
otherelements.
AllAriesSpasaredesignedtobepermanentlyconnectedunits,consisting
ofpumps,heater,lightxtureandSpa-SideControl.
Itistheresponsibilityofthespaownertoinsurethatelectricalconnec-

Page 2
Aries Spas • User Manual
tionsaremadebyaqualiedelectricianinaccordancewiththeNational
ElectricCodeandanylocalandStateElectricalCodesinforceatthetime
ofinstallation.Theseconnectionsmustbemadeinaccordancewiththe
wiringdiagramsfoundinsidethecontrolboxandthewiringdiagrams
withinthismanual.Thisequipmenthasbeendesignedtooperateon60
Hzalternatingcurrentonlyandat240Volts.Makesurethatpowerisnot
appliedwhileperforminganyelectricalinstallation.Acopperbondinglug
hasbeenprovidedontheelectricalequipmentpacktoallowconnection
tolocalgroundedpoints.Thegroundwiremustbeatleast8gaugesolid
copperandmustbeconnectedsecurelytoagroundedmetalstructure.
Replacement of an existing Equipment Pack
Followtheinstructionsabovefortheequipmentinstallationsothatthe
propersettingsaremadeforcurrentandvoltagethatthespawasconnect-
edto.Duetothefrequentupdatesinequipmentmodels,pleaseconsultan
AriesSpatechnicianifthereareanydifferencesincomponentconnec-
tions.
Location
It is very important that your spa be located on a solid, level
foundation.
Alledspaisveryheavy(upto5,000lbs.),withmostoftheweightrest-
ingonthecenterportion.Withoutrmsupportforthebottomofthespa,
settlingcanoccur,causingtheoutsideedgeor“lip”ofthespatocarrythe
weight-load,pullingthespaoutofshape.Cement blocks are not accept-
able, unless they are concreted into place.
A4”thickconcretepadisthedesiredfoundation.Ifabalconyordeckis
used,itmustsupportatleast75poundspersquarefoot.
Aries Spas will not be responsible for damages incurred on spas
placed on other than level, solid surfaces.
Ifyourspaislocatednearwatersprinklers,adjustorrelocatethemsothat

Page 3
Aries Spas • User Manual
waterwillnothitthesidingofthespa.
Gatesgivingaccesstothespashouldbeself-closingandself-lockingfor
safety.
Operation
Initial Start-up
Please read this section fully before attempting initial start-up of
your spa.
Always turn the thermostat(s) and electric power off when lling or
draining the spa, and always fully open any valves that could restrict
water ow to and from the heater element.
Filling your Spa
Yourspashouldbelledwithwatertoapproximatelythemiddleofthe
skimmer(toidentify,seepictureofskimmerinthe“SuctionsFittings”
sectionofthismanual).Thewaterlevelshouldneverbebelowtheregu-
larorwhirlingjets,butshouldnevercoveranyneckjets,therecoveryjet
(see“Jets”sectionforpicture)orbuilt-inpillows.Do not overll spa.
Starting your Circulating Pump
Turnonyourhomecircuitbreakerandservicedisconnect(ifapplicable).
Pushthered“reset”buttonontheGFCI,locatedontherightsideofthe
blackequipmentbox.Within5seconds,thepurgecyclewillcomeon,
runningthejetsandblowerfor
30seconds.Thenthecirculation
pumpwillcomeon.If,withina
fewseconds,waterisnotobserved
owingfromReturnJets(see“Jets”
sectionfordescription),liftthelid
thatcoversyourTopLoadingPres-
sureFilter,andreleaseanytrapped
Equipment Pack

Page 4
Aries Spas • User Manual
airbyturningtheBleedValve(thesmallvalvelocatedonthelterlid)
counterclockwiseuntilyouhearareleaseofair.Do not totally unscrew or
remove the Bleed Valve. Do not remove the black locking ring of the lter
lid at this time or serious damage could occur. OpeningtheBleedValve
willallowanytrappedair
tobepurgedandsome
gurglingorbubblesmay
comefromtheReturn
Jets.Onceasteadystream
ofwaterstartsspurting
fromtheBleedValve,
retightenbyturningina
clockwisedirectionuntil
hand-tight.(Formore
informationontheBleed
Valve,seethe“TopLoad-
ingPressureFilter”sectionofthismanual.)
OncetheCirculatingPumpmotorisrunningandwateriscirculating
properly,youshouldbeabletoobservewaterand/orbubblescoming
fromthetwoCirculatingJets(oneregular-sized,onesmall)usually
locatednearyourstepsand/orthelight.Thisindicatesthatthewateris
circulatingproperly.
Ifnowaterowisobserved,dothefollowing:
1. ListentomakesurethattheCirculatingPumpmotorisrun-
ning.
2. MakesurethattheKnife(“T”shaped)Valvesareopen.These
valvesarelocatedoneithersideoftheblackcontrolbox.They
areopenedifthehandlesareextendedasfaroutastheywill
go.Whenopened,youshouldbeabletoseeeithertheexposed
silverrodoraredretainerclip.
3. RechecktheBleedValveonthelterlidtomakesureyouhave
GFCI

Page 5
Aries Spas • User Manual
releasedalltrappedair.Sometimesdrainingasmallamountof
waterfromtheHoseBib(locatedbytheEquipmentPack)is
alsohelpfulforreleasinganairlock.
Ifyouhavetriedalltheabove,andthereisstillnovisiblewaterow
comingfromtheCirculationJets,STOP! Pushtheblack“Test”buttonon
theGFCItoturnspaoffandcalltheAriesSpasFactoryimmediately!Do
notgoontothenextsteporseriousdamagemayoccurtoyourspaequip-
mentpack.
OnceyouaresurethattheCirculatingPumpmotoriscirculatingthewa-
ter,proceedtothenextsection.
Equipment Pack Controls
Power Switch (GFCI)
YourAriesSpaEquipmentPackisprovidedwithaground-faultcir-
cuitinterrupter(GFCI).ThisGFCImaylookand/oroperatesimilarto
oneyoumayhaveinyourhome,butknowthatitisahighlyspecial-
izeddeviceexclusivetoyourAriesSpa.Itislocatedontherightsideof
theEquipmentPack(notonthefaceoftheequipmentpack).Electrical
problemswithinthespaequipmentaremonitoredbythisdevice.Ifany
potentialshocksituationdoesoccur,thisdevicewillinterruptthepower
supply,therebyremovingthepotentialofdangertoequipmentand/orhu-
manoccupants.
YoucanusethisGFCIasasystem“On-Off”switch.
GFCI Breaker (Test) and (Reset) Buttons
TomakesurethattheGFCIbreakerisoperatingproperly,presstheblack
buttonlabeled“Test”.Ifoperatingnormally,theEquipmentPackwill
shutoff,andtheredbuttonwillpopoutandrequireresetting.Thesame
willhappenifwatercomesintocontactwiththecomponents.
Toreset,pushthered“Reset”button.Iftheequipmenthasbeenwet,and
theredbuttonimmediatelypopsoutagain,waitasufcientamountof

Page 6
Aries Spas • User Manual
timeforallmoisturetoevaporate,andtrytoresetagain.Ifitcontinues
topopout,callyourspadealerorAriesFactory.(Ifyourngersarelarge
andyouhavetroubleresetting,tryusingtheeraserendofapencil).
Spa-Side Controls
YourAriesSpaequipmentiscomposedofstate-of-the-artmicroproces-
sorcircuitry,similartothatofahomecomputer.Alluser-functionsand
operationalchangesaredoneviatheTopSidespacontrol.
Setting the Desired Temperature
TheThermostatcanbesettotemperatureswithinarangefrom70˚
through106˚asdescribedbelow.Pushandholdeitherthe“up”or
“down”arrowbuttonfor
afewseconds.The“ac-
tual”watertemperature
inthedisplaywillbe
replacedwiththe“de-
sired”temperature,and
thenumberwillbegin
toincreaseordecrease,
dependingonwhichar-
rowyouaredepressing.
Whenyougettoyour
newdesiredtemperature,simplyreleasethearrowbutton.Thespawill
nowbeginadjustingthewatertothattemperatureandmaintainitthere.
Usethedigitalreadoutandyourpersonalpreferencesasaguideinadjust-
ingthetemperature.
WARNING: Prolonged immersion in hot water may
induce hyperthermia. The causes, symptoms and effects of
hyperthermia may be described as follows: Hyperthermia
occurs when the internal temperature of the body reaches
a level several degrees above the normal body temperature
of 37˚C (98.6˚F). The symptoms of hyperthermia include:
drowsiness, lethargy and an increase in the internal
Spa-Side Controls

Page 7
Aries Spas • User Manual
temperature of the body. The effects of hyperthermia include:
◊ Unawareness of impending hazard
◊ Failure to perceive heat
◊ Failure to recognize the need to exit the spa
◊ Physical inability to exit the spa
◊ Fetal damage in pregnant women
◊ Unconsciousness and danger of drowning
WARNING-Theuseofalcohol,drugsormedicationcangreatlyincrease
theriskoffatalhyperthermia.
Digital Temperature Readout / Adjustment Readout
TheSpa-SideControlhasadigitalreadoutofthespa'swatertemperature.
(Itisnotuncommonforthetemperatureshowntovaryfromtheactual
watertemperaturebyafewdegrees.)Thisreadoutalsodisplaysthede-
siredtemperatureasyoureset(seebelow).
Increase (Up) and Decrease (Down) Arrows
Toincreasethewatertemperature,pushandholdthe“uparrow”button
(redtriangle).Todecreasethetemperature,pushandholdthe“downar-
row”button(bluetriangle).Asyouholdthebuttonstoadjust,thedigital
temperaturereadout,whichpreviouslyshowedtheactualwatertempera-
ture,willtemporarilyshowthe“desiredtemperature”youareadjusting
to.Oncethedesiredtemperatureisdisplayed,releasetheadjustment
arrow.Thedisplaywillreverttothe“actual”temperature.
Function Buttons
“Jets” Button
Thisbuttonoperatesallthedifferenttypesofhydrotherapymassagejets
inyourspa.PressthebuttonandtheJetPumpwillturnon.Pressagain
andtheJetPumpwillturnoff.
Onspasequippedwith2JetPumps,therewillbeanadditional“Jets”
Button,marked“JET2”.

Page 8
Aries Spas • User Manual
Whenthejetpump(s)areturnedon,aninternaltimerinthecontrolbox
willautomaticallyturnthejetpump(s)offafter30minutes.Thisisasafe-
tyfeaturethatgreatlylengthensthelifeofthejetmotorsandeliminates
unnecessaryuseofelectricity.Ifyouarestillusingthespaandthejet
pump(s)shutoffwhileyouwantthemon,simplypushthe“Jet”button(s)
andthepumpwillcomebackonforanother30minutecycle.
“AUX” Button
The“AUX”ButtonoperatestheAirBlowerPump.Theairblowerforces
airthroughtheAirInjectorFittings.Thesearettingslocatedinthespa
seatsorontheverticalwallundertheseats,andaredesignedtointroduce
airintothespaunderpressure.(Somemodelsresemblesaltshakertops.)
Pushthe“AUX”ButtonandtheAirBlowerwillcomeon.Pushitagain
andtheBlowerwillshutoff.
Thespacontrollerboxwillau-
tomaticallyturnthebloweroff
after30minutes.Thisisasafety
featurethatgreatlyextendsthe
lifeoftheblowerandeliminatesunnecessaryuseofelectricity.Ifyouare
usingtheAirBloweranditturnsoffbutyouwantittobeon,simplypush
the“AUX”ButtonandtheBlowerwillcomebackonagainforanother
30minutecycle.
“Light” Button
The“Light”ButtonoperatestheSpaLight,whichisusuallylocatedin
thestepareaofthespa.Pushthebuttononceandthelightwillturnon.
Pushitagainandthelightwillturnoff.
TheRaydiance®Lightisanoption.AspecialtyLEDbulbreplacesthe
standardlightbulb.Thislighthas8differentcolorsincludingfade/strobe.
ThestandardlightcanlaterbereplacedbytheRaydiance®light,ifde-
Function Buttons

Page 9
Aries Spas • User Manual
sired.
TheRaydiance®lightisoperatedasfollows:Pushthe“Light”button
toturnonoroffasyouwouldthestandardlight.Aslongasthelight
wasleftonformorethan5seconds,thenexttimeyouturniton,itwill
remainthesamecolorasitwaslasttimeyouusedit.Tochangethecolor,
turnthelightoffwithin5secondsofturningiton,thenimmediatelyturn
itonagain.Itwillcycletothenextcolor.Repeatuntilyougettothecolor
ofyourchoice.Thelastcoloronthecycleisfade/strobe.Thelightstarts
bystrobing,thenfadesfromonecolortoanother,cyclingthroughall7of
theothercolors.
ThebulbforthestandardorRaydiance®lightiseasilyreplaceablefrom
theundersideofthespa,insidetheequipmentarea,accessedbythe
equipmentareadoor.Thebulbisa12V9wattlow-voltageoutdoorlight-
ingtypeofbulbfoundatmosthardwarestores.
“INV” Button (Only on models equipped with double jet pumps)
Thisfeatureallowsthetemperaturetoreadright-side-facingwhenlook-
ingatitfrominsidethespa.Normally,thetemperaturedisplayreads
right-side-facingwhenviewingfromoutsidethespa.
Toinvertthedisplay,pressthe“INV”Button,Toreturntostandarddis-
playpressthebuttonagain.
L.E.D. Indicator Light
“Heat” Light
Anytimetheheaterisrunning,thislightwillashjustbelowandtothe
rightofthetemperaturereadoutonthetopsidecontrol.Whenthewater
reachesthedesiredtemperature,thelightwillswitchoff.
Topside Control Lock Mode
TolocktheTopsideControl,pressandholdtheredheat"up"arrowand
thejetbuttonsimultaneouslyuntilthewordLOCappears.Tounlock,
repeat,holdingdowntheredheat"up"arrowandthejetbuttonsimulta-

Page 10
Aries Spas • User Manual
neouslyforabout5seconds,untiltheLOCdisplayisremoved.
Note: While in "LOC" mode, only the light function will operate.
Special Features
Auto-Purge Cleansing
YourAriesSpaisequippedwithanAuto-PurgeSystemthattwicedaily
turnsonallpumpsfor30seconds.Thisautomaticushingoflinesisim-
portanttotheoverallsanitizationofthewater,eliminatingstagnantwater
inunusedplumbinglines.Thisisanautomaticfeatureandtakesnoeffort
onyourpart.Ittakesplacetwicedaily,basedonthemomenttheinternal
clockwaslastreset(seebelow).
Internal Clock
Intheefforttoimproveandsimplifytheoperationsofspas,wehave
replacedthetraditionalhard-to-settimeclockwithaninternaltime-me-
teringdevice.Itiscomputerized,andrequiresnosetting.Itisa12hour
clock,whichcontrolsAuto-PurgingandCustomizedCirculationModes.
Thisclockdivideseachday(24hours)intotwo12-hourperiods.
Thestarttimeisreseteverytimethepowerisrestoredtothespaafterbe-
ingturnedoff,regardlessofwhetherthespawasmanuallyturnedoffor
inadvertentlylostpower.Whenthepowerisrestored,theInternalClock
startsat"0"andgoesto"12",thenrestartsat"0".TheAutoPurgewill
happeneachtimetheclockreaches"0".TheCirculationMode(below)
alsobeginsthen.Starttimeoftheclockismostlyinsignicantexcept
forthestarttimeoftheCustomCirculationMode,unlessaspecicAuto
Purgetimeisdesired.
Customized Circulation Modes
AriesrecommendsleavingtheCirculationModesetin24HourMode,
exceptduringseverelyhotweatherconditions.Inareaswithextremely
hotsummertemperatures,heataccumulatesinthespawater.Sunlightand
hotairtemperaturescansendspawatertemperaturessoaring.Tocombat
thisproblemaspecialCustomizedCirculationModeisavailable.

Page 11
Aries Spas • User Manual
Warning: Never use the Customized Circulation Mode in
Wintertime or when freezing weather could occur. This
disables the Freeze Protection and could cause water in your
equipment or lines to freeze, causing serious damage. Aries
will not warranty against freeze damage caused by improper
Circulation Mode settings.
YourAriesSpaisfactory-settoruncontinuously.Toconvertfromcon-
tinuousoperationtopart-timeoperationoftheCirculation,pushandhold
the“HeatUpArrow”(redtriangle)Button.Whiledepressingit,push
andholdthe“AUX”button.“Afterafewseconds“C12”willappearin
theLEDareaofthetopside.Thismeansthatineach12hourltercycle,
thecirculatingpumpwillrunfor12hours.(Thisisthecontinuousmode
thespaissetinwhenitleavesthefactoryanditshouldremainthisway
atalltimesunlessanexcessiveheatbuildupoccurs.)Withinasecond,the
12willchangeto2,then3,andsoon,untilitcyclesbackaroundto12,.
Whenyougettothenumberyouwant,releasethebuttons.Remember,
yoursystem'sinternalclock,dividesadayintotwo12hourperiods,and
youwanttodecidehowlongtorunthesystemper12hours.
Forexample:For8hoursofoperationperday,settheModeSettingto4.
Then,ineach12hourperiod,yoursystemwouldcirculatefor4hours,
turnofffor8hours(makingupthe12hourperiod).Thenitwouldbegin
thenext12hours,runningfor4morehours,thenturnofffor8.
C2=2hourstwicedailyC3=3hourstwicedaily
C4=4hourstwicedailyC5=5hourstwicedaily
C6=6hourstwicedailyC7=7hourstwicedaily
C8=8hourstwicedailyC9=9hourstwicedaily
C10=10hourstwicedailyC11=11hourstwicedaily
C12=Continuous ltration
Duringthe“off”periodineachruncycle,ifheatisrequired,thecircu-
lationpumpwillcomeonandtheheaterwilloperateuntilthedesired

Page 12
Aries Spas • User Manual
temperatureisreached,atwhichtimethecirculationpumpandheater
willagainturnoff.
Duringthe“off”period,jet,airblowerandlightfunctionsarestillavail-
abletobeused,.
It is recommended that when you initially set to the Customized
Circulation Mode that you do this in the evening, remembering
to turn the system off, then back on to reset start times. The
operating times will then be at night, in the cooler periods.
Freeze Protection
InanAriesContinuousCirculatingSpa,thepotentialforfreezedamageis
almostnonexistent,asmovingwaterdoesn'tquicklyfreeze,andthewater
iskeptheatedtoaminimumtemperature..WiththeadditionoftheAuto-
Purgefunction,freezedamageisveryrareandismostcommonwithspas
thathavebeendrainedforthewinter.
Aries recommends never draining a spa or leaving a spa drained at any
time of the year, especially for the winter. Regardless of draining proce-
dures used, there will always be a small amount of water remaining in the
plumbing lines. In wintertime, this water can freeze and expand, causing
serious damage to your plumbing and equipment systems. Aries Spas
does not warranty freeze-damage done to spas left drained.
Internal High Limit Switch
Yourspaequipmentpackisequippedwithaheateroverheatsensor.This
sensorprotectsyourheaterbyturningitoffincaseswherethewatertem-
peratureintheheaterhavereachedahigher-than-normalcondition.This
canhappenwhenyourlteriscloggedordirtyenoughtoslowthewater
owandwateristrappedintheheaterforlonger-than-normalperiodsof
time.
IftheLimitSwitchtrips,thedigitaltemperaturereadoutwillash.This
Table of contents
Popular Hot Tub manuals by other brands

Aquatic
Aquatic AI2522SK Specification sheet

Aquatic
Aquatic Serenity 1 Specification sheet

Strong Pools and Spas
Strong Pools and Spas Rio Spa owner's manual

Dreammaker Spas
Dreammaker Spas Crossover Collection owner's manual

Vita Spa
Vita Spa xStream owner's manual

SOFINA
SOFINA DELUXE PORTABLE SPA owner's manual

Aquatic
Aquatic AI6032DHS Specifications

CalderaSpas
CalderaSpas HIGHLAND Series owner's manual

Dimension One Spas
Dimension One Spas Aurora II Specifications

EAGO
EAGO TS Series Installation instruction

Kohler
Kohler K-1111-VLN-0 installation instructions

American Standard