Arizona AirScent DREAMER Series User manual

fragrance diffuser product manual
DREAMER SERIES

SPECIFICATIONS
Plug and Play
Battery Backup
10 Intensity Levels
What’s Included
Be sure the packaging is complete when you rst open it. If anything is
Product
Size
Volume
Coverage
Dreamer
10” x 15” x 5”
34 oz
1929 sf
Mini Dreamer
9” x 11” x 3.5”
17 oz
1215 sf

FILL FRAGRANCE
MOUNTING
1. Insert key.
2. Rotate key 10 degrees clockwise to unlock.
3. Unscrew and take out the atomized head. Fill with fragrance.
4. Insert the atomized head and bottle.
5. Take out key.
1. Choose a position close to power source
2. Fasten mounting bracket to wall with included hardware.
3. Hang the machine.
• DO NOT SET UNITS ON FLOOR. They must be mounted or the unit could tip over and damage the oor and the unit itself.
• NOT RECOMMENDED to hang unit over 24 inches off the ground.
• Keep diffusion path clear. DO NOT mount behind curtains.

HOW TO OPERATE
1. Above data is based on standard test oil.
2. Consumption may differ based on grade and oil.
NOTES
INTENSITY AND CONSUMPTION
Working(s)
Working(s)
Stop(s)
Stop(s)
Grade
Grade
G1
G6
40s
240s
400s
200s
80s
280s
360s
160s
120s
320s
320s
120s
160s
360s 400s
280s
80s 40s
200s
240s
G2
G7
G3
G8
G4
G9 G10
G5
Intensity Up Intensity Down

CLEANING DIFFUSER
To protect the life of your diffuser and ensure optimal performance, be sure to clean your
diffuser when you rell the bottle with fragrance, change fragrances or you notice the
atomization volume goes weak.
Steps to Clean:
1. Remove fragrance bottle and diffuser head
2. Unscrew fragrance bottle from diffuser head
3. Fill 15% of the fragrance bottle with isopropyl alcohol, reattach to diffuser and diffuse
5-10 minutes
4. Dispose of alcohol, air out the diffuser head and bottle and replace with fragrance
PLACEMENT RECOMMENDATIONS
• Choose a location where the fragrance can utilize natural airow.
• Units need to be mounted low on the wall approx 20 inches off the ground.
• It is best to place away from air vents for optimal performance.
• For larger rooms, place your diffuser in a centralized location, next to a power outlet for a
more even fragrance diffusion.
• Great for gyms, entry points, models, clubhouses and large spaces.
• Keep the diffuser in an open area. Do not place directly behind furniture or anything that
can block the ow of fragrance.
• Do not mount above 24 inches off the oor.
• Do not set on the oor.

Power ON
Connect with power supply, ip ON/OFF switch to ON (Figure 1), machine will power on,
display screen will light up showing the time and atomized grade.
Power OFF
Turn switch to OFF (Figure1), machine will power down, display will turn off.
Auto-Lock
If there is no interaction with display, the screen will go to sleep and lock automatically after
1 minute.
Unlock
Touch and hold SET for about 5 seconds and wait for beep.
Display screen should turn back on and unlock programming features.
PROGRAMMING
FIGURE 1

2
Local Time Setting
Touch SET button (about 5 seconds) till you hear a
beep. Touch to move setting position, touch to
adjust local time. Touch ENT to con rm (Figure 1).
Diffusion Time Setting
There are (3) working periods available to be set for
everyday.
Touch SET button to check out the working periods
from Monday to Saturday. Touch to choose working
periods. Touch to adjust setting numbers.
PROGRAMMING
1
*Note: The rst working period is factory defaults with operating time 07:00 and closing 21:00, the rest
are all with 00:00. Military Time.

TROUBLESHOOTING
For optimal performance and to avoid any clogging of your diffuser, only use essential oil
blends from Phoenicia Essence or Arizona Air-Scent. These fragrances have been carefully
developed specically for our diffusers. Failure to do so may cause damage to your machine.
Always ensure your diffuser is kept in an upright position. Tilting of diffuser may cause oil to
leak onto surface.
PROBLEM
Device not diffusing
Diffuser spraying liquid
Can hear device working
but fragrance mist is low,
not visible and cannot smell
fragrance
Fragrance oil is leaking
Device emitting loud,
unusual noise
No display on screen
• Device is in “pause mode”
in between cycles
• Faulty pump
• Diffuser core is damaged
• Machine is tilted or angled
• Atomization head is
blocked
• Diffuser core with straw is
missing
•Pump is damaged
• Fragrance bottle is loose
• Diffuser is not vertical
• Seal is broken or missing
• Air pump is loose
• Air pump is damaged
• Loss of power
• Faulty power source/plug
• Display screen is damaged
• Wait for diffuser to change to
“working mode”
• Replace pump*
• Replace diffuser core*
• Make sure device is upright
• Replace fragrance with alcohol
and run through diffuser for
5 min
• Replace diffuser core w/ straw*
• Replace pump*
• Ensure fragrance bottle is
fastened straight and tight
• Ensure diffuser is standing
upright
• Replace seal*
• Re-tighten the pump
• Replace air pump*
• Make sure power is ON
• Try different outlet. Replace plug*
• Replace display screen*
POSSIBLE CAUSE SOLUTION
*For replacement parts, please contact [email protected]

azairscent.com
CAUTIONCAUTION
1. Shall not modify, disassemble or repair the machine arbitrarily. If any failure occurs,
2. Do not damage the power cord, force to bend, yank, heavy load, clip or reprocess.
• Do not use the AC plug when it is damaged or not compatible with socket
• Do not wet the machine or AC plug
• Do not use overloaded power socket, wire or broken plug
3. Do not touch the wire or product shell during lighting/thunderstorms.
4. Do not disassemble the machine when it is operating.
WARNINGWARNING
1. Atomization icon will display on screen but the machine will not diffuse when it stays on
pause time.
2. Touch/tap icons will not operate when diffuser is in lock status.
3. If the display screen not functioning normally, displays unclear or program crash. Reset
diffuser by touching ENT and hold for 5 seconds until beep.
4. Diffuser must be vertical at all times when fragrance is in bottle when lying at, tilted or
horizontal the fragrance could over ow. This may affect diffuser ef ciency if circuit board
or pump is contaminated.
5. After installation, please keep the machine vertical. Tilting or placing at may cause an oil
over ow. The machine ef ciency may be effected if the circuit board is contaminated.
This manual suits for next models
2
Table of contents
Other Arizona AirScent Accessories manuals